Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under...

117
Scan code for details & installation instructions 2017 Version 1.0 Plumbers’ Handbook ®

Transcript of Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under...

Page 1: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Scan code for details & installation

instructions

2017Version 1.0

Plumbers’Handbook

®

®

®

Page 2: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

22

To receive updates of the Rheem Plumbers’ Handbook

register at

rheem.com.au/trade-promotions

How to Download a QR Code Reader to your Mobile Device

Open your mobile app store (App Store, Google Play, Windows Marketplace, etc.)

Search for QR code reader. Check out the list of QR code readers for mobile phones to find the right one for you.

Simply download the QR code reader to your phone, open it and you are ready to scan the codes that appear in the Rheem Plumbers’ Handbook .

Page 3: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

3

Contents

Installation - Checklist

General 4

Electric Water Heaters/Heat Pump 5

Gas Water Heaters 6

Solar Water Heaters 7

Hot Water Recirculation Systems 8

Anode Selection & Water Supplies 9

Water Connections 11

Pipework and Pipe Sizing 14

Specific Applications 15

Electric Storage Models 17

Gas Storage Models 45

Gas Continuous Flow Models & Accessories 65

Solar Models 91

Heat Pump Models 111

Page 4: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

4

Water Heater position

Read the Installation Instructions, to familiarise yourself with the unit – the water heater must be installed, operated and maintained in accordance with the Owner’s Guide & Installation Instructions and local state regulations.

Water heaters must be installed and serviced by a qualified person.

Keep the tank vertical at all times during transport and installation. Not applicable to solar thermosiphon tanks or Stainless Steel water heaters.

Locate close to point of use or the most frequently used hot water outlet:

Closer to the most often used tap will help reduce running costs.

Minimising the length of hot water pipework reduces the time taken for hot water to reach the tap, heat loss and water wastage.

Leave headroom of approximately one water heater height to allow anode inspection and replacement (storage water heaters and hot water storage tanks). Not applicable to Stainless Steel water heaters.

Ensure controls can be easily operated.

Ensure serviceable parts such as TPR (temperature pressure relief) valve are accessible.

Ensure rating label/data plate can be easily read.

Ensure service access covers are easily removable.

For OUTDOOR storage water heaters:

Must be installed on a level plinth 50mm above surrounding ground. Gas storage units must be installed up against a wall or rigid vertical support via the brackets provided.

DO NOT place in direct contact with concrete that is less than 2 months old and not fully cured as this may attack the metal coating of the jacket. A moisture barrier between the two surfaces should be used in this instance.

Installation Checklist General

Page 5: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

5

Installation Checklist Electric Water Heaters/Heat Pump

Location

Water heaters installed in roof spaces – local authorities have regulations regarding such installations, so check with your local authorities.

Ensure the front covers, thermostats and elements can be removed for service.

Installation Standards & Safety

The water heater is supplied with a thermostat and a over-temperature cut-out and a combination temperature pressure relief valve (TPR). These devices MUST NOT be tampered with or removed, except for authorised service. The water heater must not be operated unless each of these devices is fitted and in working order.

Operation of the over-temperature cut-out indicates a possibly dangerous situation. Only reset the control after the cause of its operation has been determined and any fault corrected.

The water heater must be installed

By a qualified person

In accordance with the Installation Instructions and in compliance with Standards AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulations.

Safe Tray

Where property damage could occur in the event of a leak, the water heater must be installed in a safe tray

Safe tray construction, installation and draining must comply with AS/NZS 3500.4 and local codes/regulations; check all relevant requirements before installing.

Page 6: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

6

A flue of up to 150mm internal diameter must be 25mm clear of combustible materials such as timber walls and cupboards.

A flue exceeding 150mm internal diameter requires clearances of 75mm from unprotected surfaces and 50mm from protected surfaces.

Outdoor gas water heaters (all types) must have minimum clearances from the flue terminal to certain building features such as openable windows/doors and to fences/walls. Refer to AS/NZS 5601.1 for these clearances.

Leave clearance to allow removal of the burner assembly if required.

Leave adequate clearance on all sides for ventilation and safety and ensure flue terminal and air inlet are free from any obstruction (Gas storage and Continuous Flow).

Ensure the combustion air supply is not likely to be contaminated with substances that are corrosive or would become corrosive after passing through a flame.

Outdoor storage models must be installed against a wall or rigid vertical support.

Outdoor models must have free and balanced airflow at both the air intake and flue outlet.

Indoor water heaters require correct ventilation - check AS/NZS 5601.1 for requirements

Gas Continuous Flow

The high gas consumption of these water heaters often necessitates larger diameter gas supply pipe. Undersized pipe will affect performance and hot water capacity. Size the gas supply pipe using the MJ rating marked on the appliance.

Large capacity (27L/minute) Continuous Flow water heaters may, due to their gas consumption, require greater clearance distance from doors and windows – check AS/NZS 5601.1 requirements.

Installation Checklist Gas Water Heaters

Page 7: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

7

The correct type of solar water heater is to be selected for the area. Consideration must be given to whether freeze protection is required and to the chemistry of the water to be supplied to the water heater.

For a split system, consideration must also be given to the position of the collectors in relation to the solar storage tank. There are limitations on both the maximum length of the solar hot and solar cold pipes and the maximum height between the storage tank and the collectors. Refer to the installation instructions supplied with the product.

The collectors must be installed in a shade free position. The surrounds should be checked for higher buildings or trees which may cause shade at other times of the year and for small trees which may grow and shade collectors in the future.

The installation must comply with the requirements of either AS/NZS 3500.4 or AS/NZS 3500.5:2012 Section 3 (for a Class 1a or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

The installer must ensure the structural integrity of the building is not compromised by the solar water heater installation and the roof structure is suitable to carry the full weight of the collectors and frame (if one is installed). If in any doubt of the construction or the condition of the roof, the roof should be suitably strengthened. Consult a structural engineer.

Maximum performance is achieved with an orientation facing true north. Always check for true north using a compass or other suitable device.

The performance of a system reduces as the orientation of the collectors moves away from true north, resulting in the need for increased boosting to supply the same hot water load.

Where it is not possible or practical to install collectors facing north, they may be oriented up to 90° from north (subject to installation code requirements). It may be desirable to install an additional collector or higher performance collectors to help make up for the reduction in solar performance. Each option should be discussed with the system owner. If neither of these options is possible or acceptable to the system owner, then the system owner needs to be made aware of, understand and accept that increased boosting may be required to meet their hot water requirements.

Frames are available from Rheem to raise the inclination of the collectors, and for high wind (cyclone) areas.

Installation Checklist Solar Water Heaters

Page 8: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

8

When water heaters are installed on a hot water flow and return recirculation system, the following should be included:

A suitable pump correctly aligned, oriented and weather protected with a check valve and isolation valves.

To reduce energy costs a timer to activate circulation in periods of regular demand.

Suitable pipe insulation to minimise heat loss.

A Temperature Limiting Device positioned on individual branch lines to ablution areas, not in the main flow line to the building.

Where multiple water heater are manifolded, correct Equa-flow® principles must be followed.

Installation Checklist Hot Water Recirculation Systems

Page 9: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

9

Every Rheem water heater is manufactured to suit the water conditions of most public reticulated water supplies, but some water chemistries can have detrimental effects on the water heater’s operation and life expectancy.

Ask the local Water Supply Authority for information on the water chemistry, which you can check against the Rheem guidelines below.

A water heater cylinder or heat exchanger can be affected by the chemistry of the water supply. The cylinder of the water heater is only covered by Rheem warranty when the total dissolved solids (TDS) in the water supply is below 2500mg/L and the correct colour anode is used. Using the wrong coloured anode may also shorten the life of the cylinder.

Use the following table to select the correct colour anode to be fitted:

Total Dissolved Solids Anode colour code

0 - 40 mg/L Green

40 - 150 mg/L Green or Black

150 - 400 mg/L Black

400 - 600 mg/L Black or Blue

600 - 2500 mg/L Blue

2500 mg/L + Blue (no cylinder warranty)

The anode will slowly dissipate over time while protecting the cylinder. The life of the cylinder may be extended by replacing the anode.

If the anode is not replaced at the 5 year service, the maximum time when it should be replaced is not more than 8-10 years (depending upon the model – refer to the Owner’s Guide & Installation Instructions).

For water supplies that are softened, desalinated or where the water supply may alternate between tank water and reticulated public supply or another supply, it is recommended the anode be replaced within 5 years of installation and every 5 years thereafter.

Saturation Index is a measure of the water’s corrosive or scaling properties. A corrosive water supply can attack copper components. Where the saturation index is less than -1.0:

Water is very corrosive

A corrosion resistant element must be used for the Rheem warranty to cover the element

Anode Selection & Water Supplies

Page 10: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

10

Anode Selection & Water Supplies - cont’d

In a scaling water supply calcium carbonate is deposited onto any hot metallic surface.

Where the saturation index exceeds +0.4:

Water is very scaling

An expansion control valve must be fitted on the cold water line after the non-return valve for the Rheem warranty to cover the cylinder and TPR valve

Where the saturation index exceeds +0.8:

Rheem warranty does not cover a standard watts density element

A low watts density element must be used for the Rheem warranty to cover the element

Stainless Steel cylinders are not suitable for installation in some areas, where water chemistry is such that the cylinder can be affected. Installation in these areas may void the cylinder warranty.

Before installing, check the Rheem website for suitable installation areas: www.rheem.com.au/stellar

+0.4 +0.80

very corrosive very scalingscalingcorrosive

-1.0

SATURATION INDEX (SI)WATER HEATERS

WITHIN WARRANTYSPECIFICATION

SATURATION INDEX(calculated @ 80°C water temperature)

no w

arra

nty

appl

ies

to a

: te

mpe

ratu

re p

ress

ure

relie

f val

ve o

r aw

ater

hea

ter c

ylin

der u

nles

s an

expa

nsio

n co

ntro

l val

ve is

fitte

d.

no w

arra

nty

appl

ies

to a

:- s

tand

ard

wat

ts d

ensi

ty e

lem

ent

- dire

ct (o

pen

circ

uit)

sola

r col

lect

or- h

eat p

ump

heat

exc

hang

er- s

tain

less

ste

el c

ylin

der

- con

tinuo

us fl

ow c

oppe

r hea

t exc

hang

er

no w

arra

nty

appl

ies

to a

:- s

tand

ard

wat

ts d

ensi

ty e

lem

ent

- dire

ct (o

pen

circ

uit)

sola

r col

lect

or- h

eat p

ump

heat

exc

hang

er- s

tain

less

ste

el c

ylin

der

- con

tinuo

us fl

ow c

oppe

r hea

t exc

hang

er

Page 11: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

11

Water Connections

Cold Water Connection191025

The following may be required on the cold water inlet pipework (see figure below for order of installation)Isolating Valve Also known as a stop cock

Required for service and maintenance

Non-Return Valve Also known as a check valveSoft seat type preferredLocated between stop cock and water heaterDo not fit to inlet of continuous flow water heater

Duo Valve Combination isolating and non return valveCan be used instead of two separate valves

Pressure Limiting or Pressure Reducing Valve

Required if supply pressure is likely to exceed 80% of relief valve setting.Recommended use on supply to the entire building to ensure same pressure of cold and hot water

Expansion Control Valve Required for all storage water heaters in QLD, WA, SA and any other area where the water supply has a saturation index exceeding +0.4Last valve before water heater

Disconnecting Union Final fitting on the cold water plumbing.

Expansion ControlValve

Pressure LimitingValve

Non-ReturnValve

Stopcock

To UnionConnector

Page 12: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

12

Hot Water Connection191025

The following are required for the hot water outletTemperature Limiting Device/Tempering Valve/ Thermostatic mixing valve

Required for bathrooms, basins, not required for kitchen, laundry

Pipe Insulation The pipe work must be insulated in accordance with AS/NZS 3500.4All piping with circulating water is to be insulated

Disconnecting union First fitting after the water heater.Note: Vacuum break valves are not normally necessary. Note: Heat traps are only required on Rheem Stainless Steel top outlet water heaters. (Dip tube on other Rheem models acts as an integral heat trap).In Western Australia heat traps are required on all electric storage water heaters.

Water connections - cont’d

Control of Delivery Temperature

AS/NZS 3500.4 stipulates a maximum of up to 50oC hot water temperature to ablution areas (bathrooms). This may be reduced to 45oC depending on the building’s use. This is mandatory for all new installations. The above requirement is mandatory in some states for replacement installation also. Check local regulatory requirements in your area for new and replacement installations.

This is achievable via:

For 50°C applications – tempering valve, thermostatic mixing valve or an AS 3498 compliant 50OC limited water heater model eg: Rheem Gas Continuous Flow model, RheemPlus Heat Pump, RheemPlus Gas or Electric storage

For 45°C applications – thermostatic mixing valve

Page 13: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

13

Water Connections

TPR and ECV Drain Line191025

The relief valve must be fitted with a drain pipe, with the following requirements:

The minimum diameter of the pipe is DN15 on 15 mm valves, and DN20 on 20 mm valves.

The drain pipe must be of copper.

The drain pipe must be of minimum possible length and have a continuous fall to its outlet.

Where the distance from the valve to the final point of discharge is greater than 9 m, the valve drain line must discharge into a tundish that is drained in accordance with AS/NZS 3500.4

Relief Valve drains must terminate in a position that is visible, will not cause nuisance or damage and will not cause injury. Local regulations may require that the discharge from relief valves terminate to a drain.

In frost prone areas additional requirements apply, refer to AS/NZS 3500.4

Page 14: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

14

Pipework and Pipe Sizing

Pipe material

All pipe material used must comply with the requirements of AS/NZS 3500.4.

Plastic/synthetic pipe:

Cannot be used for the last metre into and first metre out of the water heater – these sections must be copper.

Must be rated to the same maximum working pressure and temperature the water heater is capable of supplying.

MUST NOT be used for solar flow and return installations.

Pipe Sizing

Calculating the correct pipe diameter for the installation involves 3 steps:

1. Estimate the peak required flow rate along the length of the pipe.

Note: if the home is fitted with water saving fixtures the required flow rate will be reduced.

2. Calculate the pressure gradient along the pipe.

3. Refer to the pipe supplier’s product handbook to determine the recommended pipe diameter

For most domestic installations, it is acceptable to base pipe sizing for hot water reticulation on known average requirements.

ApplicationFlow Rate (Hot Water)

Litres/min Litres/sec

Domestic Bath 18 0.3Domestic Shower 6 0.1Hand Basin 6 0.1Kitchen Sink and Laundry Tub 7 0.12Washing Machines and Dishwashers 12 0.2

Page 15: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

15

Specific Applications

Rheem water heaters (other than Commercial specific models such as Commpak or Heavy Duty models) are designed for use in a single family domestic dwelling for the purpose of heating potable water. Use in any other application may shorten the life of the water heater.

If an uninterrupted hot water supply is necessary for the application or business, there should be back-up redundancy built into the system design, to ensure supply continuity in the event of the water heater becoming inoperable. We recommend you provide advice to the system owner regarding their needs and building back-up redundancy into the hot water supply system.

Page 16: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.
Page 17: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Scan code for details & installation

instructions

Water connections

Electric S

torag

e

17

Page 18: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

18

Page 19: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

19

Scan code for details & installation

instructions

Rheem Electric 25L 191025,191025/P

Features & Benefits

Small diameter - 400mm

Fast, easy like-for-like replacement

Dual handed connections

Plug & lead indoor models 2.4kW only

7 year cylinder warranty1

MODEL 191025191025/P

Hot Water Delivery (L) 25kW Rating 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP3/4

Approx. Weight (Empty) kg 19

7YEARW

AR R A N

TY

C

YLINDER

436430

60

106

142

400

64O 64O

26O 26O

PEOPLE INSTALLATION

1Indoor/Outdoor

Page 20: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

20

Scan code for details & installation

instructions

Rheem Electric Compact 25 111025,111025/P

Features & Benefits

The smallest Rheem electric water heater

Small diameter - 385mm

Fast, easy like-for-like replacement

Plug & lead indoor models 2.4kW only

7 year cylinder warranty1

MODEL 111025111025/P

Hot Water Delivery (L) 18kW Rating 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 18

7YEARW

AR R A N

TY

C

YLINDER

385

420

65O

26O

390

60

130

116

Indoor/Outdoor

PEOPLE INSTALLATION

1

Page 21: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

21

Scan code for details & installation

instructions

Rheem Electric Compact 47 191045

MODEL 191045Hot Water Delivery (L) 47kW Rating 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 25

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

The most compact available in the over-40L capacity range

Smallest Diameter – 400mm

Just 670mm HIGH (including anode cap)

47L delivery*

Available in 3.6kW rating only

Recessed plug fittings

Dual handed – easier to install

7 year cylinder warranty1

670347

400HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

60142

436

59O

59O

26O 26O

*Rated Hot Water Delivery (L) is 40L in accordance with AS/NZS4692.1. Actual delivery is 47L when tested to AS/NZS4692.1.

PEOPLE INSTALLATION

Indoor/Outdoor1

Page 22: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

22

Scan code for details & installation

instructions

Rheem Electric 50L 191050,191050/P

MODEL 191050191050/P

Hot Water Delivery (L) 50kW Rating 1.8, 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 26

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

Small diameter - 400mm

Designed for restricted space installations

Dual handed connections

Plug & lead models 2.4kW only

Recessed plug fittings

Safe for wall mounting - Wall mounting bracket 299120

7 year cylinder warranty1

60

400

INLET INLET

OUTLET

695397

142

436

59o 59o

26o 26o

Indoor/Outdoor

PEOPLE INSTALLATION

1

Page 23: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

23

Scan code for details & installation

instructions

Rheem Electric 80L 191080

MODEL 191080Hot Water Delivery (L) 80kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:with ECV (kPa) 960without ECV (kPa) 1120Water Connections RP 3/4

Approx. Weight (Empty) kg 36

CABLEENTRY

INLET66

480

INLET

OUTLET OUTLET

RELIEFVALVE

945702

64

515

60o60o

24o 24o

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

Small diameter - 480mm

Fast, easy like-for-like replacement

Designed for restricted space installations

Dual handed connections

Recessed plug fittings

Australian made

7 year cylinder warranty1

Indoor/Outdoor

PEOPLE INSTALLATION

1 - 2

Page 24: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

24

Scan code for details & installation

instructions

Rheem Electric 125L 191125

MODEL 191125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP3/4

Approx. Weight (Empty) kg 49

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

Small diameter - 480mm

Fast, easy like-for-like replacement

Designed for restricted space installations

Dual handed connections

Recessed plug fittings

Australian made

7 year cylinder warranty1

CABLEENTRY

INLET66

480

INLET

OUTLET OUTLET

RELIEFVALVE

1340

1102

64

515

60o60o

24o24o

PEOPLE INSTALLATION

Indoor/Outdoor2 - 3

Page 25: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

25

Scan code for details & installation

instructions

Rheem Electric 160L 191160, 192160

Features & Benefits

Fast, easy like-for-like replacement

Dual handed inlet and outlet fittings

Twin element model - 192160

All models suit connection to concessional (off-peak) tariffs

Mains pressure water delivery

Australian made

7 year cylinder warranty1

MODEL 191160192160

Hot Water Delivery (L) 160kW Rating 1.8, 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 55

1610

1332

104 66

HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

1081

480

515

58o58o

23o

7YEARW

AR R A N

TY

C

YLINDER

PEOPLE INSTALLATION

Indoor/Outdoor2 - 4

Page 26: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

26

Scan code for details & installation

instructions

Rheem Electric 250L 491250,492250

MODEL 491250492250

Hot Water Delivery (L) 250kW Rating 1.8, 3.6, 4.8 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 76

Features & Benefits

Easy retrofit

Dual handed inlet and outlet fittings

Commercial grade enamel

Thicker sacrificial anode

Twin element model - 492250

Australian made

10 year cylinder warranty1

OUTLET OUTLET

1395

9881117

73

CABLEENTRYINLET INLET

103

640

680

92O

88O

32O

RELIEFVALVE

Indoor/Outdoor3 - 5

PEOPLE INSTALLATION

Page 27: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

27

Scan code for details & installation

instructions

Rheem Electric 315L 491315,492315

MODEL 491315492315

Hot Water Delivery (L) 315kW Rating available 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 97

Features & Benefits

Easy retrofit

Dual handed inlet and outlet fittings

Commercial grade enamel

Thicker sacrificial anode

Twin element model - 492315

Australian made

10 year cylinder warranty1

OUTLET OUTLET

1640

1317

113 103

CABLEENTRY INLETINLET

640

680

92O

88O

32O

RELIEFVALVE

1228

Indoor/Outdoor

PEOPLE INSTALLATION

4 - 6

Page 28: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

28

Scan code for details & installation

instructions

Rheem Electric 400L 491400,492400

MODEL 491400492400

Hot Water Delivery (L) 400kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 118

Features & Benefits

Easy retrofit

Dual handed inlet and outlet fittings

Commercial grade enamel

Thicker sacrificial anode

Twin element model - 492400

Australian made

10 year cylinder warranty1

18401479

1323

105121

690

730

97°83°

30°

OUTLET OUTLETRELIEFVALVE

INLETCABLEENTRY

INLET

Indoor/Outdoor

PEOPLE INSTALLATION

5 - 9

Page 29: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

29

Scan code for details & installation

instructions

RheemPlus® Electric 125L 121125

Features & Benefits

Fast, easy like-for-like replacement

50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4

Left hand connection

Australian made

7 year cylinder warranty1

MODEL 121125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections G 3/4BApprox. Weight (Empty) kg 49

7YEARW

AR R A N

TY

C

YLINDER

13401102

64 84

HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

515

183

23o

58o

480545

Indoor/Outdoor

PEOPLE INSTALLATION

2 - 3

Page 30: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

30

Scan code for details & installation

instructions

RheemPlus® Electric 160L 121160

Features & Benefits

Fast, easy like-for-like replacement

50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4

Left hand connection

Australian made

7 year cylinder warranty1

MODEL 121160Hot Water Delivery (L) 160kW Rating 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections G 3/4BApprox. Weight (Empty) kg 57

7YEARW

AR R A N

TY

C

YLINDER

1332

104

1610

HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

84

515

183

23o

58o

480545

Indoor/Outdoor

PEOPLE INSTALLATION

2 - 4

Page 31: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

31

Scan code for details & installation

instructions

RheemPlus® Electric 250L 121250

Features & Benefits

Fast, easy like-for-like replacement

50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4

Left hand connection

Australian made

7 year cylinder warranty1

MODEL 121250Hot Water Delivery (L) 250kW Rating 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections G 3/4BApprox. Weight (Empty) kg 74

7YEARW

AR R A N

TY

C

YLINDER

1117

73 128

1395

705

640

262

680

HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

32o

88o

Indoor/Outdoor3 - 5

PEOPLE INSTALLATION

Page 32: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

32

Scan code for details & installation

instructions

RheemPlus® Electric 315L 121315

Features & Benefits

Fast, easy like-for-like replacement

50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4

Left hand connection

Australian made

7 year cylinder warranty1

MODEL 121315Hot Water Delivery (L) 315kW Rating 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections G 3/4BApprox. Weight (Empty) kg 99

7YEARW

AR R A N

TY

C

YLINDER

1317

113

1640705

640

262

680

HOT WATEROUTLET

COLDWATEROUTLET

T&PRVALVE

128

32o

88o

Indoor/Outdoor

PEOPLE INSTALLATION

4 - 6

Page 33: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

33

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 50L 4A1050

Features & Benefits

Compact design to fit into cupboards and under bench

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

4.8% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

MODEL 4A1050Hot Water Delivery (L) 50kW Rating 1.8, 2.4, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP3/4

Approx. Weight (Empty) kg 17

60o 60o

27.5o 27.5o

HOT WATEROUTLET (LH)

695385

400

432

145

COLDWATERINLET (LH)

TPR VALVE

POWER LEAD & PLUG(APPLICABLEMODELS ONLY)

Indoor/Outdoor

PEOPLE INSTALLATION

1

Page 34: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

34

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 80L 4A1080

MODEL 4A1080Hot Water Delivery (L) 80kW Rating 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP3/4

Approx. Weight (Empty) kg 25

Features & Benefits

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

24% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

495

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

COLDWATERINLET CABLE

ENTRY

885510

185 110

500

125o

55o

25o

Indoor/Outdoor

PEOPLE INSTALLATION

1 - 2

Page 35: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

35

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 125L 4A1125

MODEL 4A1125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 30

Features & Benefits

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

17% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

495

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

COLDWATERINLET CABLE

ENTRY

1295920

185110

500

125o

55o

25o

Indoor/Outdoor

PEOPLE INSTALLATION

2 - 3

Page 36: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

36

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 160L 4A1160

MODEL 4A1160Hot Water Delivery (L) 160kW Rating 2.4, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Approx. Weight (Empty) kg 40

Features & Benefits

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

12% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

495

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

COLDWATERINLET CABLE

ENTRY

16151240

185110

500

125o

55o

25o

Indoor/Outdoor

PEOPLE INSTALLATION

2 - 4

Page 37: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

37

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 250L 4A1250, 4A2250

MODEL 4A12504A2250

Hot Water Delivery (L) 250kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:with ECV (kPa) 680without ECV (kPa) 800Water Connections RP 3/4

Approx. Weight (Empty) kg 45

Features & Benefits

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

Twin element model- 4A2250

19% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

625

COLDWATERINLET

CABLEENTRY 145

630

120o

60o

30o

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

1440

990

230

Indoor/Outdoor3 - 5

PEOPLE INSTALLATION

Indoor/Outdoor3 - 5

PEOPLE INSTALLATION

Page 38: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

38

Scan code for details & installation

instructions

Rheem Electric Stellar® SS 315L 4A1315, 4A2315

MODEL 4A13154A2315

Hot Water Delivery (L) 315kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 55

625

COLDWATERINLET

CABLEENTRY 145

630

120o

60o

30o

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

1760

1310

230

Features & Benefits

Stainless steel cylinder and water fittings resist corrosion for longer, extending product life

Dual handed fittings located on the front of the water heater

Twin element model- 4A2315

17% better performance than MEPS reduces energy use, saving money

Up to 42% lighter2 - for easier handling and installation

Australian made

10 year cylinder warranty1

Indoor/Outdoor

PEOPLE INSTALLATION

4 - 6

Page 39: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

39

Scan code for details & installation

instructions

Rheem Electric Heavy Duty 50L 613050

MODEL 613050Hot Water Delivery (L) 50kW Rating (3 elements) 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP1 1/4Approx. Weight (Empty) kg 34

Features & Benefits

Ideal for cafés, hair salons and small business applications

Larger mass anode

Quick recovery

5 year commercial warranty on cylinder1

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

675405

440

480

30O

90O

90 80

*First hour delivery calculated @ 50oC rise

Indoor/Outdoor

INSTALLATIONFIRST HR DEL

235 -295*

Page 40: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

40

Scan code for details & installation

instructions

Rheem Electric Heavy Duty 315L 613315

MODEL 613315Hot Water Delivery (L) 315kW Rating (3 elements) 3.6, 4.8, 6.0Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP1 1/4Approx. Weight (Empty) kg 100

Features & Benefits

Ideal for cafés, hair salons and small business applications

3 element model

Larger mass anode

Quick recovery

5 year commercial warranty on cylinder1

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

16401294

128 130

Ø640

680

90O

32O

*First hour delivery calculated @ 50oC rise

Indoor/Outdoor

INSTALLATIONFIRST HR DEL

500 -625*

Page 41: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

41

Scan code for details & installation

instructions

Rheem Electric Heavy Duty 315L 616315

MODEL 616315Hot Water Delivery (L) 315kW Rating (6 elements) 3.6, 4.8, 6.0Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP1 1/4Approx. Weight (Empty) kg 104

Features & Benefits

Ideal for cafés, hair salons and industrial applications

6 element model

Larger mass anode

Quick recovery

5 year commercial warranty on cylinder1

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

16401294

128 130

Ø640

680

90O

32O

*First hour delivery calculated @ 50oC rise

Indoor/Outdoor

INSTALLATIONFIRST HR DEL

685 -935*

Page 42: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

42

MODEL 299120

For suitable for Rheem models 191025, 111025, 191045, 4A1050, 191050, 4A1080, 191080

Rheem Wall Mounting Bracket 299120

Features & Benefits

Suitable for 25L, 50L & 80L

To be only used on walls that can support the load of a filled water heater

For fixing to wood use Tek screws for fixing to concrete, brick masonry and natural stone use DynaboltsTM with 8mm masonry drill (nominal embedment 32mm). DynaboltsTM are not suitable for fixing to mortar or soft masonry (not included)

152

117 8

29 95

17 17

152

14089

13 152

130

110

57

8 8

13

9517 17

25

1010o

127

186

5

152

89

13127

Slotted Top Plate

Offset Plate

Bottom Angle Support

Indoor/Outdoor

INSTALLATION

Page 43: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

43

Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.

Page 44: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

44

Page 45: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Scan code for details & installation

instructions

Gas S

torag

e

45

Page 46: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

47

Scan code for details & installation

instructions

Rheem Gas Internal 135L 300135

Features & Benefits

Suitable for indoor installations

Mains pressure – to service multiple hot water demand at once

An easy replacement for most existing 3 Star models

Natural and propane gas model

Australian made

5 year cylinder warranty1

MODEL 300135Storage Capacity (L) 135Hourly Recovery (L) 120Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 54

Ø75 NOM.

TPRVALVE1615

328

1490

988

297

425

58°COLD WATER INLET

HOT WATER OUTLET

500

GAS

Rheem

PEOPLE INSTALLATION

Indoor2 - 4

Page 47: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

48

Scan code for details & installation

instructions

MODEL 300170Storage Capacity (L) 170Hourly Recovery (L) 126Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 63

Rheem Gas Internal 170L 300170

Features & Benefits

Suitable for indoor installations

Mains pressure – to service multiple hot water demand at once

An easy replacement for most existing 3 Star internal models

Natural gas model

5 year cylinder warranty1

Australian made

Ø75 NOM.

TPRVALVE1915

1790

1213

403 297

COLD WATER INLET

HOT WATER OUTLET

GAS

425

500

58°

3 - 5PEOPLE INSTALLATION

Indoor

Page 48: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

49

Scan code for details & installation

instructions

Rheem 4 Star Gas 90L 347090

Features & Benefits

4 Star energy efficiency

Mains pressure at multiple taps

Easy replacement – common fittings with standard 3 Star models

Natural gas model

7 year cylinder warrany1

MODEL 347090Storage Capacity (L) 90Hourly Recovery (L) 100Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 48

7YEARW

AR R A N

TY

C

YLINDER

1158

1078

588916

328

208

473502

298

422

COLD WATER INLET

GAS INLET

RELIEFVALVEHOT

WATER OUTLET

PEOPLE INSTALLATION

1 - 2 Outdoor

Page 49: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

50

Scan code for details & installation

instructions

MODEL 347135Storage Capacity (L) 135Hourly Recovery (L) 113Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 59

Rheem 4 Star Gas 135L 347135

Features & Benefits

4 Star energy efficiency

Mains pressure at multiple taps

Easy replacement – common fittings with standard 3 Star models

Natural and propane gas model

7 year cylinder warrany1

7YEARW

AR R A N

TY

C

YLINDER

COLD WATER INLET GAS

INLET

HOT WATER OUTLET

1558

1478

988

328

208473

502

298

1316

422

RELIEFVALVE

PEOPLE INSTALLATION

2 - 5 Outdoor

Page 50: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

51

Scan code for details & installation

instructions

Rheem 4 Star Gas 170L 347170

Features & Benefits

4 Star energy efficiency

Mains pressure at multiple taps

Easy replacement – common fittings with standard 3 Star models

Natural and propane gas model

7 year cylinder warrany1

7YEARW

AR R A N

TY

C

YLINDER

COLD WATER INLET

GASINLET

RELIEFVALVEHOT

WATER OUTLET

1858

1778

1213

1616

403

208473502

298

422

MODEL 347170Storage Capacity (L) 170Hourly Recovery (L) 113Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 69

PEOPLE INSTALLATION

2 - 5 Outdoor

Page 51: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

52

Scan code for details & installation

instructions

Rheem 5 Star Gas - 265 350265

Features & Benefits

5 Star energy efficiency

Mains pressure at multiple taps

Strong recovery – to have you back in hot water fast

275L first hour capacity of hot water

Compact size – 490mm diameter

Natural gas model

7 year cylinder warranty¹7YEARW

AR R A N

TY

C

YLINDER

COLD WATER INLET

GASINLET

HOT WATER OUTLET

RELIEFVALVE

RELIEFVALVE

1600

988

332

605

556528

240

490

300 95

302

MODEL 350265Storage Capacity (L) 130Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 75

PEOPLE INSTALLATION

2 - 5 Outdoor

Page 52: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

53

Scan code for details & installation

instructions

Rheem 5 Star Gas - 295 350295

Features & Benefits

5 Star energy efficiency

Mains pressure at multiple taps

Strong recovery – to have you back in hot water fast

305L first hour capacity of hot water

Compact size – 490mm diameter

Natural gas model

7 year cylinder warranty¹7YEARW

AR R A N

TY

C

YLINDER

COLD WATER INLET

GASINLET

HOT WATER OUTLET

RELIEFVALVE

1900

1213

407

605

556528

240

490

300 95

302

RELIEFVALVE

MODEL 350295Storage Capacity (L) 160Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 85

3 - 5PEOPLE INSTALLATION

Outdoor

Page 53: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

54

Scan code for details & installation

instructions

RheemPlus® 5 Star Gas - 265 354265

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

5 Star energy efficiency

Mains pressure at multiple taps

50°C temperature limited models supply hot water at a maximum 50°C in accordance with AS 3498

Natural gas model

7 year cylinder warranty¹

COLD WATER INLET

GASINLET

HOT WATER OUTLET

RELIEFVALVE

RELIEFVALVE

1600

988

332 302

605

556 528

545

490

300 95

240182

MODEL 354265Storage Capacity (L) 130Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections G 3/4BGas Connections RP 1/2Approx. Weight (Empty) kg 76

PEOPLE INSTALLATION

2 - 4 Outdoor

Page 54: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

55

Scan code for details & installation

instructions

RheemPlus® 5 Star Gas - 295 354295

7YEARW

AR R A N

TY

C

YLINDER

Features & Benefits

5 Star energy efficiency

Mains pressure at multiple taps

50°C temperature limited models supply hot water at a maximum 50°C in accordance with AS 3498

Natural gas model

7 year cylinder warranty¹

MODEL 354295Storage Capacity (L) 160Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections G 3/4BGas Connections RP 1/2Approx. Weight (Empty) kg 86

COLD WATER INLET

GASINLET

HOT WATER OUTLET

RELIEFVALVE

RELIEFVALVE

19001213

407 302

605

556 528

545

490

300 95

240182

3 - 5PEOPLE INSTALLATION

Outdoor

Page 55: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

56

Scan code for details & installation

instructions

Rheem Stellar® Gas - 330 850330

Features & Benefits

5 Star energy efficiency – uses less gas than 3 or 4 Star water heaters

200L/hour hot water recovery

Advanced technology – the Stellar Superflue®

Mains pressure – to service multiple hot water demands at once

Natural gas model

10 year cylinder warranty1

Australian made

MODEL 850330Storage Capacity (L) 130Hourly Recovery (L) 200 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 70

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

GASINLET

485

558

29993

988

252

328

520

298210

1600 252 252

PEOPLE INSTALLATION

2 - 5 Outdoor

Page 56: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

57

Scan code for details & installation

instructions

Rheem Stellar® Gas - 360 850360

Features & Benefits

5 Star energy efficiency – uses less gas than 3 or 4 Star water heaters

200L/hour hot water recovery

Advanced technology – the Stellar Superflue®

Mains pressure – to service multiple hot water demands at once

Natural gas model

10 year cylinder warranty1

Australian made

MODEL 850360Storage Capacity (L) 160Hourly Recovery (L) 200 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:

with ECV (kPa) 960without ECV (kPa) 1120

Water Connections RP 3/4

Gas Connections RP 1/2Approx. Weight (Empty) kg 80

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

GASINLET

485

558

29993

1213

252

409

520

298210

1900252 252

PEOPLE INSTALLATION

3 - 6 Outdoor

Page 57: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

58

Scan code for details & installation

instructions

Rheem Heavy Duty Gas 260L 630260

Features & Benefits

Supply large quantities of hot water

Double layer of vitreous enamel

Adjustable thermostat

Equa-Flow® system allows for flexibility in installation

Natural gas & Propane model

5 year commercial warranty on cylinder1

MODEL 630260Storage Capacity (L) 260Thermal Input (MJ/hr) 51 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 1/2Approx. Weight (Empty) kg 106

*First hour delivery calculated @ 50oC rise

Outdoor

INSTALLATIONFIRST HR DEL

385L*

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

GAS

15201640

990

330300

680655

420

590

295

27O

Page 58: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

59

Scan code for details & installation

instructions

MODEL 620260Storage Capacity (L) 260Thermal Input (MJ/hr) 51 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 1/2Approx. Weight (Empty) kg 98

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

GAS

1520

1320

1660

100

330 300

590

67027O

*First hour delivery calculated @ 50oC rise

Indoor

INSTALLATIONFIRST HR DEL

385L*Rheem Heavy Duty Gas 260L 620260

Features & Benefits

Supply large quantities of hot water

Double layer of vitreous enamel

Adjustable thermostat

Equa-Flow® system allows for flexibility in installation

Natural gas & Propane model

5 year commercial warranty on cylinder1

Page 59: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

60

Scan code for details & installation

instructions

*First hour delivery calculated @ 50oC rise

Rheem Heavy Duty Gas 265L 631265

Features & Benefits

Multi-Fin™ technology means faster, more efficient heating

Electronic ignition for economy

Equa-Flow® system allows for flexibility in installation

Digital adjustable thermostat to 82°C for sanitisation applications

BMS option available

Natural gas, Propane & Butane model

5 year commercial warranty on cylinder1

MODEL 631265Storage Capacity (L) 265Thermal Input (MJ/hr) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 3/4

Approx. Weight (Empty) kg 146

Outdoor

INSTALLATIONFIRST HR DEL

620L*

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

GAS

16551835

750

700

380

710660

420

610

302

36O

Page 60: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

61

Scan code for details & installation

instructions

*First hour delivery calculated @ 50oC rise

Features & Benefits

Multi-Fin™ technology means faster, more efficient heating

Electronic ignition for economy

Equa-Flow® system allows for flexibility in installation

Digital adjustable thermostat to 82°C for sanitisation applications

BMS option available

Natural gas, Propane & Butane model

5 year commercial warranty on cylinder1

MODEL 621265Storage Capacity (L) 265Thermal Input (MJ/hr) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 3/4

Approx. Weight (Empty) kg 137

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

GAS

1655

1795

125

750

700

380

610

750660

302

36O

Indoor

INSTALLATIONFIRST HR DEL

620L*Rheem Heavy Duty Gas 265L 621265

Page 61: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

62

Scan code for details & installation

instructions

*First hour delivery calculated @ 50oC rise

Rheem Heavy Duty Gas 275L 631275 INSTALLATIONFIRST HR DEL

970L*

Features & Benefits

Multi-Fin™ technology means faster, more efficient heating

Electronic ignition for economy

Digital adjustable thermostat to 82°C for sanitisation applications

Outdoor installation or Indoor room sealed with kit (purchased separately)

BMS option available

Natural gas, Propane & Butane model

5 year commercial warranty on cylinder1

MODEL 631275Storage Capacity (L) 265Thermal Input (MJ) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:with ECV (kPa) 680without ECV (kPa) 800Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 3/4

Approx. Weight (Empty) kg 132

MODEL 631275Storage Capacity (L) 275Thermal Input (MJ/hr) 200 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 3/4

Approx. Weight (Empty) kg 187

HOTWATEROUTLET

TRPVALVE

COLDWATERINLET

GAS

16951865

760

700

340

780722

320

640

320

36O

Indoor/Outdoor

Page 62: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

63

Scan code for details & installation

instructions

*First hour delivery calculated @ 50oC rise

Indoor

INSTALLATIONFIRST HR DEL

Rheem Heavy Duty Gas 275L 621275

Features & Benefits

Multi-Fin™ technology means faster, more efficient heating

Electronic ignition for economy

Equa-Flow® system allows for flexibility in installation

Digital adjustable thermostat to 82°C for sanitisation applications

BMS option available

Natural gas, Propane & Butane model

5 year commercial warranty on cylinder1

MODEL 621275Storage Capacity (L) 275Thermal Input (MJ/hr) 200 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections (BSPF) RP 11/4

Gas Connections (BSPF) RP 3/4

Approx. Weight (Empty) kg 172

HOTWATEROUTLET

TPRVALVE

COLDWATERINLET

GAS

1695

1895

200

760

700

340

640

780722

320

36O

970L*

Page 63: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

64

Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.

Page 64: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Scan code for details & installation

instructions

Gas C

ontinuo

us Flo

w

65

Page 65: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

66

Page 66: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

67

Scan code for details & installation

instructions

Rheem 12L 876612, 874612

Features & Benefits

12 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options

Accessories: Pipe cover 299841, Recess Box 299842, 299842/WA Security Cage 299867

50°C models available, requiring no tempering valve3

LED display for easy fault diagnosis

Natural gas & Propane models

10 year heat exchanger warranty1

MODEL 876612 874612

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 94Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 16

ENERGY EFFICIENTSTAR

CL

592

5753

163

1610

90

350

490

54

520

592

4543

12543

126

51

GASCONNECTION

COLD WATER INLET

HOT WATEROUTLET

COLD WATER INLET

GAS CONNECTION

HOT WATER OUTLET

560

164

POWER LEAD CONNECTION

MOUNTINGHOLES

PEOPLE INSTALLATION

Outdoor1 - 2

Page 67: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

68

Rheem Standard Flue Diverter 299881 - suitable for 12L/16L

Features & Benefits

Enables compliance with relevant national and local regulations for installation in covered open areas.*

Suitable for Rheem 12L or Rheem Metro 16L

Offers added flexibility in installation

Fits simply to the water heater

Natural gas model

Suitable for installation with Recess Box 299842, 299842/WA Pipe Cover 299841

Fe

PART 299881To suit models:876612NF, 874612NF876E16NF, 874E16NF

379

520

350

245

262

160

*Confirm with your local authorities that the installationcomplies with all regulations applicable in your area.

INSTALLATION

Outdoor

Page 68: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

69

Scan code for details & installation

instructions

Rheem Metro 16L 876E16, 874E16

Features & Benefits

16 L/min continuous hot water delivery @ 25oC rise

60ºC hot water for kitchen and laundry

50ºC models provide added safety

Remote Temperature Controller options for added convenience and safety

LED display for easy fault diagnosis

Natural gas & Propane models

10 year heat exchanger warranty¹

MODEL 876E16 874E16

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 126Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 16

CL

592

5753

163

1610

90

350

490

54

520

592

4543

12543

126

51

GASCONNECTION

COLD WATER INLET

HOT WATEROUTLET

COLD WATER INLET

GAS CONNECTION

HOT WATER OUTLET

560

164

POWER LEAD CONNECTION

MOUNTINGHOLES

ENERGY EFFICIENTSTAR

PEOPLE INSTALLATION

Outdoor1 - 3

Page 69: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

70

Scan code for details & installation

instructions

Rheem 20L 876620, 874620

Features & Benefits

20 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options

50°C models available, requiring no tempering valve3

LED display for easy fault diagnosis

Natural gas & Propane models

Accessories: Pipe Cover 299841, Recess Box 299842, 299842/WA Security Cage 299867

10 year heat exchanger warranty1

MODEL 876620 874620

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 153Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 16

CL

592

5753

163

1610

90

350

490

54

520

592

4543

12543

126

51

GASCONNECTION

COLD WATER INLET

HOT WATEROUTLET

COLD WATER INLET

GAS CONNECTION

HOT WATER OUTLET

560

164

POWER LEAD CONNECTION

MOUNTINGHOLES

ENERGY EFFICIENTSTAR

PEOPLE INSTALLATION

2 - 4 Outdoor

Page 70: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

71

Scan code for details & installation

instructions

Rheem Metro Plus 24L 875E24, 871E24

Features & Benefits

24 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options

50°C models available, requiring no tempering valve3

Digital display for easy fault diagnosis

Natural gas & Propane models

Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867

10 year heat exchanger warranty1

MODEL 875E24 871E24

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 19

ENERGY EFFICIENTSTAR

17HOT WATER

OUTLETGAS INLET

GASCONNECTIONCOLDWATER INLET

COLDWATER INLET

HOT WATEROUTLETPOWER

CONNECTION

350

90 19

44

562565605

112127

21132

53 103

16

205

50

10

65

647

92

MOUNTING HOLES

CL

PEOPLE INSTALLATION

Outdoor4 - 5

Page 71: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

72

Scan code for details & installation

instructions

Rheem 24L 875624, 871624

Features & Benefits

24 L/min continuous hot water delivery @ 25oC rise

Flamesafe® overheat protection

Remote temperature controller options

50°C models available, requiring no tempering valve3

Digital display for easy fault diagnosis

Natural gas & Propane models

10 year heat exchanger warranty1

MODEL 875624 871624

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 21

ENERGY EFFICIENTSTAR

17HOT WATER

OUTLETGAS INLET

GASCONNECTIONCOLDWATER INLET

COLDWATER INLET

HOT WATEROUTLETPOWER

CONNECTION

350

90 19

44

562565605

112127

21132

53 103

16

205

50

10

65

647

92

MOUNTING HOLES

CL

PEOPLE INSTALLATION

4 - 5 Outdoor

Page 72: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

73

Scan code for details & installation

instructions

33

379

350

137119

305205

*Confirm with your local authorities that the installation complies with all regulations applicable in your area.

PEOPLE INSTALLATION

MODEL 875E24NF-FDMin. Operating Flow rate (L/min) 2.7Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 19

Features & Benefits

Enables compliance with relevant national and local regulations for installation in covered open areas.*

Adjustable to deliver 50OC at the nearest tap

Recess Box available -299842 to set water heater into the wall. Compatible with flue diverter.

Digital display for easy fault diagnosis and service

Natural gas model

10 year heat exchanger warranty¹

OutdoorRheem Metro Plus 24L Standard Flue Diverter 875E24NF-FD

4 - 5

Page 73: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

74

Scan code for details & installation

instructions

Rheem Metro Plus 24L Extended Flue Diverter 875E24NF-FE

MODEL 875E24NF-FE

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connections R 3/4

Approx. Weight (Empty) kg 19

Features & Benefits

Enables compliance with relevant national and local regulations for installation in covered open areas.*

Digital display for easy fault diagnosis

Natural gas model

10 year heat exchanger warranty¹

Edge ofbalcony

565

350 Edge ofbalcony

137119

30566

591

no greater than 695

938

350

205

*Confirm with your local authorities that the installation complies with all regulations applicable in your area.

PEOPLE INSTALLATION

Outdoor4 - 5

Page 74: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

75

Scan code for details & installation

instructions

Rheem Metro Max 26L 875E26, 871E26

Features & Benefits

26 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options

50°C models available, requiring no tempering valve3

Digital display for easy fault diagnosis

Natural gas & Propane models

Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867

10 year heat exchanger warranty1

MODEL 875E26 871E26

Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 199Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 21

ENERGY EFFICIENTSTAR

17HOT WATER

OUTLETGAS INLET

GASCONNECTIONCOLDWATER INLET

COLDWATER INLET

HOT WATEROUTLETPOWER

CONNECTION

350

90 19

44

562565605

112127

21132

53 103

16

205

50

10

65

647

92

MOUNTING HOLES

CL

PEOPLE INSTALLATION

Outdoor4 - 5

Page 75: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

76

Scan code for details & installation

instructions

Rheem 27L 876627, 874627

Features & Benefits

27 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options for added convenience and safety

50°C models available, requiring no tempering valve3

Digital display for easy fault diagnosis

Natural gas & Propane models

10 year heat exchanger warranty1

MODEL 876627 874627

Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connection R 3/4

Approx. Weight (Empty) kg 24

HOT WATEROUTLET

GASCONNECTION

COLD WATER INLET

POWER LEAD CONNECTION

35126990 17

42

669

132 127 226

54

669

227

9764

28

84

CL

601

ENERGY EFFICIENTSTAR

PEOPLE INSTALLATION

Outdoor4 - 6

Page 76: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

77

Scan code for details & installation

instructions

Rheem 27L Internal 866627, 864627

Features & Benefits

27 L/min continuous hot water delivery @ 25oC rise

Remote Temperature Controller options for added convenience and safety

Rheem co-axial flue system

50°C models available, requiring no tempering valve3

Digital display for easy fault diagnosis

Natural gas model

10 year heat exchanger warranty1

MODEL 866627 864627

Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4

Gas Connections R 3/4

Approx. Weight (Empty) kg 24

ENERGY EFFICIENTSTAR

351 240

21

5338

10 to 40

131

17

763

132 1275

240119

8628

107

707650

49

331Ø127

HOT WATER OUTLET

HOT WATEROUTLET

COLD WATERINLET

POWER LEAD CONNECTION

POWER LEADCONNECTION

GASCONNECTION

GASCONNECTION

COLD WATER INLET

CL

PEOPLE INSTALLATION

Indoor4 - 6

Page 77: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

78

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627

Approx

255

Approx

192

Approx

207

Approx

270 Approx

500Approx

380

Approx 400295118 90° Bend

210

260

280

400

Approx

153

295119 45° Bend

295116 Horizontal Terminal

Ø127 Ø76

97

227

295117 Vertical Terminal

300 260140

Ø233

Ø208

PART DESCRIPTION WHERE USED

295116 Horizontal Terminal Required where flue terminates horizontally

295117 Vertical Terminal Required where flue terminates vertically

295118 90º Bend Maximum of 3 per installation

295119 45º Bend Maximum of 6 per installation (with no 90º bends)

Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.

Page 78: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

79

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627

295126 Straight Length 300mm

277

295124 MM Adapter

187

295123 FF Adapter

213

295125 Trim Ring

Ø230

Ø133

887

295122 – Straight Length 900mm

PART DESCRIPTION WHERE USED

295122 Straight Length 900mm Long straight sections

295123 Female Female Adapter

Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues

295124 Male Male Adapter

Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues

295125 Trim Ring (optional) Conceal internal and/or external hole in wall or ceiling terminating flues

295126 Straight Length 300mm Short straight sections

Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.

Page 79: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

80

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627

295139 Condensate Trap

295129 – Bracket

145 180

Ø127 25

295127 – Adjustable Straight 560 – 890mm

890 MAX 560 MIN

PART DESCRIPTION WHERE USED

295127 Adjustable Length 560 – 890mm Allows to trim flue to exact length required

295129 Bracket Support flue at intervals not exceeding 2m and after any bend

295139 Condensate Trap Required with every condensate drain. Can be connected to a common waste

Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.

Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.

Page 80: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

81

Rheem Continuous Flow Flue System Typical Internal Flue Installation

295116295126295118

295125(optional)

295117

295122

295126

295139

FLASHING (not supplied)

13.5m MAXIMUM*

VERTICAL TERMINAL

Horizontal termination to adjacent wall

Direct Vent Horizontal Wall Direct Vent Vertical Termination

* Note: Maximum flue length with no bends is 13.5m. Reduce the maximum length by 1.5m for every 90° bend and reduce the maximum length by 0.75m for every 45° bend.

Flue termination must comply with the requirements of AS/NZS 5601.1

Refer to Rheem Owner’s Guide and Installation Instruction for details.

13.5m MAXIMUM LINEAL LENGTH* SUBTRACT 1.5M PER 90˚ BEND OR 0.75m PER 45˚ BEND

295124 295127 295122 295123 295116

295125295118

295126/ 295122/ 295127

20mm

1000mm

SLOPE

Page 81: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

82

Controllers Rheem Standard and Deluxe Electronic Temperature Controllers

Features & Benefits

Suitable for all Rheem Continuous Flow models

Allows you to choose the desirable hot water temperature

Standard or Deluxe models

Deluxe controllers offer a “bath fill’ mode to turn off the water flow once the bath is filled

Deluxe Temperature Controller with cable

299858 - Kitchen

299859 - Bathroom 1

299860 - Bathroom 2

Controllers and cable also available separately

Temperature Controller with cable

299850 - Kitchen

299851 - Bathroom 1

299852 - Bathroom 2

Page 82: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

83

Scan code for details & installation

instructions

Rheem EZ Link® 290141

Features & Benefits

Suitable for use with all Rheem 12,16, 20 and 27 L/min Continuous Flow gas water heater models

Flexible delivery of up to 54 L/min

Staged heating, so energy usage corresponds only to the hot water demand

2 units means no loss of hot water supply in the event of a unit breakdown

Optional remote controller for temperature control, easy fault diagnosis and service

MODEL 290141Suitable for Rheem 12,16, 20 and 27 L/min models

Refer to EZ Link Owner’s Guide and Installation Instructions for the set up procedure.

Page 83: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

84

Rheem Security Cage 299867

Rheem Security Cage for use with all Rheem continuous flow gas water heater models.

The kit contains:

1. Security cage

2. Top mounting bracket

3. Bottom mounting bracket

4. Securing fasteners

1

4

2

3

1030

261

600

508

565

Page 84: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

85

Rheem Security Wall Bracket 299868

Suitable for most Rheem Continuous Flow units

Flat Security Bracket – to be fixed to the masonry wall with supplied anchors and shear-off nuts.

U Shaped Security Bracket –to be fastened to flat bracket using a padlock (padlock not supplied)

A

B

190

233

117

42

30

86

168

33

42

PART 299868Suitable for models: 875E24, 871E24, 875624, 871624, 875E26, 871E26, 876627, 874627

B

A

Hole sizeØ7mm

Page 85: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

86

Rheem Recess Box 299842 (12-26L), 299831 (27L)

PART NO. FASCIA CAVITY

Height Width Depth Height Width DepthA B C D E F

299842 (12-26L) 1088 425 25 1010 347 160299831 (27L) 1081 435 50 1010 352 160299842/WA (12-26L) 1088 425 59 1015 347 125299831/WA (27L) 1091 435 85 1018 353 125

Security BracketRequires Padlock(not Supplied)

TH

0

0

The installation position of the Rheem Continuous Flow unit must comply with AS 5601 or AS/NZS 5601.1. This should be considered when choosing the installation position of the Recess box.

Features & Benefits

Galvanised Steel

Especially designed for standard double brick construction, WA models suit solid brick construction

In-built anti-theft bracket

Easy access door

Scan code for details & installation

instructions

Page 86: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

87

Scan code for details & installation

instructions

Rheem Pipe Cover Kit 299841, 299848, 299830

The Pipe Cover is to be installed after the Continuous Flow water heater has been installed. The pipe cover is designed to be installed underneath the water heater to cover the pipe work and valves, but cannot cover the external GPO.

The kit contains:

1. Pipe cover housing

2. Pipe cover access panel

1

2

MODEL299841 suitable for 12-20L/min299848 suitable for 24L/min and 26L/min299830 suitable for 27L/min

Indoor/Outdoor3 - 5

PEOPLE INSTALLATION

Page 87: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

88

Scan code for details & installation

instructions

Rheem Pronto® 834012

Features & Benefits

Easy installation matching common mechanical water heater fittings

6 Star energy efficiency

12 L/min continuous hot water delivery @ 25oC rise

Electronic temperature control

Overheat protection

No electrical connection required

Available in natural and propane

Optional heat shield available - 299880

10 year heat exchanger warranty1

MODEL 834012Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 99 NaturalNom. Gas Consumption (MJ/hr) 96 PropaneMax Water Supply Pressure (kPa) 800Min Water Supply Pressure (kPa) 120Water Connections R1/2

Gas Connection Rp 3/4

Approx. Weight (Empty) kg 21

ENERGY EFFICIENTSTAR

3 - 4 Outdoor1 - 2

840

45

HOTWATEROUTLET

HOT WATEROUTLET

COLD WATERINLET

COLDWATERINLET

GAS INLET(FLUSH TO

BASE)

GAS INLET

45388

120 120

222

465

70

69 55 69

70

285

268

R3.5

R8

120 120

CL

Indoor/Outdoor

PEOPLE INSTALLATION

1 - 2 Outdoor

Page 88: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

89

Scan code for details & installation

instructions

Rheem Pronto® 834016

Features & Benefits

Easy installation matching common mechanical water heater fittings

5.9 Star (NG) 5.8 Star (Propane)

16 L/min continuous hot water delivery @ 25oC rise

Electronic temperature control

Overheat protection

No electrical connection required

Available in natural and propane

Optional heat shield available - 299880

10 year heat exchanger warranty1

MODEL 834016Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 128 NaturalNom. Gas Consumption (MJ/hr) 125 PropaneMax Water Supply Pressure (kPa) 800Min Water Supply Pressure (kPa) 140Water Connections R1/2

Gas Connection Rp 3/4

Approx. Weight (Empty) kg 25

1 - 3 Outdoor

875

50

HOTWATEROUTLET

HOT WATEROUTLET

COLD WATERINLET

COLDWATERINLET

GAS INLET(FLUSH TO

BASE)

GAS INLET

50443

120 120

222

451

84

69 48 69

84

285

268

R3.5

R8

120 120

CL

ENERGY EFFICIENTSTAR

5.9

PEOPLE INSTALLATION

1 - 3 Outdoor

Page 89: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.3 60ºC and higher temperature models and some applications require a

tempering valve in accordance with AS 3500.4.

Page 90: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Scan code for details & installation

instructions

So

lar

91

Page 91: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

92

Page 92: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

93

Scan code for details & installation

instructions

Rheem Loline 160L 511161

MODEL 511161Storage Capacity (L) 165Solar Collectors (VIC or SA) 1 CSA2612Solar Collectors (VIC only) 2 LCSBooster Type GasWeight Empty (kg)- Tank without booster 52Weight Empty (kg)- Tank with booster 73Tank Water Connections RP 3/4

Gas Booster Water Connections R 3/4

Gas Connection R 3/4

Features & Benefits

Split system design – vitreous enamel lined cylinder installed at ground level

Limited frost protection4

24 L/min in-series gas booster site integrated or Rheem 27L/min in-series gas booster installed remotely

Suitable with CSA2612 collector (VIC & SA) or 2 LCS collectors (VIC only)

Eligible for STCs5

5 year cylinder warranty1

110°

23°

695514

480

65° 47°

1615

987937

105

395

52961

SOLARPREHEATOUTLET

SOLAR HOT(FROMCOLLECTOR)INLET

COLD WATERINLET

SOLAR COLD(TO COLLECTOR) OUTLET

PEOPLE INSTALLATION

Outdoor1 - 4

Page 93: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

94

Scan code for details & installation

instructions

Rheem Loline 270L 511271

MODEL 511271Storage Capacity (L) 270Solar Collectors 2 or 3 NPT200,

2 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 71Water Connections RP 3/4

Features & Benefits

Split system design – vitreous enamel lined cylinder installed at ground level

Limited frost protection4

Booster – choice of electric element or 6-Star continuous flow gas

Gas booster tank mounting kit available

2 or 3 NPT200 or 2 LCS collectors

Eligible for STCs5

5 year cylinder warranty1

640

1395

73

588

73

412

1112

680

32o

88o

32o

COLD WATERINLET

HOT WATEROUTLET

ELECTRICALCABLE ENTRYSOLAR HOT INLET

(FROM COLLECTOR)

SOLAR COLDOUTLET(FROMCOLLECTOR)

TPRVALVE

PEOPLE INSTALLATION

2 - 5Indoor/Outdoor

Page 94: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

95

Scan code for details & installation

instructions

Rheem Loline 325L 511325

MODEL 511325Storage Capacity (L) 325Solar Collectors 2 or 3 NPT200,

2 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 87Water Connections RP 3/4

Features & Benefits

Split system design – vitreous enamel lined cylinder installed at ground level

Limited frost protection4

Booster – choice of electric element or 6-Star continuous flow gas

Gas booster tank mounting kit available

2 or 3 NPT200 or 2 LCS collectors

Eligible for STCs5

5 year cylinder warranty1

640

1640

73

710

73

481

1357

680

32o

88o

32o

COLD WATERINLET

HOT WATEROUTLET

ELECTRICALCABLE ENTRY

T&PRVALVE

SOLAR HOTINLET

(FROMCOLLECTOR)

SOLAR COLDOUTLET(FROMCOLLECTOR)

PEOPLE INSTALLATION

2 - 6Indoor/Outdoor

Page 95: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

96

Scan code for details & installation

instructions

Rheem Loline 410L 511410

MODEL 511410Storage Capacity (L) 410Solar Collectors 2, 3 or 4 NPT200,

2 or 3 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 111Water Connections RP 3/4

Features & Benefits

Split System design – vitreous enamel lined cylinder installed at ground level

Limited frost protection4

Booster – choice of electric element or 6-Star continuous flow gas

2, 3 or 4 NPT200 or 2 or 3 LCS collectors

Eligible for STCs5

5 year cylinder warranty1

690

1840

81

795

81

532

1519

730

30o

82o

30o

COLD WATERINLET

HOT WATEROUTLET

ELECTRICALCABLE ENTRYSOLAR HOT INLET

(FROM COLLECTOR)

SOLAR COLDOUTLET(FROMCOLLECTOR)

T&PRVALVE

PEOPLE INSTALLATION

3 - 7Indoor/Outdoor

Page 96: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

97

Scan code for details & installation

instructions

Rheem Premier® Loline 160L 590160

Features & Benefits

Complete Frost Protection – Unique Drain-Back™ heat exchange technology

Complies with regulations in all states

Booster – 6-star continuous flow gas

Compact spilt system design

1 T200, 2 NPT200 or 2 LCS collectors

Eligible for STCs5

5 year cylinder warranty1

MODEL 590160Storage Capacity (L) 160Solar Collectors 1 T200, 2 LCS

or 2 NPT200Booster Type GasWeight Empty - (kg) Tank 93Tank Water Connections RP 3/4

Gas Booster Water Connections R 3/4

Gas Connections R 3/4

423212

211

503

51

1213

402

1615

1818

1613 18

58

SOLARPREHEATOUTLET

COLDWATERINLET

TPRVALVE

SOLARCONNECTIONS

PEOPLE INSTALLATION

2 - 5 Outdoor

Page 97: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

98

Scan code for details & installation

instructions

Rheem Premier® Loline 160L 596160

Features & Benefits

Complete Frost Protection – Unique Drain-Back™ heat exchange technology

Complies with regulations in all states

Booster – 6-star 20 L/min continuous flow gas (factory fitted)

Compact spilt system design

1 T200, 2 NPT200 or 2 LCS collectors

Eligible for STCs5

5 year cylinder warranty1

MODEL 596160Storage Capacity (L) 160Solar Collectors 1 T200, 2 LCS

or 2 NPT200Booster Type GasWeight Empty (kg) - Tank 112Water Connections RP 3/4

Gas Booster Water Connections R 3/4

Gas Connections R 3/4

423212

211

503

690

51

408

805

402

1206

1818

1613 18

58

SOLARPREHEATOUTLET

HOTWATEROUTLET

COLDWATERINLET

TPRVALVE

SOLARCONNECTIONS

PEOPLE INSTALLATION

Outdoor2 - 5

Page 98: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

99

Scan code for details & installation

instructions

Rheem Premier® Loline 270L 596270

Features & Benefits

Complete Frost Protection – Unique Drain-Back™ heat exchange technology

Complies with regulations in all states

Booster – 27 L/min 6-star continuous flow gas (site integrated)

Full mains pressure for multiple outlets

Integrated tempering valve

2 or 3 SPA2000 or T200 collectors

Eligible for STCs5

5 year cylinder warranty1

MODEL 596270Storage Capacity (L) 270Solar Collectors 2 or 3 SPA2000

2 or 3 T200Booster Type GasWeight Empty - (kg) Tank without booster 141Weight Empty - (kg) Tank with booster 165Water Connections RP 3/4

Gas Connections R 3/4

16541455

1701

1787

510772

265

351

890

648182

215 324

48o

FLUETERMINAL

PEOPLE INSTALLATION

Outdoor2 - 5

Page 99: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

100

Scan code for details & installation

instructions

Rheem Premier® Loline 270L 591270

Features & Benefits

Complete Frost Protection – Unique Drain-Back™ heat exchange technology

Complies with regulations in all states

Booster – electric element

Full Mains Pressure for multiple outlets

2 or 3 SPA2000 or T200 collectors

Eligible for STCs5

5 year cylinder warranty1

MODEL 591270Storage Capacity (L) 270Solar Collectors 2 or 3 SPA2000

2 or 3 T200Booster Type ElectricElement size (kW) 3.6Weight Empty (kg) - Tank 146Weight Empty - (kg) Solar Collector (each)

48

Water Connections RP 3/4

980

1775

1701

1078

377

385344324

648

68247o

73o

ELECTRICALCABLE ENTRY

HOT WATEROUTLET

TPRVALVE

COLD WATERINLET

PEOPLE INSTALLATION

2 - 5Indoor/Outdoor

Page 100: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

101

Scan code for details & installation

instructions

Rheem 52L Series 52L180

MODEL 52L180Storage Capacity (L) 180Solar Collectors 1 NPT200, L,

CSA2007Booster Type Electric or GasWeight Empty (kg) - Tank 48Weight Empty - (kg) Solar Collector (each)

33

Water Connections DN15 Compression

Gas Connections DN15 Compression

Features & Benefits

Suitable for temperate or tropical location

Stainless steel cylinder

The 52L Series system directly heats the water as it passes through the collectors

Booster – choice of electric element or 6-Star continuous flow gas

Eligible for STCs5

7 year cylinder warranty1 with NPT200 collector

10 year cylinder warranty1 with L, CSA2007 collector*

7YEARW

AR R A N

TY

C

YLINDER

HOT WATEROUTLET

COLDWATERINLET

TPRVALVE

ELECTRICALCONNECTION 79

1937

563

249011381022

1495

* Available through Rheem Solar Specialists only

PEOPLE INSTALLATION

Outdoor1 - 2

Page 101: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

102

Scan code for details & installation

instructions

Rheem 52L Series 52L300

Features & Benefits

Suitable for temperate or tropical location

Stainless steel cylinder

The 52L Series system directly heats the water as it passes through the collectors

Booster – choice of electric element or 6-Star continuous flow gas

Available in four COLORBOND® Steel colours

Eligible for STCs5

7 year cylinder warranty1

10 year cylinder warranty1 with L, CSA2007 collector*

7YEARW

AR R A N

TY

C

YLINDER

MODEL 52L300Storage Capacity (L) 300Solar Collectors 2 NPT200,

L, CSA2007Booster Type Electric or GasWeight Empty (kg) - Tank 72Water Connections DN15 Compression

HOT WATEROUTLETTPRVALVE

ELECTRICALCONNECTION

563 2180

21982094

2490

1937

79

COLDWATERINLET

* Available through Rheem Solar Specialists only

PEOPLE INSTALLATION

Outdoor2 - 5

Page 102: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

103

Scan code for details & installation

instructions

Rheem Hiline 52S 52S160

MODEL 52S160 Storage Capacity (L) 160Solar Collectors 1 NPT200Booster Type Electric or GasWeight Empty (kg) - Tank 70Hot Water Connection RP 3/4

Cold Water Connection G 1/2 B

Features & Benefits

Energy efficient

Booster – choice of electric element or 6-Star continuous flow gas

Vitreous enamel lined cylinder

Eligible for STCs5

5 year cylinder warranty1

HOT WATEROUTLET

TPRVALVE

ELECTRICALCONNECTION

79

1937

540

249011381022

1070

COLDWATERINLET

PEOPLE INSTALLATION

Outdoor1 - 2

Page 103: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

104

Scan code for details & installation

instructions

Rheem Hiline 52S 52S300

MODEL 52S300 Storage Capacity (L) 300Solar Collectors 2 NPT200Booster Type Electric or gasWeight Empty (kg) - Tank 100Hot Water Connection RP 3/4

Cold Water Connection G 1/2 B

Features & Benefits

Energy efficient

Booster – choice of electric element or 6-Star continuous flow gas

Vitreous enamel lined cylinder

Eligible for STCs5

5 year cylinder warranty1

79

540

19372490

2094

21981022

1865

HOT WATEROUTLET

TPRVALVE

ELECTRICALCONNECTION

COLDWATERINLET

3 - 5INSTALLATIONPEOPLE

Outdoor2 - 5

Page 104: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

105

Scan code for details & installation

instructions

Features & Benefits

Complete frost protection

Space saving design – a complete roof mounted installation

Stainless steel cylinder

Booster – choice of electric element or 6-Star continuous flow gas

Eligible for STCs5

7 year cylinder warranty1 with SPA2000, NPT200

10 year cylinder warranty1 with L, CSA2007 collector*

MODEL 52H180Storage Capacity (L) 180Solar Collectors 1 SPA2000,

NPT200, LBooster Type Electric or GasWeight Empty (kg) - Tank 52Hot Water Connection DN15 Compression

Cold Water Connection DN15 Compression

Rheem Premier® Hiline 52H 52H180

HOT WATEROUTLET

COLDWATERINLET

TPRVALVE

ELECTRICALCONNECTION 79

1937

563

249011381022

1495

7YEARW

AR R A N

TY

C

YLINDER

* Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only

INSTALLATIONPEOPLE

1 - 2 Outdoor

Page 105: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

106

Scan code for details & installation

instructions

Rheem Premier® Hiline 52H 52H300

Features & Benefits

Complete frost protection

Space saving design – a complete roof mounted installation

Stainless steel cylinder

Booster – choice of electric element or 6-Star continuous flow gas

Eligible for STCs5

7 year cylinder warranty1 with SPA2000, NPT200

10 year cylinder warranty1 with L, CSA2007 collector*

HOT WATEROUTLETTPRVALVE

ELECTRICALCONNECTION

563 2180

21982094

2490

1937

79

COLDWATERINLET

MODEL 52H300Storage Capacity (L) 300Solar Collectors 1 SPA2000,

NPT200, LBooster Type Electric or GasWeight Empty - (kg) Tank 79Hot Water Connection R 3/4

Cold Water Connection RP 1/2

7YEARW

AR R A N

TY

C

YLINDER

* Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only

PEOPLE INSTALLATION

Outdoor2 - 5

Page 106: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

107

Scan code for details & installation

instructions

Rheem Premier® Hiline 300L 52C300

MODEL 52C300Storage Capacity (L) 300Solar Collectors 2 NPT200Booster Type Electric or GasWeight Empty - (kg) Tank 109Hot Water Connection DN15 Compression

Cold Water Connection R 3/4

Features & Benefits

Complete frost protection

Energy efficient

Booster – choice of electric element or 6-Star continuous flow gas

Suitable for a range of water supplies

Eligible for STCs5

5 year cylinder warranty1

HOT WATEROUTLET

COLDWATERINLET

T.P.RVALVE

ELECTRICALCONNECTION 77

24252118

1022

19372475

508

2290

PEOPLE INSTALLATION

Outdoor2 - 5

Page 107: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

108

Rheem Collectors NPT200, LCS, CSA2007, SPA2000, T200, CSA2612, L

A

B

PIPE WORK TO SOLAR COLLECTORS2.0m2 Collector A B

1 Collector 1240 18752 Collector 2360 18753 Collector 3480 18753 Collector 3480 18752.6m2 Collector

1 Collector 1340 2165

COLLECTOR DATACollector Dimension Weight Kg

(empty)System

NPT200 1943 x 1027 x 82 36 direct/indirect

LCS 1943 x 1027 x 82 31 direct/indirect

CSA2007 1996 x 1043 x 82 36 direct/indirect

SPA2000 1996 x 1043 x 82 45 indirect

T200 1943 x 1027 x 82 48 indirect

CSA2612 2285 x 1130 x 82 47 direct

L 1943 x 1027 x 82 29 direct/indirect

INSTALLATION

Outdoor

Page 108: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

109

Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.3 60ºC and higher temperature models and some applications require a

tempering valve in accordance with AS 3500.4.4 Frost protection to 400m altitude above sea level5 Eligibility criteria apply.

Page 109: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

110

Page 110: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

Heat P

ump

111

Page 111: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

112

Scan code for details & installation

instructions

Page 112: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

113

Scan code for details & installation

instructions

HDi-310 551310

Features & Benefits

Top Down heating

No Solar collectors

Energy efficient

Back-up element – Provides hot water regardless of the weather

Fits on a compact footprint

LED display to indicate operating status

Eligible for STCs5

5 year cylinder warranty1

MODEL 551310Storage Capacity (L) 310Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 135

1075

820

1870

679

670643

100300MIN

300MIN

50O

30O

HOTOUTLET

AIRINLET

AIROUTLET

VENTILATIONCLEARANCE

TPRVALVE

CONDENSATEDRAIN

WALL

108

COLDOUTLET

PEOPLE INSTALLATION

Outdoor3 - 6

Page 113: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

114

Scan code for details & installation

instructions

MPi-325 Series II 551325

Features & Benefits

Multi-pass heating – Heats the water by passing the water through the heat exchanger multiple times

No Solar collectors

Back up electric element

One man installation – can be fully installed by plumbing regular trades

LED display to indicate operating status

Eligible for STCs5

5 year cylinder warranty1

MODEL 551325Storage Capacity (L) 325Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 130

57432O

300 MIN

894619 275

638

1631

1018

872

544

162

114

1317

100

WALL

AIR INLET

AIR INLET

AIROUTLET

TPRVALVE

HOTOUTLET

COLDINLET

CONDENSATE DRAIN

VENTILATIONCLEARANCE

VENTILATIONCLEARANCE

300 min

ELECTRICALCONNECTION

AIRINLET

AIROUTLET

PEOPLE INSTALLATION

Outdoor2 - 5

Page 114: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

115

Scan code for details & installation

instructions

MPi-325 Series II 554325

Features & Benefits

Inbuilt temperature control valve, adjustable to deliver 50ºC at first tap

Multi-pass heating

No Solar collectors

Back up electric element

One man installation – can be fully installed by plumbing regular trades

LED display to indicate operating status

Eligible for STCs5

5 year cylinder warranty1

MODEL 554325Storage Capacity (L) 325Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:

with ECV (kPa) 680without ECV (kPa) 800

Water Connections RP 3/4

Approx. Weight (Empty) kg 130

57432O

300 MIN

8941006

619 275

638

1636

1018

872

544

114

329

1317

100

WALL

AIR INLET

AIR INLET

AIROUTLET

TPRVALVE

HOTOUTLET

COLDINLET

CONDENSATE DRAIN

VENTILATIONCLEARANCE

VENTILATIONCLEARANCE

300 min

ELECTRICALCONNECTION

AIRINLET

AIROUTLET

PEOPLE INSTALLATION

Outdoor2 - 5

Page 115: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

116

Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product

warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater

models of the same capacity.3 60ºC and higher temperature models and some applications require a

tempering valve in accordance with AS 3500.4.4 Frost protection to 400m altitude above sea level5 Eligibility criteria apply.

Page 116: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

117

® Registered Trademarks of Rheem Australia Pty Ltd. Registered Trademark of COLORBOND Registered Trademark of Equa-flowTM Trademark of Dynabolt

Materials and specifications are subject to change without notice.

Page 117: Plumbers’ Handbook - Rheem · Plumbers’ Handbook ... or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.

®

Rheem Australia Pty LtdABN 21 098 823 511

Head Office1 Alan Street

Rydalmere NSW 2116

Australia

PO Box 7508

Silverwater NSW 2128

Australia

National Sales Phone: 132 552

National Service Phone: 131 031

www.rheem.com.au