Plc Fx Family
-
Upload
imam-rosyada-rijalulhaq -
Category
Documents
-
view
220 -
download
0
Transcript of Plc Fx Family
-
7/25/2019 Plc Fx Family
1/90
MITSUBISHIELECTRIC
FACTORY AUTOMATION
MELSEC PLC
ALPHA /// FX1S /// FX1N /// FX2N
/// FX2NC /// FX3U ///
-
7/25/2019 Plc Fx Family
2/902 MITSUBISHI ELECTRIC
System Q, AnSH, QnASH Technical Catalogues
Product catalogues for programmable logic controllers andaccessories for the further MELSEC PLC series
Networks Technical CatalogueProduct catalogue for Master and Slave modules as well asaccessories for the use of programmable logic controllers inopen and MELSEC networks
HMI Technical Catalogue
Product catalogue for operator terminals, supervision softwareand accessories
Technical
Catalogues
Further Publications within the PLC Range
More information?
This technical catalogue is designed to give an overview of the extensive range of FX Family of MELSEC PLCs.If you cannot find theinformation you require in thiscatalogue, there area numberof ways you can get furtherdetails on configurationand technical issues,pricing and availability.
For technical issues visit the www.mitsubishi-automation.comwebsite.
Our website provides a simpleand fast way of accessing furthertechnical data and up to the minute detailson our products andservices.Manuals and catalogues are available in several different languages and can be downloaded forfree.
For technical,configuration,pricing and availability issues contact our distributors and partners.
Mitsubishi partnersand distributors are only toohappy to help answeryour technical questions or helpwith configuration building.For a list of Mitsubishi partners please see thebackof this catalogueor alternatively take a look at the contactussection of our website.
About this technical catalogue
This catalogue is a guide to the range of products available.For detailed configuration rules,system building, installation and configura-
tion the associatedproduct manuals must be read.You must satisfy yourself that any system you design with the products in thiscata-logue is fit forpurpose,meets your requires and conforms to theproduct configuration rules as defined in the product manuals.
Specifications are subjectto change without notice.All trademarks acknowledged.
Mitsubishi Electric Europe B.V., Factory Automation - European Business Group 11/2005 (Version A)
-
7/25/2019 Plc Fx Family
3/903MITSUBISHI ELECTRIC
SystemDescription
ALPHA and MELSEC PLC system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Extension modules and special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1ALPHA Controllers Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Extension units and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2MELSECFXBaseUnits FX1S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FX1N series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
FX2N series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
FX2NC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
FX3U series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3MELSECFXExtensionUnits System configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Powered compact extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Unpowered modular extension blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4MELSECFXSpecial FunctionModules Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
High-speed counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Positioning modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Network modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Communications modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Adapter boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
5 Accessories Memory media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Terminal blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Connection cables, backup batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Display modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6 Terminals andDimensions
TERMINALLAYOUT Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Extension units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Terminal blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
DIMENSIONS
Base and extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
7 Software& Programming Trainings and programming software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Programming units and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
/// CONTENTS
-
7/25/2019 Plc Fx Family
4/904 MITSUBISHI ELECTRIC
Expandability andPower
The MELSEC FX family is highly flexible,enabling fast and efficient configurationand programming for the application athand.
It is the ideal choice, no matterwhetheryou need to install a simple controlapplication requiring 10 I/Os (FX1S) o r ademanding, complex system with up to384 I/Opoints (FX3U).
The use of memory cassettes can expandthe available programming space on some
FX Family PLCs while generally providing along term program storage option forallFX PLC users.In addition,memory cas-settes can alsoallow programs to beswitched at very short notice simply byreplacing the cassette.
There are five series in the MELSEC FXfamily, each of which is designed for adifferent application profile:
The FX1S Series
The MELSEC FX1S series is theinexpensiveentry tothe MELSEC FX family.With itssmall dimensionsit is alsoan excellent
alternative to relay/contactor controlconfigurations.
The FX1N Series
The CPUs of the FX1N series offer morepower than theFX1S series, plus modularexpansion capabilities.You can choosefrom I/O expansion modules and specialfunction modules fora wide varietyofapplications.
The FX2N Series
The FX2N seriescomplements the existingFX family.It gives you thefreedomofmodular expandability, with a wideselection of expansion modules andspecial functionmodules.
The FX2N is also one of thefastest PLC sys-tems available,witha cycle timeof 0.08 sper logical instruction.
The FX2NC Series
The performance of the FX2NC is the sameasthat oftheFX2N series, but it has morecompact dimensions.It is the ideal choiceforapplications where little space is avail-able forthe controller.
The FX3U Series
The FX3U series is the newest member ofthe FX family.It gives you thefreedomofmodular expandability, with a wideselection of expansion modules andspecial functionmodules.
The FX3U is the fastest PLC systems avail-able,witha cycle time of just 0.065 s perlogicalinstruction. This gives users apowerful CPUdelivering modularPLCperformance in a compact PLC design.
FX1S FX1N FX2N 2NC/FX
8.0
00*
2.0
00
16
.000*
34
132
256
0,
08
0,5
5
0,
7
0,
55
0,7
FX3U
64
.000
384
0,
065
TheALPHASeries
The ALPHA closes the gap between singlecomponents and a PLC system. It com-bines alladvantages of a PLC system in avery compact housing and thereforepro-vides a space and cost saving alternativeto relays and contactors.
The ALPHA series is suited to applicationsin industrial machines and in automatedbuilding services.
Key enhancements in the ALPHA2 includea program capacity of 200 function blocks,an extra-large display,expansion optionsand a second communications port. Theinstruction set,includes math operations,PWM and SMS text messaging functions.All this opens up possibilities foranalogand temperature control as well as remoteoperation.
TheMELSECFXFamily
The MELSEC FX family includes a verycomprehensive range of baseand expan-sion modules,enabling you to configurea customised system tailored to yourprecise requirements.
Depending on your applicationand con-trol needs you can choose fromthe small,attractively-priced,stand-aloneFX 1Sseries, the expandable FX1N series or themore powerful FX2N/FX2NC and FX3Useries.
With theexception of theFX1S allFX seriescan be expanded toadapt them tothechanging needs of your installations andapplications.
Network integrationis also supported,making it possible for your FX controllersto communicate with other PLCs,control-lers andHMIs.The PLC systemscan becon-
figured as local stations in MITSUBISHI net-works. In addition these flexible units canalso be used as master or slaveunits onfieldbuss like Profibus/DP and CC-Link.
The MELSEC FX Family controllers alsosupport CANopen, DeviceNet andEthernet.
ALPHA and MELSEC PLC Systems
SYSTEMDESCRIPTION ///
MITSUBISHI
0 1 2 3
4 5 6 7
8 9 10 11
12 131415
0 1 2 34 5 6 7
10 11
IN
OUT
POWER
FX -24 MR1N
RUN
ERROR
100-240
VAC
X7 X 11X1 3 X15
X5X3X1S/S X6 X1 0 X 12X 14
X4X2X0NL
24MR-ES/UL
Y10Y6Y5Y3
COM3 Y 4 COM4 Y7 Y11
COM2COM1COM024+
Y2Y1Y00V
012 3456 7
012 3
45
IN
OUT
POWER
FX -14 MR1S
RUN
ERROR
MITSUBISHI
X7X5X3X1S/S X6X4X2X0NL100-240
VAC
14MR-ES/UL
Y4Y2Y1Y0
COM0COM1COM2Y 3 Y5
24V0V
POWERRUNBATT
ERROR
X0X1X2X3X4X5X6X7X8X9X10X11X12X13X14X15X16X17
X20X21X22X23X24X25X26X27X28X29X30X31X32X33X34X35X36X37
Y0Y1Y2Y3Y4Y5Y6Y7Y8Y9Y10Y11Y12Y13Y14Y15Y16Y17
Y20Y21Y22Y23Y24Y25Y26Y27Y28Y29Y30Y31Y32Y33Y34Y35Y36Y37
RUN
STOP
MITSUBISHI
FX -6 4MT2NCML
S
POWERDC24V
DC INPUT
ESC
OK
+
-
AL-20MR-D
RELAYOUTPUT
MITSUBISHI
1 7
+ - 6
125
114
103
92
8IN
-
7/25/2019 Plc Fx Family
5/905MITSUBISHI ELECTRIC
DIGITALE
EIN-/AUSGNGE
POSITIONIER-
MODULE
KOMMUNI-
KATIONS-
MODULE
ANALOGE
EIN-/AUS-
GNGE
DIGITAL
INPUTS/OUTPUTS
POSITIONING
MODULES
COMMUNI-
CATIONS-
MODULES
ANALOG
INPUTS/
OUTPUTS
CPUCPU
Digital and special functionmodules configuration
The options for using digital and specialfunction modules aredictated by the CPUused in the system.
When calculatingthe numberof specialfunctionmodules you can use in a systemyou must take both thenumber of digitalmodules and the maximum number ofspecialfunction modules that can be usedinto account.
The table on the right provides a simplifiedguide tothe number of modules you canuse in each system type. More detailedinformation and thebasic principles ofsystem configuration can be found in thecorresponding manuals.
CPU type System restrictions
FX1S
FX1N
FX2N
FX2NC
FX3U
Features
Analog I/Omodules
For processing current/voltagesignals and temperature registrationwith a direct connection option forPT100 resistance thermometers andthermocouplers
Positioningmodules
High-speed counter modules with supportforthe connection of incremental rotarytransducers and positioning modules forservo and stepping motor drives
Communicationsmodules
Interface modules withRS232/RS422/RS485 interfacesforthe connectionof peripher-als and PLCPLClinks.
Network modules for Ethernet,Profibus/DP,CC-Link,AS-Inter-face,DeviceNet,CANopenandforthe configurationof propri-etary Mitsubishinetworks
Themodular design of the FX family makesit extremely flexible,enabling it to be usedfora verybroad range of applications.
You can configure tailor-made systems
by combining modules froma varietyofdifferent categories (see figure).
All modules areelectrically isolated fromtheir environment with optocouplers formaximum reliability.
DigitalI/Omodules
For a variety of signallevels withrelay ortransistor switches
/// SYSTEMDESCRIPTION
-
7/25/2019 Plc Fx Family
6/906 MITSUBISHI ELECTRIC
SYSTEMDESCRIPTION ///
A basicFX PLC system can consist of astand alone baseunit,with the functio-nality and I/O range increased by addingextension I/O and specialfunction mod-
ules.The following sectionprovides anoverview of optionsavailable.
Base Units
The entire FX PLC range can be AC or DCpowered with a mix of input and outputstyles.The PLCs can be programmed withthe user friendly GX or GX IECDeveloperprogramming software,allowing pro-grams to be transferred between differentFX PLCs.All PLC base units includean inte-gratedreal time clock.
Baseunits areavailable with different I/Oconfigurations from 10 to 128 points but
can be expanded to 384 points dependingupon the FX range selected.
Extension Boards
Extension adapter boards can be installeddirectly into the baseunit and thereforedo not require any additional installationspace.For a smallnumberof I/O (2 to 4) anextension adapterboardscan be installeddirectly into the (left-hand side) FX1S orFX1N controller. Interface adapter boardscan also providethe FX PLC with addi-tional RS232 or RS485interfaces.Tocon-nect special function modles (e.g.Ethernetmodule) a communication adapterhas tobe installed.
Extension I/OModules
Unpoweredand powered extension I/Omodules can beadded to theFX1N/FX2Nand FX3U PLCs.For expansion modules
powered by the baseunit,the power con-sumption has tobe calculated as the5 VDC bus can only support a limited number
of expansion I/O (for further details pleaserefer to next page calculation of thepower consumption).
Special FunctionModulesA wide variety of specialfunction modulesareavailablefor the FX1N, FX2N and FX3UPLCs.They cover networking functionality,analog control,pulse train outputsandtemperature inputs.
Peripherals
Each FX PLC hasoptions for memory cas-settes, hand held programming units aswell as connection to HMI andGOT inter-faces.
The Components for an FX PLC System
Expansion possibilities ALPHA FX1S FX1N FX2N FX2NC FX3U Reference page
11, 46
11, 46
29
33
11, 34
12, 39
38
43
40
41
43
48
48
47
45
44
36 37
12, 49
53
FX
16
LNK
M
2N
OD
ER
R
8
9
2
A
3
B
O
NLLINE ST ION
4
C
5
D
6
E
7
F
1
2 3
O
FF
ON
O
FF
ON
OFF
O
N
RR
OR
ST
TIO
N
IN
POWER
0N -3AFX
-
7/25/2019 Plc Fx Family
7/907MITSUBISHI ELECTRIC
The power consumption figures on the5 V DC bus for the specialfunctionmodules areshown in the specificationstables on the following pages.
The maximum permissible currents on the5 V DCbusareshownin the table below.
The residual currents for the 24 V DCservice voltage at different input/outputconfigurations areshown in the tableson the right.
Special function modules have to be sup-plied externally, if the residual current forthe service voltage is not satisfying.
A maximum of 256I/Osis possible.
Calculation of the Power Consumption
Module No.24 V DC calculation 5 V DC calculation
Current/ module Calculation Current/ module Totalcurrent
-170 mA !!! 290 190 mA
100mA(OK!)
The tables below and on the right showdifferent examples for sample powercalculation fora PLC system.
The current values for the special functionmodules can be found in the specificationson the following pages.
Comparison with the current value tablesshow that the calculated figures forthe5 V bus lie within the allowable ranges.
In the example below allunits can besupplied sufficiently with the internal24 V power supply.
Sample Calculations
Module No.Number of I/Os 24 V DC calculation 5 V DC calculation
X Y X/Y Total
Total current
Current / module Total current
+95 mA (OK!) +260 mA (OK!)
64+64+24=152!(
-
7/25/2019 Plc Fx Family
8/908 MITSUBISHI ELECTRIC
The ALPHA 2 Series
MITSUBISHI
POWER
24VDC
AL2-24MR-D
ESC
OK
1(A)7
+ -6
15
511 12 13 14
410
39
2(B)8
DCINPUT
Integratedcalender/real-time functionwithup to1200switch ONor OFFcommandsin oneprogram
Upto 15 inputs can be used as digitalinputsandup to8 for analog inputs(controllerswith 24 V DC supply).
Direct programming via8 functionkeys on thefrontcontrolpanelwithout any additional program-ming device
The program is stored in a maintenance-free EEPROMwith a memorycapacityof5000 bytes.
A backupbattery is notrequired.
Flexiblemounting through integrated DINrail adapter andscrewfixing
The communication with a com-puter and with external periphe-rals is supportedby thetwointegratedserialinterfaces.
The analog inputs (0 10 V , 9 bitsresolution) canbe used very easilydueto theintegrated gain function andaSchmitt-trigger.
Password protectioncan be activated.
Large LC display for programming,entering, and editing plain text,valuesand bargraphs
The units can be expandedto additional inputs/outputs
with extensionmodules tobe mounted directly into thecontroller
POWER24VDC
AL2-24MR-D
ESC
OK
1(A)7
+ -6
15
511 12 13 1
4
410
39
2(B)8
DCINPUT
MITSUBISHI
Protective cover
Adapter for
DIN railmounting
Mounting hole
SlotforEEPROM cassette
or connectorforprogramming cable
Power supplyterminals
Terminals fordigital outputs
Operating keys (8 pcs.)
Housing cover(placeholder) fortheextension modules
Connector for PC,GSM, modem and
otherautomationcomponents
LCD display(4 linesx 12characters) Connectionforextensions
Description of the Unit Components
Terminals fordigital/analog inputs
ALPHA SYSTEMOUTLINE ///
-
7/25/2019 Plc Fx Family
9/909MITSUBISHI ELECTRIC
ALPHA
SERIES
Specifications ALPHA 2
MITSUBISHI
POWER
24VDC
AL2-24MR-D
ESC
OK
1(A)7
+ -6
15
511 12 13 1
4
410
39
2(B)8
DCINPUT
e.g.AL2-24M-
Base Units with 10 24 I/Os
Specifications AL2-10MR-A AL2-10MR-D AL2-14MR-A AL2-14MR-D AL2-24MR-A AL2-24MR-D
Electricalspecifications
Order information
Accessories
ALPHA 2 BaseUnits
The ALPHA 2 controllers offer simple reliable control for a rangeof automation applications including lighting,air conditioning,security systems,and temperature and water control.
Special features:
Transistor and relay output options
Analog input/output
High Speed counters up to 1 kHz
GSM function for communication with mobile phones
Language support for 8 different languages
Display unit for messages and function block data
/// ALPHA BASEUNITS
-
7/25/2019 Plc Fx Family
10/9010 MITSUBISHI ELECTRIC
Environmental Specifications
Programming Specifications
General specifications Alpha 2 series
System specifications Alpha 2 series
Output specifications All modules
Electrical Specifications
Power supplyspecifications
DC powered modules(AL2- MR-D)
AC powered modules(AL2- MR-A)
Digital Inputs
Analog Inputs
GENERAL SPECIFICATIONS ///
-
7/25/2019 Plc Fx Family
11/9011MITSUBISHI ELECTRIC
ALPHA
SERIES
Digital ExtensionModules
There are4 differentextension modulesavailablefor theALPHA 2,which allow the controllerto be extended through additional inputs or outputs.The modules areinserted directlyinto theALPHA 2 and thereforedo not take up any additionalspace.
The AL2-4EX has the additional feature that 2 inputs may be used as high-speed counterswith a counting frequencyof 1 kHz.
All modules feature photocoupler insulation forall I/Os.
Note: Thedigital extensionmodulescannot be used withthe AL2-10MR series.
MITSUBISHI
EO1
EO3 EO4
EO2
4EYR
RELAYOUTPUT
Digital extension modules specifications AL2-4EX-A2 AL2-4EX AL2-4EYR AL2-4EYT
Inputs
Outputs
Electricalspecifications
Mechanicalspecifications
Order information
POWER24VDC
MITSUBISHI
POWER
V1+
SLD
+
K-typeThermocouple -50~450C
AL2-2TC-ADP
L1+
-
L1-
V2+
L2-
V1-
L2+
V2-
SLD
OUTPUTCH1 CH2
0~10V
450C 450C
CH1 CH2
-50C -50CLine Lin
e
CH1 CH2
POWER24VDC
MITSUBISHI
POWER
V1+
I1-
+
PT100-50~200CAL2-2PT-ADP
L1+
-
L1-
V2+
L2-
V1-
L2+
V2-
I2-
OUTPUTCH1 CH2
0~10V
200C 200C
CH1 CH2
-50C -50CLine Li
ne
CH1 CH2
MITSUBISHI
2DA
+ V1+ I1+ VI1--
V2+ I2+ VI2-
POWER24VDC
ANALOGOUTPUT
ANALOGOUTPUT
Analog ExtensionModules
The analog extension modules significantly increase the range of applications for theALPHA 2. With these modules it is possible to output voltageor current signals ortomeasure temperatures.
Three different analog extension modules are available:
The AL2-2DA offers two additional analog outputs for the ALPHA 2 and converts adigital input value into a voltage or a current. This module is inserted directly into theALPHA 2.Note: the AL2-2DA cannot be used with the AL2-10MR series.
The AL2-2PT-ADP connects an external PT100 sensor to convert temperature readingsinto analog signals (0 10 V).
The AL2-2TC-ADP connects thermocouple sensors (K type) to convert temperaturereadings into analog signals (0 10 V).
Analog extension modules specifications AL2-2DA AL2-2PT-ADP AL2-2TC-ADP
Analog inputs
Analog outputs
Electricalspecifications
Mechanicalspecifications
Order information
Note: EI1and EI2of theAL2-4EX canbe usedas high-speedcounter inputs.In each case theresponsetime forthe high-speedcounter inputswill be0.5 ms or less.
/// EXTENSIONMODULES
-
7/25/2019 Plc Fx Family
12/9012 MITSUBISHI ELECTRIC
AS InterfaceModuleAL2-ASI-BD
The Actuator Sensor Interface module AL2-ASI-BD in combination with an ALPHA 2 con-troller facilitatesthe data communications via an AS interface system. The AL2-ASI-BD isattached to an ALPHA 2 series module andforms a slaveunit.Up to 4 inputsand 4 outputscan be exchangedwith the ASI master.
The addresses of the slave devices in the ASI interface are assigned either automatically
via the master in thenetwork or via a programming device (software).The maximum communication distance is 100 m without a repeater.If 2 repeaters areused,thedistanceis extendedtoup to300 m.
For the AS interface a separate power supply is required. The communication signal issuperimposed on the power supply of the AS interface bus.
Note: TheAL2-ASI-BD cannotbe used withthe AL2-10MRseries.
Specifications AL2-ASI-BD
Order information
ASI+ASI-
AL2-EEPROM
MADEINJAPAN
Memory CassetteAL2-EEPROM-2
Withthe AL2-EEPROM-2 memory cassettes,a newprogram can be transferred to theALPHA 2 controllers internal system memory from the cassette,or the program of theinternal system memory can be saved to the cassette.
If the memory cassette is used,a certain program can be run temporarily by simplyplugging the external memory module onto the ALPHA 2.
After removing the memory cassette,the former program in theinternal memory
becomes active again.The memory cassette AL2-EEPROM-2 is not a memory expansion device,but a mediumfor data exchange.
Specifications AL2-EEPROM-2
Order information
AL2-GSM-CAB
LOT.24
MITSUBISHI ELECTR
IC
InterfaceCableAL-232CABThe AL-232CAB is an RS232C interface cable. It connects the ALPHA 2 controller to apersonal computer runningthe programming software forthe ALPHA 2 controller.
The cable ensures a galvanic isolation between the ALPHA 2 controller and the personalcomputer.The cable AL-232CAB can not be used forany other connection.
GSMCableAL2-GSM-CAB
The GSM AL2-GSM-CAB is an RS232C interface cable and it is used to connect the ALPHA 2controller to a normal or GSM modem,a personal computer or other serial devices.It cantransfer SMS data to a GSM modem foronward transmission to mobile telephones ore-mail addresses. It alsopermits remotemonitoringand remote maintenance.
Note: Theabovecables cannotbe usedwiththe AL2-10MR series.
Specifications AL-232CAB AL2-GSM-CAB
Order informationAL2-GSM-CAB
AL-232CAB
EXTENSIONMODULES ANDACCESSORIES ///
-
7/25/2019 Plc Fx Family
13/9013MITSUBISHI ELECTRIC
FXBASEUNITS
0 1 2 3
4 5 6 7
0 1 2 3
4 5
IN
OUT
POWER
FX -14MR1S
RUN
ERROR
X7X5X3X1S/S X6X4X2X0NL100-240
VAC
14MR-ES/UL
Y4Y2Y1Y0
COM0COM1COM2 Y3 Y5
24V
0V
MITSUBISHI
Connection of thepower supply Terminals for
digital inputs
LEDs forindicatingtheoperating status
Adapter interface
Protective cover
RUN/STOP switch
Terminal cover
Service voltagesource
2 analog potentiometers
LEDs forindicatingthe input status
Fixing hole
Slot foradapter
Connection forprogramming units
Housing cover
LEDs forindicatingthe output status
Terminals fordigital outputs
Description of the Unit Components
The MELSEC FX1SSeries
Squarepulse output(thisapplies onlyto transistor units.)
Two integratedhigh speedpulseoutputs forfrequencies up to100 kHz for outputtingpulsesignals and controlling steppingmotors
High-speed inputs forfast countingtasks with counting frequencies ofupto60kHzand interrupt process-ingcapabilities
All units feature twoanalogpotentiometers for setpointvalue entry andan integratedRUN/STOP switch.
Your PLC programs arestored in a main-tenance-freeEEPROMusermemorywith a capacity of 2,000 program steps,so there is no needfor a backup batteryto protect against power failures.
Flexible installationwith theintegrated DIN rail adapterandscrew fastening holes formount-ing on flatsurfaces
IntegratedserialRS422interface fordirect commu-nication with computers
The internalservice powersupplyunit for24VDChasa capacityof 400mA.
Note:service power supply is only avail-ablefor AC PowerSupply types.
Passwordaccessprotectionfacility for effective protectionof your intellectual property.
Integration ofinterface,exten-sion,and functions adaptersfordirect installationin the baseunit
MITSU
BISH
I
0123
4567
0123
45
POWER
RUN
ERRO
R
FX1S
-14MR
IN
OUT
M
L
S
Integratedreal-timeclockwith year, month,day andtime
/// BASEUNITS FX1S SERIES
-
7/25/2019 Plc Fx Family
14/9014 MITSUBISHI ELECTRIC
Specifications FX1S-10MR-DSFX1S-10MR-ES/UL
FX1S-10MT-DSS
FX1S-14MR-DS
FX1S-14MR-ES/UL
FX1S-14MT-DSS
Order information
Specifications FX1S-20MR-DSFX1S-20MR-ES/UL
FX1S-20MT-DSS
FX1S-30MR-DS
FX1S-30MR-ES/UL
FX1S-30MT-DSS
Order information
0 1 2 3
4 5 6 7
0 1 2 3
4 5
IN
OUT
POWER
FX -14MR1S
RUN
ERROR
MITSUBISHI
X7X5X3X1S/S X6X4X2X0NL100-240
VAC
14MR
-ES/ULY4Y2Y1Y0
COM0COM1COM2 Y3 Y5
24V
0V
BaseUnits FX1S
The FX1S series baseunits areavailable with 10 to 30 input/outputpoints.
It is possibleto choose between relay and transistor output type.Note: Versionswith ULcertification areavailableon request.
Special Features:
Integrated power supply (AC or DC powered)
Maintenance-free EEPROM memory
Ample memory capacity (2000 steps) and device ranges
High-speed operations
Incorporated positioning control
Integrated real-time clock
System upgrades by exchangeable interface and I/O adapterboards for direct fitting into the base unit
LEDs for indicating the input and output status
Standard programming unit interface
User-friendly programming systems, including IEC 61131.3(EN 61131.3)-compatible programming software, HMIs andhand-held programming units
Base Units FX1S FX1N FX2N FX2NC FX3U
Base Units with 10 14 I/Os
Base Units with 20 30 I/Os
BASEUNITS FX1S SERIES ///
-
7/25/2019 Plc Fx Family
15/9015MITSUBISHI ELECTRIC
FXBASEUNITS
Output specifications RelaymodulesTransistormodules
Power supplyspecifications
DC powered modules(FX1S- M -DS/-DSS)
AC powered modules(FX1S- M -ES/UL)
General specifications Data
Programming Specifications
System specifications FX1S
Program data
Operands
Environmental Specifications
Electrical Specifications
Base Units FX1S FX1N FX2N FX2NC FX3U
/// BASEUNITS FX1S SERIES
-
7/25/2019 Plc Fx Family
16/9016 MITSUBISHI ELECTRIC
The MELSEC FX1NSeries
The base units can be expandedforup to 128 inputs/outputs withdifferentextensionunits.
High-speed inputs for fastcounting tasks with countingfrequencies of up to 60 kHz andinterruptprocessing
capabilities
IntegratedRUN/STOP switch and twoanalogpotentiometers for setpoint
value entry.
The base units have integrated,maintenance-free EEPROMusermemoryforupto8,000PLCprogramstepswith a
backup battery to protectmemory contents against powerfailures. You can also configurepassword protection to preventunauthorized access to yourprograms.
Squarepulse output(This only applies fortransistor units.)
Two integratedhigh-speedpulseoutputs forfrequencies up to100 kHz foroutputting pulsesignals and controlling steppingmotors
ExternalEEPROMmemorycassettes forPLC program storage
Integration ofinterface,extension,and functionsadapters for direct installa-tion in the base unit
01
23
45
67
1011
1213
1415
01
23
45
67
1011
POWER
RUN
ERRO
R
FX1N
-24MR
IN
OUT
MITSU
BISH
I
M
L
S
Integrated real-timeclockwith year, month,day and time
Protective cover
Terminal cover
Terminals fordigital outputs
Terminals forservice voltagesource
Connection forprogramming units
Terminal cover
0 1 2 3
4 5 6 7
8 9 1011
12131415
0 1 2 3
4 5 6 7
1011
IN
OUT
POWER
FX - 24MR1N
RUN
ERROR
100-240
VAC
X7 X11 X13 X15
X5X3X1S/S X6 X10 X12 X14
X4X2X0NL
24MR-ES/UL
Y10Y6Y5Y3
COM3 Y4 COM4 Y7 Y11
COM2COM1COM024+
Y2Y1Y00V
MITSUBISHI
RUN/STOP switch Extension bus
Connection of thepower supply
LEDs for indicating theoperating status
LEDs for indicatingthe input status
Protective cover
Lid
Slotfor memory cassettes,displaysand ADPs.
2 analog potentiometers
Terminals fordigital inputs
LEDs for indicatingthe output status
Housing cover
Fixinghole
Description of the Unit Components
BASEUNITS FX1N SERIES ///
-
7/25/2019 Plc Fx Family
17/9017MITSUBISHI ELECTRIC
FXBASEUNITS
Base Units FX1S FX1N FX2N FX2NC FX3U
BaseUnits FX1N
The FX1N series baseunits areavailable with 14 to 60 input/outputpoints.
It is possibleto choose between relay and transistor output type.Note: Versionswith ULcertification areavailableon request.
Special Features:
Integrated serial interface for communication betweenPersonal computers and HMI
Standard programming unit interface
LEDs for indicating the input and output status
Detachable terminal blocks for units with 14,24, 40, and 60 I/Os.
Slot for memory cassettes
All DC models with variable voltage from 12 up to 24 V
Integrated real-time clock
Exchangeable interface and I/O adapter boards for direct fitting
into the base unit
MITSUBISHI
0 1 2 3
4 5 6 7
8 9 1 011
12131415
0 1 2 3
4 5 6 7
1011
IN
OUT
POWER
FX -24MR1N
RUN
ERROR
100-240
VAC
X7 X11 X13 X15
X5X3X1S/S X6 X10 X12 X14
X4X2X0NL
24MR
-ES/ULY10Y6Y5Y3
COM3 Y4 COM4 Y7 Y
11COM2COM1COM024+
Y2Y1Y00V
Specifications FX1N-14MR-DSFX1N-14MR-ES/UL
FX1N-14MT-DSS
FX1N-24MR-DS
FX1N-24MR-ES/UL
FX1N-24MT-DSS
Order information
Base Units with 14 24 I/Os
Base Units with 40 60 I/Os
Specifications FX1N-40MR-DS FX1N-40MR-ES/UL FX1N-40MT-DSS FX1N-60MR-DS FX1N-60MR-ES/UL FX1N-60MT-DSS
Order information
/// BASEUNITS FX1N SERIES
-
7/25/2019 Plc Fx Family
18/9018 MITSUBISHI ELECTRIC
Base Units FX1S FX1N FX2N FX2NC FX3U
Environmental Specifications
General specifications Data
System specifications FX1N
Program data
System specifications FX1N
Operands
Programming Specifications
Output specifications RelaymodulesTransistormodules
Power supplyspecifications
DC poweredmodules(FX1N- M -DS/-DSS)
AC powered modules(FX1N- M -ES/UL)
Electrical Specifications
BASEUNITS FX1N SERIES ///
-
7/25/2019 Plc Fx Family
19/9019MITSUBISHI ELECTRIC
FXBASEUNITS
POWE
R
RUN
BATT
.V
PROG
E
CPU
E
01
23
45
67
1011
1213
1415
1617
IN
01
23
45
67
1011
1213
1415
1617
OUT
C
O
M
X
X
2
X
6
X
2
X
4
X
6
X
4
X
C
O
M
O
Y
2
C
O
M
2
4
Y
6
C
O
M
3
Y
2
C
O
M
4
4
Y
6
Y
Y
3
Y
5
Y
7
Y
Y
3
Y
5
Y
7
MITS
UBISHI
The base units can be expandedto provideconfigurations with upto 256inputs andoutputs withmodularand compactextensionunits.
Integratedhigh-speed counter inputs forprocessing fast input signals. For example,you can configuretwo 60 kHz countersand four 10 kHz counters.
Interrupt processing is alsohandledvia the inputs.
An integratedRUN/STOPswitchis available.
Two integratedpulseoutputs for frequenciesfrom 2 to 20,000 Hz forcontrolling steppingmotors and outputtingpulse-widthmodu-latedsignals.
RAM/EEPROMmemory forup to16,000PLCprogramstepsgivesyou plenty of reserve,even forbig,complex applications.
Integratedserial interfacefor direct communication withcomputers
Integratedreal-timeclockwith year, month,day andtime
Add-in functionboardscan be installedin the PLC toprovidea secondRS485 /RS422 / RS232communicationsinterface for programming ornetwork configurations.
An add-in function board with 8 analogpotentiometers is also available.
The MELSEC FX2NSeries
Fixinghole
Back-upbattery
Detachable terminal stripfordigital inputs
Detachableterminal stripfordigitaloutputs
Connection for extensions
LEDs forindicatingtheoutput status
Protective cover fortheextensionbus
Housingcover
Protectivecover
Extensionconnectorforfunctionboards
Connection forprogrammingunits
LEDs forindicating theoperating status
RUN/STOP switch
LEDs forindicatingthe input status
Slot formemorycassettes
Connectionof thepowersupply
Description of the Unit Components
Terminalcover
/// BASEUNITS FX2N SERIES
-
7/25/2019 Plc Fx Family
20/9020 MITSUBISHI ELECTRIC
BaseUnits FX2N
The FX2N series base units are available with 16,32,48,64,80 or128 input/output points.
It is possibleto choose between relay and transistor output type.Triac output types for 110 V AC for sink/source are also available.
Note:Additionalspecial versions areavailable on request.
Special Features:
Exchangeable interface modules for direct mounting intoa base unit
Standard programming unit interface
LEDs for indicating the input and output status
Detachable terminal blocks (except for 16 I/O base units)
Slot for memory cassettes for up to 16 k steps PLC program
Integrated real-time clock
Specifications FX2N-16MR-DSFX2N-16MR-ES/UL
FX2N-16MT-DSS
FX2N-16MT-ESS/UL
Order information
Base Units FX1S FX1N FX2N FX2NC FX3U
Base Units with 16 I/Os
Base Units with 32 I/Os
Specifications FX2N-32MR-DSFX2N-32MR-ES/UL
FX2N-32MT-DSS
FX2N-32MT-ESS/UL
Order information
BASEUNITS FX2N SERIES ///
-
7/25/2019 Plc Fx Family
21/9021MITSUBISHI ELECTRIC
FXBASEUNITS
Specifications FX2N-48MR-DSFX2N-48MR-ES/UL
FX2N-48MT-ESS/UL
FX2N-48MT-DSS
Order information
Base Units with 48 I/Os
Base Units with 64 I/Os
Specifications FX2N-64MR-DSFX2N-64MR-ES/UL
FX2N-64MT-ESS/UL
FX2N-64MT-DSS
Order information
Specifications FX2N-80MR-DSFX2N-80MR-ES/UL
FX2N-80MT-DSS
FX2N-80MT-ESS/UL
FX2N-128MR-ES/UL
FX2N-128MT-ESS/UL
Order information
Base Units with 80 128 I/Os
/// BASEUNITS FX2N SERIES
-
7/25/2019 Plc Fx Family
22/9022 MITSUBISHI ELECTRIC
Base Units FX1S FX1N FX2N FX2NC FX3U
Environmental Specifications
General specifications Data
System specifications FX2N
Program data
System specifications FX2N
Operands
Programming Specifications
Output specifications RelaymodulesTransistormodules
Power supplyspecifications
DC powered modules(FX2N- M -DS/-DSS)
AC powered modules(FX2N- M -ES/UL)
Electrical Specifications
BASEUNITS FX2N SERIES ///
-
7/25/2019 Plc Fx Family
23/9023MITSUBISHI ELECTRIC
FXBASEUNITS
The MELSEC FX2NCSeries
Terminal stripfor digital outputs
Terminal stripfor digital inputs
Slotfor memoryboards
Memory board(option)
Cover
POWER
RUN
BATT
ERROR
X0
1
2
3
X4
5
6
7
Y0
1
2
3
Y4
5
6
7
RUN
STOP
MITSUBISHI
FX -16MR-T-DS2NC
M
L
S
COM
X7
X6
X5
X4
COM
X3
X2
X1
X0
Y4
COM1
Y3
Y2
Y1
Y0
RUN/STOP switch Extension bus (lateral)
Back-up battery fitting
LEDs forindicatingthe output status
Protective cover forextension bus
Protective cover
LEDs for indicating theoperating status
Interface forCNV adapter
Back-up battery
LEDs forindicatingthe input status
Connector forterminal strips
Description of the Unit Components
COM
X7
X6
X5
X4
COM
X3X2
X1X0
Y01
23
Y45
67
MITSUB
ISHI
M
L
S
COM
X7X6
X5X4
CO
M
X3
X2
X1X0
FX-16MR-T-DS
2NC
POWER
RUN
STOP
ERRO
R
X01
23
X45
67
RUN
STOP
The baseunits can be expandedto provide configurations withup to 256inputs andoutputswithmodularand compactexpansionunits.
Integrated high-speed counter inputs forprocessing fast input signals. For example,you can configure two60 kHz countersand four 10 kHz counters.
Interrupt processing is alsohandledvia the inputs.
RAM/EEPROM memory forup to16,000PLCprogramstepsgivesyou plenty of reserve, even forbig,complex applications.
Integrated serial interfacefordirect communicationwith computers
An integratedRUN/STOPswitchis available.
Two integratedpulseoutputs for frequen-cies from 2 to 20,000Hz for controlling step-pingmotors and outputtingpulse-widthmodulatedsignals (only fortransistor units)
External EEPROMmemoryboards forPLC programstorage
Interface adapter connectionfor secondcommunicationsinterface RS485/ RS232
/// BASEUNITS FX2NC SERIES
-
7/25/2019 Plc Fx Family
24/9024 MITSUBISHI ELECTRIC
Specifications FX2NC-16MT-DSSFX2NC-16MR-T-DS
FX2NC-32MT-DSS
FX2NC-64MT-DSS
FX2NC-96MT-DSS
Order information
BaseUnits FX2NC
The base units of the FX2NC are available in versions with 16,32, 64or 96 I/Os. Nineoutput types are available:eight different transis-tor output types and one relay output type.
Note: Versionswith ULcertification areavailableon request.
Special Features:
Very compact dimensions
Standard programming unit interface
LEDs for indicating the input and output status
Removable terminal blocks (screw terminals for the relay out-put type) or ribbon cable connectors (for the transistor outputtypes) for system cabling
Slot for memory boards for up to 16 k steps PLC program
Adapter modules and system cabling sets available for unitswith ribbon cable connectors (see accessories)
POWER
RUN
BATT
ERROR
X0
1
2
3
X4
5
6
7
Y0
1
2
3
Y4
5
6
7
RUN
STOP
MITSUBISHI
FX -16MR-T-DS2NC
M
L
S
COM
X7
X6
X5
X4
COM
X3
X2
X1
X0
POWER
RUN
BATT
ERROR
X0
1
2
3
X4
5
6
7
Y0
1
2
3
Y4
5
6
7
RUN
STOP
MITSUBISHI
FX -16MT2NC
Base Units FX1S FX1N FX2N FX2NC FX3U
Base Units with 16 96 I/Os
BASEUNITS FX2NC SERIES ///
-
7/25/2019 Plc Fx Family
25/9025MITSUBISHI ELECTRIC
FXBASEUNITS
Environmental Specifications
General specifications Data
System specifications FX2NC
Program data
System specifications FX2NC
Operands
Programming Specifications
Base Units FX1S FX1N FX2N FX2NC FX3U
Output specifications RelaymodulesTransistormodules
Power supplyspecifications DC powered modules
Electrical Specifications
/// BASEUNITS FX2NC SERIES
-
7/25/2019 Plc Fx Family
26/9026 MITSUBISHI ELECTRIC
The MELSEC FX3USeries
Description of the Unit Components
The base units can be expandedto provideconfigurations with upto 384inputs andoutputs withcompactextensionunits(total of 384only by using mainunitI/Os,extension unit I/Os andremote I/Os).
Integratedhigh-speedcounter inputs for processingfast input signals. For example,you can configuresix100kHz counters and two 10 kHz counters.
Interrupt processing is also handled via the inputs.
An integratedRUN/STOPswitch is available.
Three integratedpulseoutputs for frequenciesupto100kHzwithdecelerationandaccelerationramps forcontrolling stepping motors and output-ting pulse-widthmodulatedsignals.
RAM/EEPROM memory for up to64,000PLCprogram stepsgivesyou plenty of reserve, even forbig,complex applications.
Integratedserial interfacefor direct communication withcomputers
Integratedreal-timeclockwith year, month,days and time
Add-in functionboardscan be installedin the PLC toprovidea secondRS485 /RS422/ RS232/USBcommunicationsinterface for programming ornetwork configurations.
Battery cover
Installationplace forFX3U-7DM
Periphal deviceconnectingconnector
LEDs for indicatingthe output status
Expansionboarddummy cover
LEDs for indicatingtheoperating status
RUN/STOP switch
Extension device connect-ing connector cover
LEDs for indicatingthe input status
Top coverwith Model name(used,if FX3U-7DMis not installed)
Battery
Protective cover
Output terminals
Terminal block cover
Protective cover
Input terminals
Terminal block cover
BASEUNITS FX3U SERIES ///
-
7/25/2019 Plc Fx Family
27/9027MITSUBISHI ELECTRIC
FXBASEUNITS
BaseUnits FX3U
The FX3U series base unitsare available with 16,32,48, 64 or80 input/output points.
All base units providethe relay output type.
Special Features:
Exchangeable interface modules for direct mounting intoa base unit
Standard programming unit interface
LEDs for indicating the input and output status
Slot for memory cassettes for up to 64 k steps PLC program
Integrated real-time clock
Base Units FX1S FX1N FX2N FX2NC FX3U
Base Units with 16 80 I/Os
Specifications FX3U-16MR/ESFX3U-32MR/ES
FX3U-48MR/ES
FX3U-64MR/ES
FX3U-80MR/ES
Order information
/// BASEUNITS FX3U SERIES
-
7/25/2019 Plc Fx Family
28/9028 MITSUBISHI ELECTRIC
Base Units FX1S FX1N FX2N FX2NC FX3U
Environmental Specifications
Programming Specifications
Electrical Specifications
General specifications Data
Output specifications Relay modules
Power supplyspecifications
AC powered modules(FX3U- MR/ES)
System specifications FX3U
Program data
System specifications FX3U
Operands
BASEUNITS FX3U SERIES ///
-
7/25/2019 Plc Fx Family
29/9029MITSUBISHI ELECTRIC
EXTENSIONMOD
ULES
Powered Compact Extension Units FX1S FX1N FX2N FX2NC FX3U
Extension Units FX0N
The FX0N series extension units areavailable with 40 input/output points.
It is possible to choose between relay and transistoroutputtype.
SpecialFeatures:
LEDs for indicating the input and output status
MELSEC FX1Nseries compatible
Integrated service power supply with up to 200 mA capacity
Specifications FX0N-40ER-ES/ULFX0N-40ER-DS
FX0N-40ET-DSS
Electricaldata
Inputs
Outputs
Mechanicaldata
Order information
/// COMPACT EXTENSIONUNITS
-
7/25/2019 Plc Fx Family
30/9030 MITSUBISHI ELECTRIC
Powered Compact Extension Units FX1S FX1N FX2N FX2NC FX3U
Extension Units FX2N
The FX2N series extension units are available with 32 or48 input/output points.
It is possible to choose between relay and transistoroutputtype.
SpecialFeatures:
LEDs for indicating the input and output status
MELSEC FX1N/FX2Nand FX3Useries compatible
Detachable terminal blocks
Integrated service power supply with 250 mA or 460 mA
Specifications FX2N-32ER-ES/ULFX2N-32ET-ESS/UL
FX2N-48ER-DS
FX2N-48ER-ES/UL
FX2N-48ET-DSS
FX2N-48ET-ESS/UL
Electricaldata
Inputs
Outputs
Mechanicaldata
Order information
COMPACT EXTENSIONUNITS ///
-
7/25/2019 Plc Fx Family
31/9031MITSUBISHI ELECTRIC
EXTENSIONMOD
ULES
Unpowered Modular Extension Blocks FX1S FX1N FX2N FX2NC FX3U
Extension Blocks FX2N
The FX2N series modularextensionblocks are available with8 or 16 input/output points.
It is possible to choose between relay and transistoroutputtype.Note: When attaching an extension block to a FX2NC base unit,the interfaceadapterFX2N-CNV-IF is required.
SpecialFeatures:
LEDs for indicating the input and output status
MELSEC FX1N/FX2N/FX2NCand FX3Useries compatible
Very compact dimensions
Vertically terminal blocks with a cable guide to the upper orlower side
Specifications FX2N-8ER-ES/ULFX2N-8EX-ES/UL
FX2N-8EYR-ES/UL
FX2N-8EYT-ESS/UL
FX2N-16EX-ES/UL
FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
Electricaldata
Inputs
Outputs
Mechanicaldata
Order information
IN
2
OUT
OUT
FX2N-8EX-ES
FX2N-16EYR-ES/UL
///MODULAR EXTENSIONUNITS
-
7/25/2019 Plc Fx Family
32/9032 MITSUBISHI ELECTRIC
Unpowered Modular Extension Blocks FX1S FX1N FX2N FX2NC FX3U
Modular Extension Blocks FX2NC
The FX2NC series extension blocks areavailablewith 16 or32 input/output points.
For modules with16 outputs it is possible to choose betweenrelay and transistor output type.
SpecialFeatures:
Very compact dimensions
LEDs for indicating the input and output status
Removable terminal blocks for FX2NC-16EYR-T-DS andFX2NC-16EX-T-DS
Adapter modules and system cabling sets available for unitswith ribbon cable connectors (transistor output types)
POWER
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
FX -32EX
-DS
2NC
Specifications FX2NC-16EX-T-DSFX2NC-16EYR-T-DS
FX2NC-16EX-DS
FX2NC-16EYT-DSS
FX2NC-32EX-DS
FX2NC-32EYT-DSS
Electricaldata
Inputs
Outputs
Mechanicaldata
Order information
PW
Y0
1
2
3
Y4
5
6
7
Y0
1
2
3
Y4
5
6
7
FX -16EYR-T-DS2NC
FX2NC-32EX-DS
FX2NC-16EYR-T-DS
MODULAR EXTENSIONUNITS ///
-
7/25/2019 Plc Fx Family
33/9033MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
Specifications FX2N-2DA FX2N-4DA FX2NC-4DA
Order information
Analog Output Modules FX1S FX1N FX2N FX2NC FX3U
FX2N-2DA, FX2N-4DA, FX2NC-4DA
The analog output modules provide the user with 2 to 4 analog outputs. The modulesconvertdigital values from the FX1N/FX2N/FX2NC/FX3U controller to the analog signalsrequired by the process.The module can output both current and voltage signals.
Note:TheFX2NC-4DAmayonlybeusedincombinationwithaFX2NCseriesbase unit.WhenattachingaFX2N-2DAor FX2N-4DA to a FX2NC base unit,the interface adapterFX2N-CNV-IFis required.
Analog Input Modules FX1S FX1N FX2N FX2NC FX3U
FX2N-2AD, FX2N-4AD,FX2NC-4AD, FX2N-8AD
The analog input modules provide the user with 2 to 8 analog inputs.The module converts analog process signals into digital values which are furtherprocessed by the MELSEC FX1N/FX2N/FX2NC/FX3U controller.
The actual values or mean values over several measurements may be output.
Note:TheFX2NC-4ADmayonlybeusedincombinationwithaFX2NCseriesbase unit.WhenattachingaFX2N-2AD,FX2N-4AD,or FX2N-8AD to a FX2NCbase unit,the interface adapterFX2N-CNV-IF is required.
Specifications FX2N-2AD FX2N-4AD FX2NC-4AD FX2N-8AD
Order information
POWER
2N -2ADFX
MITSUBISHI
FX -8AD2N
POWER
24V
/// ANALOGMODULES
-
7/25/2019 Plc Fx Family
34/9034 MITSUBISHI ELECTRIC
Combined Analog I/O Modules FX1S FX1N FX2N FX2NC FX3U
FX0N-3A, FX2N-5A
The analog input/output modules are available in two different models. They providethe user with 2 or 4 analog inputs and 1 analog output. They serve for conversion ofanalog process signals into digital values, and vice versa.
As of the FX2N-5A module the analog inputs can be selected between current or volt-age input signals.
Note:TheFX2N-5A may not beusedincombinationwitha FX1Nseriesbase unit.When attachingoneofthese analogmodules to a FX2NC base unit,the interface adapterFX2N-CNV-IFis required.
Specifications FX0N-3A FX2N-5A
Order information
Analog Temperature Input Modules
FX1S
FX1N
FX2N
FX2NC
FX3U
FX2N-4AD-TC, FX2N-4AD-PT, FX2N-2LC
The analog input module for thermocouples FX2N-4AD-TC is used for processing tem-peratures. It has 4 independent inputs for detecting signals from thermocouples oftypes J and K. The type of thermocouple can be chosen independently for each point.
The analog input module for Pt100 inputs FX2N-4AD-PT permits the connection of fourPt100 sensors to the FX2N/FX2NC/FX3Useries controller.
The temperature control module FX2N-2LC is equipped with two temperature inputpoints and two transistor (open collector) output points. It is used to read temperaturesignals from thermocouples and Pt100 sensors, and performs PID output control
Note:TheFX2N-2LC maynot be used in combination witha FX1Nseriesbase unit.Whenattaching oneofthese modules to a FX2NC base unit,the interface adapterFX2N-CNV-IFis required.
Specifications FX2N-4AD-TC FX2N-4AD-PT FX2N-2LC
Order information
FX -4AD-TC2N
A/D
FX -5A2N
24 V
AD/DA
FX0N-3A
FX2N-5A
ANALOGMODULES ///
-
7/25/2019 Plc Fx Family
35/9035MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
FX3U-4AD-TC-ADP, FX3U-4AD-PT-ADP
The analog input adapter for thermocouples FX3U-4AD-TC-ADP is used for processingtemperatures. It has 4 independent inputs for detecting signals from thermocouples oftypes J and K.
The analog input adapter module for Pt100 inputs FX3U-4AD-PT-ADP permits the con-nection of four Pt100 sensors to the FX3Useries controller.
Note: Theseadapters canonlybe usedwiththe FX3U andthey require a functionextensionboard.
Specifications FX3U-4AD-TC-ADP FX3U-4AD-PT-ADP
Order information
Analog Temperature Input Adapters FX1S FX1N FX2N FX2NC FX3U
24+
24-
L4-
J-type
L1+
L1-
L2+
L2-
L3+
L3-
L4+
POWER
FX3U-4AD-TC-ADP
24+
24-
L4-
J-type
L1+
L1-
L2+
L2-
L3+
L3-
L4+
POWER
FX3U-4AD-TC-ADP
Analog I/O Adapters FX1S FX1N FX2N FX2NC FX3U
FX3U-4AD-ADP, FX3U-4DA-ADP
The FX3U-4AD-ADP adapter module for analog input is a special function adapter toadd four analog input points to the FX3UPLC system.
The FX3U-4DA-ADP adapter module for analog output is a special function adapter toadd four analog output points to the FX3UPLC system.
Note: Theseadapters canonlybe usedwiththe FX3U andthey require a functionextensionboard.
Specifications FX3U-4AD-ADP FX3U-4DA-ADP
Order information
POWER
FX3U-4DA-ADP
24+
24-
V1
+
COM4
I1+
COM1
V2+
I2+
COM2
V3+
I3+
COM3
V4+
I4+
POWER
FX3U -4AD-ADP
24+
24-
V1+
COM4
I1+
COM1
V2+
I2+
COM2
V3+
I3+
COM3
V4+
I4+
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-4AD-TC-ADP
FX3U-4AD-PT-ADP
/// ANALOGMODULES
-
7/25/2019 Plc Fx Family
36/9036 MITSUBISHI ELECTRIC
High-Speed Counter Modules FX1S FX1N FX2N FX2NC FX3U
FX2N-1HC
In addition to the internal high-speedMELSECFX counters,the high-speedcountermodule FX2N-1HCprovides the user with an external counter. It counts 1- or 2-phasepulses up to a frequency of 50 kHz.Thecounting range covers either 16 or 32 bit.
The two integrated transistor outputs can be switched independently of oneanother bymeans of internal comparisonfunctions.Hence,simple positioningtasks can alsoberealizedeconomically.In addition,the FX2N-1HC can beused as a ring counter.
Note: When attaching themodule toa FX2NCbase unit,the interface adapterFX2N-CNV-IFis required.
FX -1HC2N
Specifications FX2N-1HC
Order information
Specifications FX3U-4HSX-ADP FX3U-2HSY-ADP
Order information
FX3U-4HSX-ADP, FX3U-2HSY-ADP
These adapter modules allow direct processing of positioning application data.The FX3U-4HSX-ADP provides high speed counter input up to 200 kHz while theFX3U-2HSY-ADP delivers 2 channels of pulsetrain outputs up to 200kHz.
SGB
Y5
/7
-
+
Y1
/3
-
+
Y4
/6
-
+
Y0
/2
-
+
Y4/6 Y5/7
Y1/3Y0/2
POWER
FX3U -2HSY-ADP
FP.RP
PLSDIR
SGA
X1/4 X 6/7
X2/5X0/3
POWER
FX3U-2HSX-ADP
SG
SG
X6/7
X2/5
X1/4
X0/3
-
+
-
+
-
+
-
+
High-Speed Counter Adapters FX1S FX1N FX2N FX2NC FX3U
FX3U-4HSX-ADP
FX3U-2HSY-ADP
HIGHSPEED COUNTER ///
-
7/25/2019 Plc Fx Family
37/9037MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
FX2N-1PG-E, FX2N-10PG
The positioning modules FX2N-1PG-E and FX2N-10PG are extremely efficient single-axispositioning modules forcontrolling eitherstep drives or servo drives (by external regula-tor) with a pulse chain.They arevery suitablefor achieving accurate positioningin combi-nation with the MELSEC FX series.The configurationand allocation of the position dataare carried out directly via the PLC program.A very wide range of manual and automatic functions are available to the user.
Note: When attaching oneof themodules to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF isrequired.
Positioning Modules FX1S FX1N FX2N FX2NC FX3U
2N-10PGFX
START
POWER
DOG
ERROR
X0 PGO
X1 FP
A RP
B CLR
Specifications FX2N-1PG-E FX2N-10PG
Order information
/// POSITIONINGMODULES
-
7/25/2019 Plc Fx Family
38/9038 MITSUBISHI ELECTRIC
CC-LinkMasterModuleFX2N-16CCL-M
The CC-Link network enables the controlling and monitoring of decentralized I/O mod-ules at the machine.
The CC-Linkmastermodule FX2N-16CCL-M is a special extension block which assigns anFX series PLC as the master stationof theCC-Link system.
The setting of all modules within the network is handled directly via the master module.
Up to 15 remotestations and remotedevicestations can be connected to the mastersta-tionas decentralized I/O stations.These remotestations can be up to7 I/Omodules andup to 8 intelligent modules.2 master modules can be connected to oneFX1N/FX2N/FX2NC baseunit.
The maximum communications distance is 1200 m without repeater.
Note: When attaching thismodule to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF is required.Refer tothe Mitsubishi Electric Networkcatalogfor I/Oblocksand power supply units.
Specifications FX2N-16CCL-M
Order information
Network Modules for CC-Link FX1S FX1N FX2N FX2NC FX3U
FX -16CCL-M2nCC-LINK
RUNERR.MST
TEST1TEST2
LRUN
LERR.
SWM/SPRM
TIMELINE
SDRD
CC-LinkCommunicationModuleFX2N-32CCL
The communication module FX2N-32CCL enables the user to connectto the CC-Linknetwork with a superior PLC system as master CPU. This gives him access to the networkof all MELSEC PLC systemsand frequency inverters and to additional products from othersuppliers.
Thus the network is expandable via the digital inputs/outputs of the FX modules to amaximum of 256 I/Os.
The buffer memory of the FX2N-32CCL is readand writtenby FROM/TOinstructions.
The connection is to the extension bus on the right side of the controller.
Note: When attaching thismodule to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF is required.Refer to theMitsubishiElectricCC-Link ,CC-Link/LT productcatalog forI/O blocks andpowersupplyunits.
LRUN LERR RDSD
FX -32CCL2N
Specifications FX2N-32CCL
Order information
NETWORKMODULES ///
-
7/25/2019 Plc Fx Family
39/9039MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
AS-InterfaceModule FX2N-32ASI-M
The FX2N-32ASI-M serves as master module forthe connection of the FX1N/FX2N/FX2NCandFX3U PLC to the AS-interfacesystem.Up to 31 slaveunits with up to 4 inputsand 4outputscan be controlled.
Note: When attaching thismodule to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF is required.
Network Module for AS-Interface FX1S FX1N FX2N FX2NC FX3U
FX -32ASI-M2N
CONFIGERR
FROM/TO
PRGENABLE
ASIACTIVE
PRJMODE
ADRESS/ERROR
POWER
UASI
Specifications FX2N-32ASI-M
Order information
/// NETWORKMODULES
-
7/25/2019 Plc Fx Family
40/9040 MITSUBISHI ELECTRIC
Specifications FX3U-ENET
Order information
EthernetCommunicationsModuleFX3U-ENET
The FX3U-ENET communications module provides the FX3U with a direct connection onto an Ethernet network.
Withthe FX3U-ENET installed an FX3UPLC can exchange data quickly and easily with pro-cess visualization systems in addition to supporting fullprogram UP/DOWN load as wellas comprehensive monitoringsupport.The module alsosupports Peer to Peer connectionand MC Protocol. It is easily set-up with the FX Configurator-EN software.
POWER
RUN
C1
INIT.
C2
100M
C3
SD
C4
RD
C5
ERR.
C6
COM.ERR.
C7
C8
10BASE-T/100BASE-TX
FX3U-ENET
Network Module for Ethernet FX1S FX1N FX2N FX2NC FX3U
Specifications FX2NC-ENET-ADP
Order information
EthernetCommunicationsAdapterFX2NC-ENET-ADP
The FX2NC-ENET-ADP communications adapter is an Ethernet interface with 10BASE-Tspecifications for the FX1S, FX1N, FX2N andFX2NC series.
The FX2NC-ENET-ADP enables upload, download,monitorand test sequence of programsvia Ethernet from a personal computer (GX Developer or MX Component and the virtualCOMport driverinstalled).
Note:When connectingthisadapter moduleto a FX1Sor FX1N PLC thecommunications adapterFX1N-CNV-BDis required.When connectingthis adaptermodule to a FX2N PLC thecommunicationsadapterFX2N-CNV-BD is required.
POWER
LINK
ACT
FX -ENET-ADP2NC
SD
RD
Network Module for Ethernet FX1S FX1N FX2N FX2NC FX3U
NETWORKMODULES ///
-
7/25/2019 Plc Fx Family
41/9041MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
Specifications FX3U-64DP-M
Order information
MastermoduleFX3U-64DP-M
The FX3U-64DP-M PROFIBUS/DP master module enables you to integrate a MELSEC FX3UPLC system as a class1 master of a PROFIBUS/DP network.
This interface module provides your FX3U CPU with an intelligent Profibus/DP link for theimplementation of decentralised control tasks.
The FX3U Profibus/DP masterprovides comprehensive data and alarm processingto theProfibus/DP V1 standard.It is easily set up with the GX Configurator-DP software.
Network Module for Profibus/DP FX1S FX1N FX2N FX2NC FX3U
3UFX -64DP-M
ERROR
FROM/TO
TOKEN
RUN
POWER
Specifications FX0N-32NT-DP
Order information
SlaveModuleFX0N-32NT-DP
The FX0N-32NT-DP PROFIBUS/DP slave module enables you to integrate a MELSECFX1N/FX2N/FX2NC orFX3U in an existingPROFIBUS/DP network.
This interface module provides your FX1N, FX2N,FX2NC orFX3U CPU with an intelligentPROFIBUS/DP link for the implementation of decentralised control tasks.
It linksthe system to the master PLC in the PROFIBUS/DP network for efficient andtrouble-free data exchange.
Note: When attaching thismodule to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF is required.
Network Module for Profibus/DP FX1S FX1N FX2N FX2NC FX3U
0NFX -32NT-DP
POWER
BF DIA
DC RUN
/// NETWORKMODULES
-
7/25/2019 Plc Fx Family
42/9042 MITSUBISHI ELECTRIC
Remote I/OStationFX2N-32DP-IF
The remote I/O station FX2N-32DP-IF forms an extremely compact communication unitand provides a connection of I/O modules with up to 256I/O points and/or up to 8 special
function modules as an alternative.It features an entireelectrical isolation of the PROFIBUS/DP connector and of thesensor/actuator circuits.
The FX2N-32DP-IFincludes a 240V power supply unit anda 24 V servicevoltageterminal,e.g. foranalog modules.The FX2N-32DP-IF-D is supplied with 24 V DC.
PROFIBUS data such as thebaudrate or I/Odatacan be monitored directlywiththe pro-gramming softwareor on the hand-held programming unit FX-20P-E.This facilitatesaneasyerror diagnosis directly on the remoteI/O station.
Remote I/O Station for PROFIBUS/DP
MITSUBISHI
COM 24+
L N
FX -32DP-IF2N
POWER
RUN
STOP
RUN
BF
DIA
ON
OFF
64
32
16
8 4 2 1
Specifications FX2N-32DP-IF FX2N-32DP-IF-D
Order information
NETWORKMODULES ///
-
7/25/2019 Plc Fx Family
43/9043MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
Network Module for DeviceNet FX1S FX1N FX2N FX2NC FX3U
Specifications FX2N-64DNET
Order information
DeviceNetSlaveModuleFX2N-64DNET
The DeviceNet slave module FX2N-64DNET can be used to connectFX2N, FX2NC and FX3Uprogrammable controllers to a DeviceNet network.
The FX2N-64DNET can communicate to the masterby the master/slave communication(using the master/slaveI/O connection),and to other nodes supporting the UCMM con-nection by client/server communication (using the UCMM connection).
The communication between the programmable controller and the internal buffermemory of the FX2N-64DNET is handled by FROM/ TO instructions.
Note: When attaching thismodule to a FX2NC baseunit,theinterfaceadapterFX2N-CNV-IF is required.2NFX -64DNET
POWER
/TO
MS
NS
Network Module for CANopen FX1S FX1N FX2N FX2NC FX3U
The FX2N-32CAN communications module makes it possibleto connectan FX1N/FX2N/FX2NC orFX3U PLC to an existing CANopen network.
In addition to real-time capabilities and high-speed data transfer at rates of up to 1Mbit/sthe CANopen module alsoshines with high transfer reliability and simple network config-uration. Up to 120 data words can be sent andreceived as process data objects(30 PDOs).
The number of words thatcan be transmitted in eachdirectioncan be set between1 and 120.
Communicationwiththe modules memory buffer is performed with simple FROM/TOinstructions.
Specifications FX2N-32CAN
Order information
FX -32CAN2N
POWER
RUN
FROM/TO
Tx/Rx
ERROR
/// NETWORKMODULES
-
7/25/2019 Plc Fx Family
44/9044 MITSUBISHI ELECTRIC
CommunicationsModulesFX2NC-485ADP, FX3U-485ADP
Thecommunicationmodules FX2NC-485ADP and FX3U-485ADP enable the configuration of1:nmultidrop,parallel linkor peer-to-peer networks using the RS485 interface.
Note: the FX2NC-485ADP canonlybe used in combination with the FX2NC base units.FX3U-485ADP can only be used with theFX3U.
Specifications FX2NC-485ADP FX3U-485ADP
Order information
110
330
OPEN
POWER
FX3U-485ADP
SG
RDA
RDB
SDA
SDB
RD
SD
POWER
RD
SD
FX -485ADP2NC
RDA
RDB
SDA
SDB
SG
FX3U-485ADP
FX2NC-485ADP
Communications Adapter FX1S FX1N FX2N FX2NC FX3U
Communications Adapters FX1S FX1N FX2N FX2NC FX3U
CommunicationAdaptersFX1N-CNV-BD andFX2N-CNV-BD
The communication adapters FXN-CNV-BD enable connection of the FX0N-232ADP andFX0N-485ADPspecial functionmodules to the left-hand sideof the FX1N andFX2N baseunits.
Specifications FX1N-CNV-BD FX2N-CNV-BD
Order information
FX -CNV-IF2N
MITSUBISHI
FX -CNV-BD2N
JY331B89201B
Communications Modules FX1S FX1N FX2N FX2NC FX3U
Specifications FX2N-CNV-IF FX2NC-CNV-IF
Order information
InterfaceAdapters FX2N-CNV-IF, FX2NC-CNV-IF
The FX2N-CNV-IF interface allows standard FX expansion blocks and specialfunctionmodules tobe connected to an FX2N PLC and theFX2NC-CNV-IF interface allows standardFX2N expansion blocks and specialfunction modules to be connected to an FX2NC PLC.
COMMUNICATIONSMODULES ///
-
7/25/2019 Plc Fx Family
45/9045MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
Interface Modules FX1S FX1N FX2N FX2NC FX3U
ActiveData InterfaceModules FX2NC-232ADP, FX3U-232ADP
The additional active data interface modules permit active communication between thePLC and surrounding RS232C peripherals.All deviceinformation can be sent or receivedvia these interfaces.
The module is suitable for the connection of printers, bar code readers,PCs and other PLCsystems. The communication is handled by the PLC program using the RS instruction.
The connection is to the communications bus on the left side of the controller.The internal serial RS422 interface is also fully available.
Note: The FX2NC-232ADPrequires a FX2N-CNV-BDor FX1N-CNV-BDinterface adapterwhen connectingto a FX1S,FX1Nor FX2N baseunit. TheFX3U-232ADPcan onlybe usedwiththe FX3U andrequiresa func-tion extension board.
Specifications FX2NC-232ADP FX3U-232ADP
Order information
InterfaceModule FX2N-232IF
The interface module FX2N-232IF provides an RS232C interfacefor serial data communi-cationswith the MELSEC FX2N, FX2NC andFX3U.
Communication with PCs, printers,modems,barcode readers etc. is handled by the PLCprogram.
The send and receive data are stored in the FX2N-232IFs own buffer memory.
Changesat the user program arenot possiblevia thisinterface module.
Note: When attaching thismodule toa FX2NCbase unit,the interfaceadapterFX2N-CNV-IF is required.
Specifications FX2N-232IF
Order information
POWER
FX3U-232ADP
RD
SD
POWER
RD
SD
FX -232ADP2NC
FX3U-232ADP
FX2NC-232ADP
/// COMMUNICATIONSMODULES
-
7/25/2019 Plc Fx Family
46/9046 MITSUBISHI ELECTRIC
Digital Extension Adapter Boards FX1S FX1N FX2N FX2NC FX3U
Extension Adapters FX1N-4EX-BD, FX1N-2EYT-BD
The extension adapters for the FX1N series are available with 4 inputs or 2 outputs.They are installed directly in the controller of the FX1S orFX1N series and thereforedo notrequire any additional installation space.
These adapters are especially advantageous when only few additional I/Os are requiredandthere is not enough roomfor an adjacent module to be installed.
Specifications FX1N-4EX-BD FX1N-2EYT-BD
Order information
FX1N-2EYT-BD
BY0+
BY0-BY1+BY1-
Connector side
FX1N-2EYT-BD
EXTENSIONADAPTERS ///
AnalogAdapter Boards FX1N-2AD-BD, FX1N-1DA-BD
The analog input adapter board FX1N-2AD-BD provides the user with 2 analog inputs.
The board converts analog process signals into digital values which are further processedby the MELSEC FX1S/FX1N controller.
The analog adapter FX1N-1DA-BD provides the userwith 1 analog output.The moduleconverts digital values from the FX1S/FX1N controllerto the analog signalsrequiredby theprocess.
Specifications FX1N-2AD-BD FX1N-1DA-BD
Order information
FX1N-2AD
BY0+
BY0-BY1+
BY1-
FX1N-1DA-BD
V+
I+
VI+
Connector side
FX1N-2AD-BD
Connector side
FX1N-1DA-BD
Analog Adapter Boards FX1S FX1N FX2N FX2NC FX3U
-
7/25/2019 Plc Fx Family
47/9047MITSUBISHI ELECTRIC
SPECIALFUNCTIONMODULES
Setpoint Adapter Boards FX1S FX1N FX2N FX2NC FX3U
Adapter BoardFX3U-USB-BD
This adapter board allows direct USB 2.0 connection to the front of the FX3U PLC forpro-gram maintenance.
Specifications FX3U-USB-BD
Order information
FX -CNV-BD2N
JY331B89201B
Communications Adapters FX1N-CNV-BD, FX2N-CNV-BD, FX3U-CNV-BD
The FXN-CNV-BDadapters enable connection of the FX-ADPspecial function modules tothe left-hand side of the FX base units.
Specifications FX1N-CNV-BD FX2N-CNV-BD FX3U-CNV-BD
Order information
RD
SD
FX3U
-USB
-BD
Connector side
FX2N-CNV-BD
/// COMMUNICATIONSADAPTER BOARDS
AnalogSetpointAdapters FX1N-8AV-BD andFX2N-8AV-BD
The FXN-8AV-BDanalog setpoint adapters enable the user to set 8 analog setpointvalues.The analog valuesof the potentiometers are read into the controller and used as
defaultsetpoint values fortimers, counters and data registers by the users PLC programs.
Setpoint value pollingand the definition of the potentiometer scales areperformedin thePLC program using the dedicated instructions VRRD/VRSC (FNC85/86).
The FXN-8AV-BDanalogsetpoint adapters areinstalled in the expansion slot of theFX1S/FX1N/ FX2N CPU. No additionalpowersupply is required foroperation.
Specifications FX1N-8AV-BD FX2N-8AV-BD
Order information
JY
331B
88801B
Connector side
FX2N-8AV-BD
Communications Adapter Boards FX1S FX1N FX2N FX2NC FX3U
Communications Adapter Boards
FX1S FX1N FX2N FX2NC FX3U
-
7/25/2019 Plc Fx Family
48/9048 MITSUBISHI ELECTRIC
Interface Adapters FX1N-232-BD, FX2N-232-BD,FX3U-232-BD
The FX-232-BD interface adapters providean RS232C interface forserial data commu-nications with the MELSEC FX1S/FX1N/FX2N/FX3U.
Specifications FX1N-232-BD FX2N-232-BD FX3U-232-BD
Order information
Interface Adapters
JY
331B
89001
C
FX
-2
32-BD
2N
FX -422-BD2N
JY331B89101B
InterfaceAdapters FX1N-485-BD, FX2N-485-BD, FX3U-485-BD
The interface adapters FX-485-BD providethe controller with an additional RS485interface.The adapter, which is simply inserted into the baseunits expansion slot, enablesthe configurationof RS485 1:n multidrop, parallel linkor peer-to-peer networks withFX1S/FX1N/FX2N/FX3U systems.
Specifications FX1N-485-BD FX2N-485-BD FX3U-485-BD
Order information
RDA
RDB
SDA
SDB
SG
JY
331B
88901
C
FX
-4
85-BD
2N
Specifications FX1N-422-BD FX2N-422-BD FX3U-422-BD
Order information
InterfaceAdapters FX1N-422-BD, FX2N-422-BD, FX3U-422-BD
The FX-422-BD interface adapters provide a second RS422 interface forconnectionofan additional device to the controller (programming unitor operator terminal).
Connector side
FX2N-232-BD
Connector side
FX2N-422-BD
Connector side
FX2N-485-BD
INTERFACEADAPTERS ///
-
7/25/2019 Plc Fx Family
49/9049MITSUBISHI ELECTRIC
ACCESSORIES
Memory Media
MemoryCassettes forFX1S, FX1N and FX2N
AllFX1S, FX1N and FX2N base units are equipped with a slot for theoptional,robust FXmemory cassettes. By connection of these memory cassettes, the internal memory of thecontroller is switched off and only the program specified in therespectivememorycassetteis run.
The memory size can be extended for all FX2N controllers up to 16,000 steps with thememory cassette FX-RAM-8.
The FX2N-ROM-E1 memory module simplifies the direct communication between theFX2N and the Mitsubishi Electric frequency inverters of the series FR-S500, FR-E500and FR-A500. The FX2N-ROM-E1 technically corresponds to the FX-EEPROM-16.
Specifications FX-RAM-8 FX-EPROM-8 FX-EEPROM-4
Order information
Specifications FX-EEPROM-8 FX1N-EEPROM-8L FX-EEPROM-16 FX2N-ROM-E1
Order information
WR
PROTECT
SW
ON
OFF
8L PLC
8L PLCRD
Specifications FX2NC-ROM-CE1 FX2NC-EEPROM-16 FX2NC-EEPROM16C FX2NC-EEPROM-4C FX2NC-RTC
Order information
MemoryandReal-timeClockCassette
All the FX2NC baseunits have a slot foraddinga memory and real-time clock cassettes.TheFX2NC-ROM-CE1 module contains both EEPROM memory and a real-time clock.TheFX2NC-EEPROM-16 provides only memory, without the clock feature,whilethe FX2NC-RTCis a real-time clock cassette for the FX2NC PLCs without any additional memory.
FX2NC-EEPROM-16
FX1N-EEPROM-8L
FX-EPROM-8
MemoryCassettes forFX3U
The memory cassette can be installed at the main unit, and when installed, the memorycassettes internal program is used in place of the internal RAM memory.
The FX3U-FLROM-64L features additional data transfer buttons.
Specifications FX3U-FLROM-16 FX3U-FLROM-64 FX3U-FLROM-64L
Order information
FX3U-FLROM-64L
///MEMORY CASSETTES
-
7/25/2019 Plc Fx Family
50/9050 MITSUBISHI ELECTRIC
Terminal Blocks FX1N FX2N FX2NC FX3U
These terminal blocks are adapter modules that simplify the wiring of the inputs and out-putsof the FX2NC units with ribbon cable connectors.This practical,time-saving wiringsystem alsoimprovesthe performance of the outputs.Special terminal blocks arealsoavailable for the FX2N positioning modules with ribbon cable connectors.
Input blocks, output blocks and combined I/O blocks are available,witha choice of differ-ent terminal types.
The TB-EX input blocks arefitted with rows of connectors forKelvin terminals(24V / 0 V),whichmakewiring quick and easy.
The TB-8EY-S and TB-8EY-C output blocks consist of 8 standard terminals and a systemadapter.The standard terminals can be populated with relay or transistor elements,which makes it possible to configure the system formuch higher output currents.
Preconfigured system cabling is available forall the terminal blocks (see nextpage).
24
V
24
V
24
V
24
V
24
V
24
V
24
V
24
V
A2- A2- A2- A2- A2- A2- A2- A2-
24V+
PLC-V8/FLK14/O
UT
Art.2295554
-
.0 .1 .2 .3 .
4 .5 .6 .7
Specifications TB-8EY-S TB-8EY-C TB-20-S TB-20C
Order information
Accessories
Specifications TB-8EX-S TB-8EX-C TB-16EX-S TB-16EX-C
Order information
Accessories
2018161412108642
.7.6.5.4.3.2.1.0
TB-20C
TB-EX
TB-EY
Thetransistor andrelayelementsareplugged
directly into thestandardterminals in theTB-8EY-S or TB-8EY-C modules.All theelementsfeaturea status LED,protectionagainst reversepolarity connection and afreewheelingdiode.
Neighbouring terminals with identical
voltages can be connected with plug-instrip bridgeconnectors,which can be cutto length as required.
System adapter
Socket
Baseterminal
Specifications TB-8RELAY-6A TB-8TRANSISTOR-2A
Order information
Accessories
Catch
LED statusdisplay
Contact forplug-in stripbridge
Terminal opertionaperture
Notch lever forsecuring andejecting
Construction of thebase terminal
Power supplyterminal
Insertedrelay ortransistorelement
EXTERNAL TERMINAL BLOCKS ///
-
7/25/2019 Plc Fx Family
51/9051MITSUBISHI ELECTRIC
ACCESSORIES
Terminal Connection Cable FX1S FX1N FX2N FX2NC FX3U
These preconfiguredcables enable quick,error-freewiring of the terminalblocks of theFX2NC base andexpansion units andthe positioning modules of theFX2N series fitted withribbon cable connectors.
The cables are availablein a choice of lengths between1 and 5 m. Other lengthsare alsopossibleby special order.
Specifications TB-EX-CAB-1M TB-EX-CAB-3M TB-EX-CAB-5M
Order information
Specifications TB-EY-CAB-1M TB-EY-CAB-3M TB-EY-CAB-5M
Order information
Connection terminals FX1S FX1N FX2N FX2NC FX3U
The base unit FX2NC-16MR-T-DS and the extension units FX2NC -16EX-T-DS andFX2NC-16EYR-T-DS arefitted with screw terminals as standard equipment.
These plug-in terminals can easily be replaced with spring terminals if required.Tworeplacement terminal units are required foreach module with 16 I/Os.
Specifications TB-CON10-C TB-CON-11C
Order information
24 V Power Supply Unit FX1S FX1N FX2N FX2NC FX3U
The Alpha Power is a convenient power supply for the 24 V units and other externaldevices.It comes with a DIN rail mounting system and its dimensionsare matched tothose of the MELSEC FX family.
Two Alpha Power units can be installed together for redundant mode operation or con-nected in parallel formore power. The units have an integrated thermal overload protec-tion circuit.
Specifications ALPHA P OWER 2 4-1,4
Order information
ALPHAPOWER
24-1.5
DC24V 1.5AAC100-240V
/// CABLES ANDPOWERSUPPLY
-
7/25/2019 Plc Fx Family
52/9052 MITSUBISHI ELECTRIC
Specifications F2-RS-5CAB F2-232CAB-1 FX-232CAB-1
Order information
Cables FX1S FX1N FX2N FX2NC FX3U
FX Series connection cables
The cable listed in the following tables are used for FX Series PLC programming,position-ing applications,block connections and interface conversion.
Specifications FX-20P-CAB0 FX-20P-CAB FX-20P-CADP
Specifications FX0N-65EC
Order information
Specifications FX-USB-AW FX-232AWC-H
Order information
Connection cable for programming unit
Connection cable for RS232C peripherals
FX-20P-CAB0
FX-16E-500CAB
Connection cable for extensionbus
FX0N-65EC
Interface converter
Specifications FX-422CAB0 FX-422CAB FX-422CAB-150
Order information
Connection cable for RS-422 peripherals
Batteries
The battery buffers the internal RAM of the MELSEC PLC in the event of a voltagefailure.
The battery F2-40BL can be used for all base units of the MELSEC FX2N series.
The battery FX2NC-32BL is suitablefor allbaseunits of the MELSEC FX2NC series and for thepositioningmodules FX2N-20GM.
The battery FX3U-32BL canbe used for allbaseunits of the MELSEC FX3U series.
Specifications F2-40BL FX2NC-32BL FX3U-32BL
Order information
F2-40BL
Backup Batteries FX1S FX1N FX2N FX2NC FX3U
CABLES ANDBATTERIES ///
-
7/25/2019 Plc Fx Family
53/9053MITSUBISHI ELECTRIC
ACCESSORIES
Display Modules
DisplayModule FX1N-5DM
The display module is inserted directly into the FX1S and FX1N series controllers andenables monitoring and editing of the data storedin the PLC.
The display module e.g.can be used instead of digital switches and external 7-segmentdisplays in very confined areas.
Specifications FX-10DM-E
Order information
Control andDisplay Panel FX-10DM-E
The control and display panel FX-10-DM-E provides a key-oriented user-interface andenables you to monitor and edit process data in the PLC.
The display is arranged in 2 rows of 16 characters each. Functions can be invoked andvalues can be editedusing thepanel keys.
Specifications FX1N-5DM
Order information
MITSUBISHI
ESC - + OK
CLR FNC ENT
Control andDisplay Panel FX3U-7DM,Holder FX3U-7DM-HLD
The FX3U-7DM display module can be incorporated in the main unit, or can be installed inthe enclosure using the FX3U-7DM-HLD display module holder.