Plugs Into CN61 On indoor PCB
1
11/03/22 5 6 4 Plugs Into CN61 On indoor PCB For Run/Fault Indication & Remote On/Off For VRF, DI & SDI( Part Numbe 6 5 4 3 2 1 Local on/off prohibit RUN SIGNAL COM (+12VDC) FAULT SIGNAL ON/Off Control 1 3 5 4 2 6 Max 10m between indoor PCB and relay ( Field Supplied ) For Run / Fault Indicatio n COM (Volt Free) 3 2 1 Used For Remote on/off (jumper 01 on master PCB must be cut – otherwise it responds to pulse) & local on/off control prohibit NOTE: NOT FOR USE WITH RAV-SM-XT RANGE
-
Upload
austin-wilcox -
Category
Documents
-
view
14 -
download
0
description
6. 5. 4. 3. 2. 1. Adaptor For Run/Fault Indication & Remote On/Off For VRF, DI & SDI( Part Number TRF ). 6. FAULT SIGNAL. For Run / Fault Indication. 5. COM (+12VDC). 6. 5. Plugs Into CN61 On indoor PCB. RUN SIGNAL. 4. 4. Local on/off prohibit. - PowerPoint PPT Presentation
Transcript of Plugs Into CN61 On indoor PCB
04/20/23
5
6
4Plugs
Into CN61On indoor PCB
Adaptor For Run/Fault Indication & Remote On/Off For VRF, DI & SDI( Part Number TRF )
6
5
4
3
2
1
Local on/off prohibit
RUN SIGNAL
COM (+12VDC)
FAULT SIGNAL
ON/Off Control1
3
5
4
2
6
Max 10m between indoor PCB and relay ( Field Supplied )
For Run / Fault Indication
COM (Volt Free)3
2
1
Used For Remote on/off (jumper 01 on master PCB must be cut – otherwise it responds to pulse) & local on/off control prohibit
NOTE: NOT FOR USE WITH RAV-SM-XT RANGE