PLEASE FOLLOW THE ASSEMBLY INSTRUCTIONS CLOSELY. …

9
Fig. 1 WARNING: DO NOT LOOSE THESE NYLON SET-SCREWS, THESE SCREWS NOT FOR ADJUSTMENT. Page 1 of 9 PARTS ENCLOSED: (A) 25W LED Driver (1) - Put Into Canopy (B) Mounting Plate (1) (C) Canopy (1) (D) Hex Nut (1) (E) Ring Terminals W/ Bare Ground Wire (1) (F) Tooth Lock Washer (1) (G) 3/16”L Hex Socket Set-screws (3) (H) 3/4”L Threaded Nipple (1) (I) Hanging Mechanism (1) (J) 19” Extension Threaded pipes (2) (K) 18” Extension Rods (2) (L) 13” Extension Threaded pipes (2) (M) 12” Extension Rods (2) (N) 7” Extension Threaded pipes (2) (O) 6” Extension Rods (2) (P) Couplings (6) (Q) 10/64”L Hex Socket Set-screw (1) (R) Threaded Head (1) (S) Crystal Balls (6) (T) PVC Rings (6) (U) Hexagonal Plates (6) PLEASE FOLLOW THE ASSEMBLY INSTRUCTIONS CLOSELY. IMPROPER ASSEMBLY CAN RESULT IN PERSONAL OR PROPERTY DAMAGE. IF YOU ARE UNSURE ABOUT YOUR CEILING TYPE OR WHAT MOUNTING METHOD YOU SHOULD USE, CONSULT A QUALIFIED PROFESSIONAL OR YOUR LOCAL HARDWARE STORE. Bare Ground Wire (B) (C) (H) (G) (I) (J) (K) (R) (L) (M) (N) (O) (P) (A) (P) (Q) (S) (T) (U) Joint Seam ALIGN THE JOINT SEAM TO THE METAL RING OF FIXTURE Metal Ring (U) (S) (T) Metal Ring Strain Reliefs (x6) W/ Set-screws Textile Power Cords (x6) (D) (E) (F) Suitable Mounting Screws (x6) (Not included) Fixture’s Low Voltage 12V Wires (x2) From Cord Box Pass Through The Extension Pipes. See Wiring Description & Diagram. Labeled Wires - A1 A1 +12V A1 -12V Cord Box Existing Ceiling Safety Cable Min. Dia. 1/8” (Not included) Cable Lock Nut Fixture Safety Cable REFER TO PAGE-2 FOR DETAILED SAFETY CABLE ASSEMBLY ECLATANT 36IN ROUND CHANDELIER

Transcript of PLEASE FOLLOW THE ASSEMBLY INSTRUCTIONS CLOSELY. …

Fig. 1

WARNING:DO NOT LOOSE THESE NYLON SET-SCREWS,THESE SCREWS NOT FOR ADJUSTMENT.

Page 1 of 9

PARTS ENCLOSED:

(A) 25W LED Driver (1) - Put Into Canopy

(B) Mounting Plate (1)

(C) Canopy (1)

(D) Hex Nut (1)

(E) Ring Terminals W/ Bare Ground Wire (1)

(F) Tooth Lock Washer (1)

(G) 3/16”L Hex Socket Set-screws (3)

(H) 3/4”L Threaded Nipple (1)

(I) Hanging Mechanism (1)

(J) 19” Extension Threaded pipes (2)

(K) 18” Extension Rods (2)

(L) 13” Extension Threaded pipes (2)

(M) 12” Extension Rods (2)

(N) 7” Extension Threaded pipes (2)

(O) 6” Extension Rods (2)

(P) Couplings (6)

(Q) 10/64”L Hex Socket Set-screw (1)

(R) Threaded Head (1)

(S) Crystal Balls (6)

(T) PVC Rings (6)

(U) Hexagonal Plates (6)

PLEASE FOLLOW THE ASSEMBLY INSTRUCTIONS

CLOSELY. IMPROPER ASSEMBLY CAN RESULT

IN PERSONAL OR PROPERTY DAMAGE. IF YOU

ARE UNSURE ABOUT YOUR CEILING TYPE OR

WHAT MOUNTING METHOD YOU SHOULD USE,

CONSULT A QUALIFIED PROFESSIONAL OR

YOUR LOCAL HARDWARE STORE.

Bare Ground Wire

(B)

(C)

(H)

(G)

(I)

(J) (K)

(R)

(L) (M)

(N) (O)

(P)

(A)

(P)

(Q)

(S)

(T)

(U)

Joint Seam

ALIGN THE JOINT SEAM TOTHE METAL RING OF FIXTURE

Metal Ring

(U)

(S)

(T)

Metal Ring

Strain Reliefs (x6)W/ Set-screws

Textile Power Cords (x6)

(D)

(E)

(F)

Suitable Mounting Screws (x6)(Not included)

Fixture’s Low Voltage 12V Wires (x2) From Cord Box Pass Through The Extension Pipes.See Wiring Description & Diagram.

Labeled Wires - A1

A1 +12V

A1 -12V

Cord Box

Existing Ceiling Safety Cable Min. Dia. 1/8” (Not included)

Cable Lock Nut

Fixture Safety Cable

REFER TO PAGE-2 FORDETAILED SAFETY CABLE ASSEMBLY

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

Page 2 of 9

SAFETY CABLE ASSEMBLY

1. Remove Hex Nut from Cable Lock Nut and pull Cable Lock Nut from Safety Cable.

2. Join Fixture Safety Cable with Safety Cable from ceiling and wrap both safety cables around the cable lock nut.

3. Secure by tightening both Hex Nuts until tight.

Ceiling SafetyCable

Fixture SafetyCable

A2

Hex NutsCableLock Nut

A3

Hex NutsCableLock Nut

Safety Cable

A1

(Not included)

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

Page 3 of 9

WIRING DESCRIPTION

CAUTION:- Always follow local electrical code regulations when installing LED drivers & fixtures.- DO NOT attach 0-10V dimming wires to hot / line voltage wire.- Leave wire caps on 0-10V dimming wires when not in use to prevent short circuit.- For LTF UniDriver power supplies, DO NOT install / use ELV and 0-10V dimmers simultaneously on one driver.

LABELED WIRES - A1

LABELED WIRES - A1

TOP RING - LED STRIPS LOCATION x6(WITHIN THE OCTAGONAL PARTS)

LED CIRCLE ARRAY LOCATION x1(WITHIN THE CORD BOX)

25W LED DRIVER (x1)CONNECT WITH LED STRIPS+LED CIRCLE ARRAY (LABELED WIRES - A1)

INSTALLATION LOCATION:PUT INTO CANOPY

FIXTURE’S LABELED WIRES (x2)

LABELED WIRES - A1

25WLED DRIVER

RED +12VBLUE -12V

BLACKWHITEGREEN

Labeled Wires - A1

A1 +12V

A1 -12V

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

Page 4 of 9

WALL DIMMER BUYING GUIDE

Wall Dimmer Model Dimmability

PASS & SEYMOUR / LEGRAND"Harmony"

D703PNIV

LUTRON "DIVA"

DVELV-300P

LEVITONUniversal, "DECORA SMART"

Dimmer w/Wi-Fi Technology

DW6HD

Best Performance, Dimming capability: +/- 5% < 100 % > 5%

Excellent

Good

Acceptable

Good Performance, Dimming capability: +/- 10% < 100 % > 10%

Acceptable Performance, Dimming capability: +/- 20% < 100 % > 20%

WARNING: DO NOT HOOK UP THESE FIXTURES TO MECHANICAL DIMMERS,

IT WILL PERMANENTLY DAMAGE THE COMPONENTS.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

ELVDIMMER

HOT/LINE

BLACK

COMMON/NEUTRAL

WHITE

YELLOW

WHITE

BLACK

LINEVOLTAGE

120V

120V OUTPUT

LED LOADLOW VOLTAGE DC

BARE

FIXTURE GROUND WIREEARTH/GROUND

LED DRIVER

GROUND GREEN

Page 5 of 9

WIRING DIAGRAM

Reverse phase ELV wiring diagram

CAUTION:- Always follow local electrical code regulations when installing LED drivers & fixtures.- DO NOT attach 0-10V dimming wires to hot / line voltage wire.- Leave wire caps on 0-10V dimming wires when not in use to prevent short circuit.- For LTF UniDriver power supplies, DO NOT install / use ELV and 0-10V dimmers simultaneously on one driver.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

120V OUTPUT

TRIACDIMMER

COMMON/NEUTRAL

WHITE

HOT/LINE

BLACK LINEVOLTAGE

120V

BLACK

WHITE

LED LOADLOW VOLTAGE DC

BARE

EARTH/GROUND

LED DRIVER

GROUND GREEN

FIXTURE GROUND WIRE

Page 6 of 9

WIRING DIAGRAM

TRIAC dimming wiring diagram

CAUTION:- Always follow local electrical code regulations when installing LED drivers & fixtures.- DO NOT attach 0-10V dimming wires to hot / line voltage wire.- Leave wire caps on 0-10V dimming wires when not in use to prevent short circuit.- For LTF UniDriver power supplies, DO NOT install / use ELV and 0-10V dimmers simultaneously on one driver.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

120V OUTPUT

COMMON/NEUTRAL

WHITE

HOT/LINE

BLACK LINEVOLTAGE

120V

BLACK

WHITE

LED LOADLOW VOLTAGE DC

BARE

EARTH/GROUND

LED DRIVER

GROUND GREEN

FIXTURE GROUND WIRE

Page 7 of 9

WIRING DIAGRAM

Non-dimming wiring diagram

CAUTION:- Always follow local electrical code regulations when installing LED drivers & fixtures.- DO NOT attach 0-10V dimming wires to hot / line voltage wire.- Leave wire caps on 0-10V dimming wires when not in use to prevent short circuit.- For LTF UniDriver power supplies, DO NOT install / use ELV and 0-10V dimmers simultaneously on one driver.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

Page 8 of 9

IMPORTANT PLEASE READ ASSEMBLY & INSTALLATION:

1. Carefully remove all parts from the box and remove all plastic covering.

2. Determine the hanging length of pendant. Connect Threaded Head (R) to some or all Connection Rods (K)(M)(O) , Connection Threaded Pipes (J)(L)(N) & Couplings (P) according to the height needed; Secure the first Threaded Pipe with Hex Socket Set-screw (Q); feed wires & safety cable through the Connection Threaded Pipes at the same time.

3. Connect the Hanging Mechanism (I) to Connection Threaded Pipe.

4. Attach Canopy (C) & Tooth Lock Washer (F) & Ring Termianls W/ Bare Ground Wires (E) to Hanging Mechanism (I) and secure with Hex Nut (D) & 1”L Threaded Nipple (H); feed wires through the 1”L Threaded Nipple (H) at the same time; the wires will come out on backside of the Canopy (C).

5. Carefully inspect the pendant’s fixture wires. (See Page-3.) Black Color is the +12V WIRE. White Color is the -12V WIRE. Bare Wire on Canopy (C ) is the GROUND WIRE.

6. Carefully inspect the LED Driver wires. (See Page-3 & Label on LED Driver.) Red Color is the +12V WIRE. Blue Color is the -12V WIRE. Green Color is the GROUND WIRE. White Color is the NEUTRAL WIRE. Black Color is the HOT WIRE. Bare wire on Canopy(C) is the GROUND WIRE

7. Connect the pendant’s fixture +12V WIRE with LED Driver +12V WIRE, then Connect the pendant’s fixture -12V WIRE with LED Driver -12V WIRE. WARNING: DO NOT CONNECT THE LOW VOLTAGE 12V LABELED WIRES DIRECTLY TO 120V POWER SUPPLY.

8. Attach Mounting Plate (B) to ceiling’s outlet box and secure with (x6) Suitable Moungting Screws (Not Included) and proper fasteners from your local hardware store.

9. Carefully lift up the Canopy (C) with the light fixture and place it close to outlet box for connect Safety Cable & wiring.

10. Connect the Safety Cable from the fixture and the Existing Safety Cable (Not included) from ceiling using Cable Lock Nut. (See Page-2.)

11. Connect the GREEN GROUND WIRE & BARE GOUND WIRE from the fixture with the ground wire (usually bare) from your outlet box using a wire nut.(See Page-5,6,7). If your house does not have ground wire, then attach the GROUND WIRE from the fixture to the green grounding screw inside of the outlet box. IT IS IMPERATIVE THAT THE OUTLET BOX IN YOUR HOME BE PROPERLY GROUNDED.

12. FOR DIMMING, choosing the Wall Dimmer (See Page-4) then follow the WIRING DIAGRAM (See Page-3,5,6) to inspect & connect the wires according to the Dimming Function (ELV / TRIAC) of your Dimmer.

13. FOR NON-DIMMING, follow the WIRING DIAGRAM (See Page-7) to Connect the NEUTRAL WIRE from your fixture with the neutral wire (usually white) from your outlet box using a wire nut.

SAFETY INSTRUCTIONS:

(1) Must use an authorized and certified electrician for consultation

and installation. Electrician must be familiar with commercial-type

application of very heavy ceiling lamp and hazards involved.

Electrician should install it as per applicable local installation code.

(2) This fixture must be mounted to the ceiling independent of an

outlet box. Your ceiling may require modification to allow the

mounting plate to be secured to a structural member. This

fixture MUST NOT be secured using any type of hollow ceiling

anchor, such as a toggle bolt.

(3) FOR NONCOMBUSTIBLE SURFACE ONLY.

(4) This fixture MUST BE connect the Fixture Safety Cable to theCeiling Safety Cable. Your ceiling may require modification to provide the Ceiling Safety Cable (Min. Dia. 1/8”).

(5) This fixture has been rated for (6) 2.5-watt maximum 12VDC LED Strips & (1) 3-watt maximum 12VDC LED Disc (included). To avoid the risk of fire,do not exceed the recommended wattage.

(6) The manufacturer and distributor accept no liability for incorrect installation.

(7) Keep away from children.

WARNINGS:All wires are connected. When unpacking, be careful not to pull wires as a bad connection may result. Do not connect electricity until your fixture is fully assembled. Do not touch the LED modulewhen fixture is turned on or look directly at lit bulb. Keep flammablematerials away from LED module.

THIS IS NOT A TOY AND THE PRODUCT HASNO PLAY VALUE

CARE INSTRUCTIONS:Wipe all surfaces with a soft dry cloth. Clean glass with a mildsoap and water mixture. Do not use any harsh cleaners (includingammonia-based products) or abrasives, as they will damagethe finish.

WARNING: STRANGULATION HAZARD Keep cord at least 3 ft away from cribs, bassinets, and toddler beds. Keep out of reach of children under 3.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R

Page 9 of 9

ASSEMBLY & INSTALLATION CONT:

14. FOR NON-DIMMING, follow the WIRING DIAGRAM (See Page-7) to Connect the HOT WIRE from your fixture with the hot wire (usually black) from your outlet box using a wire nut. DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS; OTHERWISE, SAFETY WILL BE COMPROMISED.

15. Tuck the wire connections neatly into the ceiling’s outlet box.

16. Attach Canopy (C) with light fixture to affixed Mounting Plate (B) and secure with (x3) 1/4"L Hex Socket Set-screws (G).

17. Carefully put the PVC Rings (T) & Crystal Balls (S) seat on the Hexagonal Plate (U); align the PVC Ring’s joint seam to the Metal Ring before install the Crystal balls (S). (See Fig. 1.)

18. Assembly is complete.

E C L A T A N T 3 6 I N R O U N D C H A N D E L I E R