GRIDSTREAM
COMMAND CENTER™
RELEASE NOTES
Release 7.0 Maintenance Release 2
Publication: 98-1890 Rev AA
Confidential & Proprietary
By accepting this document, each recipient agrees never to distribute this to others in whole or in part without the prior written consent of Landis+Gyr. Unauthorized copies are prohibited by law. Landis+Gyr, Copyright © 2017
Landis+Gyr
2 98-1890 Rev AA Command Center 7.0 MR2
Table of Contents
Purpose of This Maintenance Release ............................................................................................ 4
Supported Software, Devices and Firmware .................................................................................. 4
Software ........................................................................................................................................................ 4
Devices .......................................................................................................................................................... 5
Supported Residential Electric Endpoints ............................................................................................. 5
Supported C&I Electric Endpoints ......................................................................................................... 5
Supported Water Endpoints ................................................................................................................. 6
Supported Gas Endpoints ..................................................................................................................... 6
Supported Network Equipment ............................................................................................................ 6
Firmware ....................................................................................................................................................... 7
RF Mesh Endpoints ............................................................................................................................... 7
RF Mesh Gas .......................................................................................................................................... 8
RF Mesh Water ..................................................................................................................................... 8
Asia-Pacific ............................................................................................................................................ 9
RF Mesh Network Equipment ............................................................................................................... 9
RF Mesh IP (SBS) ................................................................................................................................. 10
Electric ................................................................................................................................................. 10
RF Mesh IP (SBS) Gas........................................................................................................................... 11
Gridstream PLX.................................................................................................................................... 11
Gridstream PLC (TS2) .......................................................................................................................... 11
TS1 ....................................................................................................................................................... 12
PLC Tool ............................................................................................................................................... 12
Command Center 7.0 Gridstream RF Electric Firmware Backward Compatibility .............................. 13
Installation Instructions ................................................................................................................ 13
Resolution for TFS 528715 .......................................................................................................................... 13
Defects Resolved ........................................................................................................................... 15
Command Center ........................................................................................................................................ 15
Integration .................................................................................................................................................. 18
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 3
CIM 2nd Edition Event ID Updates ............................................................................................................... 19
CIM 2nd Edition Reading Type ID Updates ................................................................................................... 22
Landis+Gyr
4 98-1890 Rev AA Command Center 7.0 MR2
PURPOSE OF THIS MAINTENANCE RELEASE This is the second maintenance release (MR2) for Command Center 7.0.
SUPPORTED SOFTWARE, DEVICES AND FIRMWARE
Software The following software is supported in the Command Center 7.0 MR2 release:
Command Center 7.0 MR2 Companion Component Versions
Command Center 7.0.0.287
Gridstream Integration Suite 7.0.0.282
SBS Adapter 1.0.15.254
ABNT Adapter 1.0.3.283
Mobile Administration Software (MAS) 7.0.0.282
Endpoint Administration Software (EAS) 7.0.0.282
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 5
Devices The following devices are supported in the Command Center 7.0 release:
Supported Residential Electric Endpoints • Landis+Gyr FOCUS AX Modular • Landis+Gyr FOCUS AX Integrated • Landis+Gyr FOCUS AL • Landis+Gyr FOCUS AL 2G • Landis+Gyr Enhanced FOCUS AX Modular (includes the new 4MB and 8MB flash
versions) • Landis+Gyr Enhanced FOCUS AX Integrated • Landis+Gyr Enhanced FOCUS AXe • Landis+Gyr Integrated G5 FOCUS AXe • Landis+Gyr G5 FOCUS AXe • Landis+Gyr G5i FOCUS AXe • Elster REX Universal • Enhanced Cellular FOCUS AXe • Enhanced Cellular U1200 • Enhanced Cellular U1300 • Enhanced Cellular U3350 • Enhanced Cellular U3400 • Series V U1200 RF SBS • Series V U1200 RF SBS • Series V U3400 RF SBS • Series V U3350 RF SBS
Supported C&I Electric Endpoints • Landis+Gyr S4e • Landis+Gyr S4x • Landis+Gyr G5 S4x • Landis+Gyr G5i S4x • Landis+Gyr FOCUS AX Polyphase • Landis+Gyr Enhanced FOCUS AX Polyphase • Landis+Gyr Enhanced S4e • Elster A3 • Enhanced Elster A3 • GE kV2c • Enhanced GE kV2c • G5i E650 G2
Landis+Gyr
6 98-1890 Rev AA Command Center 7.0 MR2
Supported Water Endpoints • Two-Way Water
o Pit module o Wall module o Interpreter
Supported Gas Endpoints • RF Mesh
o Two-Way Gas Residential M120 o Two-Way Gas C&I M220 o Two-Way Pressure and Temperature Gas Module M250
• RF Mesh IP
o Two-Way Gas Residential M120i o Two-Way Gas C&I M220i o Two-Way Pressure and Temperature Gas Module M250i
Supported Network Equipment • Series 3 Router • Series 4 Router • Series 5 Router • Universal Mesh Extender (UME) • Series 3 Collector • Collector C6400 Series • Collector C6500 Series • Collector C7400 Series • Collector C7500 Series • Series 3 Concentrator • Series 4 Concentrator • Series 3 IWR • Series 4 IWR • Series 5 IWR • DA Devices • Network Node
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 7
Firmware The following products are qualified and available for upgrades with use in Command Center versions 7.0 and higher:
RF Mesh Endpoints Hardware Type Firmware
Version DCW Identification DCW Filename Metrology ZigBee
FOCUS AX Modular 10.53 1B0D.10.61 FAXG.10.61.hex 5.38 2.00.07
Enhanced FOCUS AX Modular (Series 4) (includes the new 4MB and 8MB flash versions)
10.53 1F0D.10.61 FAXG.10.61.hex 5.38 2.03.08
Enhanced FOCUS AXe (Series 4)
10.53 1F0D.10.61.00014 FAXG.10.61.hex 5.68 2.03.08
G5 FOCUS AXe (Series 5)
10.53 240D.10.61.00014 FAXG.10.61.hex 5.68 2.03.08
G5 Integrated FOCUS AXe (Series 5)
10.53 240D.10.61.00014 FAXG.10.61.hex 5.68 2.03.08
Integrated FOCUS AX 10.53 1A01.10.61 FAXG.10.61.hex 5.38 2.00.07
Enhanced Integrated FOCUS AX (Series 4)
10.53 2001.10.61 FAXG.10.61.hex 5.45 2.03.08
FOCUS AL 10.53 1B0C.10.61 FALG.10.61.hex 3.341 NA
FOCUS AL 2G 10.53 1603.10.61 FAL2.10.61.hex 3.341 NA
Enhanced Elster REX Universal
10.53 2301.10.61 REXU.10.61.hex 1.8 2.03.08
Elster A3 10.53 1801.10.61 EA3G.10.61.hex 5.3 NA
Enhanced Elster A3 10.53 1F01.10.61 EA3G.10.61.hex 5.3 2.03.08
1 The 3.34 is a decimal interpretation of the 3.22 hexadecimal values, which is tracked in the FOCUS AL metrology.
Landis+Gyr
8 98-1890 Rev AA Command Center 7.0 MR2
Hardware Type Firmware Version
DCW Identification DCW Filename Metrology ZigBee
(Series 4)
GE kV2c 10.53 1802.10.61 kV2G.10.61.hex 4.00 NA
GE kV2c (v1.0.1) 10.53 1806.10.61 kV2G.10.61.hex 4.00 NA
Enhanced GE kV2c (Series 4)
10.53 1F02.10.61 kV2G.10.61.hex 4.11 2.03.08
S4e 10.53 1804.10.61 S4eG.10.61.hex 6.342 NA
Enhanced S4e (Series 4) (includes the 4MB and 8MB flash versions)
10.53 1F04.10.61 S4eG.10.61.hex 6.342 2.03.08
Enhanced S4x (Series 4) 10.53 1F0D.10.61.0008 S4xG.10.61.hex 8.11 2.03.08
G5 S4x (Series 5) 10.53 240D.10.61.0008 S4xG.10.61.hex 8.11 2.03.08
RF Mesh Gas Hardware Type
Module Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
M120 Residential Gas 3.62 N/A N/A N/A
M220 C&I GPR 3.62 N/A N/A N/A
M250 – GPR-PT 3.62 N/A N/A N/A
RF Mesh Water Hardware Type
Module Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
Two-Way Water 2.02 NA NA NA
2 The 6.34 metrology firmware for the S4e is not available Over-the-Air (OTA).
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 9
Asia-Pacific Hardware Type
Modem Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
Enhanced Cellular U1200
5.5.18 09.20 / 09.33 5.05 2.03.08
Enhanced Cellular U1300
5.5.18 09.20 / 09.33 5.05 2.03.08
Enhanced Cellular U3350
5.5.18 09.20 / 09.33 5.05 2.03.08
Enhanced Cellular U3400
5.5.18 09.20 / 09.33 5.05 2.03.08
RF Mesh Network Equipment Hardware Type Firmware
Version DCW Identification DCW Filename Metrology ZigBee
Series 3 Router 10.53 1501.10.61.0010 Rout.10.61.hex NA NA
Series 4 Router 10.53 1D01.10.61.0010 Rout.10.61.hex NA NA
Series 5 Router 10.53 2101.10.61.0010 Rout.10.61.hex NA NA
Collector Application 4.8.8 NA NA NA NA
Series 3 Collector 10.53 157F.10.61.0011 Coll.10.61.hex NA NA
C7400 Collector 10.53 1D7F.10.61.0011 Coll.10.61.hex NA NA
C7500 Collector 10.53 217F.10.61.0011 Coll.10.61.hex NA NA
C6400 Collector 10.53 1D7F.10.61.0011 Coll.10.61.hex NA NA
C6500 Collector 10.53 217F.10.61.0011 Coll.10.61.hex NA NA
Series 3 IWR 10.53 1501.10.61.0010 Rout.10.61.hex NA NA
Series 4 IWR 10.53 1D01.10.61.0010 Rout.10.61.hex NA NA
Series 5 IWR 10.53 2101.10.61.0010 Rout.10.61.hex NA NA
Series 3 Concentrator 10.53 1501.10.61.0012 Conc.10.61.hex NA NA
Series 4 Concentrator 10.53 1D01.10.61.0012 Conc.10.61.hex NA NA
Network Node (N500) 10.53 2D01.10.61.0010 Rout.10.61.hex NA NA
Landis+Gyr
10 98-1890 Rev AA Command Center 7.0 MR2
RF Mesh IP (SBS)
Electric Hardware Type
Module Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
G5i FOCUS AXe N/A 10.64/10.66 5.68 2.03.08
G5i S4x N/A 10.64/10.66 8.11 2.03.08
G5i Router N/A 10.64/10.66 N/A N/A
G5i Collector N/A 10.64/10.66 N/A N/A
Collector Application (Ubuntu)
NA 2.1.22 N/A N/A
Collector Application (BuildRoot)3
N/A 2.2.3
N/A N/A
SOUTH AMERICA G5i SGP+M 3 IWR N/A 10.64/10.66 N/A N/A
G5i 3rd party meters IWR N/A 10.64/10.66 N/A N/A
G5i Power Vault IWR N/A 10.64/10.66 N/A N/A
G5i Recloser IWR N/A 10.64/10.66 N/A N/A
G5i E430 ABNT N/A 10.64/10.66 1.28 N/A
G5i E450 ABNT N/A 10.64/10.66 1.28 N/A
G5i E650 G2 ABNT N/A 10.64/10.66 51.044 1.185
N/A
G5i E750 G2 ABNT N/A 10.64/10.66 1.18 N/A
ASIA- PACIFIC
3 This is not GA
4 Energy Balance
5 Inmetro Version
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 11
Hardware Type
Module Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
Series V U1200 RF SBS N/A 10.64/10.66 05.05 N/A
Series V U1300 RF SBS N/A 10.64/10.66 05.05 N/A
Series V U3400 RF SBS N/A 10.64/10.66 05.05 N/A
Series V U3350 RF SBS N/A 10.64/10.66 05.05 N/A
RF Mesh IP (SBS) Gas Hardware Type
Module Firmware
Firmware/DCW SBS Bundle
Metrology
ZigBee
M120i Residential Gas 4.58 N/A N/A N/A
M220 C&I GPR 4.58 N/A N/A N/A
M250i – GPR-PT 4.58 N/A N/A N/A
Gridstream PLX Hardware Type Firmware Version Metrology
Collector 3000 (FASY-0632-0016, FASY-0632-0019, FASY-0632-0021)
6.0.1.247 3.0.1.21.3000
NA
FOCUS AL 9.20 3.34
FOCUS AX, AX-SD 9.20 5.35, 5.37
S4e 9.20 6.32
Gridstream PLC (TS2) Hardware Type Firmware Version Metrology
SPU 2000 – VxWorks 2.15.0.60 / 2.12.35 NA
SPU 2000 – Linux 4.3.2.32 / 2.12.33 NA
Collector 3000 – VxWorks (FASY-0632-0012 and under)
2.15.0.60 / 2.3.14.3000 NA
Collector 3000 – Linux 4.3.2.32 / 2.03.14.3000 NA
Landis+Gyr
12 98-1890 Rev AA Command Center 7.0 MR2
Hardware Type Firmware Version Metrology
(FASY-0632-0012 and under)
Remote Service Switch (RSS) 9 NA
Load Control Switch (LCS) 13 NA
GE kV2c 40 4.0 or later
Itron Centron 30 NA
Standard AMR 22 NA
FOCUS AL 25 3.34
FOCUS AX, AX-SD/ZigBee 21/10 5.34 only
S4e 49 7.18
TS1 Hardware Type Firmware Version Metrology
Collector 1000 – VxWorks 2.15.0.60 / 1.10.3 NA
Collector 1000 – Linux 4.3.2.32/ 1.10.03 NA
Collector 3000 – VxWorks (FASY-0632-0012 and under)
2.15.0.60 / 1.7.9.3000 NA
Collector 3000 – Linux (FASY-0632-0012 and under)
4.3.2.31 / 2.03.14.3000 NA
TS1 S4e 7 7.12
TS1 DRR GE kV2c 19 4.0
TS1 Mechanical 4 NA
PLC Tool Hardware Type Firmware Version Metrology
OptoWand+ 21 NA
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 13
Command Center 7.0 Gridstream RF Electric Firmware Backward Compatibility Command Center 7.0 supports the following AMI firmware versions:
RF Mesh
• 10.06 • 10.05 • 10.03 • 10.01 • 9.58 • 9.57 • 9.56
RF Mesh IP
• 10.55 • 10.54 • 10.07
INSTALLATION INSTRUCTIONS
Resolution for TFS 528715 Power Outage and Restore events were not being encrypted while in Advanced Security mode for customers deploying RF Mesh IP on Microsoft SQL Server. Please use the following steps:
1. Enable a setting in below web.config file: Setting Name: DropUnexpectedUnencryptedMessages File Location: Hunt Technologies Inc\TS2\Web\GridstreamSecurityServiceHost\web.config
2. Run below SQL script in CentralServices database: DECLARE
@settingsId INT,
@settingsValue varchar(255)
BEGIN
SET @settingsId = 1040;
Landis+Gyr
14 98-1890 Rev AA Command Center 7.0 MR2
SET @settingsValue = '0';
INSERT INTO SettingsValues ( settingsId ,settingsValue )
SELECT @settingsId, @settingsValue
WHERE NOT EXISTS (SELECT 1 FROM SettingsValues WHERE settingsId = @settingsId );
END;
3. Upgrade Collector Firmware Version: S5SC21-10.76.001_Rout.10.67 Steps to Upgrade Firmware:
a) Import the firmware .hfz file in Command Center, SetupFirmwareCommunication Module. Click on Import, browse and select the .hfz file, then click Import.
b) After importing the firmware in Command Center, SetupCollectors, select the collector in which radio you want to upgrade firmware.
c) On the Collector Information page, select the collector radio under Collector Radios section.
d) When the Collector Radio Endpoint Information screen opens, select the Manage tab.
e) On the Manage tab, select the Endpoint Firmware Download command. f) Under Module Firmware dropdown, select the imported firmware version. g) Select Firmware Activation as Immediately. h) Click on the Send button to begin the Firmware Download process. Once completed, the Firmware Download event will be visible on the History tab of the Collector Radio Endpoint Information screen.
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 15
DEFECTS RESOLVED Fixes contained in this maintenance release are:
Command Center TFS Ticket
ID CRM Ticket ID Title
251742 While creating a new Alarm Definition for Commercial Gas Meters, the Command Center was showing multiple entries for Gas in the Meter Type dropdown. (RF Mesh)
297204 CAS-207239 A new billing cycle was being created named 'useCurrentBillingCycle' and meters were being assigned via MultiSpeak when no billing cycle information was sent in the web service.
310524 Removed "auto-baud" features that caused delays in the Mobile Administration Software (MAS) connecting to PLC/PLX meters.
445195 CAS-268873 The Phase Voltage Report was displaying Voltage Deviation Threshold and Current Imbalance Threshold incorrectly. (RF Mesh)
445204 CAS-264308 The Daily Usage Alert was not taking into consideration meter rollover based on numdials.
446487 Data Definitions were displaying as 'Undefined' in the Data Extract Setup when being added manually.
446895 While reconfiguring a PLX endpoint using the Endpoint Administration Software (EAS), the endpoint was being set to wink mode. (PLX)
473036 CAS-282473 The usage graph on the Endpoint Information screen was showing negative values when Gas modules reached a total beyond 9999 and rollover. (RF Mesh)
478232 CAS-289977 Users were not able to edit meter numbers for devices in Inventory status.
478726 CAS-288490 The user interface was timing out when trying to view Unassigned Meters from the Billing Cycles user interface.
482411 When redeploying a RF Mesh IP endpoint after deleting it from the system, the device was not transitioning to Normal status after receiving the InitPush. (RF Mesh IP)
487296 CAS-295885 The Last Reading timestamp on the Endpoint Information screen was not displaying the last read date and time for Commercial Gas meters. (RF Mesh)
493326 CAS-289813 The Initial Read was not being saved for Gas meters upon an import of the Installation Data file. (RF Mesh)
Landis+Gyr
16 98-1890 Rev AA Command Center 7.0 MR2
TFS Ticket ID
CRM Ticket ID Title
501119 CAS-299695 The navigation drop down menu on the Setup-->Collector's grid was not allowing users to select other pages.
501179 CAS-299763 Stored Procedure optimizations to check for duplicate IP address generation. (RF Mesh IP)
501180 CAS-299671 When running an Endpoint Data Export, for a specific collector, the extract resulted in error.
502585 CAS-300105 In Endpoint Test Manager (ETM), when performing a Device Test using Multiple Meter Mode, the firmware versions were being displayed incorrectly. (RF Mesh)
504603 CAS-300958 Web service now allows multiple meter/program combinations to be sent in one web service call.
504625 CAS-301195 After selecting the Read Meter Table command, the user settings were displaying incorrectly by global region based on customer's license. (RF Mesh IP)
510806 CAS-305322-H1Z9W9
When issuing a broadcast command, it was taking an abnormal long time to return the expected counts on the user interface. (RF Mesh IP)
512694 CAS-301288 The incorrect date and time were being returned via the CIM 2nd Edition interface when an 'Unexpected Demand Reset' event occurred.
513245 CAS-302334 Deleting a RF Mesh G5i Router from the Command Center user interface was resulting in an invalid meter number. (RF Mesh)
515013 CAS-305325-Q7K3Y1
The Current Neighbor was not shown on the Endpoint Information screen for any RF Mesh IP device. The layer for all devices was shown as Layer 1. (RF Mesh IP)
515342 CAS-300068 Gyrbox values on the FOCUS AX and FOCUS AXe were displayed incorrectly. They were being displayed as D1, D2, D3 were the actual settings for the D5, D6, D7 and vice versa. (RF Mesh)
515460 When issuing a 'Get Load Profile' command to an Elster REXU meter, requesting load profile set 1, the display was returning load profile set 2 information. (RF Mesh)
515474 An error was returned in the Endpoint Administration Software (EAS) when synchronizing Remote Service Switch transactions. (PLC/PLX)
516059 520529 532182
CAS-295437 CAS-304897-Z7D0Q2 CAS-304976-X4H3F1
A third-party penetration testing identified a cyber-security vulnerability whereby an attacker can manipulate the “Change Password” screen in Command Center in such a way it exposes a vulnerability that enables the cyber-attacker to change other users’ passwords (including the privileged administrator accounts). Please reference Product Information Letter, publication number 98-1945 Rev AA, for more information.
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 17
TFS Ticket ID
CRM Ticket ID Title
517770 CAS-300989 Support for Bolivia time zone. 518914 The 'Get Load Profile' command was not working properly for RF
Residential electric meters. (RF) 519262 The CBC8000 Series 4 Capacitor control was seeded with the
wrong Minor ID. (RF Mesh) 519918 CAS-303751 Optimization of the 'GetKeysBatch' sproc to ensure optimal
performance. 521136 RF Mesh Two-Way Water Stack Overflow event was being
processed in Command Center with eventID of 24 and should have been eventID 2. (RF)
523647 CAS-304898-M2K2R3
The Command Center server had stack traces enabled, which provides an attacker with a bit of information leakages as to how the application works internally. Stack traces were disabled.
523691 CAS-304963-V7Q3J0
XML eXternal Entity (XXE) error in XML templates import was allowing to insert DTD scheme in XML document which leads to DoS/SSRF/scan DMZ network.
524524 CAS-304977-L7Q7P9
Once a user had Command Center authentication, the Command Center would try to load any URL provided in the query string, resulting in a vulnerability to open redirection attacks in the headend.
524870 CAS-304978-N0J5F7
The Command Center server was failing to protect sufficiently against click-jacking attacks due to it not setting the X-Frame-Options headers.
525017 The Installation Data import file for Residential Gas meters was checking for the Reinstalled Meter Reading as an integer rather than a decimal format. (RF Mesh)
528715 CAS-306113-P1P3T1
Power Outage and Restore events were not being encrypted while in Advanced Security mode. (RF Mesh IP)
528721 CAS-306114-G1Q5S2
User sessions were not being terminated after a user's account was locked out.
529959 The Power Factor being reported in Command Center was a value derived from pulse counting when it should have been corrected by interval time (12/100 when interval time is 5 minutes or 6/100 when interval time is 10 minutes), this was due to calculation in the ABNT adapter. (RF Mesh IP, Brazil)
531592 CAS-304757 The 'Get Load Profile' command response was sending the same number set, even though other sets were requested. (RF Mesh IP, Brazil).
536122 Instantaneous reading values, returned through the CIM 2nd Edition interface through the ABNT Adapter, were missing the first byte of the packet. (RF MESH IP, Brazil)
Landis+Gyr
18 98-1890 Rev AA Command Center 7.0 MR2
Integration TFS Ticket
ID CRM Ticket ID Title
532909 Corrected inconsistency between CIM 2nd Edition header and payload date/time format. If the Zulu date/time format is selected for CIM 2nd edition, then that date/time format is used in the header, as well as the payload.
532922 525454 496638
CAS-285415
MultiSpeak ‘ODEventNotification’ for outage/restore messages were sending time with an hour difference.
534516 CAS-296802 Add CIM 2nd edition Reading types – Refer to table below. 519588 Add CIM 2nd edition Water Reading type – Refer to table below. 515361 CAS-302477 Load Profile readings returned through CIM 2nd edition interface
was coming in with ABNT command 52 only and missing some parts of this command. (Brazil)
515392 CAS-302667 CIM 2nd Edition Instantaneous FK7 Read was missing command #14 in the first byte. (Brazil)
506293 CAS-301241 ABNT METERS ONLY: CIM 2nd Edition Event IDs for Events 5167 (Meter Power Outage) and 5168 (Meter Power Restore) were UPDATED to 4.26.0.85 and 4.26.0.216 respectively. (Brazil)
515392 CAS-302667 CIM 2nd Edition Instantaneous FK7 Read was missing command #14 in the first byte.
506293 CAS-301241 ABNT METERS ONLY: CIM 2nd Edition Event IDs for Events 5167 (Meter Power Outage) and 5168 (Meter Power Restore) were UPDATED to 4.26.0.85 and 4.26.0.216 respectively.
503877 CAS-300057 Add CIM 2nd edition Event IDs – Refer to CIM tables below. 492864 Ensured CIM 2nd edition request for ping
(0.0.0.0.0.1.11.0.0.0.0.0.0.0.0.0.109.0) was responding with same reading type ID.
454943 CAS-278526 Meter Exchange functionality via Import Installation File and MultiSpeak ‘MeterExchangeNotification’ web service did not Deprovision HAN devices.
525959 CAS-304932 CIM 2nd edition – Database meter reading request with multiple meters in single request was not completing when meters in the request were in inventory or had no readings.
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 19
CIM 2nd Edition Event ID Updates The following CIM 2nd Edition Event IDs were assigned in Command Center 7.0 MR2:
Event CIM 2nd Ed
Event ID Event Detail
Error occurred while assigning a SoftID to the meter 3.7.10.79
Measurement error detected 3.21.67.79
Nonvolatile memory failure detected (Gas) 4.21.72.85
RF Gas Interval sensor fail 4.21.59.85
RF Gas Interval sensor fail flag 4.21.59.85 FLAG
RF Gas Nvram corrupt 4.18.72.43
RF Gas Nvram corrupt flag 4.18.72.43 FLAG
RF Gas Oscillator stop 4.21.93.243
RF Gas Oscillator stop flag 4.21.93.243 FLAG
RF Gas Sensor fail 4.21.84.85
RF Gas Sensor fail flag 4.21.84.85 FLAG
RF Gas Stuck sensor switch 4.21.84.270
RF Gas Stuck sensor switch flag 4.21.84.270 FLAG
RF Gas System error 4.18.0.177
RF Gas System error flag 4.18.0.177 FLAG
RF Water Interval sensor fail 24.21.59.85
RF Water Interval sensor fail flag 24.21.59.85 FLAG
RF Water Nvram corrupt 24.18.72.43
RF Water Nvram corrupt flag 24.18.72.43 FLAG
RF Water System error 24.18.0.177
RF Water System error flag 24.18.0.177 FLAG
Landis+Gyr
20 98-1890 Rev AA Command Center 7.0 MR2
Event CIM 2nd Ed
Event ID Event Detail
ROM failure detected 3.18.92.85
Checksum Error In Flash Memory 3.18.42.43
Cold Start 3.21.0.31
Configuration error detected 3.7.0.79
Demand overload detected 3.8.261.139
Error In Flash Memory 3.18.42.79
Excessive leading current detection started - Phase A 3.26.380.242
Excessive leading current detection started - Phase B 3.26.381.242
Excessive leading current detection started - Phase C 3.26.382.242
Out Of Calibration 3.21.18.40
Potential Neutral Lost 3.26.79.47
Potential Phase A Lost 3.26.126.47
Potential Phase B Lost 3.26.134.47
Potential Phase C Lost 3.26.135.47
RF Gas Consumption modified 4.20.87.24
RF Gas Consumption modified flag 4.20.87.24 FLAG
RF Gas Cut lead (renamed Failed Communication Error) 4.1.111.85 RF Gas Cut lead flag (renamed Failed Communication Error
flag) 4.1.111.85 FLAG
RF Gas Sensor Overload Channel 1 4.50.144.40
RF Gas Sensor Overload Channel 1 Flag 4.50.144.40 FLAG
RF Gas Sensor Overload Channel 2 4.51.144.40
Landis+Gyr
Command Center 7.0 MR 2 98-1890 Rev AA 21
Event CIM 2nd Ed
Event ID Event Detail
RF Gas Sensor Overload Channel 2 Flag 4.51.144.40 FLAG
RF Gas Sensor Stuck Channel 1 4.50.144.88
RF Gas Sensor Stuck Channel 1 Flag 4.50.144.88 FLAG
RF Gas Sensor Stuck Channel 2 4.51.144.88
RF Gas Sensor Stuck Channel 2 Flag 4.51.144.88 FLAG
RF Gas Watch dog 4.1.370.215
RF Gas Watch dog flag 4.1.370.215 FLAG
RF Water Watch dog 24.1.370.215
RF Water Watch dog flag 24.1.370.215 FLAG
Self check error detected 3.21.100.79
Temperature Threshold Exceeded Error 3.35.0.40
Time Adjustment Error 3.36.115.79
Time Synchronization 3.36.116.58
Unexpected Load Side Voltage 3.26.38.270
Unprogrammed 3.7.0.160 ABNT: Event ID 5167 UPDATED
Meter Power Outage 4.26.0.85 ABNT: Event ID 5168 UPDATED Meter Power Restoration 4.26.0.216
Landis+Gyr
22 98-1890 Rev AA Command Center 7.0 MR2
CIM 2nd Edition Reading Type ID Updates The following CIM 2nd Edition Reading Type IDs were assigned in Command Center 7.0 MR2:
Reading Type Description Data Definition ID CIM 2nd Edition
Present kWh Sum (Del + Rcvd) 304 0.0.0.1.20.1.12.0.0.0.0.0.0.0.0.3.72.0
Instantaneous Voltage Line A to Neutral Fund + Harmonics MOM
372 0.0.15.0.0.1.54.0.0.0.0.0.0.0.129.0.29.0
Instantaneous Voltage Line B to Neutral Fund + Harmonics MOM
374 0.0.15.0.0.1.54.0.0.0.0.0.0.0.65.0.29.0
Instantaneous Voltage Line C to Neutral Fund + Harmonics MOM
376 0.0.15.0.0.1.54.0.0.0.0.0.0.0.33.0.29.0
Load Side Phase A Voltage 2539 0.0.15.0.0.1.0.0.0.0.0.0.0.0.129.0.0.0
Load Side Phase C Voltage 2540 0.0.15.0.0.1.0.0.0.0.0.0.0.0.33.0.0.0
Present kWh Total Del - Rcvd Fund + Harmonics 930 0.0.0.1.4.1.12.0.0.0.0.0.0.0.0.3.72.0
Water 6100 0.0.0.0.0.9.0.0.0.0.0.0.0.0.0.0.128.0