Pine Decid. BUILDER'S RESPONSIBILITY TO LAYOUT WORK...rezoned from rs-1 to cd via rez2016-00005...
Transcript of Pine Decid. BUILDER'S RESPONSIBILITY TO LAYOUT WORK...rezoned from rs-1 to cd via rez2016-00005...
U D
U
D
U
D
DINING LIVING
DININGLIVING
DINING
LIVING
FRONT PORCH
COVERED DECK
COVERED DECK
SUNKEN PATIO
SUNKENPATIO
KITCHENKITCHEN
KITCHEN
FRONT PORCH
FRONT PORCH
Pine
Decid.
MultistemmedDeciduous
Decid.
SITE PLANZONING ANALYSIS
A1.0
GUTTER
CURB
CONCRETE SIDEWALK
227.5231.6
LP:227.50
LP:231.62
27
'-0
"64
'-0
"25
'-0
"20
'-0
"4'-
0"
5'-0"50'-0"5'-0"
15'-0"30'-0"15'-0"
MAIN FLOORELEV. 225.75'
E
NW
WSW
S SE
N NE
N
BLDG GRADE 219.429 B
LDG G
RADE 223.228
BLD
G G
RADE 2
31.8
00BLD
G G
RADE 227.800
E 223.9F 223.5
E 224.3
F 224.0
E N
/A
F 224
.5E N
/A
F 224
.0
E 224.4
F 224.0
E N/A
F 216
.25
E N
/AF 216.25
E 2
23.1
F 223
.0
E 2
23.9
F 223
.5 E 2
24.3
F 224
.0
E 223.9
F 225.5
E 223.9F 223.5
TW 221.5BW 219.2
TW 223.1BW 222.3
TW 223.1BW 219.6
TW 225.5BW 223.9
TW 227.5BW 223.8
TW 227.5BW 226.6
TW 223.3BW 222.8
TW 224.4BW 223.6
TW 226.4BW 224.5
TW 227.7BW 224.5
TW 230.7BW 227.9
TW 229.6BW 226.8
TW 229.3BW 226.8
GA
RB
AG
E
GA
RB
AG
E
CUTBACKWALL
EXTENDWALL
31
1 W
es
t 1
4th
2 S
TO
RE
Y D
WE
LL
ING
32
7 W
es
t 1
4th
1 S
TO
RE
Y D
WE
LL
ING
OUTLINE OF MAIN
OUTLINE OF UPPER
37
'-1
1"
16
'-4
5/8
"
2'-
10
3/4
"2
4'-
3"
27
'-2
"
8'-0" 24'-0" 18'-0"
26'-6"23'-6"
TRIPLE CARGARAGE
F 223
.75
F 225.75
F 225.75
10' R
ADIU
S
LOW
EST FIN
.
GRAD
E
1 2 3
9'-6"
2'-
0"
5'-
0"
RE
CY
CL
ING
RE
CY
CL
ING
REFER TO ROOF PLANFOR FURTHER
PROJECTIONS ANDOVERHANGS
SCALE 1/8"=-1'-0"
LOT AREA 8401 SQ FT
SLAB ELEV.222.5'
SLAB ELEV.220.5'
RE
CY
CL
ING
BIKE PARKING
SLAB ELEV.221.5'
PROPOSED METER BASES
8'-
8 3
/8"
2.6
5 m
LIM
ITIN
GD
IST
AN
CE
25
'-0
"
7.6
2 m
LIM
ITIN
GD
IST
AN
CE
3'-11 1/4"
EXTENT OF O/H ABOVE - MAX PROJECTION SHOWN
3'-11 1/4"
EXTENT OF O/H ABOVE - MAX PROJECTION SHOWN
48
' F
IRE
FIG
HT
ER
AC
CE
SS
31' F
IRE F
IGHTER
ACCESS
56
' F
IRE
FIG
HT
ER
AC
CE
SS
4'-0"
4'-0
"
4'-0"
4'-0"
5'-0"
1.52 m LIMITING DISTANCE
5'-0"
1.52 m LIMITING DISTANCE
68
'-0
" 2
0.7
3 m
LIM
ITIN
G D
IST
AN
CE
TO
CL
OF
WE
ST
14
TH
10
0%
UN
PR
OT
EC
TE
D O
PE
NIN
G A
LL
OW
ED
UNIT 3
UNIT 2
UNIT 1
LEGAL DESCRIPTION: LOT 8 BLOCK 64DISTRICT LOT 271 AND 548 GROUP 1 NWD
PLAN 750
PID 015-142-990
CONFORMANCE TO 9.32 - INDIVIDUAL UNITS TO CONTAIN HRV UNITS
- REFER TO A4.3 FOR COMPLETE INFORMATION
CONFORMANCE TO 9.36 - PRESCRIPTIVE REQURIEMENTS 9.36.2 -
9.36.4, REFER TO A4.0 FOR COMPLETE INFORMATION
REZONED FROM RS-1 TO CD VIA REZ2016-00005
CONC.UNIT
PAVERS
CONC.UNIT
PAVERSLAWN
CL OF LANE
EXG
. 222
.6'
FIN. 2
22.2
8'
EXG. 222.28'
FIN. 222.28'
EXG
. 220.6'
FIN. 220.38'
EXG
. 220
.38'
FIN. 2
20.3
8'
ELEV. 219.2
ELEV
. 222.9
ELEV
. 220.8
20
0 m
m S
TO
RM
CO
NN
EC
TIO
N
RE
FE
R T
O C
IVIL
DW
G
10
0 m
m S
AN
I. C
ON
NE
CT
ION
RE
FE
R T
O C
IVIL
DW
G
19
mm
WA
TE
R C
ON
NE
CT
ION
RE
FE
R T
O C
IVIL
DW
G
LAWN
CHARACTER SKETCH FRONT
GENERAL CONSTRUCTION / SECTION NOTES
FOOTING / FOUNDATION NOTES:
1. ALL FOOTINGS TO BE MIN. 18" BELOW GRADE2. REFER TO STRUCTURAL DRAWINGS FOR ALL FOOTING SIZES AND REINFORCEMENT3. PERIMETER DRAINAGE TO BE 4" PERFORATED PVC PIPE - HOLES DOWN - PACKED IN MIN. 6" DRAIN ROCK AND WRAPPED IN LANDSCAPE FABRIC4. NOT USED5. WHERE STRUCTURAL SLAB MEETS WALL USE MOISTURE BARRIER AS A BOND BREAK6. ALL RAIN WATER LEADERS TO BE VIA 4" SOLID WALL PVC LED TO SUMP AS REQ'D7. NOT USED
TOP OF FOUNDATION WALL NOTES:
1. ALL GRADE AT FOUNDATION WALL TO BE FINISHED TO FORM NOMINAL SLOPE FROM FOUNDATION WALL2. WHERE ADJACENT GRADE IS HARD SURFACE, MIN. DISTANCE TO FINISHES IS 2"3. WHERE ADJACENT GRADE IS EARTH OR OTHER, MIN. DISTANCE TO FINISHES IS 8"4. SILL PLATE TO BE PRESSURE TREATED (FASTENERS TO BE COMPATIBLE)5. SILL IS SET ON SILL GASKET6. ALL WOOD IN CONTACT W/ CONC. TO BE PRESSURE TREATED OR BE SEPERATED FROM CONC. BY BUILDING PAPER OR AIR SPACE.7. ANCHOR BOLTS AND HOLD DOWN REGIME AS PER STRUCTURAL DRAWINGS8. ALL HOT DIPPED GALVINIZED FASTENERS TO BE USED FOR EXTERIOR EXPOSED APPLICATIONS
WALL FLASHING AND INTERSECTION NOTES:
1. ALL WALL ROOF INTERSECTIONS SHALL BE PROVIDED WITH FLASHING2. WHERE SKIRT ROOFS ARE PRESENT - INSTALL MIN. 1 LAYER 30 MIN. BUILDING PAPER PRIOR TO INSTALL OF JACK/SKIRT STRUCTURE3. FLASHING REFERRED TO ABOVE SHALL BE PLACED ON FLASHING PAPER4. FLASHING REFERRED TO ABOVE SHALL RETURN UP WALL MIN. 2" AND HAVE 2 LAYER 30 MIN. FIELD BUILDING PAPER LAPPED OVER5. PRESSURE TREATED BATTENS OR DRAINAGE MAT SHALL BE HELD BACK FROM THE TOP OF FLASHING6. IF PRESSURE TREATED VERTICAL BATTENS ARE USED - INSTALL INSECT SCREEN STAPLED FIRST AND WRAPPED TAUT OVER BATTENS
GENERAL RAINSCREEN NOTES:
1. ALL BOTTOM OF WALL CONDITIONS SHALL BE VENTED.2. RAINSCREEN SHALL BE PROVIDED BY 3/4" PRESSURE TREATED VERTICAL BATTENS MAX 12" OC OR APPROVED DRAINAGE MAT.3. REGARDLESS OF PROVISIONS FOR THE DRAINAGE CAVITY, CORNERS AND ABUTMENTS TO WINDOWS AND DOORS SHALL BE DONE W/ PRESSURE TREATED VERTICAL BATTENS TO PRODUCE CLEAN CORNERS ETC.4. ALL WALL PENETRATIONS FOR LIGHTS, VENTS AND OTHERS SHALL BE AUGMENTED BY A WOOD BLOCK SET ON PEEL AND STICK AND FLASHED AS PER WINDOW PENETRATIONS.
ROOF AND SOFFIT NOTES:
1. ALL ROOFING TO BE INSTALLED TO RCABC GUARANTY STANDARDS2. NOT USED.3. FOR VENTILATION REFER TO ROOF PLAN / ASSUME CONTINUOUS 1 1/2" STRIP VENT IN ALL SOFFIT LOCATION4. NOT USED.5. NOT USED7. INSTALL FLASHING AT EAVE DRIPS AS PER RCABC8. EAVES TROUGH TO BE EXTRUDED ALUMINUM SECTION - FINAL COLOURS AND PROFILE TO BE DETERMINED9. SET EAVES TROUGHS ON 2x GUTTER FASICAS10. SOFFIT MATERIAL TO BE 1x4 V-JOINT CEDAR UNLESS NOTED OTHERWISE11. NOT USED.
WINDOW NOTES
1. DIMENSIONS INDICATED REPRESENT ROUGH OPENINGS (WIDTHxHEIGHT). CONFIRM FINAL ROUGH OPENINGS & INSTALLATION REQUIREMNETS WITH MANUFACTURER.2. NOT USED.3. GLAZING IN DOORS, SIDELIGHTS & WINDOWS WITHIN 36" OF EXTERIOR DOOR LOCKSETS, BATHTUBS OR SHOWERS TO BE SAFETY GLASS.4. BEDROOM WINDOW OPENINGS TO MEET BCBC 2012 REQUIREMENTS FOR EGRESS.5. HANDLE AND INSTALL WINDOWS AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.6. WINDOWS TO BE THERMALLY-BROKEN ALUMINUM, U.N.O.
GENERAL REQUIREMENTS
STANDARDS AND MANUFACTURER'S LITERATUREl:
1. It is intended that this project shall meet the requirements of the BCBC 2012, and CMHC Building Standards, latest editions, in all respects and Municipal Building Regulations.2. In the absence of other standards being required by the Contract Documents, all work is to conform to, or exceed, the minimum standards of the Canadian Government Specifications Board, the Canadian Standards Association, the VBBL, the Workers' Compensation Board of British Columbia, and manufacturers of materials supplied for this project, whichever is/are applicable.
SAFETY REQUIREMENTS:
1. Observe and enforce all construction safety measures by the Canadian Construction Safety Code supplemented by the BCBC 2012, applicable WorksafeBC requirements, and local statutes and By-laws.
PROTECTION OF PUBLIC WORK AND PROPERTY:
1. Adequately protect all work unaffected by the work, completed or in progress. Any work damaged or defaced due to failure to provide such protection shall be removed and replaced or repaired as directed by the Consultant at no increase in the Contract Price.2. Prevent overloading of any part of the building. Do not cut, drill or otherwise sleeve any load-bearing structural member without written approval of the Consultant.3. The Contractor shall assume responsibility for any damage to existing paving, walks, adjacent building and property, services, etc. caused by construction operations. He shall repair and make good same, or bear the expense of such repairing.
ADJACENT PROPERTY:
1. The Contractor shall conduct construction operations with minimum interference to adjacent property roadways, sidewalks, and access to facilities in general. Keep such areas free from materials, debris, and equipment at all times. Confine operations to areas designated by the Consultant and/or Owner. Maintain fire vehicular access to existing building at all times.2. Keep loud noises to a minimum only as necessary to conduct work. Loud music and swearing audible on adjacent properties is not acceptable.
SHOP DRAWINGS AND SUBMITTALS:
1. Submit to the Consultant for review, shop drawings for windows and doors and millwork or other items as specified herein or as requested by the Consultant.2. Throughout the duration of the Contract, whenever requested to do so by the Consultant, submit product samples and colour charts. This is of particular importance where materials are described in generic terms on the drawings.3. Until submission is reviewed, work involving relevant product may not proceed.4. Review shop drawings, product data and samples prior to submission.5. Submittals to include Contractor's stamp, initialed and signed, certifying review of submission, verifications of field measurements and compliance with the Contract Documents.6. The Contractor's responsibility for errors and omissions is not relieved by the Consultant's review of submittals.
LOCATION OF EQUIPMENT AND FIXTURES:
1. Location of equipment, fixtures and outlets indicated or specified are to be considered as approximate. Location of service runs, ducts, conduits, piping, suspensions systems, and other concealed items shown on drawings are diagrammatic.2. Locate equipment, fixtures and distribution systems to provide minimum interference and maximum usable space and in accordance with manufacturer's recommendations for safety, access, and maintenance.
CONCEALMENT:
1. Conceal pipes, ducts, and wiring in floor, wall and ceiling construction of finished areas except where otherwise indicated.
PROJECT RECORD DOCUMENTS:
1. As-Built Drawings: The Contractor shall keep one set of white prints of all contract drawings, Architectural, Interior Design, Structural, Mechanical, Electrical, Plumbing and Drainage, included addenda, revisions, clarifications, change orders and approved shop drawings in the site office and identify them as "As-Built drawings".
PROJECT CLOSE-OUT:
1. Disposal Requirements:Conduct cleaning and disposal operations to comply with codes, ordinances, regulations, and anti-pollution laws. Dispose of rubbish, debris and waste materials at periodic intervals away from the site and in a legal manner.2. Final Cleaning:Employ only skilled workers for final cleaning. Clean and polish glass, mirrors, hardware, wall tie, stainless steel, chrome, porcelain enamel, baked enamel, plastic laminate, mechanical and electrical fixtures. Remove stains, spots, marks and dirt from decorative work. Vacuum clean and dust all building interiors, carpets, behind grilles, louvres and screens. Clean, wax and seal or prepare all floor finished as recommended by the manufacturer.
GENERAL NOTES - ARCHITECTURAL:
1 All work shall conform to the standards of Section 9 of the BCBC 2012, all local codes, bylaws and amendments.2 Do not scale drawings. Dimensions always take precedence.3 The general contractor shall verify all datum's, dimensions and levels prior to commencement of work. Any errors, omissions or discrepencies to be discussed with the Architect.4 These drawings are the exclusive property of the Architect, and cannot be reproduced without the expressed written consent of the Architect.5 All work to be performed to current good trade practice standards by workmen skilled in their trades.6 All materials to be of good quality, properly transported, stored, and protected.7 All exterior dimensions taken from outside face of sheathing or exterior face of concrete and interior framing centre lines unless noted otherwise.
VENTILATION NOTES:
1. ALL WORK TO COMPLY WITH SECTION 9.32 OF THE BCBC 2012 (INCLUDING AMENDMENTS)2. ALL REGISTER AND APPLIANCE LOCATIONS ARE DIAGRAMMATIC WITHIN ROOMS. FINAL LOCATIONS TO BE COORDINATED WITH ON SITE STRUCTURE AND CEILING AND LIGHTING DESIGN3. ALL FUEL BURNING APPLIANCES SHALL BE HI EFFICIENY SEALED UNITS4. BUILDING IS NOT VENTILATED BY NATURAL MEANS THEREFORE TABLE 9.32.2.2 DOES NOT APPLY5. AN HRV IS BEING USED AS THE PRINCIPAL VENTILATION SYSTEM6. ALL DUCTING TO EACH BEDROOM AND TO EACH FLOOR WITHOUT A BEDROOM SHALL BE DEDICATED DUCTS7. SUPPLY AND EXHAUSTS ARE SHOWN AS MINIMUMS. THE CONTRACTOR MAY OPT FOR MORE, BUT NOT LESS - ENSURE THE HRV IS APPRORIATE FOR ANY INCREASE8. HRV/EXHAUST SYSTEM TO OPERATE CONTINUOUSLY9. HRV/EXHAUST SYSTEM TO BE OPERATED BY A DEDICATED SWITH WITH ON/OFF ONLY10. IF AN HRV SYSTEM IS DESIGNED TO RUN AT MULTIPLE AIR FLOW RATES - THIS CONTROL SHALL BE A SEPARATE SWITCH - ALL RATES MUST STILL MEET 56 L/s (119 CFM)11. HRV EXHAUST LOCATIONS TO BE NEAR TOP OF WALLS11. BATHROOM FANS TO BE MIN 23 L/s (49 CFM) IF INTERMITTENT OR 9 L/S IF CONTINUOUS12. KITCHEN FAN TO BE MIN. 47 L/s (100 CFM)13. ALL DUCTING TO BE AS PER MANUFACTURER'S SPECIFICATION, BUT SHALL MEET TABLE 9.32.3.8. (3)
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
PrivateDEVELOPMENT
321 West 14th StreetNorth Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
E D C B A
1
2
3
4
5
6
7
8
9
A
-
A
-
FOUNDATION
PLAN
A2.0
AS
SU
ME
D B
EA
M O
VE
R
ASSUMED BEAM OVER
ASSUMED BEAM OVERASSUMED SHEAR WALL ELEV. 216.75'
AS
SU
ME
D S
HE
AR
WA
LL
CL
EA
R C
RU
SH
EL
EV
. 2
19
.50
'
FD FD
FD FD
BASEMENT SLAB
ELEV. 216.75'
ELEV. 216.50'
ELEV. 216.75'
ELEV. 216.50'
ELEV. 216.75'
EL
EV
. 2
20
.25
'
CL
EA
R C
RU
SH
EL
EV
. 2
19
.50
'
EL
EV
. 2
20
.25
'
CL
EA
R C
RU
SH
EL
EV
. 2
19
.50
'
EL
EV
. 2
20
.25
'
CL
EA
R C
RU
SH
EL
EV
. 2
19
.50
'
EL
EV
.
22
0.2
5'
E 2
23.9
F 2
23.5
E 2
24.3
F 2
24.0
E N
/A
F 2
24.5
E N
/A
F 2
24.0
E 2
24.4
F 2
24.0
E N
/AF 2
16.2
5
E N
/AF 2
16.2
5
E 2
23.1
F 2
23.0
E 2
23.9
F 2
23.5
EL
EV
. 2
23
.17
'E
LE
V.
22
3.6
7'
EL
EV
. 2
24
.17
'
EL
EV
. 2
24
.17
'
ELEV. 223.50'
ELEV. 223.50'
ASSUMED SHEAR WALL ELEV. 216.75'
EL
EV
. 2
16
.75
'
EL
EV
. 2
16
.75
'
ELEV. 216.75'
EL
EV
. 2
16
.75
'
EL
EV
. 2
16
.75
'
EL
EV
. 2
16
.75
'
TOC. ELEV. 224.75'
TOC. ELEV. 224.75'
TOC. ELEV. 224.75'
TOC. ELEV. 224.75'
TOC. ELEV. 224.75'
TO
C.
EL
EV
. 2
24
.75
'
FD
SS
SS
FD
FD
SS
BATH
BATHBATH
TOC. ELEV. 225.41'
TOC. ELEV. 225.41'
TOC. ELEV. 225.41'
TOC. ELEV. 225.41'
TOC. ELEV. 225.41'
SLAB OVER
225.41'
SLAB OVER
225.41'
SLAB OVER
225.41'
SLAB OVER
225.41'
SLAB OVER
225.41'
BASEMENT SLAB
ELEV. 216.75'
BASEMENT SLAB
ELEV. 216.75'
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DSDS
DS
DS
54
'-3
5/8
"6
'-8
1/4
"3
'-8
"5
'-0
"
2'-
1 1
/8"
8'-
4"
4'-
6"
1'-
11
"1
'-1
1"
4'-3 1/2"
10
'-8
7/8
"1
1'-
4"
9'-
6"
11
"1
1"
4'-3 1/2"
3'-7 1/2"
3'-7 1/2"
5'-
5 3
/8"
4'-
11
5/8
"3
'-2
3/4
"5
'-0
"3
'-1
7/8
"
1'-1 1/2"
8'-
0"
27
'-0
3/4
"8
'-0
"
8'-
0"
4'-
10
1/8
"
3'-2"
2'-6"
1'-0"
5'-
0"
2'-0"
17
'-2
5/8
"5
'-0
"6
'-6
3/8
"8
'-4
"
8'-
0"
4'-
7 1
/2"
2'-0"
50'-0"
8'-0" 14'-6" 9'-6"
1'-1 1/2"
1'-4 5/8"
1'-
4 5
/8"
1'-
4 5
/8"
1'-4 5/8"
1'-4 5/8"
1'-
4 5
/8"
10'-10 3/4" 5'-4 1/2" 7'-8 3/4"
5'-
1 7
/8"
12
'-1
1 7
/8"
8'-
11
"
11
'-9
5/8
"1
2'-
11
7/8
"8
'-0
3/8
"4
'-1
5/8
"
13'-10"
50'-0"
13'-4" 9'-4" 11'-0"8"8" 8" 13'-4 7/8"
3'-
8"
1'-
6 7
/8"5
'-2
7/8
"
5'-
6 1
/8"
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
E D C B A
1
2
3
4
5
6
7
8
9
A
-
A
-
BEDROOM
DEN
BEDROOM
REC ROOMREC ROOM
REC ROOM
CELLAR FLOOR
PLAN
A2.1
2071 SQ FT
BATH
BATH
BATH
TILE
TILE
TILE
2/3
06
8
2/2668
266
8
266
8
2668
2668
266
8
266
82
66
8
2668
26682668
266
8
IHW /BOILER
IHW
/BO
ILE
R
IHW /BOILER
2/2
66
8
2/2
66
8
AC
TIV
E
AC
TIV
E
SUITE SEPARATON SUITE SEPARATON
SU
ITE
SE
PA
RA
TO
N
SD
SD
SD
SD
SD
SD
36
" H
AN
DR
AIL
/GU
AR
D
36
" H
AN
DR
AIL
/GU
AR
D
36" HANDRAIL/GUARD
UP 15 RI@ 7.20"
UP 13 RU@ 9.50"+ 1.5" NOSING
+ LANDING
UP 15 RI@ 7.20"
UP 13 RU@ 9.50"+ 1.5" NOSING
+ 2 LANDINGS
UP 15 RI@ 7.20"
UP 13 RU@ 9.50"+ 1.5" NOSING
+ 2 LANDINGS
266
8
403
0
ME
ET
EG
RE
SS
263
02
63
0
263
0
ME
ET
EG
RE
SS
403
0
ME
ET
EG
RE
SS
PR
IVA
CY
SC
RE
EN
FD FD
FD FD
SUNKEN
PATIO
SUNKEN
PATIO
1% SLOPE TYP.
1% SLOPE TYP.
E N
/A
F 2
24.0
E N
/AF 216.25
E N
/AF 216.25
UP 11 RI@ 7.64"
UP 9 RU@ 9.50"+ 1.5" NOSING
+ LANDING
UP 11 RI@ 7.64"
UP 9 RU@ 9.50"+ 1.5" NOSING
+ LANDING
ELEV. 216.50'
EL
EV
. 2
16
.50
'
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DS
DSDS
DS
E 223.9
F 223.5
E 2
23.1
F 2
23.0
E 224.4
F 224.0
E 223.9
F 223.5
E 2
24.3
F 2
24.0
E N
/A
F 2
24.5
DS
54
'-3
5/8
"
16
'-4
1/4
"3
7'-
11
3/8
"
6'-
3 1
/8"
17
'-2
1/8
"6
'-7
3/4
"7
'-1
0 3
/8"
8'-
2 1
/2"
5'-
0"
3'-
1 7
/8"
51
'-5
"
24
'-4
1/4
"2
7'-
0 3
/4"
10
'-8
3/8
"1
3'-
7 7
/8"
17
'-2
5/8
"5
'-0
"1
'-9
"3
'-1
"
2'-0"
1'-1 1/2"
17
'-6
"4
'-2
"4
'-2
7/8
"3
'-7
3/8
"9
'-1
1 3
/4"
3'-
0"
3'-
4 1
/2"
8'-
5 1
/8"
5'-
8 3
/4"
4'-
4 1
/2"
3'-
0"
2'-
4 1
/2"
11
'-7
"
50'-0"
14'-0" 9'-4" 8" 11'-0 7/8" 14'-0"
8'-
0"
6'-
8 1
/4"
3'-
8"
3'-
8"
1'-
6 7
/8"
3'-0"
3'-
0"
3'-0"
3'-
0"
3'-
2 1
/2"
3'-
0"
3'-0"
3'-0" 3'-0"
3'-
0"
7'-8 1/4"3'-7"14'-9 1/2"9'-8 5/8"2'-4 1/2"1'-5 7/8"10'-1 3/4"
4'-1 3/4"3'-7"5'-4 1/2"10'-10 3/4"
2'-9 3/4" 5'-5 1/2"
3'-9"
SDSMOKE DETECTOR HARD-WIRED AND
INTERCONNECTED
BATHROOM FAN
UNIT 3
UNIT 2
UNIT 1
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
E D C B A
1
2
3
4
5
6
7
8
9
A
-
A
-
30503050
30503050
DW
F
DW
F
DINING LIVING
DININGLIVING
DINING
LIVING
FRONT
PORCH
FRONT
PORCH
COVERED DECK
SUNKEN PATIO
SUNKEN PATIO
KITCHENKITCHEN
KITCHEN
MAIN FLOOR
PLAN
A2.2
2071 SQ FT
E 223.9
F 223.5
E 2
24.3
F 2
24.0
E N
/A
F 2
24.5
E N
/A
F 2
24.0
E 224.4
F 224.0
E N
/AF 216.25
E N
/AF 216.25
E 2
23.1
F 2
23.0
E 223.9
F 223.5
FINISH ELEV.
225.58'
EXTERIOR TILE FINISH
EXTERIOR TILE FINISH
42
" G
UA
RD
42
" G
UA
RD
223.50'
22
3.5
0'
22
3.5
0'
ELEV. 216.50'
EL
EV
. 2
16
.50
'
22
3.5
0'
22
3.5
0'
FINISH ELEV.
225.58'
223.58'4
2" G
UA
RD
42" GUARDDN 11 RI@ 7.64"
DN 9 RU@ 9.50"+ 1.5" NOSING
+ LANDING
DN 11 RI@ 7.64"
DN 9 RU@ 9.50"+ 1.5" NOSING
+ LANDING
FINISH ELEV.
225.58'
EXTERIOR TILE FINISH
FINISH ELEV.
225.58'
EXTERIOR TILE FINISH
UP 4 RI@ 6.24"
UP 3 RU@ 10.00"+ 1.5" NOSING
UP 4 RI@ 6.00"
UP 3 RU@ 10.00"+ 1.5" NOSING
42" GUARD
42" GUARD
42" G / HRAIL
42" G / HRAIL
224.00'
UP 3 RI@ 6.32"
UP 3 RU@ 10.00"+ 1.5" NOSING
224.00'
UP 3 RI@ 6.32"
UP 3 RU@ 10.00"+ 1.5" NOSING
224.00'UP 3 RI@ 6.32"
UP 3 RU@ 10.00"+ 1.5" NOSING
36
" G
UA
RD
36
" G
UA
RD
36
" G
UA
RD
36
" G
UA
RD
36
" G
UA
RD
BACK
VENT D/V
GAS F/P
POWDER
TILEPOWDER
TILE
POWDERTILE
DN 15 RI@ 7.20"
DN 13 RU@ 9.50"+ 1.5" NOSING
+ LANDING
36" GUARD
UP 16 RI@ 7.50"
UP 14 RU@ 9.50"+ 1.5" NOSING
+ LANDING
DN 15 RI@ 7.20"
DN 13 RU@ 9.50"+ 1.5" NOSING
+ LANDING
UP 16 RI@ 7.50"
UP 14 RU@ 9.50"+ 1.5" NOSING
+ LANDING
DN 15 RI@ 7.20"
DN 13 RU@ 9.50"+ 1.5" NOSING
+ LANDING
UP 16 RI@ 7.50"
UP 14 RU@ 9.50"+ 1.5" NOSING
+ 2 LANDINGS
307
0
307
0
307
0
2/2
07
0
2/2
67
0
2/2
67
0
2670
2670
2670
2/2
07
0
TOP
VENT D/V
GAS F/P
TOP
VENT D/V
GAS F/P
SAFETY
W
D
3/3070
3/3070
F
DW
FOYER
FOYER
FOYER
307
0
3050 3050
20362036
203
62
03
6
ELEV. 225.75'
ELEV. 225.75'
ELEV. 225.75'
203
6
FRONT PORCH
FINISH ELEV.
225.58'
EXTERIOR TILE FINISH
HATCHED AREA
DENOTES UNVENTED
R28 ABOVE
HATCHED AREA
DENOTES UNVENTED
R28 ABOVE
DS
DS
DSDS
DS
DS
DS
DSDS
DS
DS
DS
DSDS
DS
65
'-1
1 7
/8"
6'-
8 1
/4"
37
'-1
1 3
/8"
4'-
11
5/8
"1
1'-
3 5
/8"
5'-
1"
3'-
9 1
/8"
5'-
0"
19
'-4
5/8
"6
'-5
1/8
"3
'-4
3/8
"
64
'-5
"
8'-
0"
27
'-0
3/4
"8
'-0
"1
6'-
4 1
/4"
5'-
0"
4'-
10
1/8
"5
'-0
"1
7'-
2 5
/8"
10
'-7
"5
'-9
1/4
"8
'-0
"
50'-0"
8'-0" 24'-0" 18'-0"
3'-3 1/4" 4'-8 3/4" 8'-1 1/2" 11'-1 1/2" 4'-9" 6'-3"4'-3"5'-10 1/2"1'-7 1/2"
2'-
0"
9 1
/4"
3'-
0"
2'-0"5'-6"2'-0"
2'-
0"
9 1
/4"
6'-
0 3
/4"
2'-0"8'-4 1/2"2'-0"
2'-0" 6'-0"
8'-
2 1
/2"
5'-
0"
3'-
1 7
/8"
1'-1 1/2"
1'-1 1/2"
2'-0"
4'-6 1/4" 2'-9 3/4" 16'-4 3/4" 7'-11 1/2" 5'-6" 12'-9 3/4"
4'-9 3/4" 1'-0" 2'-5 1/2" 16'-0" 7'-8 3/4"
2'-8 3/4"
3'-8 3/4"
6'-
8 3
/4"
6'-
10
1/2
"2
'-9
"6
'-4
3/8
"6
'-9
1/2
"4
'-5
1/4
"5
'-2
"1
5'-
2 1
/8"
2'-
10
5/8
"
5'-
8 3
/4"
5'-
2 3
/4"
7'-
4 1
/2"
13
'-1
1 1
/2"
50'-0"
24'-0" 26'-0"
14'-0" 15'-0"11'-0"10'-0"
7'-0" 11'-8 3/8" 5'-3 5/8" 5'-9 3/4" 12'-1 3/4" 8'-0 1/2"
3'-0"
3'-
0"
3'-0" 3'-2 1/2"
3'-
0"
3'-
2 1
/2"
3'-
0"
3'-0"
1'-6"5'-0"1'-6"
5'-0"
5'-0"
4'-6"5'-0"4'-6"
3'-
0"
3'-0"
3'-
0"
COVERED DECK
5'-0"4'-6" 4'-6"
SD
SD
SD
36
" H
/RA
IL
36" H/RAIL
36
" H
/RA
IL
36
" H
/RA
IL
36" H/RAIL/GUARD
36" H/RAIL/GUARD
UNIT 3
UNIT 2
UNIT 1
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
E D C B A
1
2
3
4
5
6
7
8
9
A
-
A
-
DN 16 RI@ 7.50"
DN 14 RU@ 9.50"+ 1.5" NOSING
+ LANDING
2640
203
6
304
03
04
0
2640
30403040
30403040
DDDD
BALCONY
BALCONY
MASTER
BEDROOM
MASTER
BEDROOM
MASTER
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
SECOND
FLOOR PLAN
A2.3
2102 SQ FT
ENSUITE
ENSUITE
ENSUITE
BATH
TILE TILE
BATH
TILE
BATH
TILE
LAUNDRY
TILE
W
D
W
D
LAUNDRY
TILE
ELEV. 285.75'
ELEV. 285.75'
FIN. ELEV. 285.50'
FIN. ELEV. 285.50'
42" GUARD
DDDD
2/2
66
8
AC
TIV
E
42" GUARD
2/2
66
8
AC
TIV
E
2640 2640
203
6
264
0
264
0
SD
SD SD
TILE
TILE
SD SD
SD
SD
SD
SD
SD
SD
SD
266
8
206
8
2/3
07
02
/306
8
2/2668
266
8
2670
266
8
2/2
06
8
286
8
2668
2668
266
8
266
8
266
8
266
82
66
8
2/2
66
8
2/3068
2668
2668
2668
2/2068
266
8
266
8
2668
2630
36
" G
UA
RD
36" GUARD
36
" H
RA
IL/G
UA
RD
36" HRAIL/GUARD
36" HRAIL
4:1
2
4:124:12
4:12 4:12
4:124:12
4:12
2036
2640
2640 2640
264
0
103 SQFT ATTIC
VENTED BELOW
@1/300
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
DSDS
DS
DS
DS
DS DS
DS
DN 16 RI@ 7.50"
DN 14 RU@ 9.50"+ 1.5" NOSING
+ LANDING
DN 16 RI@ 7.50"
DN 14 RU@ 9.50"+ 1.5" NOSING
+ 2 LANDINGS
57
'-3
5/8
"
2'-
10
5/8
"
7'-
4 1
/8"
24
'-8
5/8
"
32
'-0
3/4
"2
2'-
4 1
/4"
2'-
4 5
/8" O
FF
SE
T
17
'-8
3/4
"1
4'-
4"
57
'-3
5/8
"
32
'-2
3/4
"2
5'-
0 7
/8"
8'-
7 7
/8"
18
'-1
0"
4'-
9"
11
'-7
"1
3'-
5 7
/8"
50'-0"
12'-4 1/2"5'-7 1/2"24'-0"8'-0"
4'-7"
16'-1 1/2" 8'-7 1/4" 7'-3 1/4"
50'-0"
26'-0"24'-0"
6" 13'-0" 10'-6"
5'-3 5/8"6'-6"
13'-0" 1'-6"11'-6"
5'-9 3/4" 7'-6 3/4" 4'-7 1/2" 4'-7 1/2" 3'-4 1/2"
4'-
4 1
/2"
4'-
4 1
/2"
9'-8 3/4" 2'-4 1/2" 3'-4 1/2" 4'-6" 10'-11 1/4"4'-9 1/2" 3'-5 1/2" 6'-7" 3'-4 1/2"
10 1/2"
4'-6 1/4" 7'-7" 4'-10 1/2" 6'-9" 5'-5 1/2" 6'-5" 12'-0 1/4"2'-4 1/2"
5'-6 1/4" 2'-0" 3'-4 1/2" 3'-4 1/2" 1'-11 1/2" 1'-11" 5'-10 1/4"
12
'-3
1/2
"3
'-1
0 7
/8"
3'-
11
5/8
"4
'-3
"8
'-1
"
2'-
4 1
/2"
2'-
4 1
/2"
9'-
11
1/4
"8
'-8
3/4
"
3'-10 1/2" 2'-4 1/2" 12'-0 1/4"
ROOF VENT
ROOF VENT
UNIT 3
UNIT 2
UNIT 1
HRV UNIT
OVER
HR
V U
NIT
OV
ER
HRV UNIT
OVER
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
E D C B A
1
2
3
4
5
6
7
8
9
A
-
A
-
ROOF PLAN
A2.4
12:1212:12
7.5:127.5:12
CR
ICK
ET
METAL V
ALLEY
METAL VALLEY
METAL V
ALLEY
7.5:12 7.5:12
CR
ICK
ET
+/-
5.8
:12
+/-
5.8
:12
+/-
10
.2:1
2
PROVIDE CONTINUOUS ROOF VENTING
AREA OF SECOND FLOOR 2102 SQ FT TO
BE ATTIC VENTED @ 1/300
PROVIDE 7.00 SQ FT TOTAL VENTING
PROVIDE MIN. 1.75 SQ FT @ RIDGE
PROVIDE MIN. 1.75 SQ FT @ EAVES
CONTRACTOR TO PROVIDE RIDGE
VENTS ON ALL RIDGES TO ALLOW FOR
ATTIC SEPARATION OF SUITES
TOTAL RIDGE LENGTH +/- 25'
TO
TA
L R
IDG
E L
EN
GT
H +
/- 1
4'
TO
TA
L R
IDG
E L
EN
GT
H +
/- 3
5'
PR
OV
IDE
CO
NT
INU
OU
S R
OO
F V
EN
TIN
G
PR
OV
IDE
CO
NT
INU
OU
S R
OO
F V
EN
TIN
G
DS
DS
DS
DS
DSDS
DS
DS DS
DS
3'-
0"
1'-0" 1'-0" 2'-0" 2'-0"
3'-
0"
3'-
0"
1'-0"
1'-
7 1
/2"
1'-
7 1
/2"
11 1/4"
3'-
0"
1'-6 5/8"
1'-7 1/2"
1'-
6"
1'-
6"
1'-7 1/2"
2'-1 1/2"
1'-7 1/2"1'-7 1/2"
1'-
7 1
.2"
3'-
0"
1'-10"1'-10"
1'-0" 1'-0"
11 1/4"
1'-6 5/8"
7.5:12
1'-0"
1'-6 5/8"
3'-
0"
OVERHANGS ARE NOT
EQUAL - OFFSET HIP TO
ALLOW FOR 1'-0" MAX
PROJECTION - NO ROOF
PROJECTIONS WITHIN 4'-0"
OF SIDE PROPERTY LINES
OVERHANGS ARE NOT
EQUAL - OFFSET HIP TO
ALLOW FOR 1'-0" MAX
PROJECTION - NO ROOF
PROJECTIONS WITHIN 4'-0"
OF SIDE PROPERTY LINES
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
7.5
12
7.5
12
7.5
12
7.5
12
12
12
12
12
4
12
4
12
4
12
NORTH ELEVATION
E N
/A
F 2
24.0
E 2
24.3
F 2
24.0
E 2
23.9
F 2
23.5
E 2
23.9
F 2
23.5
NORTH ELEVATION
WEST ELEVATION
A3.0
10.2
12
4
12
E 2
23.9
F 2
23.5
E 2
23.9
F 2
23.5
E 2
23.1
F 2
23.0
WEST ELEVATION
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
EDCBA
A
-
1 2 3 4 5 6 7 8 9
A
-
3070
3070
3070 30503050
2036 2036
2036 2036
26402640 2036 26402640
2630
2640
26402640
2640
10
"
1'-
2"
3 1
/2"
1'-2"9
1/4
"
11 1
/4"
1'-
3"
6'-
6 5
/8"
3 1
/2"
2'-
6"
1'-8"
3 1/2"
11 1
/4"
9 1
/4"
3'-
1"
3"
9 1/4"
9 1
/4"
5 1
/2"
5 1/2"
3 1
/2"
11
1/4
" 8"
3'-
0"
5 1/2"
7 1/4"
10"2'-2"
1'-
2"
9 1
/4"
8"
8"
9 1/4"
3"
8"R
3'-
0"
4"
2'-0"1'-0" 1'-0"
1'-0"
E N
/AF 2
25.5
1
E N
/AF 2
44.1
4
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
26402640
7.5
12
7.5
12
4
12
4
124
12
4
12
7.5
12
E 2
23.1
F 2
23.0
E 2
24.4
F 2
24.0
SOUTH ELEVATION
EAST ELEVATION
A3.1
SOUTH ELEVATION
EAST ELEVATION
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
4
12
+/- 5.8
12
+/- 5.8
12
E 2
24.4
F 2
24.0
E N
/AF 2
24.0
E 2
24.3
F 2
24.0
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
E D C B A
A
-
123456789
A
-
30503050
30503050
3/3070
3/3070
2036
30403040304030402/2668
2/26682640 26402'-0" 4" MAX
3'-
6"
3'-
0"
1'-
0"
9 1/4"
9 1
/4"
7 1
/4"
11 1
/4"
1'-0"
1'-0"
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
7 7
EXPOSING
BUILDING FACE
CALCULATIONS
A3.2
7 7
7
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
SOUTH ELEVATION
57.13% UPROTECTED OPENINGS ALLOWED7.14% UPROTECTED OPENINGS ALLOWED
WEST ELEVATION
EAST ELEVATION
7.14% UPROTECTED OPENINGS ALLOWED
MAX SIZE OF INDIVIDUAL OPENINGS IS 8.4 SQ FT
MAX SIZE OF INDIVIDUAL OPENINGS IS 8.4 SQ FT
7
7 7
7
63 6315151515
3312 12 12 12 12 1233
SOUTH ELEVATION
10 10 7 7.5 10 10
21 7 7 21 15 15
10
21
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
A4.0
TYPICALCROSS
SECTION
RWLRWLE 2
23.9
F 223
.5
E 224
.3
F 224
.0
TW 225.5
BW
223.9
TW 2
26.4
BW
224
.5
CROSS SECTION B
RID
GE
F 251.55
SCALE 1/4"=1'-0"
TYP BELOW GRADE CELLAR WALL ASSEMBLY
TYPICAL HEATED SLAB ASSEMBLY
TYPICAL INTERIOR FLOOR ASSEMBLY
TYPICAL EXTERIOR WALL ASSEMBLY
TYPICAL ATTIC ROOF ASSEMBLY
TYPICAL INTERIOR FLOOR ASSEMBLY
TYPICAL EXTERIOR WALL ASSEMBLY
225.75' MAIN
216.75' BASE
235.75' SECOND
250.75' RIDGE
8'-
0"
9'-
0"
8'-
0"
VENT VENT
FLOOR ASSEMBLIES
F1 BASEMENT FLOOR ASSEMBLY
FINISH FLOOR ONMIN. 4" REINFORCED CONCRETE SLABC/W INFLOOR RADIANT HEAT ONPOLY MOISTURE BARRIER ONMIN. R12 EPS RIGID INSULATION ONMIN. 6"CLEAR CRUSH ONFIRM NATIVE OR COMPACTED FILL
F2 MAIN + SECOND FLOOR ASSEMBLY
FINISH FLOOR ONMIN. 1 ½" LIGHTWEIGHT CONCRETE TOPPINGC/W INFLOOR RADIANT HEAT ONMIN 5/8" T&G PLYWOOD SUBFLOORGLUED AND SCREWED TO2x FLOOR JOISTS SEE STRUCT.C/W R12 FIBREGLASS BATTS½" G.W.B.
F3 FLOOR OVER EXTERIOR ASSEMBLY
FINISH FLOOR ONMIN. 1 ½" LIGHTWEIGHT CONCRETE TOPPINGC/W INFLOOR RADIANT HEAT ONMIN 5/8" T&G PLYWOOD SUBFLOORGLUED AND SCREWED TO2x FLOOR JOISTS SEE STRUCT.C/W R12 FIBREGLASS BATTS1x4 V-JOINT PRIMED SPF SOFFITT
F4 EXTERIOR DECKS (UNHEATED BELOW)
EXTERIOR GRADE TILE ONTHINSET + 1 ½" DRYPACK ONDRAINAGE MAT ON2 PLY SBS ROOFING MEMBRANE ONMIN. 5/8" T&G PLYWOOD SUBFLOOR ON2x CROSS PURLINS ON2x FLOOR JOISTS - SEE STRUCT.1x4 V-JOINT PRIMED SPF SOFFITT
ROOF ASSEMBLIES
R1 ATTIC ROOF ASSEMBLY
MIN. 30 YEAR LAMINATED ASPHALT SHINGLESINSTALLED AS PER RCABC STANDARDS ON½" PLYWOOD SHEATHING ONMANUFACTURED ROOF TRUSSES @ 24" OCC/W R50 FIBREGLASS BATTS INSULATION6 MIL POLY U/V AIR/VAPOUR BARRIER5/8" G.W.B.
R2 ROOF OVER EXTERIORMIN. 30 YEAR LAMINATED ASPHALT SHINGLESINSTALLED AS PER RCABC STANDARDS ON½" PLYWOOD SHEATHING ONMANUFACTURED ROOF TRUSSES @ 24" OC1x4 V-JOINT PRIMED SPF SOFFITT
WALL ASSEMBLIES
W1 TYPICAL EXTERIOR WALL ASSEMBLY
CEMENTITIOUS SIDING (HARDIE TYPE) ON1x PT VERTICAL BATTENS @ 12" OC ONHOUSE WRAP SHEATHING PAPER ON½" FIR PLYWOOD SHEATHING ON2x6 @ 16" OC SEE STRUCT.C/W R22 HIGH DENSITY F. BATTS INSULATION6 MIL POLY A/V AIR/VAPOUR BARRIER½" G.W.B.
W2 BASEMENT FURRING WALL ASSEMBLY (UPPER)
CEMENTITIOUS SIDING (HARDIE TYPE) ON1x PT VERTICAL BATTENS @ 12" OC ONHOUSE WRAP SHEATHING PAPER ON½" FIR PLYWOOD SHEATHING ON2x6 @ 16" OC SEE STRUCT.2 ½" AIR SPACE2x6 @ 24" OC FURRING STUD WALLC/W R22 HIGH DENSITY F. BATTS INSULATION6 MIL POLY A/V AIR/VAPOUR BARRIER½" G.W.B.
W3 NOTUSED
W4 BASEMENT FURRING WALL ASSEMBLY (LOWER)
BACKFILL ONDIMPLE DRAINAGE MAT AGAINST2 LAYERS DAMP PROOFING ON8" REINFORCED CONCRETE WALL ½" AIR SPACE2x6 @ 24" OC FURRING STUD WALLC/W R20 F. BATTS INSULATION6 MIL POLY A/V AIR/VAPOUR BARRIER½" G.W.B.
W5 INTERIOR PARTITION WALL½" G.W.B ON2x4 STUD WALL SEE STRUCT. FOR SHEAR WALLS½" G.W.B. USE TILE BACKER IN WET AREAS
W6 SUITE DEMISING WALL(BCBC A-9.10.3.1.A - W11B)1 HOUR FRR + STC 54½" TYPE X G.W.B. ON2x4 STAGGER STUD WALL ON2x6 PLATESC/W MINERAL WOOL ACOUSTIC INSULATIONRESILIENT METAL CHANNELS2 LAYERS ½" TYPE X G.W.B.
CONFORMANCE TO 9.32.3.3
FOUR BEDROOMS - 193 SQ M THEREFORE WE REQUIRE A MIN. OF 35 L/s (119 CFM) OF EXHAUST FAN VENTILATION
7.5
12
7.5
12
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
PrivateDEVELOPMENT
321 West 14th StreetNorth Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
WINDOW SEQUENCING DIAGRAMS ASSUMPTIONS:
1. 2X INSULATED WALL - NO OUTBOUND INSULATION2. BUILDING PAPER IS SHOWN / HOUSEWRAP CAN BE USED3. VERTICAL BATTENS FOR RAINSCREEN ARE EMPLOYED/ DRAIN MAT CAN BE USED3. FLANGED WINDOW INSTALLATION4. WOOD INTERIOR JAMB LINERS SHOWN
ARCHITECT SHALL BE CALLED TO SITE TO REVIEW (AT A MINIMUM):
A. TYPICAL ROUGH OPENING PREPB. TYPICAL WINDOW INSTALLATIONC. INSTALLATION OF VAPOUR BARRIER
STEP 1: INSTALL STARTER STRIP OF BUILDING PAPER OR WRAP / INSTALL MIN 1/2" SILL BACKER
STEP 2: INSTALL SELF ADHERED WATERPROOF MEMBRANE - ENSURE RETURN UP SILL BACKER, UP JAMBS 4" AND BEYOND JAMB 4" ON FACE. ALL SURFACES TO BE PRIMED AS REQ'D
STEP 4: INSTALL P.T. STRIPS TO RECEIVE WINDOW FLANGE. AT SILL AVOID CORNERS. INSTALL PLASTIC SHIMS AS REQ'D - BUILDER CAN PROPOSE ALT. MEANS OF PROVIDING DRAINAGE // DO NOT FLEX WINDOW FLANGE
STEP 5: INSTALL WINDOW - NAILING AS PER MANUFACTURERS SPECIFICATION. INSTALL HEAD FLASHING OVER W/ 3" LEG AND END DAMS - DO NOT BACK CAULK FLANGE.
STEP 3: INSTALL JAMB PAPER FOLDING INTO JAMB IN LINE WITH SILL BACKER. LEAVE SHY OF S.A.M. MEMBRANE ON HORIZONTAL - TOP IS SLIT TO ALLOW FOR FOLDING. INSTALL HEAD PAPER AS JAMBS.
STEP 7: INSTALL P.T. VERTICAL BATTENS. BUILDER SHOULD ANTICIPATE LOCATIONS OF TRIMS WHERE NECESSARY AS WELL AS PROVIDING ADEQUATE STRUCTURE FOR INSECT SCREEN.
STEP 8: INSTALL ALL TRIMS. RECOMMEND TO SITE BUILD SLOPED SILL AND APRON PRIOR TO INSTALLATION. INSTALL HEAD FLASHING C/W END DAMS MOUNTED ON BATTENS OVER THE HEAD TRIM.
STEP 6: INSTALL BALANCE OF FIELD PAPER - SHINGLE IF USING BUILDING PAPER OR TAPE WHERE NECESSARY IF USING HOUSEWRAP
STEP 10: IN THE INTERIOR STUD CAVITIES INSTALL BATT INSULATION AND RIGID INSULATION AT HEADERS. BACK OF WINDOW SHOULD BE ROD AND CAULKED TO AIR BARRIER (BUILDING PAPER) AT THIS TIME.
STEP 11: INSTALL A BEAD OF ACOUSTIC SEALANT AROUND THE PERIMETER INSIDE FACE OF FRAMING AROUND WINDOW - STAPLE POLY THROUGH SEALANT TO ALLOW FOR PROPER SEAL. ALL POLY TO POLY SEALING SHOULD BE WITH TECH TAPE. THERE SHOULD BE NO EXPOSED WOOD.
STEP 9: INSTALL EXTERIOR CLADDING
STEP 13: INSTALL INTERIOR STOOL. INSTALL JAMB LINERS IF WOOD - IF DRYWALL RETURNS INCOPORATE INTO PREVIOUS STEP.
STEP 14: INSTALL FINISH TRIMSSTEP 12: INSTALL DRYWALL FINISH. DRYWALL TRADE TO PRE-CUT OPENINGS - DO NOT USE A CUT OUT TOOL. IF THE POLY VAPOUR BARRIER IS DAMAGED IT WILL HAVE TO BE MADE GOOD.
PLY BACKER - COORDINATE DIM. W/ WINDOW FRAME DEPTH
STAPLE AT TOP
4"
4"
12
3
SLIT - TURN FLAP DOWN
END DAMS
INSERT CLOSED CELL POLY BACKER ROD AROUND ENTIRE PERIMETER - THEN CONTINUOUS SEALANT BEAD
LINE OF MASTIC
ALL CUT CORNERS OF POLY TO BE SEALED WITH TECH TAPE
ENSURE AIR BARRIER OR SHEATHING MEMBRANE IS CONTINUOUS
BACKING FOR SHEATHING AS REQUIRED
CONTINUOUS AIR/VAPOUR BARRIER
CLADDING ON DRAINAGE MATT - TYPICAL
PLAN DETAIL - TYP. OUTSIDE CORNER
SCALE 1 1/2"=1'-0"
7
PLAN DETAIL - TYP. INSIDE CORNER
SCALE 1 1/2"=1'-0"
ENSURE AIR BARRIER OR SHEATHING MEMBRANE IS CONTINUOUS
BACKING FOR SHEATHING AS REQUIRED
CLADDING ON DRAINAGE MATT - OR RAINSCREEN
6
SECTION DETAIL - SMALL PENETRATION
SCALE 1 1/2"=1'-0"
AIR BARRIER TO U/S OF PENETRATION
S.A.M. GASKET ADHERE TO WOOD SHEATHING ABOVE AND TO SHEATHING PAPER/ AIR BARRIER BELOW. ENSURE GOOD SEAL TO PIPE
AIR BARRIER ABOVE TO BE CUT TIGHT AROUND PIPE AND TAPED TO AIR BARRIER BELOW (IF USING BUILDING WRAP) - IF USING BUILDING PAPER PROVIDE POSITIVE LAPPING
CAULKING AROUND PENETRATION TO CLADDING
TYPICAL PENETRATION
5
CONTINUOUS AIR/VAPOUR BARRIER
A4.1
SEQUENCING DIAGRAMMISCELLANEOUS DETAILS
LAP SHEATHING PAPER OVER PREFINISHED ALUM. FLASHING & SELF-ADHERED MEMB.
2x BLOCKING AS REQ'D FOR ATTACHMENT
TYP. INSECT SCREEN
LOWER STRIP OF BUILDING PAPER TO TERMINATE AT TOP OF PENETRATION, MIN.
SELF-ADHERED MEMB.CONT. SEALED TO
PENETRATION - EXTENDMIN. 3" BEYOND
PENTRATION AT ALL SIDES
SEAL POLY TO PLYWD.PLATE C/W HOLE FOR
PENTRATION-PROVIDE CONT. ACOUSTIC
CAULK AROUNDPENTRATION FOR SEAL
CLADDING ON RAINSCREEN
TYP. PENETRATION DETAIL
SCALE 3"=1'-0"
4
SEE STRUCTURAL FOR LINTEL REQUIREMENTS
CONTINUOUS 6 MIL POLY VAPOUR BARRIER TYP.
TYPICAL JAMB LINER AND INTERIOR CASING
VINYL WINDOW - INSTALLED AS PER MANUF. SPECS
PREFINSHED METALFLASHING SET ON
RAINSCREEN C/W ENDDAMS TO EXTEND 1"
PAST END OF WINDOWFRAME
HEAD TRIM SET ONRAINSCREEN
TYP. BUG SCREEN @BOTTOM OF RAIN
SCREEN
PREFINISHED METALFLASHING INSTALLED
BETWEEN TWO LAYERSOF BUILDING PAPER C/WEND DAMS TO EXTEND 1"
PAST END OF WINDOWFRAME 5
1/2
"
INTERIOR
TYP. WINDOW HEAD DETAIL
SCALE 3"=1'-0"
1
VINYL WINDOW - INSTALLED ASPER MANUF. SPECS
PREFINISHED METAL REVERSEFLASHING
SITE BUILT WOOD SILL ANDAPRON - SILL SLOPE 7 DEG C/WDRIP - CANT TOP OF APRON AS
SHOWN, SET RAINSCREEN
3 1/2"
3 1
/2"
NOMINAL ANGLE BACK STOP - SET AT BACK OF WINDOW FRAME - TYP. PEEL AND STICK IS INSTALLED UP AND OVER ANGLE & LAPPED BETWEEN 2 LAYERS OF BUILDING PAPER// BUILDER CAN USE 1/2" PLYWOOD BACK STOP AS ALTERNATE
INTERIOR STOOL / APRON
BRING 1 LAYER OF BUILDING PAPER UP AND OVER SILL
CONTINUOUS 6 MIL POLY VAPOUR BARRIER TYP.
INTERIOR
TYP. WINDOW SILL DETAIL
SCALE 3"=1'-0"
2
TYP. WINDOW JAMB DETAIL
SCALE 3"=1'-0"
3
INTERIOR STOOL
TYPICAL JAMB LINER ANDINTERIOR CASING
VINYL WINDOW - INSTALLED AS
PER MANUF. SPECS
ROD AND CAULK
LEG TRIM ON RAINSCREEN
SEE INTERIOR SPECS
CLAD WOOD EXTERIOR SILL
CLADDING ON RAINSCREEN
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
PrivateDEVELOPMENT
321 West 14th StreetNorth Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
SCALE 1 1/2"=1'-0"
1'-
0"
SET PLATE TO ALLOW FOR
1" OFFSET FROM FACE OFCLADDING TO FOUNDATION TYP.8
" M
IN.
1x2 POUR STRIP VOID - ENSURE SHEATHING DOES NOT SIT ON CONCRETE
INSECT SCREEN AT BOTTOM OF RAINSCREEN
SHEATHING MEMBRANE (HOUSE WRAP OR 2 LAYERS 30 MIN BLDG PAPER
LINE OF 6 MIL POLY U/V AIR/VAPOUR BARRIER
TYPICAL UPPER BASEMENT WALL ASSEMBLY
TYPICAL BELOW GRADE BASEMENT WALL ASSEMBLY
DRAINAGE MAT ON 2 LAYERS OF DAMPPROOFING OR WATER PROOFING
2x8 PLATE ON SILL GASKET
SECTION DETAIL - TOP OF FOUNDATION1
COMPACTED GRAVEL FILL
POLY MOISTURE BARRIER FROM SLAB IS PULL OUT ALONG FLOOR PRIOR TO INSTALL OF INTERIOR FURRING WALL
TYPE III - EPS - RETURN UP WALL FOR CONTINUOUS LINE OF INSULATION
LAP AND SEAL INTERIOR WALL POLY TO SLAB POLY AS SHOWN
DIMPLE MAT ONWATERPROOFING MEMBRANE
4" PERF. PVC PERIMTER DRAIN - INSTALL HOLES DOWN MIN. 6" GRAVEL ALL SIDES - TOP WITH LANDSCAPE FABRIC PRIOR TO BACK FILL
SECTION DETAIL - BOTTOM OF FOUNDATION
SCALE 1 1/2"=1'-0"
2
PLANE OF AIR TIGHTNESS DETAILS
1. SHOWING CONTINUOUS POLY ONLY2. POLY TO POLY - SEAL WITH TECH TAPE3. POLY TO WOOD - SEAL WITH ACOUSTIC SEALANT
DETAIL 1 - AT SLAB
CONC. SLAB
CO
NC
. W
AL
L
UNDERSLAB POLY TO BE SEALED TO WALL POLY
XPS
XP
S
INSTALL POLY STRIP BETWEEN TOP PLATES - SEAL TO WALL POLY - SEAL CEILING POLY AFTER INSTALL TO ENTIRE ASSEMBLY
DETAIL 2 - AT FLOOR /RIM
SEAL POLY STRIP TO PLYWOOD FLOOR PRIOR TO POUR
SEAL WALL POLY TO STARTER STRIP
POLY TO BE CUT AT JOISTS AND SEALED TO U/S OF PLYWOOD AND ADJACENT JOISTS
DETAIL 3 - AT PERPENDICULAR INT/EXT WALL JUNCTION
INSTALL POLY STRIP PRIOR TO INT. WALL FRAME - SEAL EXT. POLY TO STRIP
DETAIL 4 - AT HIGHEST CEILING
SCALE 1 1/2"=1'-0"
SECTION DETAIL - FLAT SOFFITT (UPPER)
3
1'-0"
EAVES PROTECTION
1 1/
2"
MA
INTA
IN C
LR
/ O
R
INS
TA
LL E
AV
ES
BA
FFLE
VENT
1x4 V-JOINT SPF - PAINT FINISH
ENSURE TOP OF RAINSCREEN IS BLOCKED TO SOFFITT
FLASHING INTO EAVES TROUGH
ENSURE PLY CONTINUOUS AT TOP TO PLATE TO CEILING
CONTINUOUS 1.5" STRIP VENT
ALUMINUM EAVES TROUGH SET ON 2x GUTTER FASCIA - PAINT FINISH
SCALE 1 1/2"=1'-0"
SECTION DETAIL - RAKED SOFFIT (LOWER)
4
1'-0"
EAVES PROTECTION
1 1/
2"
MA
INTA
IN C
LR
/ O
R
INS
TA
LL E
AV
ES
BA
FFLE
ENSURE TOP OF RAINSCREEN IS BLOCKED TO SOFFITT
FLASHING INTO EAVES TROUGH
ENSURE PLY CONTINUOUS AT TOP TO PLATE TO CEILING
ALUMINUM EAVES TROUGH SET ON 2x GUTTER FASCIA - PAINT FINISH
1.5" DRILL FOR VENTILATION - INSTALL LOUVRED VENT
VENT
PAINTED 2x6 TRUSS TAIL
SCALE 1 1/2"=1'-0"
LOWER KNEE BRACE5
1"
TYPICAL ROOF SHEATHING - INSTALL THICKNESS TO MATCH EXPOSED EAVE SOFFIT
SCALE 1 1/2"=1'-0"
UPPER KNEE BRACE6
SCALE 1 1/2"=1'-0"
THROUGH WALL FLASHING8
A4.2
AIR TIGHTNESS DIAGRAMMISCELLANEOUS DETAILS
SCALE 1 1/2"=1'-0"
ALT. FOUND. DETAIL7
R12 BATT INSULATION
3"
MIN
.1
1/4
"
11
1/4
"
THROUGH WALL FLASHING SET ON SHEATHING PAPER - LAP TOP LAYER OVER FLASHING LEG
IF USING PT BATENS FOR RAINSCREEN - INSTALL BUG SCREEN ON PAPER - PULL TAUT AND STAPLE TO BATTENS
TYPICAL S3S SPRUCE BAND BOARD - PAINT FINISH - RABBETT BOTTOM OF TRIM AS SHOWN - LET SIDING UNDER
POLY VAPOUR BARRIER TO BE LED UP BETWEEN JOISTS TYPICALLY - SEAM ALL POLY TO WOOD WITH ACOUSTIC SEALANT
R12 BATT INSULATION
SEAL POLY STRIP TO PLYWOOD PRIOR TO POURING CONCRETE TOPPING - TAPE POLY STRIP TO WALL POLY WHEN INSULATING
9 1
/4"
9 1
/4"
1'-
2"
1 1
/2"
3"
SCALE 1 1/2"=1'-0"
PARTY WALL @ FOUNDATION9
SCALE 1 1/2"=1'-0"
PARTY WALL @ INTERIOR FLOORS10
SCALE 1 1/2"=1'-0"
PARTY WALL @ CEILING / ROOF11
CONC
CONC
CONC
EPS EPS
POLY MOISTURE BARRIER TO CONTINUE OVER INTERIOR FOUNDATION WALL
TYPICAL 45 MIN FRR DEMISING WALL
TYPICAL 45 MIN FRR DEMISING WALL
DRYWALL BOTH SIDES TO EXTEND TO THE UNDERSIDE OF PLYWOOD SUBLFOOR - G.W.B. TO BE SNUG FIT TO TJIS AND FIRE CAULKED IF NECESSARY
LIGHTWEIGHT CONC. TOPPING
G.W.B. TO CONTINUE UP TO THE UNDERSIDE OF ROOF SHEATHING - TIGHT FIT INCL. FIRE CAULK IF NECESSARY
TYPICAL 45 MIN FRR DEMISING WALL
R50 F. BATTSPOLY U/V AIR/VAPOUR BARRIER TO BE MECHANICALLY FASTENED THROUGH ACOUSTIC SEALANT TO BLOCKING
RESILIENT CHANNELS
ACOUSTIC MINERAL WOOL
2X4 STAGGER STUDS
2X6 PLATES
WOOD MANUFACTURERED ROOF TRUSS
WOOD MANUFACTURERED ROOF TRUSS
R12
6"
3'-0"
3'-
0"
3"
3"
45°
45°
9 1/
4"
6 1/
4"
RADIU
S = +
/- 3'
-0"
6"
SOLID BLOCK - LAG AND PLUG KNEE BRACE THROUGH PEEL AND STICK MEMBRANE INSTALLED ON SHEATHING - SNUG SHEATHING PAPER UP AGAINST VERTICAL LEG
ATTIC
TYPICAL BLOCKING
COMMON TRUSS
2x4 LOOK OUTS
FLAT - CROSS STRAP LOOKOUTS - INSTALL V-JOINT SOFFIT - NO VENTING ON RAKE
GABLE - DROP TRUSS
3'-
0"
7 1/
4"
5"
7"
6"
1'-4 1/4"
1'-
4 1
/4"
3'-0"
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
PrivateDEVELOPMENT
321 West 14th StreetNorth Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM
BIKE PARKING
1 2 3
GARAGE PLAN
SCALE 1/4"=1'-0"
EXG. 2
22.6
'
FIN
. 222
.28'
EXG. 222.28'
FIN
. 222.28'
EXG. 220.6'
FIN
. 220.38'
EXG. 2
20.3
8'
FIN
. 220
.38'
8070 O/H DOOR 8070 O/H DOOR 8070 O/H DOOR
2868 2868 2868
SECURE MTL GATE
A
-
GARAGE ROOF PLAN
SCALE 1/4"=1'-0"
4:1
24
:12
4:12 4:12
4:1
2
4:12 4:12
A
-
TOP OF CONCRETE 221.00'
TOP OF CONCRETE 221.00'
TOP OF CONCRETE 222.25'
TOP OF CONCRETE 222.25'
TOP OF CONCRETE 223.00'
TOP OF CONCRETE 223.00'
HOLD DOWN FOR DOOR +3"
OVER ADJ. GRADE TYP.
HOLD DOWN FOR SLAB OVER TYP.
1%
SO
PE
ON
LY
1%
SO
PE
ON
LY
1%
SO
PE
ON
LY
20
'-0
"6
'-4
1/2
"
30'-0"
14'-10 1/2" 10'-9" 4'-4 1/2"
1'-11 1/2" 9'-11 1/4" 16'-1 3/4" 1'-11 1/2"
5'-2" 9'-10" 9'-10" 5'-2"
SLAB ELEV.
222.50'
SLAB ELEV.
220.5'
SLAB ELEV.
221.5'
10'-1 1/2" 9'-9" 10'-1 1/2"
1'-7 1/2"
1'-
7 1
/2"
1'-
7 1
/2"
1'-7 1/2"
1'-
7 1
/2"
1'-7 1/2"
PROVIDE RIDGE VENT
SECTION A
SCALE 1/8"=1'-0"
SLAB 220.5'
SLAB 222.5'
PLATES 230.5'
4
12
4
12
4
12
RIDGE 234.05'
N
NORTH ELEVATION
SOUTH ELEVATION
4
12
4
12
1 2
3
4
12
4
12
SECURE BIKE
PARKING
SLAB 220.5'
SLAB 222.5'
PLATES 230.5'
RIDGE 234.05'
SLAB 220.5'
SLAB 222.5'
PLATES 230.5'
RIDGE 234.05'
EXG. 220.6'
FIN
. 220.38'
EXG. 2
22.6
'
FIN
. 222
.28'
EXG. 222.28'
FIN
. 222.28'
EXG. 220.38'
FIN
. 220.38'
WEST ELEVATION
EAST ELEVATION
4
12
4
12
4
12
4
12
4
12
4
12
SLAB 220.5'
SLAB 222.5'
PLATES 230.5'
RIDGE 234.05'
SLAB 220.5'
SLAB 222.5'
PLATES 230.5'
RIDGE 234.05'
EXG. 222.6'
FIN
. 222.28'
EXG. 220.38'
FIN
. 220.38'
EXG. 2
20.6
'
FIN
. 220
.38'
EXG. 222.28'
FIN
. 222.28'
A5.0
GARAGE PLAN
GARAGE ROOF PLAN
GARAGE SECTION
GARAGE ELEVATIONS
EXTERIOR WALL ASSEMBLY
CLADDING TO MATCH TRIPLEX ON
SHEATHING PAPER - HOUSE WRAP ON
1/2" FIR PLYWOOD SHEATHING ON
2x4 STUD WALL @ 16" OC - SEE STRUCT
TYPICAL SLAB ASSEMBLY
MIN. 4" REINFORCED CONC. SLAB - SEE STRUCT ON
POLY MOISTURE BARRIER ON
MIN 6" CLEAR CRUSH FILL ON
FIRM NATIVE OR COMPACTED FILL
TYPICAL ROOF ASSEMBLY
MIN. 30 YEAR LAMINATED ASPHALT SHINGLES
TO MATCH TRIPLEX - INSTALLED AS PER RCABC
GUARRANTY STANDARDS ON
1/2" FIR PLWOOD SHEATHING ON
MANUFACTURED ROOF TRUSSES @ 24" OC
SEE STRUCT.
SLOPE GRADE AWAY
FROM FOUND. TYP.
MIN
. 1
8" B
EL
OW
GR
AD
E T
YP
.
1 H
R F
RR
- W
AL
L T
O
EX
TE
ND
TO
U/S
RO
OF
SH
EA
TH
ING
1 H
R F
RR
- W
AL
L T
O
EX
TE
ND
TO
U/S
RO
OF
SH
EA
TH
ING
2868
2868
2868
265 SQ FT EXPOSING BUILDING FACE
53.3 SQ FT UNPROTECTED OPENINGS
4.0 FT LIMITING DISTANCE
Revisions
No. Date Details By
Project
Drawing Title
BUILDER'S RESPONSIBILITY TO LAYOUT WORK
It is the Builder's responsibility to lay out & carry out thework as detailed in the contract documents. It is thereforenecessary for the builder to pay very close attention to actual site dimensions, geometries and conditions whichmay vary from those assumed on the drawings.
Any discrepencies which the Builder discovers within thecontract documents themselves or between the contractdocuments & site conditions, are to be discussed with the Architect immediately before proceeding with any work.
Written dimensions shall have precedence over scaleddimensions.
Copyright Reserved.
This plan and design are, and at all times remain, the ex-clusive property of HEARTH architectural Inc. and maynot be used or reproduced without written consent.
Drawing No.
Date
Scale
Approved By
Project No.
Drawn By
Private
DEVELOPMENT
321 West 14th Street
North Vancouver BC
FEB 2016 1570
AS SHOWN
HAI
VJM
1 FEB 29 2016 ISSUED FOR DEV APP VJM
2 AUG 22 2016 ISSUED in RESPONSE VJM
3 JAN 26 2017 ISSUED FOR COORD VJM
4 FEB 7 2017 ISSUED FOR BP VJM