PLC Connection Guide - Cermate · HMI COM2 LUST ServoC HMI Side PLC Cable Side COM1 9-PIN Male LUST...
Transcript of PLC Connection Guide - Cermate · HMI COM2 LUST ServoC HMI Side PLC Cable Side COM1 9-PIN Male LUST...
Technical Document
Version 0.0
November, 2008
www.cermate.com
PLC Connection Guide
TN526D
Communication settings between LUST ServoC/CDE and PanelMaster
◎Revision Record
Revision Date Content Owner
TND526-E0
Page 2 of 9 www.cermate.com
Preface
This tech note introduces how to connect LUST ServoC controller with PanelMaster
HMI.
X5 --- CANopen / RS485
X6 --- USB Port
TND526-E0
Page 3 of 9 www.cermate.com
(1) PLC Parameter setting:
(a) Please install the program software “LTi DriveManager” to your PC and then plug-in the USB Cable into LUST controller.
(b) When the USB cable link with the LUST controller, the software will install the USB driver automatically.
(c) If the USB driver was installed successfully, you will link with the LUST controller via USB cable directly.
TND526-E0
Page 4 of 9 www.cermate.com
(d) When you link with the LUST controller, please set the User Level to: Develop Engineer (6). (Initial Password is “678”)
(e) At this moment, please enter “Extras --- Parameter Editor” and set the RS485 value as “1” to enable the RS485 communication.
TND526-E0
Page 5 of 9 www.cermate.com
NOTE:
If you enable the RS485 communication, the USB port will not be linking with
the LUST controller at the same time.
Connection Cable Diagram:
HMI Side PLC Cable Side
COM1 9-PIN Male
PV-Series
LUST ServoC (X5)
DB9 male (RS485)
TXD + 1 5 DATA+
TXD - 6 4 DATA-
GND 5 3 GND
9 DC +24V
6 DC 0V
TND526-E0
Page 6 of 9 www.cermate.com
HMI COM2 LUST ServoC
HMI Side PLC Cable Side
COM1 9-PIN Male
LUST ServoC (X5)
DB9 male (RS485)
TXD + 1 5 DATA+
TXD - 4 4 DATA-
GND 5 3 GND
9 DC +24V
6 DC 0V
NOTE:
If you wish to use the RS485 to link with the HMI, the X5 connector meeds to
poovides DC24V power from Pin9 and Pin6.
TND526-E0
Page 7 of 9 www.cermate.com
(2) HMI setting:
Select 【Direct Link [COM] 】&【Device/Server: Lust Antriebstechnik GmbH→ LustBus ServoC/CDE
Series】
Set the Parameter as “57600; 7, Even, 1” and PLC Address=“1”.
TND526-E0
Page 9 of 9 www.cermate.com
Technical Support Information
中國大陸 QQ專線 : 800014850 www.panelmaster.com.cn / www.cermate.com
資料下載專區 ftp:://mail.cermate.com + User name + Password (欲加入會員需要申請)
合作貼牌聯絡專線: China: 0910011916 / 86-13823788405 [email protected] Taiwan: 886-910011915 [email protected]
Worldwide: 886-910011914 [email protected]
Cermate Technologies (Shanghai) Inc. 屏通科技(上海)有限公司
Phone: +86-21-51758590~2 FAX : +86-21-51758589
E-mail: [email protected]
Shenzhen Cermate Technologies Inc. 屏通科技(深圳)有限公司
Phone: +86-755-83562179, FAX : +86-755-83562294
E-mail: [email protected]
Cermate Technologies Inc. (台湾) 屏通科技股份有限公司 7F-1, No. 168, Lien-Cheng Road, Chung-Ho City, Taipei, Taiwan 235 R.O.C.
Phone: 886-2-22437000 FAX : 886-2-22499933
E-mail: [email protected]