Porter Cable Instruction Manual

18
Pancake Compressor Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference. Model No. ______________________________________ Type ___________________________________________ Serial No. _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. Part No. A03787-043-0 ESPAÑOL: PÁGINA 19 FRANÇAISE : PAGE 37 To learn more about Porter-Cable visit our website at: http://www.porter-cable.com MODEL CFFN250N CFFN250B CFBN125A Copyright © 2004 Porter-Cable Corporation PROFESSIONAL POWER TOOLS

Transcript of Porter Cable Instruction Manual

Page 1: Porter Cable Instruction Manual

Pancake CompressorInstructionmanual

The Model and Serial No. plate is located on the mainhousing of the tool. Record these numbers in thespaces below and retain for future reference.

Model No. ______________________________________

Type ___________________________________________

Serial No. _______________________________________

IMPORTANTPlease make certain that the person who isto use this equipment carefully reads andunderstands these instructions beforestarting operations.

Part No. A03787-043-0

ESPAÑOL: PÁGINA 19FRANÇAISE : PAGE 37

To learn more about Porter-Cable visit our website at:

http://www.porter-cable.com

MODEL CFFN250NCFFN250BCFBN125A

Copyright © 2004 Porter-Cable Corporation

PROFESSIONAL POWER TOOLS

Page 2: Porter Cable Instruction Manual

2 - ENGA03787

SAFETY GUIDELINES - DEFINITIONS

Indicates an imminentlyhazardous situation

which, if not avoided, will result in deathor serious injury.

Indicates a potentiallyhazardous situation

which, if not avoided, could result indeath or serious injury.

Indicates a potentiallyhazardous situation

which, if not avoided, may result in minoror moderate injury.

Used without the safetyalert symbol indicates a

potentially hazardous situation which, ifnot avoided, may result in propertydamage.

This manual contains information that is important for you to know andunderstand. This information relates to protecting YOUR SAFETY andPREVENTING EQUIPMENT PROBLEMS. To help you recognize thisinformation, we use the symbols below. Please read the manual and payattention to these symbols.

IMPORTANT SAFETY INSTRUCTIONSSome dust created by power sanding, sawing, grinding,drilling, and other construction activities contains chemicals

known (to the State of California) to cause cancer, birth defects or otherreproductive harm. Some example of these chemicals are:● lead from lead-based paints● crystalline silica from bricks and cement and other masonry products● arsenic and chromium from chemically-treated lumberYour risk from these exposures varies, depending on how often you do this typeof work. To reduce your exposure to these chemicals: work in a well ventilatedarea, and work with approved safety equipment, always wear MSHA/NIOSHapproved, properly fitting face mask or respirator when using such tools.When using air tools, basic safety precautions should always be followed toreduce the risk of of personal injury.

Page 3: Porter Cable Instruction Manual

3 - ENG A03787

IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

Improper operation or maintenance of this product could result in serious injury andproperty damage. Read and understand all warnings and operation instructions beforeusing this equipment.

HAZARD

WARNING: Risk of explosion or fire

How To Prevent ItWhat Could Happen

It is normal for electrical contacts withinthe motor and pressure switch to spark.

If electrical sparks from compressorcome into contact with flammablevapors, they may ignite, causing fire orexplosion.

Restricting any of the compressorventilation openings will cause seriousoverheating and could cause fire.

Unattended operation of this productcould result in personal injury orproperty damage. To reduce the risk offire, do not allow the compressor tooperate unattended.

Always operate the compressor in a wellventilated area free of combustiblematerials, gasoline, or solvent vapors.

If spraying flammable materials, locatecompressor at least 20 feet away fromspray area. An additional length of hosemay be required.Store flammable materials in a securelocation away from compressor.

Never place objects against or on top ofcompressor. Operate compressor in anopen area at least 12 inches away fromany wall or obstruction that wouldrestrict the flow of fresh air to theventilation openings.Operate compressor in a clean, dry wellventilated area. Do not operate unitindoors or in any confined area.

Always remain in attendance with theproduct when it is operating.Always disconnect electrical power bymoving pressure switch lever to the offposition and drain tank daily or aftereach use.

Page 4: Porter Cable Instruction Manual

4 - ENGA03787

WARNING: Risk of Bursting

Air Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion and could cause property damage or serious injury.

How To Prevent ItWhat Could Happen

WARNING: Risk from Flying Objects

The compressed air stream can causesoft tissue damage to exposed skinand can propel dirt, chips, looseparticles, and small objects at highspeed, resulting in property damage orpersonal injury.

Always wear ANSI Z87.1 approved safetyglasses with side shields when using thecompressor.

Never point any nozzle or sprayertoward any part of the body or at otherpeople or animals.

Always turn the compressor off andbleed pressure from the air hose and tankbefore attempting maintenance, attachingtools or accessories.

HAZARD

HAZARD

Drain tank daily or after each use. If tankdevelops a leak, replace it immediatelywith a new tank or replace the entirecompressor.

Failure to properly drain condensedwater from tank, causing rust andthinning of the steel tank.

Modifications or attempted repairs to the tank.

Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure.

Never drill into, weld, or make anymodifications to the tank or itsattachments.

Excessive vibration can weaken the air tank and cause rupture or explosion

The tank is designed to withstand specificoperating pressures. Never makeadjustments or parts substitutions toalter the factory set operatingpressures.

For essential control of air pressure, youmust install a pressure regulator andpressure gauge to the air outlet (if notequipped) of your compressor. Follow theequipment manufacturersrecommendation and never exceed themaximum allowable pressure rating ofattachments. Never use compressor toinflate small low pressure objects suchas children’s toys, footballs,basketballs, etc.

ATTACHMENTS & ACCESSORIES:Exceeding the pressure rating of airtools, spray guns, air operatedaccessories, tires, and other inflatablescan cause them to explode or fly apart,and could result in serious injury.

How To Prevent ItWhat Could Happen

Page 5: Porter Cable Instruction Manual

5 - ENG A03787

WARNING: Risk to Breathing

WARNING: Risk of Electrical Shock

HAZARD

HAZARD

Your air compressor is powered byelectricity. Like any other electricallypowered device, If it is not usedproperly it may cause electric shock.

Repairs attempted by unqualifiedpersonnel can result in serious injuryor death by electrocution.

Electrical Grounding: Failure to provideadequate grounding to this productcould result in serious injury or deathfrom electrocution. See grounding instructions.

Never operate the compressor outdoorswhen it is raining or in wet conditions.Never operate compressor withprotective covers removed or damaged.

Any electrical wiring or repairs requiredon this product should be performed byauthorized service center personnel inaccordance with national and localelectrical codes.

Make certain that the electrical circuit towhich the compressor is connectedprovides proper electrical grounding,correct voltage and adequate fuseprotection.

The compressed air directly from yourcompressor is not safe for breathing.The air stream may contain carbonmonoxide, toxic vapors, or solidparticles from the tank. Breathing thesecontaminants can cause serious injuryor death.

Sprayed materials such as paint, paintsolvents, paint remover, insecticides,weed killers, may contain harmfulvapors and poisons.

Air obtained directly from the compressorshould never be used to supply air forhuman consumption. In order to use airproduced by this compressor for breathing,suitable filters and in-line safetyequipment must be properly installed. In-line filters and safety equipment used inconjunction with the compressor must becapable of treating air to all applicablelocal and federal codes prior to humanconsumption.

Work in an area with good crossventilation. Read and follow the safetyinstructions provided on the label orsafety data sheets for the materials youare spraying. Use a NIOSH/ MSHAapproved respirator designed for use withyour specific application.

How To Prevent ItWhat Could Happen

How To Prevent ItWhat Could Happen

Page 6: Porter Cable Instruction Manual

6 - ENGA03787

WARNING: Risk of Burns

Touching exposed metal such as thecompressor head or outlet tubes, canresult in serious burns.

Never touch any exposed metal partson compressor during or immediatelyafter operation. Compressor will remainhot for several minutes after operation.Do not reach around protective shroudsor attempt maintenance until unit hasbeen allowed to cool.

WARNING: Risk from Moving Parts

Never operate the compressor withguards or covers which are damaged orremoved.

Moving parts such as the pulley, flywheel,and belt can cause serious injury if theycome into contact with you or yourclothing.

WARNING: Risk of Falling

A portable compressor can fall from atable, workbench, or roof causingdamage to the compressor and couldresult in serious injury or death to theoperator.

Always operate compressor in a stablesecure position to prevent accidentalmovement of the unit. Never operatecompressor on a roof or other elevatedposition. Use additional air hose toreach high locations.

HAZARD

HAZARD

HAZARD

Any repairs required on this productshould be performed by authorizedservice center personnel.

Attempting to operate compressor withdamaged or missing parts or attemptingto repair compressor with protectiveshrouds removed can expose you tomoving parts and can result in seriousinjury.

How To Prevent ItWhat Could Happen

How To Prevent ItWhat Could Happen

How To Prevent ItWhat Could Happen

Page 7: Porter Cable Instruction Manual

7 - ENG A03787

Review and understand all instructionsand warnings in this manual.Become familiar with the operation andcontrols of the air compressor.Keep operating area clear of all persons,pets, and obstacles.Keep children away from the aircompressor at all times.Do not operate the product when fatiguedor under the influence of alcohol ordrugs. Stay alert at all times.Never defeat the safety features of thisproduct.Equip area of operation with a fireextinguisher.Do not operate machine with missing,broken, or unauthorized parts.

WARNING: Risk of Unsafe Operation

Unsafe operation of your air compressorcould lead to serious injury or death toyou or others.

HAZARD

WARNING: Risk of Serious Injury or Property Damage WhenTransporting Compressor

Oil can leak or spill and could result infire or breathing hazard; serious injury ordeath can result. oil leaks will damagecarpet, paint or other surfaces invehicles or trailers.

Always place COMPRESSOR on aprotective mat when transporting toprotect against damage to vehicle fromleaks. Remove COMPRESSOR fromvehicle immediately upon arrival at yourdestination.

(Fire, Inhalation, Damage to Vehicle Surfaces)

HAZARD

SAVE THESE INSTRUCTIONS

How To Prevent ItWhat Could Happen

How To Prevent ItWhat Could Happen

Page 8: Porter Cable Instruction Manual

8 - ENGA03787

GLOSSARY

DUTY CYCLE

Accessories for this unit are available at the store the unit was purchased.

ACCESSORIES

Become familiar with these termsbefore operating the unit.CFM: Cubic feet per minute.SCFM: Standard cubic feet perminute; a unit of measure of airdelivery.PSIG: Pounds per square inchgauge; a unit of measure of pressure.Code Certification: Products thatbear one or more of the followingmarks: UL, CUL, ETL, CETL, havebeen evaluated by OSHA certifiedindependent safety laboratories andmeet the applicable UnderwritersLaboratories Standards for Safety.Cut-In Pressure: While the motor isoff, air tank pressure drops as youcontinue to use your accessory.

When the tank pressure drops to acertain low level the motor will restartautomatically. The low pressure atwhich the motor automaticallyrestarts is called "cut-in" pressure.Cut-Out Pressure: When an aircompressor is turned on and beginsto run, air pressure in the air tankbegins to build. It builds to a certainhigh pressure before the motorautomatically shuts off - protectingyour air tank from pressure higherthan its capacity. The high pressureat which the motor shuts off is called"cut-out" pressure.Branch Circuit: Circuit carryingelectricity from electrical panel tooutlet.

This air compressor pump is capableof running continuously. However, toprolong the life of your aircompressor, it is recommended that a

50%-75% average duty cycle bemaintained; that is, the air compressorpump should not run more than 30-45minutes in any given hour.

SPECIFICATIONS

Model Nos. CFFN250N, CFFN250B, CFBN125A

Horsepower Peak 2.0Bore 1.875"Stroke 1.250"Voltage-Single Phase 120Minimum Branch Circuit Requirement 15 ampsFuse Type Time DelayAir Tank Capacity (Gallon) 6Approximate Cut-in Pressure 110 PSIGApproximate Cut-out Pressure 135 PSIGSCFM @ 40 PSIG 3.7SCFM @ 90 PSIG 2.6

Page 9: Porter Cable Instruction Manual

9 - ENG A03787

ASSEMBLYUnpacking1. Remove unit from carton and discard all packaging.

2. Make sure the outlet being usedhas the same configuration asthe grounded plug. DO NOT USEAN ADAPTER. See illustration.

3. Inspect the plug and cord beforeeach use. Do not use if there aresigns of damage.

4. If these grounding instructionsare not completely understood,or if in doubt as to whether thecompressor is properlygrounded, have the installationchecked by a qualifiedelectrician.

Risk of ElectricalShock. IMPROPER

GROUNDING CAN RESULT INELECTRICAL SHOCK.Do not modify the plug provided. Ifit does not fit the available outlet, acorrect outlet should be installedby a qualified electrician.Repairs to the cord set or plugMUST be made by a qualifiedelectrician.

GROUNDING INSTRUCTIONSRisk of Electrical

Shock. In the eventof a short circuit, groundingreduces the risk of shock byproviding an escape wire for theelectric current. This aircompressor must be properlygrounded.The portable air compressor isequipped with a cord having agrounding wire with an appropriategrounding plug (see followingillustrations). 1. The cord set and plug with this

unit contains a grounding pin.This plug MUST be used with agrounded outlet.

IMPORTANT: The outlet being usedmust be installed and grounded inaccordance with all local codes andordinances.

INSTALLATIONHOW TO SET UP YOUR UNIT

Grounding Pin

GroundedOutlets

Plug

Location of the Air Compressor� Locate the air compressor in a

clean, dry and well ventilatedarea.

� The air compressor should belocated at least 12" away fromthe wall or other obstructions thatwill interfere with the flow of air.

� The air compressor pump andshroud are designed to allow forproper cooling. The ventilationopenings on the compressor arenecessary to maintain properoperating temperature. Do notplace rags or other containers onor near these openings.

Page 10: Porter Cable Instruction Manual

10 - ENGA03787

Extension CordsUsing extension cords is notrecommended. The use of extensioncords will cause voltage to dropresulting in power loss to the motorand overheating.Instead of using an extension cord,increase the working reach of the airhose by attaching another length ofhose to its end. Attach additionallengths of hose as needed.If an extension cord must be used, besure it is:

• a 3-wire extension cord that hasa 3-blade grounding plug, and a3-slot receptacle that will acceptthe plug on the product

• in good condition

• no longer than 50 feet

• 14 gauge (AWG) or larger. (Wiresize increases as gauge numberdecreases. 12 AWG and 10AWG may also be used. DONOT USE 16 OR 18 AWG.)

Voltage and Circuit ProtectionRefer to the specification chart for thevoltage and minimum branch circuitrequirements.

Certain aircompressors can be

operated on a 15 amp circuit if thefollowing conditions are met. 1. Voltage supply to circuit must

comply with the NationalElectrical Code.

2. Circuit is not used to supply anyother electrical needs.

3. Extension cords comply withspecifications.

4. Circuit is equipped with a 15 ampcircuit breaker or 15 amp timedelay fuse. NOTE: If compressoris connected to a circuitprotected by fuses, use only timedelay fuses. Time delay fusesshould be marked "D" in Canadaand "T" in the US.

If any of the above conditions cannotbe met, or if operation of thecompressor repeatedly causesinterruption of the power, it may benecessary to operate it from a 20 ampcircuit. It is not necessary to changethe cord set.

Page 11: Porter Cable Instruction Manual

Outlet Pressure Gauge: The outletpressure gauge indicates the airpressure available at the outlet side ofthe regulator. This pressure iscontrolled by the regulator and isalways less than or equal to the tankpressure. Regulator: Controls the air pressureshown on the outlet pressure gauge.Turn regulator knob clockwise toincrease pressure andcounterclockwise to decreasepressure. Universal Quick-Connect Body:The universal quick-connect bodyaccepts the three most popular stylesof quick-connect plugs: Industrial,automotive (Tru-flate), and ARO. Onehand push-to-connect operationmakes connections simple and easy. Cooling System (not shown): Thiscompressor contains an advanceddesign cooling system. At the heart ofthis cooling system is an engineeredfan. It is perfectly normal for this fanto blow air through the vent holes inlarge amounts. You know that thecooling system is working when air isbeing expelled.

11 - ENG A03787

On/Auto/Off Switch

Safety ValvePressureSwitch

TankPressureGauge Outlet

PressureGauge

Regulator

QuickConnect

Description of OperationBecome familiar with these controlsbefore operating the unit.On/Auto/Off Switch: Turn this switchON to provide automatic power to thepressure switch and OFF to removepower at the end of each use.Pressure Switch: The pressureswitch automatically starts the motorwhen the air tank pressure dropsbelow the factory set "cut-in"pressure. It stops the motor when theair tank pressure reaches the factoryset "cut-out" pressure.Safety Valve: If the pressure switchdoes not shut off the air compressorat its "cut-out" pressure setting, thesafety valve will protect against highpressure by "popping out" at itsfactory set pressure (slightly higherthan the pressure switch "cut-out"setting).Tank Pressure Gauge: The tankpressure gauge indicates the reserveair pressure in the tank.

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATINGYOUR UNIT. Compare the illustrations with your unit to familiarize yourself withthe location of various controls and adjustments. Save this manual for futurereference.

Page 12: Porter Cable Instruction Manual

Before Starting Break-in Procedure

Risk of UnsafeOperation. Serious

damage may result if the followingbreak-in instructions are not closely followed.This procedure is required before theair compressor is put into service andwhen the check valve or a completecompressor pump has been replaced.

1. Make sure the On/Auto/Off leveris in the "OFF" position.

NOTE: Pull coupler back until it clicksto prevent air from escaping throughthe quick connect.

2. Plug the power cord into thecorrect branch circuit receptacle.(Refer to Voltage and CircuitProtection paragraph in theInstallation section of thismanual.)

3. Open the drainvalve fully to permitair to escape andprevent airpressure build upin the air tank during the break-inperiod.

4. Move the On/Auto/Off lever to"ON/AUTO" position. Thecompressor will start.

5. Run the compressor for 15minutes. Make sure the drainvalve is open and there isminimal air pressure build-up intank.

6. After 15 minutes,close the drainvalve. The airreceiver will fill to"cut-out" pressureand the motor willstop.

The compressor is now ready for use.

Air Compressor Pump (not shown):Compresses air into the air tank.Working air is not available until thecompressor has raised the air tankpressure above that required at the airoutlet.Drain Valve: The drain valve islocated at the base of the air tank andis used to drain condensation at theend of each use.

Check Valve: When the aircompressor is operating, the checkvalve is "open", allowing compressedair to enter the air tank. When the aircompressor reaches "cut-out"pressure, the check valve "closes",allowing air pressure to remain insidethe air tank.

12 - ENGA03787

Check Valve

Open DrainValve

Closed DrainValve

Drain Valve

How to Use Your UnitHow to Stop:

1. Set the On/Auto/Off lever to"OFF".

Page 13: Porter Cable Instruction Manual

13 - ENG A03787

Before Each Start-Up:

1. Place On/Auto/Off lever to"OFF".

2. Turn the regulator knob counter-clockwise to set the outletpressure to zero.

3. Attach hose and accessories.

NOTE: The hose or accessory willrequire a quick connect plug if the airoutlet is equipped with a quickconnect socket.

How to Start:

1. Turn the On/Auto/Off lever to"AUTO" and allow tank pressureto build. Motor will stop whentank pressure reaches "cut-out"pressure.

2. Turn regulator knob clockwise toincrease pressure and stop whendesired pressure is reached.

The compressor is ready for use.

Risk of Bursting. Toomuch air pressure

causes a hazardous risk ofbursting. Check the manufacturer’smaximum pressure rating for airtools and accessories. Theregulator outlet pressure mustnever exceed the maximumpressure rating.

MAINTENANCECustomer Responsibilities

Daily oraftereachuse

Beforeeachuse

Check Safety Valve

Drain Tank

NOTE: See "Operation" section forthe location of controls.

Unit cyclesautomatically when

power is on. When performingmaintenance, you may be exposedto voltage sources, compressedair, or moving parts. Personalinjuries can occur. Beforeperforming any maintenance orrepair, disconnect power sourcefrom the compressor and bleed offall air pressure.

To Check Safety ValveIf the safety valve

does not workproperly, over-pressurization mayoccur, causing air tank rupture oran explosion. 1. Before starting compressor, pull

the ring on the safety valve tomake sure that the safety valveoperates freely. If the valve isstuck or does not operatesmoothly, it must be replacedwith the same type of valve.

Page 14: Porter Cable Instruction Manual

14 - ENGA03787

To Drain Tank1. Set the On/Auto/Off lever to

"OFF".

2. Turn the regulator knob counter-clockwise to set the outletpressure to zero.

3. Remove the air tool or accessory.

4. Pull ring on safety valve allowingair to bleed from the tank untiltank pressure is approximately20 psi. Release safety valve ring.

5. Drain water fromair tank by openingdrain valve onbottom of tank.

Water will condensein the air tank. If not

drained, water will corrode andweaken the air tank causing a riskof air tank rupture.

6. After the water hasbeen drained, closethe drain valve. Theair compressor cannow be stored.

NOTE: If drain valve isplugged, release all air pressure. Thevalve can then be removed, cleaned,the reinstalled.

Open DrainValve

Closed DrainValve

To Replace or Clean CheckValve 1. Release all air pressure from air

tank. See "To Drain Tank" in theMaintenance section.

2. Unplug unit.

3. Remove the hose by removingthe hose clamp. NOTE: The hoseclamp is not reusable. You mustpurchase a new hose clamp, seethe Parts List Manual or purchasea standard hose clamp at a localhardware store.

SERVICE AND ADJUSTMENTS

Risk of Unsafe Operation. Unit cycles automatically whenpower is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unitunplug or disconnect electrical supply to the air compressor, bleed tank ofpressure, and allow the air compressor to cool.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BEPERFORMED BY TRAINED SERVICE TECHNICIAN.

4. Unscrew the check valve (turncounter-clockwise) using asocket wrench.

CheckValve

Hose Clamp

Page 15: Porter Cable Instruction Manual

5. Make sure the valve disc movesfreely inside the check valve andthe spring holds the disc in theupper, closed position. Thecheck valve may be cleaned witha solvent, such as paint andvarnish remover.

6. Apply sealant to the check valvethreads. Reinstall the check valve(turn clockwise).

7. Replace hose and new hoseclamp.

8. Perform the Break-in Procedure.See "Break-in Procedure" in theOperation section.

15 - ENG A03787

In closed positiondisc is visible.

In openpositionnothing isvisible.

Screwdriver

5. Apply pipe sealant tape to thenipple on the standpipe.

6. Assemble the regulator andorient as shown.

NOTE: Arrow indicates flow of air.Make sure it is pointing in thedirection of air flow.

7. Reapply pipe sealant to outletpressure gauge and quickconnect.

8. Reassemble outlet pressuregauge and quick connect. Orientoutlet pressure gauge to readcorrectly. Tighten connect withwrench.

To Replace Regulator1. Release all air pressure from air

tank. See "To Drain Tank" in theMaintenance section.

2. Unplug unit.

3. Using an adjustable wrenchremove the outlet pressure gaugeand quick connect from theregulator.

4. Remove the regulator.

Nipple

OutletPressureGauge

Regulator

Regulator

QuickConnect

Arrow

Regulator

Page 16: Porter Cable Instruction Manual

16 - ENGA03787

STORAGE

Before you store the air compressor,make sure you do the following:

1. Review the "Maintenance"section on the preceding pagesand perform scheduledmaintenance as necessary.

2. Set the On/Auto/Off lever to"OFF" and unplug unit.

3. Turn the regulatorcounterclockwise and set theoutlet pressure to zero.

4. Remove the air tool or accessory.

5. Pull ring on safety valve allowingair to bleed from the tank untiltank pressure is approximately 20psi. Release safety valve ring.

6. Drain water from air tank byopening drain valve on bottom oftank.

Risk of Bursting.Water will condense

in the air tank. If not drained, waterwill corrode and weaken the air tankcausing a risk of air tank rupture.

7. After the water has been drained,close the drain or drain valve.

NOTE: If drain valve is plugged,release all air pressure. The valve canthen be removed, cleaned, thenreinstalled.

8. Protect the electrical cord and airhose from damage (such as beingstepped on or run over). Windthem loosely around thecompressor handle.

9. Store the air compressor in aclean and dry location.

Page 17: Porter Cable Instruction Manual

17 - ENG A03787

NOTES

Page 18: Porter Cable Instruction Manual

LIMITED WARRANTYPORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under thiswarranty are free from defects in material and workmanship. Products covered under this warranty include aircompressors, air tools, service parts, pressure washers, and generators, which have the following warrantyperiods:

3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM.2 YEARS - Limited warranty on oil-lubricated air compressor pumps. 1 YEAR - Limited warranty on all other air compressor components.2 YEARS - Limited warranty on electric generator alternators.1 YEAR - Limited warranty on other generator components.2 YEARS - Limited warranty on pneumatic air tools as described in Porter-Cable general catalog.1 YEAR - Limited warranty on pressure washers used in consumer applications (i.e. personal residentialhousehold usage only).90 DAY - Pressure washers used for commercial applications (income producing) and service parts.1 YEAR - Limited warranty on all accessories.

Porter-Cable will repair or replace, at Porter-Cable's option, products or components which have failedwithin the warranty period. Service will be scheduled according to the normal work flow and businesshours at the service center location, and the availability of replacement parts. All decisions of Porter-Cable Corporation with regard to this limited warranty shall be final.This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.RESPONSIBILITY OF ORIGINAL PURCHASER (initial User):• To process a warranty claim on this product, DO NOT return it to the retailer. The product must be

evaluated by a Porter-Cable Authorized Warranty Service Center. For the location of the nearest Porter-Cable Authorized Warranty Service Center call 1-888-559-8550, 24 hours a day, 7 days a week.

• Retain original cash register sales receipt as proof of purchase for warranty work.• Use reasonable care in the operation and maintenance of the product as described in the Owners

Manual(s).• Deliver or ship the product to the nearest Porter-Cable Authorized Warranty Service Center. Freight costs,

if any, must be paid by the purchaser.• Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation. Contact the nearest

Porter-Cable Authorized Warranty Service Center that provides on-site service calls, for service callarrangements.

• If the purchaser does not receive satisfactory results from the Porter-Cable Authorized Warranty ServiceCenter, the purchaser should contact Porter-Cable.

THIS WARRANTY DOES NOT COVER:• Merchandise sold as reconditioned, used as rental equipment, and floor or display models.• Merchandise that has become damaged or inoperative because of ordinary wear, misuse*, cold, heat, rain,

excessive humidity, freeze damage, use of improper chemicals, negligence, accident, failure to operate theproduct in accordance with the instructions provided in the Owners Manual(s) supplied with the product,improper maintenance, the use of accessories or attachments not recommended by Porter-Cable, orunauthorized repair or alterations. * An air compressor that pumps air more than the recommended duty cycle during a one hour period maybe considered misuse.

• Repair and transportation costs of merchandise determined not to be defective.• Costs associated with assembly, required oil, adjustments or other installation and start-up costs.• Expendable parts or accessories supplied with the product which are expected to become inoperative or

unuseable after a reasonable period of use, including but not limited to sanding disks or pads, saw andshear blades, grinding stones, springs, chisels, nozzles, o-rings, air jets, washers and similar accessories.

• Merchandise sold by Porter-Cable which has been manufactured by and identified as the product ofanother company, such as gasoline engines. The product manufacturer's warranty, if any, will apply.

• ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAYRESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT COVERED BYTHIS WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequentialdamages, so the above limitation or exclusion may not apply to you.

• IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE.Some states do not allow limitations on how long an implied warranty lasts, so the above limitations maynot apply to you.

Porter-Cable CorporationJackson, TN USA1-888-559-8550