Power Capacitors and Capacitor BanksSelected Projects
siemens.com/energy
Answers for energy.
-
2In 2009, Siemens extended its product portfolio and since then delivers High Voltage Power Capacitors and Capacitor Banks to renowned customers worldwide. These products and systems fulfill the highest electrical and mechanical requirements; they are used for the most diversified applications and can be operated under the most stringent environmental conditions.
Siemens High Voltage Power Capacitors do not only enhance the transmission capacity or the network stability, but also contribute to economical growth and enable a significant reduction of carbon dioxide emissions.
Capacitors for the World
01
06
02
04
05
03
-
3Siemens Power Capacitor factory is located in the industrial complex in Jundia, Brazil, the largest production complex of Siemens in Latin America.
Siemens Power Capacitor Factory
1959 Laelc starts operations, manufacturing Power Capacitors for several projects, including Itaip HVDC, the first 600 kV HVDC of the world in the 80s.
1979 Laelc buys the technology to manufacture internally fused capacitors
2007 Siemens acquires from Laelc the technology to manufacture power capacitors and capacitor banks
2009 Siemens High Voltage Power Capacitors factory starts commercial operation and was awarded its first large HVDC order for India
2013 Siemens High Voltage Power Capacitors are globally present in several countries around the world with a product portfolio for all types of application
History 50 Years of Experience
Selected Projects Page
01 HVDC Adani India 5
02 HVDC Estlink 2 Finland & Estonia 6
03 FSC Tucuru-Manaus Brazil 7
04 MSCDN Lincs Wind Farm UK 8
05 HVDC Hudson USA 9
06 HVDC Black Sea Georgia 10
07 Other selected projects 11
High Voltage Power Capacitor Factory
Other selected projects
-
4Power Capacitors Technical Data
Flexible AC Transmission Systems (FACTS)
Parallel Compensation
Static Var Compensator (SVC)
Mechanically Switched Capacitor with Damping Network (MSCDN)
Mechanically Switched Capacitors (MSC)
Series Compensation
Thyristor Controlled Series Compensation (TCSC)
Thyristor Protected Series Compensation (TPSC)
Fixed Series Compensation (FSC)
AC Harmonic Filters
AC PLC Filters
Long Distance and Back-to-Back HVDC AC & DC Filters
AC & DC Surge Capacitors
Capacitor Banks Applications
Capacitor Unit Design
Technology Internally fused, externally fused, fuseless, and unfused
Rated voltage With internal fuses: 15 kVWithout internal fuses: 24 kV
Frequency 50 Hz/60 Hz
Rated power Up to 1000 kvar (50 Hz) Up to 1200 kvar (60 Hz)
Current Max. 180 A
BIL 95 kV, 125 kV, 150 kV, 170 kV, 200 kV
Dielectric Polypropylene film and oil
Impregnant Biodegradable PCB-free oil
Discharge resistor 75 V/10 min or 50 V/5 min
Losses With internal fuses: < 0.20 W/kvarWithout internal fuses: < 0.12 W/kvar
Temperature range -50/+55 C
Standards IEC, IEEE, ABNT, CSA, and others
Quality certificates ISO 9001; ISO 14001; OHSAS 18001
Final figures to be confirmed during projectFor other standards please consult the factory
Siemens entered the Power Capacitor market with a product for the most diversified applications. Long-term reliable technology and intensive R&D investments lead to a state-of-the-art product, compliant with the most stringent technical and environmental requirements,
including extremely low temperatures (like -50 C in northern Canada), extremely high temperatures (like +50 C in India), high humidity (like in the rainforests of northern Brazil) and the most extreme seismic zones (like in New Zealand).
-
5The HVDC system operated by Adani Power Ltd. has a transmission capacity of 2500 MW and provides low-loss energy transmission over a distance of approximately 960 km, from the port of Mundra located on the west coast to the industrial regions in the Haryana state.The AC filters for this HVDC system represent the first
HVDC Adani India
Technical DataLocations Mundra and Mohindergarh S/S
Total rated power 3.7 Gvar
Unit output 815.6 to 852.0 kvar
Bank voltages 280.3 to 294.8 kV
Rated unit voltages 7.8 to 9.7 kV
Quantity of units 4,840
Technology Internally fused
Supply date August 2010
Temperature category -5 /+50 C
large order for the capacitor factory in Jundia, which delivered the first units to India only 6 months after the official inauguration in December 2009. The total installed output of the 54 single phase high voltage AC filters was close to 4000 Mvar and the total number of units supplied was 4840 (including spare parts).
-
6HVDC Estlink 2 Finland & Estonia
Technical DataLocations Anttila and Puessi substations
Total rated power 1.17 Gvar
Unit output 113 to 849 kvar
Bank voltages 6.1 to 325.5 kV
Rated unit voltages 3.0 to 19.2 kV
Quantity of units 1,878
Technology Internally fused, fuseless and unfused
Supply date August 2012
Temperature category -40/+40 C
In December 2010 Fingrid and Elering awarded the contract for the Estlink 2 Converter Stations to Siemens, using a HVDC Transmission System with a transmission capacity of 650 megawatts at a DC voltage of 450 kilovolts.
The Siemens capacitor factory in Brazil supplied a total of 24 single phase high voltage AC filter banks (C1-type) using internally fused and fuseless technology and 36 single phase medium voltage AC filter banks (C2/C3-type unfused technology).
-
7FSC Tucuru-Manaus Brazil
Siemens Ltda. Brazil was awarded the FACTS systems for the 1800 km long 500 kV HV transmission system connecting the Tucuru Hydro Power Plant with the city of Manaus in 2010. The scope of supply included a total of 18 Fixed Series capacitors located at 5 different sub-stations in the Amazon forest.
Technical DataLocations 5 substations along the trans-
mission line Tucuru-Manaus
Total rated power 6.8 Gvar
Unit output 743.8 to 825.4 kvar
Bank voltage 500 kV
Rated unit voltages 6.3 to 7.1 kV
Quantity of units 8,496
Technology Internally fused
Supply date 2010 2012
Temperature category -5/+50 C
The Capacitor factory in Jundia was responsible for the supply of all the capacitors of this project, considered to be the largest FACTS project ever executed worldwide.
-
8MSCDN Lincs Wind Farm UK
Technical DataLocation Walpole substation, England
Total Rated Power 392 Mvar
Unit output 180 to 867 kvar
Bank voltage 132 and 13.9 kV
Rated unit voltages 4.3 to 11.8 kV
Total units 576
Technology Internally fused and fuseless
Supply date April 2011
Temperature cat. -25/+40 C
The Lincs project, owned by Lincs Wind farm Limited is located in the Greater Wash wind farm park, England and will generate capacity of 270 MW. The energy generated offshore is transferred to the grid via the Walpole onshore substation located in the Norfolk County. Siemens Trans-mission and Distribution Ltd., UK was awarded with the construction of the entire onshore substation in 2010.
The Siemens High Voltage capacitor plant has provided a total of 6 single phase Capacitor Banks for the 132 kV-MSCDN comprising fuseless C1 and C2-banks with a total installed rating of 246,3 Mvar, as well as 6 single phase banks with internally fused capacitors for the 13.9 kV CMSC with a total output of 145.7 Mvar.
-
9HVDC Hudson USA
Technical DataLocations West 49th Street and Bergen
Total Rated Power 1.3 Gvar
Unit output 122 to 1019 kvar
Bank voltages 8.4 to 244.7 kV
Rated unit voltages 7.2 to 17.7 kV
Total units 1,524
Technology Internally fused and unfused
Supply date May 2012
Temperature category -30/+40 C
In May 2011 Hudson Transmission Partners, LLC awarded the contract to Siemens to connect the power supply net-works of New Jersey and New York, USA using a 660 MW back-to-back HVDC system will contribute to the stabiliza-tion of the connected systems, a key benefit in the event of grid disturbances or blackouts.
The capacitor plant in Brazil supplied 18 single phase High Voltage AC Filter banks (internally fused technology) and 36 single phase Medium voltage AC Filter banks (C2/C3 and C4-type, unfused technology) for this HVDC system, providing unit outputs larger than 1.0 Mvar for the first time.
-
10
HVDC Black Sea Georgia
Technical DataLocation Akhaltsikhe substation
Total rated power 1.266 Gvar
Unit output 220 to 722 kvar
Bank voltages 60.7 to 354.6 kV
Rated unit voltages 9.3 to 18 kV
Quantity of units 2,237
Technology Internally fused & unfused
Supply date August 2011
Temperature category -25/+50 C
In August 2010 Energotrans Ltd. awarded the contract to Siemens for 350 MW back-to-back HVDC systems in Georgia. The HVDC converter station will connect the networks of Georgia and Turkey via two back-to-back links.
The capacitor plant in Brazil supplied 27 single phase High Voltage AC Filter banks (internally fused technol-ogy) and 36 single phase Medium voltage AC Filter banks (C2 and C3-type, unfused technology) for this HVDC system located at an altitude of 1,100 meters above sea level in a seismic region.
-
11
ProjectCustomer/ Country/ Year
Scope Technical Data Highlight/ Technology
HVDC WATL AltaLinkCanada2013
36 x HV single phase AC filter banks; 60 x MV single phase AC filter banks; 6 x HV single phase shunt banks
Total rated power 3,045 Mvar Very low temperature -50 C, internally fused and unfused capacitors
Unit output 122.9 to 993.5 kvar
Bank voltage 5.73 to 440.61 kV
Unit voltage 5.73 to 17.06 kV
Quantity of units 3,744
MSCDN 400 kV RTE France2013
17 x MSCDN (Type 150 Mvar 380 kV)
Total rated power 5,665 Mvar Largest MSCDN project ever awarded to Siemens, Internally fused
Unit output 593.2 to 886.2 kvar
Bank voltage 24.39 to 553.91 kV
Unit voltage 7.04 to 10.66kV
Quantity of units 6,528
HVDC ATCO ATCO Electric Canada2013
36 x HV single phase AC filter banks; 60 x MV single phase AC filter banks; 12 x HV single phase shunt banks
Total rated power 2,462 Mvar Very low temperature -50 C, internally fused and unfused capacitors
Unit output 126.1 to 963.2 kvar
Bank voltage 8.86 to 376 kV
Unit voltage 5.58 to 18.25 kV
Quantity of units 3,558
SVC Diego de Almagro
TranselecChile 2013
1 x MSC (Type 75.64 Mvar 12.27 kV)
Total rated power 75.64 Mvar High seismic conditions, internally fused
Unit output 900.5 kvar
Bank voltage 12.27 kV
Unit voltage 6.133 kV
Quantity of units 84
Harker, Hutton and Stella400 kV MSCDN
National GridUnited Kingdom 2013
5 x MSCDN (Type 225 Mvar 400 kV)
Total rated power 1,459 Mvar Low temperature -25 C, internally fused
Unit output 719.8 and 825.1 kvar
Bank voltage 244 kV and 31.7 kV
Unit voltage 7.925 and 9.403 kV
Quantity of units 1,800
MSCDN Gwynt Y Mor
RWEUnited Kingdom2012
6 x 132 kV filter banks; 4 x 13.9 MSC banks
Total rated power 495 Mvar Internally fused and fuseless capacitors
Unit output 212.6 to 875.5 kvar
Bank voltage 6.735 to 98.05 kV
Unit voltage 6.735 to 12.256 kV
Quantity of units 642
SVC Bout de Llle Hydro QuebecCanada2013
2 x three-phase single tuned filter banks; 2 x three-phase TSC-banks
Total rated power 1,400 Mvar Low temperature -40 C, internally fused, high seismic requirements
Unit output 922 to 934 kvar
Bank voltage 28 to 36.5 kV
Unit voltage 7.1 to 9.1 kV
Quantity of units 1,602
SVC Gerdau Diaco Diaco S.A.Colombia2012
3 x three-phase filter circuits Total rated power 118.5 Mvar Industrial electric arc furnace application, internally fused
Unit output 584.4 to 1091.5 kvar
Bank voltage 7 to 20.8 kV
Unit voltage 4.04 to 12 kV
Quantity of units 180
SVC Horqueta AndeParaguay2011
3 x three-phase single tuned filter banks; 2 x three-phase TSC-banks
Total rated power 265 Mvar Internally fusedUnit output 727.58 to 783.44 kvar
Bank voltage 17.7 to 21.42 kV
Unit voltage 5.57 to 6.18 kV
Quantity of units 350
HVDC Kontek Energinet Denmark2011
1 x three-phase HV filter (282 kV); 2 x three-phase MV filter banks
Total rated power 96.7 Mvar Noise reduced with exter-nal noise damping hoods, internally fused and unfused capacitors
Unit output 643/435/427 kvar
Bank voltage 282 kV
Unit voltage 20.7 / 17.2 / 19.2 kV
Quantity of units 157
MSC London Array Windfarm
London ArrayUnited Kingdom2011
4 x MSCDN (Type 150 kV)
Total rated power 156.2 Mvar Fuseless capacitorsUnit output 360.5 / 370.2 kvar
Bank voltage 150 kV
Unit voltage 14.2 / 4.16 kV
Quantity of units 445
HVDC Cookstraight, Pole 3
TranspowerNew Zealand2011
27 x HV single phase AC filter banks; 27 x MV single phase AC filter banks; 3 x HV single phase shunt banks
Total rated power 1,165 Mvar Very high seismic require-ments, internally fused and unfused capacitors
Unit output 270 to 833 kvar
Bank voltage 257 to 348 kV
Unit voltage 9.1 to 13.7 kV
Quantity of units 1,690
MSC S/S J Paran, S/S Vilhena
ELETRONORTEBrazil2010
4 x MSC (Type 20.52 Mvar 242 kV)
Total rated power 82.1 Mvar First fuseless applicationUnit output 570 kvar
Bank voltage 242 kV
Unit voltage 11.646 kV
Quantity of units 144
SVC Bom Jesus da Lapa II
TAESABrazil2010
Filter I and Filter II for SVC Total rated power 42 + 66 Mvar First SVC application, internally fused
Unit output 786 kvar / 916.3 kvar
Bank voltage 23.16 kV / 21.46 kV
Unit voltage 13.369 kV /12.389 kV
Quantity of units 54 / 72
MSC ANDE Paraguay
RIEDER & CIA/CLYFSAParaguay2009
1 x MSC (Type 12 Mvar 24 kV)
Total rated power 12 Mvar First capacitor bank delivery, internally fused
Unit output 500 kvar
Bank voltage 24 kV
Unit voltage 13.2 kV
Quantity of units 24
-
Published by and copyright 2013: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany
Siemens AGEnergy SectorPower Transmission DivisionTransmission SolutionsFreyeslebenstrasse 191058 Erlangen, Germanywww.energy.siemens.com/hq/en/power-transmission/high-voltage-products/capacitors.htm
For more information, please contact Siemens Ltda., E T TS TI 3 CA Av. Eng. Joo F.G. Molina 1745 13213-080 Jundia SP Brazil Phone: +55 11 4585 2303 +55 11 4585 3150
For more information, please contact our Customer Support Center. Phone: +49 180/524 70 00 Fax: +49 180/524 24 71 (Charges depending on provider)E-mail: [email protected]
Power Transmission Division Order No. E50001-G610-A130-V1-4A00 | Printed in Germany | Dispo 30003 | c4bs No. 7495 | TH 150-130701 | W | 473222 | WS | 09131.0
Printed on elementary chlorine-free bleached paper.
All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners.
Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.