Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount...
-
Upload
marylou-gilbert -
Category
Documents
-
view
219 -
download
0
Transcript of Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount...
![Page 1: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/1.jpg)
![Page 2: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/2.jpg)
• Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV.
• Connected in parallel in groups of 7 to 9 turbines (daisey chained), then thru a metering cabinet, then to the 25Kv switch gear. There is an isolation breaker for each “phase” or string of 7 turbines.
• The power then passes thru the 25kv main bus breaker to the GSU in the substation, where it is stepped up to 115 Kv and goes out over WAPPA lines. There is relaying protection in the 25Kv switch gear.
• Blade length Micon 75’ Vestas 77’• Low Speed Micon 14/22 rpm Vestas 29 rpm• Rotor Weight Micon 30000 lb Vestas 16000 lb• Yaw deck height Micon 187’ Vestas 217’
![Page 3: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/3.jpg)
• Micon– Cut in speed 7 mph– Cut out speed 56 mph– Transfer from low to high speed occurs at 14
mph
• Vestas– Cut in speed 9 mph– Maximum output at 33 mph– Cut out speed 56 mph
![Page 4: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/4.jpg)
59.6
80
This picture shows a 2 MW wind turbine with a 80-meter (262 feet) diameter blades size.
Note the Boeing 747 jumbo jet next to the turbine
80 m.
How Big is a 2-MW How Big is a 2-MW Wind Turbine?Wind Turbine?
..
![Page 5: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/5.jpg)
![Page 6: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/6.jpg)
Renewable Energy - Wind
![Page 7: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/7.jpg)
![Page 8: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/8.jpg)
![Page 9: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/9.jpg)
Wind Turbine Foundation Behavior and Design ConsiderationsKirk Morgan, Eric Ntambakwa Garrad Hassan America, Inc
Footing Concrete Volume (yds^3) vs. Rated Power (MW)
0
100
200
300
400
500
600
1 1.5 2 2.5 3
Power (MW)
YD
s^
3
![Page 10: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/10.jpg)
![Page 11: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/11.jpg)
Wind speed effect on power output
• 14 mph vs 16 mph average wind speed
• 50% more power– (16*16*16)/(14*14*14) =- 1.49
![Page 12: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/12.jpg)
Existing MW MW Under Construction
43,542 7,979
State Existing MW
MW Under Construction
Rank (Existing)
Texas 10,145 486 1
Iowa 3,738 792 2
California 3,599 1,256 3
Minnesota 2,681 61 4
Illinois 2,438 563 5
Washington 2,356 343 6
Oregon 2,305 848 7
Colorado 1,800 0 8
Oklahoma 1,612 788 9
North Dakota 1,424 150 10
American Wind Energy Association
![Page 13: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/13.jpg)
![Page 14: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/14.jpg)
Ponnequin 09
![Page 15: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/15.jpg)
Ponnequin 09
![Page 16: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/16.jpg)
Ponnequin 09
![Page 17: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/17.jpg)
![Page 18: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/18.jpg)
![Page 19: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/19.jpg)
![Page 20: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/20.jpg)
![Page 21: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/21.jpg)
![Page 22: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/22.jpg)
![Page 23: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/23.jpg)
![Page 24: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/24.jpg)
![Page 25: Ponnequin turbines output voltage(580Von the Micon side, 690Von the Vestas side) to pad mount transformers. These step the voltage up to 25KV. Connected.](https://reader034.fdocuments.us/reader034/viewer/2022051418/5697c02c1a28abf838cd94af/html5/thumbnails/25.jpg)