UÄÙÝãĮĦ HþÙÊçÝ L Êã®ÊÄÝ MÙ»®Ä¦ AÊٮĦ ATEX D®Ùã®ò 94/9/EC Ä IECEø CÙ㮥®ã®ÊÄ S«Ã Temperature Class Mark For specic types of protecƟon according to the applicable standard [ ] for associated apparatus Equipment ProtecƟon Level 0575 II 1 G 14 023 European Community Manufactured according to applicable EC DirecƟves Marking for equipment used in explosive atmospheres Equipment Category Mines M1 Very High protecƟon M2 High protecƟon Non 1 Very high protecƟon Mines 2 High protecƟon 3 Normal protecƟon ( ) for associated apparatus NoƟed/Accredited Body who has released cerƟcaƟon CerƟcaƟon Number Progressive Year of issuing ATEX DirecƟve 94/9/EC Supplementary leƩer X: ParƟcular condiƟons of use U: Component IIC T4 Ex ia Ga 94/9/EC Marking NoƟed Body number for producƟon surveillance Equipment Group I for Mines, II dierent from Mines Type of protecƟon Gas Group 0019 X X BVS 14 . ATEX cerƟcate IECEx cerƟcate CENELEC/IEC standard marking Hazardous Atmospheres G: Gas, Vapour, Mist D: Dust BVS IECEx ATEX IECEx Scheme Type of protecƟon Concept Code EPL IEC /CENELEC standard US Division Standard US Zone Standard Canadian Div. Standard Canadian Zone Standard Gas General requirements 600790 FM3600 600790 600790 Intrinsic Safety Energy limitaƟon Ex ia Ex ib Ex ic Ga or Ma Gb or Mb Gc 6007911 FM3610/UL913 6007911 C22.2 No. 157 6007911 Intrinsically Safe systems Energy limitaƟon Ex ia Ex ib Ex ic Ga Gb Gc 6007925 Increased Safety Non sparking Ex e Gb or Mb 600797 600797 600797 Type n (non sparking/non incendive) Ex nA Ex nC Gc 6007915 FM3611 6007915 C22.2 No. 213 6007915 Flameproof / Expl. Proof Explosion containment Ex d Gb or Mb 600791 FM3615/UL1203 600791 C22.2 No. 30 600791 Powder lling Ex q Gb or Mb 600795 600795 600795 Type n (enclosedbreak) Ex nC Gc 6007915 FM3611 6007915 C22.2 No. 213 6007915 EncapsulaƟon SeparaƟon of explosive atmosphere from igniƟon Ex ma Ex mb Ex mc Ga or Ma Gb or Mb Gc 6007918 6007918 6007918 Type n (sealed/hermeƟcally sealed) Ex nC Gc 6007915 FM3611 6007915 C22.2 No. 213 6007915 PressurizaƟon Ex pv Ex px Ex py Ex pz Gb or Gc Gb or Mb Gb Gc 600792 FM3620/ NFPA 496 600792 Oil immersion Ex o Gb 600796 600796 600796 Type n (restricted breathing) Ex nR Gc 6007915 6007915 Special requirements Ga 6007926 Dust Intrinsic Safety Energy limitaƟon Ex ia Ex ib Ex ic Da Db Dc 6007911 FM3610/UL913 6007911 C22.2 No. 157 6007911 Dust igniƟon proof SeparaƟon of explosive atmosphere from igniƟon Ex ta Ex tb Da Db 6007931 FM3616/UL1203 C22.2 No. 25 Dust Ɵght Ex tc Dc FM3611/ ANSI/ISA 12.12.01 EncapsulaƟon Ex ma Ex mb Ex mc Da Db Dc 6007918 6007918 6007918 PressurizaƟon Ex pD Db or Dc 612414 NFPA 496 612414 6007931 E½ãÙ®½ AÖÖÙãçÝ ¥ÊÙ GÝ Ä DçÝã EøÖ½ÊÝ®ò A ãÃÊÝÖ«ÙÝ IP (IEC/EN 60529) First numeral ProtecƟon against solids Second numeral ProtecƟon against water 0 No protecƟon 0 No protecƟon 1 Greater than 50 mm 1 VerƟcal dripping 2 Greater than 12,5 mm 2 Angled dripping (15°) 3 Greater than 2,5 mm 3 Spraying 4 Greater than 1 mm 4 Splashing 5 Dust protected 5 Jeƫng 6 Dust Ɵght 6 Powerful jeƫng 7 Temporary immersion 8 ConƟnuous immersion Nema (Standards PublicaƟon 250) Type ApplicaƟon ProtecƟon against 1 Indoor General purpose 2 Indoor Dripping water, falling dust 3, 3R, 3S Outdoor Rain, snow, windblown dust 4, 4X Indoor / Outdoor HoseDirected water, Corrosion (X) 5 Indoor Angled dripping water, seƩling dust 6 Indoor / Outdoor Temporary Submersion 6P Indoor / Outdoor Prolonged Submersion 7 Indoor Hazardous LocaƟon Class I 8 Indoor / Outdoor Hazardous LocaƟon Class I 9 Indoor Hazardous LocaƟon Class II 12, 12K Indoor Dripping noncorrosive liquid, Dust 13 Indoor Water, oil, dust, seepage PÙÊãã®ÊÄ D¦Ù Atmosphere Class * Division * Zone ** Area ClassicaƟon Gas Class I Div. 1 Zone 0 ConƟnuous Hazard Zone 1 IntermiƩent Hazard Div. 2 Zone 2 Abnormal CondiƟons Hazard Dust Class II Div. 1 Zone 20 ConƟnuous Hazard Zone 21 IntermiƩent Hazard Div. 2 Zone 22 Abnormal CondiƟons Hazard Fiber Class III Div. 1 Zone 20 ConƟnuous Hazard Zone 21 IntermiƩent Hazard Div. 2 Zone 22 Abnormal CondiƟons Hazard * according to NEC 500 / CEC Annex J; ** according to IEC / NEC 505 / CEC 18 D®ò®Ý®ÊÄÝ / ZÊÄÝ Atmosphere Class * Group * Group ** RepresentaƟve element Gas Class I Group I Methane Group D Group IIA Propane Group C Group IIB Ethylene Group B Group IIC (except C 2 H 2 ) Hydrogen Group A Group IIC Acetylene Dust Class II Group G Group IIIB NonconducƟve dusts Group F Group IIIB Carbonaceous dusts Group E Group IIIC Metal dusts Fiber Class III Group IIIA Fibers or yings * according to NEC 500 / CEC Annex J; ** according to IEC / NEC 505 / CEC 18 GÙÊçÖÝ Combined equipment desired category 1 / M1 2 / M2 3 2 1 HFT 0 SIL 1 0 HFT 1 SIL 2 HFT 0 SIL 1 ” means that no safety device is required. “SIL 1” or “SIL 2” is required Safety Integrity Level of safety related device according to EN 61508. Fault Tolerance of Equipment (number of single faults that cause the apparatus to fail) M®Ä®Ãçà SIL ¥ÊÙ ATEX Ý¥ãù Ù½ã ò®Ý (EN 50495) G.M. INTERNATIONAL S.R.L Via San Fiorano, 70 20852 Villasanta (MB) ITALY phone: +39 039 2325038 [email protected] www.gmintsrl.com ATEX Ä IECEø: GÙÊçÖÝ, Cã¦ÊÙ®Ý, ZÊÄÝ Ä EPLÝ DeniƟon Explosive atmosphere 94/9/EC (ATEX) 99/92/EC (ATEX) IECEx Group Equipment Category Area classicaƟon Group EPL Place where an explosive atmosphere is frequently or for long periods or conƟnuously present Coal mine I M1 I Ma Gas II 1G Zone 0 * II Ga Dust II 1D Zone 20 ** III Da Place where an explosive atmosphere is occasionally present during normal operaƟon Coal mine I M2 I Mb Gas II 2G Zone 1 * II Gb Dust II 2D Zone 21 ** III Db Place where an explosive atmosphere is not present during normal operaƟon, and eventually for short periods Gas II 3G Zone 2 * II Gc Dust II 3D Zone 22 ** III Dc * according to IEC/EN 60079101; ** according to IEC/EN 60079102 ProtecƟon Level Very High two independent means of protecƟon or one protecƟon allowing two independent faults High single mean of protecƟon allowing only one fault Normal safe during normal operaƟon Field Equipment: SIMPLE APPARATUS: Less than 1.5 V; 0.1 A; 20 μJ; 25 mW (TC, RTD, Pot, Switch...). Simple apparatus is considered not to require cerƟcaƟon by a noƟed body; cerƟcaƟon to the ATEX DirecƟve is not required because of the low levels of energy, which are added to the intrinsically safe circuit by this apparatus. A simple apparatus is required to be clearly idenƟed when it is installed. Simple apparatus shall conform to all relevant requirements of the standard. INTRINSICALLY SAFE APPARATUS: Requires cerƟcaƟon. (TX, I/P, Solenoid Valve, Proximity, Field Display...) Safety Parameters to be matched by Associated Apparatus: Ui / Vmax (Max. Input Voltage); Ii / Imax (Max. Input Current); Pi (Max. Input Power); Ci (Internal Capacitance); Li (Internal Inductance) Control Room Equipment: ASSOCIATED APPARATUS: Requires cerƟcaƟon. (Galvanic Isolators, Zener Barriers, Signal CondiƟoners) Safety Parameters to be matched with Intrinsically Safe Apparatus: Uo / Voc (Open Circuit Voltage); Io / Isc (Short Circuit Current); Po (Max. Output Power); Co / Ca (Allowed Capacitance); Lo / La (Allowed Inductance); NON INTRINSICALLY SAFE APPARATUS: All Apparatuses without Approval (PLC, DCS, Computers, Controllers...) E½ãÙ®½ ÖÖÙãçÝ ¥ÊÙ IS AÖÖ½®ã®ÊÄÝ Max surface Temperature T class * T class ** 450 °C T1 T1 300 °C 280 °C 260 °C 230 °C 215 °C T2 T2A T2B T2C T2D T2 200 °C 180 °C 165 °C 160 °C T3 T3A T3B T3C T3 135 °C 120 °C T4 T4A 100 °C T5 T5 85 °C T6 T6 * according to NEC 500 / CEC Annex J ** according to IEC / NEC 505 / CEC 18 T4 T ÃÖÙãçÙ C½ÝÝ OpƟon A: (Zone System NEC 505 / CEC 18) OpƟon B: (Division System NEC 500 / CEC Annex J) Conformity to US requirements Explosion ProtecƟon ProtecƟon method Class I Zone 0 A Ex ia IIC T4 Class I Div 1 Groups A, B, C, D T4 Gas, Vapor or Fiber Area ClassicaƟon MÙ»®Ä¦ ¥ÊÙ NÊÙã« AÃÙ® ÊٮĦ NEC / CEC Temperature Class Gas Group Temperature Class Gas Group Gas, Vapor or Fiber Area ClassicaƟon

description

Instrumentation specifications

Transcript of Poster is 2014

Page 1: Poster is 2014

U H L

M A ATEX D 94/9/EC IECE C S

Temperature Class 

Mark For specific types of protec on according to the applicable standard [ ] for associated apparatus

Equipment Protec on Level 

0575  II  1  G  14  023 

European Community Manufactured according to

applicable EC Direc ves

Marking for equipment

used in explosive atmospheres

Equipment Category Mines M1 Very High protec on M2 High protec on

Non 1 Very high protec on Mines 2 High protec on 3 Normal protec on ( ) for associated apparatus

No fied/Accredited Body  who has released

cer fica on

Cer fica on Number 

Progressive

Year  of issuing 

ATEX Direc ve 94/9/EC 

Supplementary le er X: Par cular condi ons

of use U: Component

IIC  T4 Ex  ia  Ga 

94/9/EC M

arking 

No fied Body number for produc on surveillance

Equipment Group I for Mines,

II different from Mines

Type of protec on

Gas Group 

0019 

X BVS  14  .

ATEX cer ficate 

IECEx cer ficate 

CENELEC/IEC standard marking

Hazardous  Atmospheres 

G: Gas, Vapour, Mist D: Dust

BVS 

IECEx 

ATEX 

IECEx Scheme 

Type of protec on  Concept  Code  EPL IEC /CENELEC  standard 

US Division Standard 

US Zone Standard 

Canadian Div.  Standard 

Canadian Zone Standard 

Gas General requirements ‐ ‐ 60079‐0 FM3600 60079‐0 ‐ 60079‐0

Intrinsic Safety Energy

limita on

Ex ia Ex ib Ex ic

Ga or Ma Gb or Mb

Gc 60079‐11 FM3610/UL913 60079‐11 C22.2 No. 157 60079‐11

Intrinsically Safe systems Energy

limita on

Ex ia Ex ib Ex ic

Ga Gb Gc

60079‐25 ‐ ‐ ‐ ‐

Increased Safety

Non sparking

Ex e Gb or Mb 60079‐7 ‐ 60079‐7 ‐ 60079‐7

Type n (non sparking/non incendive)

Ex nA Ex nC

Gc 60079‐15 FM3611 60079‐15 C22.2 No. 213 60079‐15

Flameproof / Expl. Proof

Explosion containment

Ex d Gb or Mb 60079‐1 FM3615/UL1203 60079‐1 C22.2 No. 30 60079‐1

Powder filling Ex q Gb or Mb 60079‐5 ‐ 60079‐5 ‐ 60079‐5

Type n (enclosed‐break)

Ex nC Gc 60079‐15 FM3611 60079‐15 C22.2 No. 213 60079‐15

Encapsula on

Separa on of explosive atmosphere from igni on

Ex ma Ex mb Ex mc

Ga or Ma Gb or Mb

Gc 60079‐18 ‐ 60079‐18 ‐ 60079‐18

Type n (sealed/herme cally sealed)

Ex nC Gc 60079‐15 FM3611 60079‐15 C22.2 No. 213 60079‐15

Pressuriza on

Ex pv Ex px Ex py Ex pz

Gb or Gc Gb or Mb

Gb Gc

60079‐2 FM3620/ NFPA 496

‐ ‐ 60079‐2

Oil immersion Ex o Gb 60079‐6 ‐ 60079‐6 ‐ 60079‐6

Type n (restricted breathing)

Ex nR Gc 60079‐15 ‐ ‐ ‐ 60079‐15

Special requirements ‐ Ga 60079‐26 ‐ ‐ ‐ ‐

Dust 

Intrinsic Safety Energy

limita on

Ex ia Ex ib Ex ic

Da Db Dc

60079‐11 FM3610/UL913 60079‐11 C22.2 No. 157 60079‐11

Dust igni on proof

Separa on of explosive atmosphere from igni on

Ex ta Ex tb

Da Db

60079‐31

FM3616/UL1203 ‐

C22.2 No. 25

Dust ght Ex tc Dc FM3611/

ANSI/ISA 12.12.01 ‐

Encapsula on Ex ma Ex mb Ex mc

Da Db Dc

60079‐18 ‐ 60079‐18 ‐ 60079‐18

Pressuriza on Ex pD Db or Dc 61241‐4 NFPA 496 ‐ ‐ 61241‐4

60079‐31

E A G D E A

IP (IEC/EN 60529) 

First numeral Protec on against solids 

Second numeral Protec on against water 

0 No protec on 0 No protec on

1 Greater than 50 mm 1 Ver cal dripping

2 Greater than 12,5 mm 2 Angled dripping (15°)

3 Greater than 2,5 mm 3 Spraying

4 Greater than 1 mm 4 Splashing

5 Dust protected 5 Je ng

6 Dust ght 6 Powerful je ng

7 Temporary immersion

8 Con nuous immersion

Nema (Standards Publica on 250)  

Type  Applica on  Protec on against 

1 Indoor General purpose

2 Indoor Dripping water, falling dust

3, 3R, 3S Outdoor Rain, snow, windblown dust

4, 4X Indoor / Outdoor Hose‐Directed water, Corrosion (X)

5 Indoor Angled dripping water, se ling dust

6 Indoor / Outdoor Temporary Submersion

6P Indoor / Outdoor Prolonged Submersion

7 Indoor Hazardous Loca on Class I

8 Indoor / Outdoor Hazardous Loca on Class I

9 Indoor Hazardous Loca on Class II

12, 12K Indoor Dripping non‐corrosive liquid, Dust

13 Indoor Water, oil, dust, seepage

P D

Atmosphere  Class *  Division *  Zone **  Area Classifica on 

Gas Class I Div. 1

Zone 0 Con nuous Hazard

Zone 1 Intermi ent Hazard

Div. 2 Zone 2 Abnormal Condi ons Hazard

Dust Class II Div. 1

Zone 20 Con nuous Hazard

Zone 21 Intermi ent Hazard

Div. 2 Zone 22 Abnormal Condi ons Hazard

Fiber Class III Div. 1

Zone 20 Con nuous Hazard

Zone 21 Intermi ent Hazard

Div. 2 Zone 22 Abnormal Condi ons Hazard

* according to NEC 500 / CEC Annex J;    ** according to IEC / NEC 505 / CEC 18 

D / Z

Atmosphere  Class *  Group *  Group **  Representa ve element 

Gas Class I

‐ Group I Methane

Group D Group IIA Propane

Group C Group IIB Ethylene

Group B Group IIC (except C2H2) Hydrogen

Group A Group IIC Acetylene

Dust Class II

Group G Group IIIB Non‐conduc ve dusts

Group F Group IIIB Carbonaceous dusts

Group E Group IIIC Metal dusts

Fiber Class III ‐ Group IIIA Fibers or flyings

 * according to NEC 500 / CEC Annex J;    ** according to IEC / NEC 505 / CEC 18 

G

 Combined equipment desired category 

1 / M1  2 / M2  3 

2 ‐ ‐

‐ ‐

‐ ‐

1 HFT 0 SIL 1

‐ ‐

‐ ‐

0 HFT 1 SIL 2

HFT 0 SIL 1

‐ ‐

 “‐” means that no safety device is required.  “SIL 1” or “SIL 2” is required Safety Integrity Level of safety related device according to EN 61508.  

Fault Tolerance of Equipment 

(number of single faults that cause the 

apparatus to fail)

M SIL ATEX (EN 50495)

G.M. INTERNATIONAL S.R.L Via San Fiorano, 70 20852 Villasanta (MB) ‐ ITALY phone: +39 039 2325038 [email protected] www.gmintsrl.com 

ATEX IECE : G , C , Z EPL

Defini on Explosive 

atmosphere 

 94/9/EC  (ATEX)  

99/92/EC  (ATEX) 

IECEx  

  Group Equipment  Category 

Area  classifica on 

Group  EPL 

Place where an explosive atmosphere is frequently

or for long periods or con nuously present

Coal mine   I M1 ‐ I Ma

Gas   II 1G Zone 0 * II Ga

Dust   II 1D Zone 20 ** III Da

Place where an explosive atmosphere is

occasionally present during normal opera on

Coal mine   I M2 ‐ I Mb

Gas   II 2G Zone 1 * II Gb

Dust   II 2D Zone 21 ** III Db

Place where an explosive atmosphere is not present during normal opera on,

and eventually for short periods

Gas   II 3G Zone 2 * II Gc

Dust   II 3D Zone 22 ** III Dc

 * according to IEC/EN 60079‐10‐1;    ** according to IEC/EN 60079‐10‐2 

Protec on Level 

Very High two independent

means of protec on or one protec on

allowing two independent faults

High single mean of

protec on allowing only one fault

Normal safe during

normal opera on

Field Equipment: 

SIMPLE APPARATUS: 

Less than 1.5 V; 0.1 A; 20 μJ; 25 mW (TC, RTD, Pot, Switch...). Simple apparatus is considered not to require cer fica on by a no fied body; cer fica on to the ATEX Direc ve is not required because of the low levels of energy, which are added to the intrinsically safe circuit by this apparatus. A simple apparatus is required to be clearly iden fied when it is installed. Simple apparatus shall conform to all relevant requirements of the standard.

INTRINSICALLY SAFE APPARATUS: 

Requires cer fica on. (TX, I/P, Solenoid Valve, Proximity, Field Display...)

Safety Parameters to be matched by Associated Apparatus:

Ui / Vmax (Max. Input Voltage); Ii / Imax (Max. Input Current);

Pi (Max. Input Power); Ci (Internal Capacitance); Li (Internal Inductance)

Control Room Equipment: 

ASSOCIATED APPARATUS: 

Requires cer fica on.

(Galvanic Isolators, Zener Barriers, Signal Condi oners)

Safety Parameters to be matched with Intrinsically Safe Apparatus:

Uo / Voc (Open Circuit Voltage); Io / Isc (Short Circuit Current);

Po (Max. Output Power); Co / Ca (Allowed Capacitance);

Lo / La (Allowed Inductance);

NON INTRINSICALLY SAFE APPARATUS: 

All Apparatuses without Approval (PLC, DCS, Computers, Controllers...)

E IS A

Max surface Temperature 

T class *  T class ** 

450 °C T1 T1

300 °C

280 °C

260 °C

230 °C

215 °C

T2

T2A

T2B

T2C

T2D

T2

200 °C

180 °C

165 °C

160 °C

T3

T3A

T3B

T3C

T3

135 °C

120 °C

T4

T4A

100 °C T5 T5

85 °C T6 T6

* according to NEC 500 / CEC Annex J ** according to IEC / NEC 505 / CEC 18 

T4

T C

Op on A: (Zone System ‐ NEC 505 / CEC 18) 

Op on B: (Division System ‐ NEC 500 / CEC Annex J) 

Conformity to US requirements Explosion Protec on Protec on method

Class I  Zone 0  A  Ex  ia  IIC  T4 

Class I  Div 1  Groups A, B, C, D  T4 

Gas, Vapor or Fiber

Area Classifica on

M N A NEC / CEC

Temperature Class

Gas Group

Temperature Class

Gas Group

Gas, Vapor or Fiber

Area Classifica on