PlexPower Fiber Panelboard Factory Sealed. Stainless Steel ...
Transcript of PlexPower Fiber Panelboard Factory Sealed. Stainless Steel ...
DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION PANELBOARDS
Visit our website at www.emerson.com or contact us at (800) 621-1506. © April 2021
323
PlexPower™ Fiber PanelboardFactory Sealed. Stainless Steel Enclosures. Panelboard with Fiber Patch Panel
NEC/CEC: Class I, Zone 1 and 2, AEx d e op pr IIB+H2 T3/T5 Gb Ex d e op pr IIB+H2 T3/T5 Gb Class I, Division 2, Groups B, C, D Class II, Division 1, Groups F, G IP66, Type 4X
Applications• ThePlexPower™fiberpanelboardprovidesindoorandoutdoor
protectionandcontrolofelectricalcircuitsinhazardousenvironmentssuchas:
—Petroleumplants —Chemicalplants —Refineries —WastewaterTreatmentPlants —PaperandPulpIndustries —Otherprocessfacilities• Idealforplacementinwet,corrosiveenvironmentsorwhere
flammablegasesorvaporsarelikelytobepresent.• Suitableforuseonapplicationswherebothpowerand
communicationwiringisrequired.
Features• Noexternalconduitorcablesealsrequiredthusmaking
installationsfaster,easier,andlesscostly.• ThePlexPowerFiberPanelboardfeaturesaground-breaking
designthatusesindividualbreakerhousingstominimizethedowntimeandcostsassociatedwithservicingcircuitbreakersinhazardouslocations.
• PlexPowerbreakersaccommodateoff-the-shelfbreakers,makingreplacementsreadilyavailable.
• Thelighterweightpanelboardenclosurecanbequicklyopenedinthefieldforeasierservicing.
• Suppliedwithstandardharddrawn,tinplated,copperbusbarforsuperiorcorrosionresistance.
• Glandplateatthebottomofenclosurecanbeeasilyfieldpunchedforcableorconduitentries.Additionalglandplatesavailableforsidesandtopmustbeorderedwiththepanelboard.Seeoptions.
• Standardmodelsoffer12circuitand24circuitpanelboardconfigurations.
• Standardconfigurationincludesinternalactuators.• Suppliedwithdeadfrontforinternalactuation.• Branchcircuitbreakersavailablein1-,2-,and3-pole.Current
ratingsonbranchbreakers: —1-pole:120Volts,60Ampsmaximum. —2-poleand3-pole:240Volts,40Ampsmaximum.• Breakerscanbeindividuallypadlockedineitherthe“On”or
“Off”position.• Breakermodulessuppliedwithstainlesssteelbolts.• Groundandorneutralbarsprovidedasstandard.• External/internalgroundlugprovidedasstandard.• 120/240Voltbreakermoduleterminalwirerange#14-1/0.• StandardmodelutilizesCutler-Hammer QCSeriesbreakers
andaBeldenMIPPTMFiberPatchPanel.• Panelboarddesignedfor-20°Cto+40°C(-4°Fto+104°F)
operation.• Ambienttemperaturerangeof-40°Cto+40°C
(-40°Fto+104°F)availablewithheateroptions.
Standard Materials• Enclosure:316Lstainlesssteel• Hardware:stainlesssteel• Busbar:harddrawn,tinplated,copper
Panels with QC1050N and fuses are Zone 2 rated only. Certification only applies without drain/breather. IP66, Type 4X Certification only applies with drain/breather. Cutler-Hammer is a registered trademark of Eaton Corporation. Belden is a registered trademark Belden Inc.
Fiber Panelboard
Internal View
Illustrated Features
Standard Bus Bar Fiber Patch Panel
DIST
RIBU
TION
EQUI
PMEN
T: NE
C/CE
C HA
ZARD
OUS L
OCAT
ION
PANE
LBOA
RDS
Visit our website at www.emerson.com or contact us at (800) 621-1506. © April 2021
324
Panels with QC1050N and fuses are Zone 2 rated only. Certification only applies without drain/breather. IP66, Type 4X Certification only applies with drain/breather. For panels certified to -40 °C (-40 °F), enclosure size may need to increase Terminal blocks not available when fusible disconnects are used. Maximum amperage for branch breakers is 40 Amps when TB option is selected.
Options Must be listed in alphanumeric sequence at the end of the catalog number.
• Externalactuation,addsuffix—EXT.• Drain/Breather,addsuffix—DV.• Groundedneutral,addsuffix—GN.• Glandplate,specifysuffixGPL=leftside,GPR=rightside,
GPT=topside,NGP=noglandplate).• Heaterforanti-condensation,-20°C(-4°F)k
—ForClassI,Division2,GroupsB,C,DandClassI,Zone2equivalency,addsuffix—HTR.
— ForClassIZone1certification,addsuffix—HTRF.–Certificationslistedattopofpageapply.
• Heaterforpanelscertifiedto-40°C(-40°F)ambient temperature, —ForClassI,Division2GroupsB,C,DClassI,Zone2
equivalency,addsuffix—HTR40.—ForClassI,Zone1certification,addsuffix—HTRF40. –Certificationslistedattopofpageapply.
• LEDindicatorlights,addsuffix—IL.• Phenolic/lamacoidnameplate(specifylegend),addsuffix—NP.• Doorpadlockingprovision,addsuffix—P.• Terminalblocksinsteadofdirectwiring,addsuffix—TB n.• Roxteccableentrysystem(supports100%sparefibers),
addsuffix—ROX.• Sparefiberpairsforeachbranchcircuit
—100%sparefiberpairs,addsuffix—SF1.—200%sparefiberpairs,addsuffix—SF2.—300%sparefiberpairs,addsuffix—SF3.
NEC/CEC Certifications and Compliances• ULStandards:UL67,UL1203,4thEd.,ANSI/ISA-12.12.01-
2015,ANSI/UL60079-0,5thEd.,ANSI/UL60079-1,5thEd.,ANSI/UL60079-7,4thEd.,UL60079-28–17,2ndEd., UL50E-1stEd.
• CSAStandards:C22.2No.0–10,C22.2No.29-M1989,C22.2No.25-1966,C22.2No213–16,C22.2No.60079-0:07,E60079-7-03,C22.2No.60079-1:07,C22.2No.60079-28:162ndEd.,C22.2No.94.2-07
• cCSAusCertified:039199
Patents• HybridPowerandFiberOpticDistributionPanels
—UnitedStatesPatentUS10,574,035B2—FiledFeb8,2019andissuedFeb25,2020
Related Products• RecommendedforusewiththeAppletonTCCableConnector.• AdditionalPlexPower™products: —PlexPower™FactorySealedEnclosedCircuitBreakers
—PlexPower™FusedFactorySealedPanelboard —PlexPower™ContactorandMotorStarters —PlexPower™FactorySealedPanelboards
PlexPower™ Fiber PanelboardFactory Sealed. Stainless Steel Enclosures. Panelboard with Fiber Patch Panel
NEC/CEC: Class I, Zone 1 and 2, AEx d e op pr IIB+H2 T3/T5 Gb Ex d e op pr IIB+H2 T3/T5 Gb Class I, Division 2, Groups B, C, D Class II, Division 1, Groups F, G IP66, Type 4X
DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION PANELBOARDS
Visit our website at www.emerson.com or contact us at (800) 621-1506. © April 2021
325
PlexPower™ Fiber PanelboardFactory Sealed. Stainless Steel Enclosures. Panelboard with Fiber Patch Panel
NEC/CEC: Class I, Zone 1 and 2, AEx d e op pr IIB+H2 T3/T5 Gb Ex d e op pr IIB+H2 T3/T5 Gb Class I, Division 2, Groups B, C, D Class II, Division 1, Groups F, G IP66, Type 4X
Panels with QC1050N and fuses are Zone 2 rated only. Certification only applies without drain/breather. IP66, Type 4X Certification only applies with drain/breather 40A is the maximum amperage for 2 or 3 pole branch breaker. Fusible disconnect can only use single pole. See page 326 for Fiber Optic Connectors available. Reference the Belden or Telegartner catalog for connector type (no pigtail accessories provided) Fields are omitted from the short, abbreviated catalog numbers to save space for the ERP system.
RC S I 1 1 L 12 000 01 20 1 GFI BL ST #
NEC/CECCertified
RC-PlexPowerFiberPanel
Operating Voltage:
1-120/2402-2403-120/208
Circuits:06121824
FuseorBranchBreakers Comm Manuf:
BL-BeldenTL-Telegartner
FuseAmperage
01020304050607080910
Branch Breakers
Amperage:15202530405060
Panel Material:S-Stainless
Steel
Bus Rating:
1-150Amp
Main Amperage:000-Lugs
Poles:1-Single2-Two
Fiber Connect
Type:STSCLC
Main:L-Lugs
BranchQty:1-24
GFI:Blank
GFI-5mAGFIEPD-30mAEPDFDF-Fastacting
fusibledisconnect
FDT-Timedelayfusibledisconnect
Other Options:RefertoOptionsSection
PanelSize:SelectI1orE1stainlesssteelenclosurebasedonnumberofcircuits
I1875x750x250
E1 1130x750x250
Max.Circuits 6,12 18,24
Panel Size
Dimensions in Millimeters (Inches)
I1 E1
Length 875(34.50) 1130(45.00)
Width 750(29.50) 750(29.50)
Depth 250(10.00) 250(10.00)
Abbreviated Standard Part Numbers Full Catalog Number Description
RCS12201BL RCSI111L1200012201BLST-TB Twelvesinglepole20AbreakerswithBeldenMIPPfiberpatchpanelandSTfiberconnectors
RCS24201BL RCSE111L2400024201BLST-TB Twenty-foursinglepole20AbreakerswithBeldenMIPPfiberpatchpanelandSTfiberconnectors
RCS12F10BLRS3 RCSI111L12000-12101FDF-BL-ST-NP-ROX-SF3
Twelvesinglepole10AfusibledisconnectswithBeldenMIPPfiberpatchpanelandSTfiberconnectors,300%sparefiberconnectionsandRoxteccablemanagementsystem.
DIST
RIBU
TION
EQUI
PMEN
T: NE
C/CE
C HA
ZARD
OUS L
OCAT
ION
PANE
LBOA
RDS
Visit our website at www.emerson.com or contact us at (800) 621-1506. © April 2021
326
Panels with QC1050N and fuses are Zone 2 rated only. Certification only applies without drain/breather. IP66, Type 4X Certification only applies with drain/breather Fiber splice box only provides Application -SM/OS2 UPC and ‘No accessories’(XX9N). Please refer to the latest Belden MIPP catalog for defining the MIPP Configuration.
PlexPower™ Fiber PanelboardFactory Sealed. Stainless Steel Enclosures. Panelboard with Fiber Patch Panel
NEC/CEC: Class I, Zone 1 and 2, AEx d e op pr IIB+H2 T3/T5 Gb Ex d e op pr IIB+H2 T3/T5 Gb Class I, Division 2, Groups B, C, D Class II, Division 1, Groups F, G IP66, Type 4X
Fiber Optic Connectors Available The below fiber option connectors are available to be used in the PlexPower Fiber panel. The ST connectors are provided by default in the standard products, however the LC and SC connectors can be used in the engineer to order product.
ST Connector LC Connector SC Connector
TheSTconnectorusesahalf-twistbayonettypeoflock.
TheLCconnectorusesalatchthatenablesapushon/pulloffoperationandisthe
smallestconnectorsize.
TheSCconnectorusesalockingtabthatenablesapushon/pulloffoperation.
DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION PANELBOARDS
Visit our website at www.emerson.com or contact us at (800) 621-1506. © April 2021
327
PlexPower™ Fiber PanelboardFactory Sealed. Stainless Steel Enclosures. Panelboard with Fiber Patch Panel
NEC/CEC: Class I, Zone 1 and 2, AEx d e op pr IIB+H2 T3/T5 Gb Ex d e op pr IIB+H2 T3/T5 Gb Class I, Division 2, Groups B, C, D Class II, Division 1, Groups F, G IP66, Type 4X
Panels with QC1050N and fuses are Zone 2 rated only. Certification only applies without drain/breather. IP66, Type 4X Certification only applies with drain/breather.
RCS-Frame with Main Lugs Dimensions in Millimeters (Inches)
12 Circuit
Front View Internal View Side View
875(34.45)
750(29.53)
250(9.85)
24 CircuitFront View Internal View Side View
1130(44.49)
750(29.53)
250(9.85)