PLUMBING FLOOR PLAN - NORTH -...

3
14 15 16 17 18 19 20 21 22 23 1,146 sqft OBBY/CORE B C D E F H McKINSTRY Co, LLC PLUMBING FLOOR PLAN - NORTH PLAN NORTH KEYED NOTES: P-1 SCALE: 1/8"=1'-0" PLUMBING FLOOR PLAN - NORTH INSTANTANEOUS HEATER INSTALLATION NOT TO SCALE WATER SERVICE ENTRANCE DETAIL NOT TO SCALE

Transcript of PLUMBING FLOOR PLAN - NORTH -...

Page 1: PLUMBING FLOOR PLAN - NORTH - Barcombarcom.cc/wp-content/uploads/2017/08/exxon-building-p-1-1.pdfplumbing floor plan - north instantaneous heater installation not to scale water service

14 15 16 17 18 19 20 21 22 23

1,146 sqft

LOBBY/CORE

B

C

D

E

F

H

McKI

NSTR

Y Co

, LLC

PLUMBING FLOOR PLAN - NORTH

PLAN NORTH

KEYED NOTES:

P-1

SCALE: 1/8"=1'-0"

PLU

MBIN

G FLO

OR PLAN

- N

ORTH

INSTANTANEOUS HEATER INSTALLATION

NOT TO SCALE

WATER SERVICE ENTRANCE DETAIL

NOT TO SCALE

AutoCAD SHX Text
STAIRS UP
AutoCAD SHX Text
STAIRS DOWN
AutoCAD SHX Text
W.KLEBERG AVE.KLEBERG AVE.
AutoCAD SHX Text
EXISTING HANDICAP PARKING
AutoCAD SHX Text
EXISTING HANDICAP PARKING
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
TP1
AutoCAD SHX Text
L2
AutoCAD SHX Text
WC2
AutoCAD SHX Text
2
AutoCAD SHX Text
P-3
AutoCAD SHX Text
%%USK2
AutoCAD SHX Text
EWH2 BELOW BELOW COUNTER
AutoCAD SHX Text
3"VTR
AutoCAD SHX Text
%%USK2
AutoCAD SHX Text
EXISTING WATER SERVICE
AutoCAD SHX Text
IEWH1
AutoCAD SHX Text
CORRIDOR 039
AutoCAD SHX Text
STORAGE VAULT 042
AutoCAD SHX Text
STORAGE VAULT 038
AutoCAD SHX Text
SERGEANT 038
AutoCAD SHX Text
BREAK ROOM 041
AutoCAD SHX Text
TROOPERS 045
AutoCAD SHX Text
OFFICE 048
AutoCAD SHX Text
DEPT. OF PUBLIC SAFETY 049
AutoCAD SHX Text
WAITING AREA 050
AutoCAD SHX Text
DRIVERS LICENSE 046
AutoCAD SHX Text
FOYER 047
AutoCAD SHX Text
OFFICE 052
AutoCAD SHX Text
STATE REP. 053
AutoCAD SHX Text
CHECK-IN 054
AutoCAD SHX Text
CORRIDOR 051
AutoCAD SHX Text
WAITING AREA 055
AutoCAD SHX Text
FOYER 058
AutoCAD SHX Text
COUNTER 037
AutoCAD SHX Text
IT 036
AutoCAD SHX Text
RR 035
AutoCAD SHX Text
STORAGE 034
AutoCAD SHX Text
CORRIDOR 031
AutoCAD SHX Text
USDA 033
AutoCAD SHX Text
CSR AREA 044
AutoCAD SHX Text
CORRIDOR 043
AutoCAD SHX Text
FOYER 029
AutoCAD SHX Text
LOBBY 001
AutoCAD SHX Text
CHECK IN/MONITOR 056
AutoCAD SHX Text
ELECTIONS 057
AutoCAD SHX Text
3"HD
AutoCAD SHX Text
EXISTING WATER METER TO REMAIN. EXISTING WATER SERVICE AND BACKFLOW PREVENTOR TO 2ND FLOOR TO REMAIN. PROVIDE NEW WATER METER TO SERVE 1ST FLOOR TENANT SPACE. RISE UP EXPOSED AND PROVIDE HOSE BIB AT PENETRATION TO BUILDING. REFER TO DETAIL THIS SHEET. PROVIDE DOUBLE CHECK VALVE ASSEMBLY (DCVA) IN VERTICAL RISE TO STRUCTURE. 2" CW DOWN TO CRAWL SPACE. 2" CW UP FROM CRAWL SPACE AND UP TO ABOVE CEILING (SHEET P-2). RAIN LEADER DOWN FROM 2ND FLOOR. COORDINATE COORDINATE REROUTE WITH ALL DISCIPLINES PRIOR TO COMMENCEMENT OF WORK AND ENSURE NO CONFLICTS WITH DUCTWORK, LIGHTING, SPRINKLER PIPING, CONDUIT, ETC. RAIN LEADER DOWN TO CRAWL SPACE AND RECONNECT TO EXISTING CONNECTION POINT. CONNECT TO NEAREST SANITARY SEWER IN CRAWL SPACE. 1-1/4" DOWN IN WALL WITH 1" TO WATER CLOSET AND 1/2" TO LAVATORY. 1/2" TRAP PRIMER TO 3" FLOOR DRAIN.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
TEXAS ACCESSIBILITY STANDARDS NOTES: PLUMBING CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS AND SECTIONS FOR TEXAS ACCESSIBILITY STANDARDS/AMERICANS WITH DISABILITIES ACT (TAS/ADA) FIXTURE MOUNTING HEIGHTS AND LOCATIONS OF LEVERS, VALVES, AND ALL APPURTENANCES REQUIRED AND NECESSARY FOR COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT, TEXAS ACCESSIBILITY ACT, AND ALL APPLICABLE GOVERNING AUTHORITIES. FAILURE TO CONFORM TO ARCHITECTURAL PLANS AND SECTIONS FOR TAS/ADA PLUMBING FIXTURES SHALL NOT RELIEVE CONTRACTOR OF RESPONSIBILITY TO INSTALL SAME ACCORDING TO TAS/ADA GUIDELINES AND ALL REWORK TO PROVIDE INSTALLATIONS CONFORMING TO TAS/ADA GUIDELINES SHALL BE DONE AT NO COST TO THE OWNER. GENERAL PLUMBING FIXTURE REQUIREMENTS: 1. ALL SINKS AND LAVATORIES SHALL HAVE .5 GPM FLOW ALL SINKS AND LAVATORIES SHALL HAVE .5 GPM FLOW RESTRICTOR IN LINE. 2. FURNISH STOP VALVES, P-TRAPS, AND ALL FURNISH STOP VALVES, P-TRAPS, AND ALL APPURTENANCES REQUIRED AND NECESSARY TO PROVIDE COMPLETE, FUNCTIONAL UNITS. MAKE ALL FINAL CONNECTIONS. COORDINATE WITH ARCHITECTURAL AND OTHER TRADES. 3. ALL COLORS PER ARCHITECT. ALL COLORS PER ARCHITECT. 4. INSULATE P-TRAP AND SUPPLY STOPS ON ALL ADA INSULATE P-TRAP AND SUPPLY STOPS ON ALL ADA COMPLIANT LAVATORIES AND SINKS WHERE PIPING IS EXPOSED. INSULATION IS NOT REQUIRED WHERE LAVATORY PROTECTIVE ENCLOSURES ARE USED. COORDINATE WITH ARCHITECTURAL. 5. OFFSET WATER CLOSET FLANGES ARE NOT PERMITTED. OFFSET WATER CLOSET FLANGES ARE NOT PERMITTED. GENERAL PLUMBING NOTES: 1. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. 2. ESTABLISH LOCATION, SIZE, CAPACITY, AND DEPTH OF ESTABLISH LOCATION, SIZE, CAPACITY, AND DEPTH OF ALL PLUMBING UTILITIES, FINISHED FLOOR ELEVATIONS, SITE GRADIENTS, AND AVAILABLE SLOPE PRIOR TO COMMENCE OF CONSTRUCTION. ADVISE OWNER'S REPRESENTATIVE OF ANY DESCREPANCES IN CONTRACT DOCUMENTS THAT WILL IMPEDE THE PROPER INSTALLATION AND PERFORMANCE OF PLUMBING SYSTEMS. 3. RECORD INVERT ELEVATIONS OF ALL EXTERIOR PIPING ON RECORD INVERT ELEVATIONS OF ALL EXTERIOR PIPING ON RECORD DRAWINGS. 4. ALL BURIED PIPE SHALL BE LOCATED IN A TRENCH ALL BURIED PIPE SHALL BE LOCATED IN A TRENCH FILLED WITH SELECT FILL MATERIAL COMPACTED TO 95% PROCTOR. 5. SLEEVE ALL PIPING PENETRATIONS OF FLOORS, WALLS, SLEEVE ALL PIPING PENETRATIONS OF FLOORS, WALLS, AND BEAMS IN ACCORDANCE WITH DETAILS AND SPECIFICATIONS. 6. INSTALL ALL PLUMBING SYSTEM SHUTOFF OR ZONE INSTALL ALL PLUMBING SYSTEM SHUTOFF OR ZONE VALVES IN ACCESSIBLE LOCATIONS IN VALVE BOXES, MECHANICAL ROOMS, ABOVE CEILINGS, OR AS SHOWN ON DRAWINGS. VALVES LOCATED ABOVE CEILINGS SHALL BE SAFELY ACCESSIBLE FROM A SIX FEET TALL STEP LADDER. PROVIDE OFFSETS, DROPS IN ELEVATION, AND ACCESS PANELS AS NECESSARY. COORDINATE EXACT LOCATIONS WITH OTHER TRADES PRIOR TO INSTALLATION. 7. FIELD ADJUSTMENT OF PLUMBING EQUIPMENT, FIXTURE FIELD ADJUSTMENT OF PLUMBING EQUIPMENT, FIXTURE AND PIPING MAY BE NECESSARY TO FIT FIELD CONDITIONS. COORDINATE WITH ARCHITECTURAL DRAWINGS AND OTHER TRADES. SUCH WORK SHALL BE COMPLETED AT NO COST TO THE OWNER, OWNER'S REPRESENTATIVE, OR DESIGN PROFESSIONALS. 8. FIELD COORDINATE ALL FLOOR PENETRATIONS WITH FIELD COORDINATE ALL FLOOR PENETRATIONS WITH STRUCTURAL ELEMENTS PRIOR TO COMMENCEMENT OF WORK. AVOID ALL STRUCTURAL BEAMS.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
D
AutoCAD SHX Text
KAI JOB NUMBER:
AutoCAD SHX Text
SPECIFICATIONS NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
XREFS:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
JOB #17069
AutoCAD SHX Text
SPEC #
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
SEQ #
AutoCAD SHX Text
100 E. KLEBERG
AutoCAD SHX Text
KINGSVILLE, TEXAS 78363
AutoCAD SHX Text
KLEBERG COUNTY ANNEX
AutoCAD SHX Text
FIRST FLOOR INTERIOR FINISH-OUT
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
S
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
L
AutoCAD SHX Text
S
AutoCAD SHX Text
A
AutoCAD SHX Text
X
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
65986
AutoCAD SHX Text
R. S. PITZER
AutoCAD SHX Text
DATED:%%U
AutoCAD SHX Text
08/04/17
AutoCAD SHX Text
1
AutoCAD SHX Text
Mechanical and
AutoCAD SHX Text
Electrical Consultants
AutoCAD SHX Text
5440 Old Brownsville Rd.
AutoCAD SHX Text
Corpus Christi, TX 78417
AutoCAD SHX Text
361 852 2342 vox
AutoCAD SHX Text
361 852 2343 fax
AutoCAD SHX Text
M
AutoCAD SHX Text
inc
AutoCAD SHX Text
Engineering
AutoCAD SHX Text
Firm Registration # F-02829
AutoCAD SHX Text
GPM
AutoCAD SHX Text
1
AutoCAD SHX Text
ISSUED FOR CONSTRUCTION
AutoCAD SHX Text
08-04-17
AutoCAD SHX Text
COMPRESSION FITTINGS (2)
AutoCAD SHX Text
HOT
AutoCAD SHX Text
COLD
AutoCAD SHX Text
MOUNTING FLANGES (4)
AutoCAD SHX Text
HOT OUTLET
AutoCAD SHX Text
COLD INLET MAIN
AutoCAD SHX Text
ANGLE STOP VALVE
AutoCAD SHX Text
1/2" THREE WAY
AutoCAD SHX Text
INLINE FLOW CONTROL "I"
AutoCAD SHX Text
INSTANT FLOW HEATER
AutoCAD SHX Text
SINK
AutoCAD SHX Text
COLD OUTLET
AutoCAD SHX Text
3/8" COPPER TUBING
AutoCAD SHX Text
J-BOX
AutoCAD SHX Text
%%UKEYED NOTES:
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
5
AutoCAD SHX Text
WATER SERVICE ENTRANCE DETAIL KEYED NOTES: 1. BALL VALVE BALL VALVE 2. TYPE "L" COPPER TYPE "L" COPPER 3. INSULATE AND COVER WITH INSULATE AND COVER WITH 0.16 ALUMINUM JACKET 4. SEAL SEAL 5. HOLD AS CLOSE TO WALL HOLD AS CLOSE TO WALL AS POSSIBLE 6. SLEEVE - 2" LARGER THAN SLEEVE - 2" LARGER THAN PIPE WITH SEALER 7. ROUTE PIPE IN WALL ROUTE PIPE IN WALL CAVITY. COORDINATE WITH ARCHITECTURAL FOR WALL TYPE. 8. HOSE BIBBHOSE BIBB
AutoCAD SHX Text
%%uFRONT VIEW
AutoCAD SHX Text
%%uSIDE VIEW
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
3
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
1
AutoCAD SHX Text
8
Page 2: PLUMBING FLOOR PLAN - NORTH - Barcombarcom.cc/wp-content/uploads/2017/08/exxon-building-p-1-1.pdfplumbing floor plan - north instantaneous heater installation not to scale water service

3

B

C

D

E

F

H

4 5 6 7 8 9 10 11 13122

1,146 sqft

LOBBY/CORE

McKI

NSTR

Y Co

, LLC

MECHANICAL FIRST FLOOR PLAN - SOUTH

PLAN NORTH

P-2

SCALE: 1/8"=1'-0"

PLU

MBIN

G FLO

OR PLAN

- SO

UTH

KEYED NOTES:

FLOOR SLEEVE DETAIL - GROUND FLOOR

NOT TO SCALE

WALL SLEEVE DETAIL

NOT TO SCALE

ELECTRIC WATER HEATER ON STAND W/ET

NOT TO SCALE

AutoCAD SHX Text
CHASE
AutoCAD SHX Text
EXISTING HANDICAP PARKING
AutoCAD SHX Text
EXISTING HANDICAP PARKING
AutoCAD SHX Text
W.KING AVE.KING AVE.
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
WC2
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC2
AutoCAD SHX Text
UR2
AutoCAD SHX Text
UR1
AutoCAD SHX Text
UR1
AutoCAD SHX Text
UR2
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC2
AutoCAD SHX Text
WC2
AutoCAD SHX Text
WC1
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
%%USK2
AutoCAD SHX Text
2"VTR
AutoCAD SHX Text
SS
AutoCAD SHX Text
1
AutoCAD SHX Text
P-3
AutoCAD SHX Text
3"VTR
AutoCAD SHX Text
%%USK1
AutoCAD SHX Text
LOBBY 001
AutoCAD SHX Text
ELEV. MACH. 028
AutoCAD SHX Text
LOBBY 002
AutoCAD SHX Text
MEN'S RR 003
AutoCAD SHX Text
WOMEN'S RR 004
AutoCAD SHX Text
MEN'S RR 025
AutoCAD SHX Text
WOMEN'S RR 024
AutoCAD SHX Text
WAITING AREA 005
AutoCAD SHX Text
RECEPTION DSHS 008
AutoCAD SHX Text
RECEPTION DSHS 010
AutoCAD SHX Text
PC STATIONS 006
AutoCAD SHX Text
CORRIDOR 011
AutoCAD SHX Text
MED STORAGE 009
AutoCAD SHX Text
OFFICE 022
AutoCAD SHX Text
DADS 012
AutoCAD SHX Text
MAIL ROOM 020
AutoCAD SHX Text
CORRIDOR 018
AutoCAD SHX Text
LAB/TESTING AREA 007
AutoCAD SHX Text
BREAK ROOM 019
AutoCAD SHX Text
CONF ROOM 021
AutoCAD SHX Text
CORRIDOR 023
AutoCAD SHX Text
JAN. 026
AutoCAD SHX Text
ELEC. 027
AutoCAD SHX Text
HHSC 013
AutoCAD SHX Text
OPEN FILE 017
AutoCAD SHX Text
IT/TELE 016
AutoCAD SHX Text
FILE ROOM 015
AutoCAD SHX Text
SUP. OFFICE 014
AutoCAD SHX Text
3"FD1
AutoCAD SHX Text
EDF1
AutoCAD SHX Text
EDF1
AutoCAD SHX Text
EWH1 (30 GAL)
AutoCAD SHX Text
CP1
AutoCAD SHX Text
3"HD
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
L1/TP1/TP1TP1
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
EXISTING WATER METER TO REMAIN. EXISTING WATER SERVICE AND BACKFLOW PREVENTOR TO 2ND FLOOR TO REMAIN. PROVIDE NEW WATER METER TO SERVE 1ST FLOOR TENANT SPACE. RISE UP EXPOSED AND PROVIDE HOSE BIB AT PENETRATION TO BUILDING. REFER TO DETAIL THIS SHEET. PROVIDE DOUBLE CHECK VALVE ASSEMBLY (DCVA) IN VERTICAL RISE TO STRUCTURE. 2" CW DOWN TO CRAWL SPACE. 2" CW UP FROM CRAWL SPACE AND UP TO ABOVE CEILING (SHEET P-2). RAIN LEADER DOWN FROM 2ND FLOOR. COORDINATE COORDINATE REROUTE WITH ALL DISCIPLINES PRIOR TO COMMENCEMENT OF WORK AND ENSURE NO CONFLICTS WITH DUCTWORK, LIGHTING, SPRINKLER PIPING, CONDUIT, ETC. RAIN LEADER DOWN TO CRAWL SPACE AND RECONNECT TO EXISTING CONNECTION POINT. CONNECT TO NEAREST SANITARY SEWER IN CRAWL SPACE. 1-1/4" DOWN IN WALL WITH 1" TO WATER CLOSET AND 1/2" TO LAVATORY. 1/2" TRAP PRIMER TO 3" FLOOR DRAIN.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SHEET SIZE
AutoCAD SHX Text
D
AutoCAD SHX Text
KAI JOB NUMBER:
AutoCAD SHX Text
SPECIFICATIONS NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
XREFS:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
JOB #17069
AutoCAD SHX Text
SPEC #
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
SEQ #
AutoCAD SHX Text
100 E. KLEBERG
AutoCAD SHX Text
KINGSVILLE, TEXAS 78363
AutoCAD SHX Text
KLEBERG COUNTY ANNEX
AutoCAD SHX Text
FIRST FLOOR INTERIOR FINISH-OUT
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
S
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
L
AutoCAD SHX Text
S
AutoCAD SHX Text
A
AutoCAD SHX Text
X
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
65986
AutoCAD SHX Text
R. S. PITZER
AutoCAD SHX Text
DATED:%%U
AutoCAD SHX Text
08/04/17
AutoCAD SHX Text
1
AutoCAD SHX Text
Mechanical and
AutoCAD SHX Text
Electrical Consultants
AutoCAD SHX Text
5440 Old Brownsville Rd.
AutoCAD SHX Text
Corpus Christi, TX 78417
AutoCAD SHX Text
361 852 2342 vox
AutoCAD SHX Text
361 852 2343 fax
AutoCAD SHX Text
M
AutoCAD SHX Text
inc
AutoCAD SHX Text
Engineering
AutoCAD SHX Text
Firm Registration # F-02829
AutoCAD SHX Text
GPM
AutoCAD SHX Text
1
AutoCAD SHX Text
ISSUED FOR CONSTRUCTION
AutoCAD SHX Text
08-04-17
AutoCAD SHX Text
WALL SLEEVE DETAIL KEYED NOTES: 1. MASONRY WALL. 2. GALVANIZED SCH 40 STEEL SLEEVE. SIZE TO BE MIN. 3/8" LARGER IN DIAMETER THAN PIPE AND INSULATION. 3. HVAC PIPE. 4. FILL VOID WITH MINERAL WOOL AND CAULK VERMIN TIGHT WHEN PENETRATING INTERIOR PARTITIONS. FILL VOID WITH FIRE RETARDANT PUTTY PER SPECIFICATIONS WHEN PENETRATING EXTERIOR MASONRY WALLS OR FIRE RATED PARTITIONS.
AutoCAD SHX Text
4
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
FLOOR SLEEVE DETAIL KEYED NOTES: 1. SANITARY WASTE AND VENT PIPING 2. SCH 40 PVC SLEEVE. SEAL ANNULUS WITH INTUMESCENT PUTTY. 3. GROUND FLOOR SLAB
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
NOTE: PROVIDE SLEEVE AT ALL SW&V PIPING PASSING THROUGH FLOORS.
AutoCAD SHX Text
R
AutoCAD SHX Text
ELECTRIC WATER HEATER DETAIL KEYED NOTES: 1. ELECTRIC WATER HEATER ELECTRIC WATER HEATER 2. WATTS REGULATOR E-100 WATER HEATER WATTS REGULATOR E-100 WATER HEATER RESTRAINER. COORDINATE WALL TYPE WITH ARCHITECTURAL. FIELD VERIFY. 3. 4" DEEP 24GA GALVANIZED AUXILIARY 4" DEEP 24GA GALVANIZED AUXILIARY DRAIN PAN 4. WATTS REGULATOR AS-30 WATER HEATER WATTS REGULATOR AS-30 WATER HEATER STAND, GALVANIZED STEEL, 16" HIGH. 5. TRAP PRIMER TRAP PRIMER 6. FLOOR SINK FLOOR SINK 7. TO DRAIN TO DRAIN 8. FLOOR FLOOR 9. AUX. PAN DRAIN 3/4" AUX. PAN DRAIN 3/4" 10. TANK DRAIN TANK DRAIN 11. WATER HEATER RELIEF LINE. SIZE PER WATER HEATER RELIEF LINE. SIZE PER MFR. RECOMMENDATIONS. 12. IF BOTTOM FED USE VACUUM BREAKER IF BOTTOM FED USE VACUUM BREAKER 13. UNION (TYPICAL) UNION (TYPICAL) 14. BALL VALVE (TYPICAL) BALL VALVE (TYPICAL) 15. EXPANSION TANK. SUPPORT FROM EXPANSION TANK. SUPPORT FROM STRUCTURE 16. REFER TO PLAN FOR SIZE REFER TO PLAN FOR SIZE 17. HEAT TRAPS PER IECC HEAT TRAPS PER IECC 18. ASME T&P RELIEF VALVEASME T&P RELIEF VALVE
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
Page 3: PLUMBING FLOOR PLAN - NORTH - Barcombarcom.cc/wp-content/uploads/2017/08/exxon-building-p-1-1.pdfplumbing floor plan - north instantaneous heater installation not to scale water service

ENLARGED MENS AND WOMENS RESTROOMS

PLAN NORTH

KEYED NOTES:

P-3

SCALE: 1/4"=1'-0"

ENLARGED RESTROOM 035

PLAN NORTH

SCALE: 1/4"=1'-0"

PLU

MBIN

G SCH

ED

ULES AN

D D

ETAILS

PLUMBING FIXTURE SCHEDULEPLUMBING LEGEND

WATER SAVER TRAP PRIMER DETAIL

NOT TO SCALE

TYPICAL RISER DIAGRAMS

NOT TO SCALE

PIPE HANGER DETAIL

NOT TO SCALE

FLOOR DRAIN SEALING DETAIL

NOT TO SCALE

WALL CLEANOUT DETAIL

NOT TO SCALE

2

1

Z:\2

01

7\1

70

69

_\P

LU

M\1

70

69

_P

lu

mb

in

g.d

wg

, 8

/7

/2

01

7 1

1:4

7:0

8 A

M, JW

AR

D