Pilot 1600 Manual-En
-
Upload
bogdan-bucataru -
Category
Documents
-
view
747 -
download
9
Transcript of Pilot 1600 Manual-En
![Page 1: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/1.jpg)
rel. 1.03
Pilot111600
user manual20 channels dmx controller
1
mode keyboard
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
record program scene manual enter
menu copy
10
PILOT 1600REL. 1.03
9
8
7
6
5
4
3
2
1
0
record / program / scene / scanner
speed rate
music sync edit keyboard
data entry
Pilot16 channels dmx controller
1600
upper row
lower row
mirror positioning speed regulation
escscroll
![Page 2: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/2.jpg)
page
1
EN appendiceI D F E
General IndicationsRead the instructions in this manual carefully, as they give important indications regarding safety dur-
ing the unit’s installation, use and maintenance.
Make certain to keep this manual with the unit for future consultation.
If the unit is sold to or used by another operator, make sure that the manual is always with the unit
to enable the new owner or user to read about its operation and relative instructions.
• Not for residential use.
• After having removed the packaging, check that the unit isn’t damaged in any way: if you have any
doubts, don’t use the unit and contact an authorized SGM service centre.
• Packaging material (plastic bags, polystyrene, nails, etc.) must be kept out of the reach of children,
as it could be dangerous.
• This unit must only be operated by adults. Don’t allow children to tamper or play with it.
• Any electrical work required for installing the unit must be carried out by qualified electricians or
other people with sufficient experience.
Avoid using the unit:
• in places subject to excessive damp (ideal conditions are between 35% and 80%)
• in places subject to vibration or the risk of bumps
• in places in which the temperature is above 45° or below 2°C
• Do not dismantle or modify the unit
• Make certain that no inflammable liquids, water, metal objects or other foreign bodies enter the unit.
• Should any liquid enter the unit, turn off the power supply immediately.
• Should there be any serious operating problem with the unit, switch it off and take it to the nearest
authorized SGM service centre for a check-up or contact the manufacturer directly.
• Never open the unit: there are no user-replaceable parts inside.
• Never try to repair the unit yourself. Repairs carried out by inexperienced people can cause further
damage or serious malfunction: contact the nearest authorized SGM service centre.
Always insist that any spares fitted are original.
Safeguard the environment: don’t throw batteries, accumulators or
packages into your trash can: return them to your retailer or take them to the nearest
special waste collection point.
![Page 3: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/3.jpg)
page
2
Index
1 General indications
2 Index
3 Chapter 1 - Pilot 1600’s structure
3 Chapter 1.1 - Main features
4 Chapter 1.2 - Display and keyboard
5 Chapter 1.3 - Pilot 1600 controls
6 Chapter 2 - Starting to use the Pilot 1600
7 Chapter 2.1 - Soft Patch
7 Chapter 3 - Manual operation
8 Chapter 4 - Using the Program mode
9 Chapter 5 - Using the Record mode
10 Chapter 6 - Copy function
12 Chapter 7 - Advanced functions
12 Chapter 7.1 - Set-up
12 Chapter 7.2 - Edit UNLBL
13 Chapter 7.3 - Edit EFLBL
13 Chapter 7.4 - CFG UNIT
15 Chapter 7.5 - CFG RESVAL
15 Chapter 7.6 - CFG LMPVAL
16 Chapter 7.7 - Store & Load File
17 Chapter 7.8 - Back-up and restore
18 Chapter 7.9 - Menu & Copy enable/disable
19 Chapter 7.10 - Soft Patch reset
20 Chapter 8 - Remote fixture controls
20 Chapter 8.1 - Remote reset
20 Chapter 8.2 - Remote lamp on/off
Made in Italy by SGM ElectronicPrinted in September, 1998 • Rel. 1.03
![Page 4: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/4.jpg)
page
3
EN appendiceI D F E
1. Pilot 1600’s structure1.1 Main features
The Pilot 1600 is a controller for scanners or intelligent lighting fixtures which use a maximum of 20control channels and DMX 512 protocol.The unit’s main feature is its flexibility: data regarding the fixtures which it controls is in fact stored in abuilt-in library, to which new fixtures can be added up to a maximum of 64. For each of these, logicchannels different from the physical ones can be allocated, thus simplifying connection with the fix-tures controlled.Pilot 1600 controls 16 programs, each of which is made up of a maximum of 16 scenes and 16records made up of program sequences of up to a maximum of 100 steps (each step contains a pro-gram and Speed and Rate settings).Speed is the speed with which the scanners’ mirrors moves (Pan and Tilt), whereas Rate is the rate atwhich the unit passes from scene to scene in a program: both can be changed at any time while theprogram is running.It’s also possible to control some fixtures manually - even while a program is running - and add fix-tures to or remove them from the group under manual control.Pilot 1600 also allows operators to store programs in protected areas and to transfer stored data toother units.
1.2 Display and keyboardAll Pilot 1600 control parameters are shown on the alphanumerical display, which shows the following
message when the unit is switched on . Parameters which can be modified by the
operator can be changed using the cursor keys or the Data Entry slider.The various operating modes available are selected using the “Keyboard mode” keyboard.According to the operating mode, keys 1-16 are used to select the unit to control, the program orrecord to be run or the fixture to be controlled manually.
PILOT-1600VERS. 1.03
1
mode
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
record program scene manual enter
menu copy
10
PILOT 1600REL. 1.03
9
8
7
6
5
4
3
2
1
0
selection
speed rate
music sync edit keyboard
data entry
Pilot16 channels dmx controller
16001600
upper row
lower row
mirror positioning speed regulation
escscroll
![Page 5: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/5.jpg)
page
4
To facilitate the procedure of setting mirrors whenscanners are being used, during programming, theRATE slider operates as a controller of the mirror’smovement, which remains linked with the joystick.Joystick movement is automatically converted toparameters for Pan and Tilt control.
1.3 Pilot 1600 controls
All Pilot’s control functions are accessible via a tree structure shown in the diagram below.The cursor keys or the Data Entry are used to move, access to the various commands is given with the
key and the key is used to exit the command. When operators leave the command,
the Pilot displays the following message: . Press to confirm, or to return to the previous level without confirming any changes. When the Pilot 1600 is switched on,
the following message is displayed: . This message appears for 3 seconds, after
which the following is appears : now press any of the keys numbered from 1 to 16
to select the program to be used. ÷ .
PROGR=_SCENE=_
PILOT-1600VERS. 1.03
SAVE? Y/NENT/ESC
Menù Principale
Edit Program Edit Record Soft Patch Setup
EDIT SCENE
UNIT MASK
Edit UNLBL
Edit EFLBL
CFG UNIT
CFG RESVAL
CFG LMPVAL
LOAD/STORE
BACKUP/RESTORE
MENU/COPY EN
PATCH RESET
Main MenuPilot 1600 command layout
![Page 6: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/6.jpg)
page
5
EN appendiceI D F E
2. Starting to use the Pilot 16002.1 Soft Patch
The Pilot 1600 is a universal controller, so for correct operation the first fundamental operation to becarried by the operator is to define what fixtures are connected to the Pilot.This is done using the Soft Patch function.
Access this function by pressing then on the EDIT keypad, and with the keyor the DATA ENTRY slider scroll the commands until the following appears on the display:
. Press for access to allocation. A LED will light up above the key, showing that you are working with fixture No.1.
Use the and keys in the top row or Data Entry to select the required fixture: e.g.
. The start address for this fixture must now be set. Press . The value on
the line of the start address changes to 001: . You can now key in another value(which must however correspond to that set on the fixture), or accept the value proposed (001, as this
is fixture No.1). Press to set the value chosen for this fixture.
When the key in the bottom row of the DATA SELECT group is pressed, the display indicates
the conversion of the start address to a dip-switch position: . This is extremely
useful when working with fixtures which use this system of setting. Use the arrow to return tonumerical mode.Pilot 1600 units are factory-programmed with the start addresses of the fixtures stored every 25.When a new unit is selected (e.g. No.2) and a fixture allocated (e.g. a Galileo IV), the start address ofthis second unit is calculated automatically. If fixture No.1 is a Galileo 1200 (six DMX channels), fixtureNo.2’s start address will be 7. Although this is correct, we suggest that start addresses should be setmanually 20/25 numbers apart, because if fixtures No. 1 and No.2 have to be inverted, the Galileo IV’s16 control channels would overlap with those of the Galileo 1200, making the latter uncontrollable andcompelling the operator to reset the Soft Patch of all the fixtures connected to the Pilot.A start address reset function has been added to further facilitate operators’ work. To enable it, accessSETUP mode (see chapter 7.10 - pag. 19 - Advanced Functions).
GALIL_1 01˛˛˛˛˛˛˛˛˛˛
GALIL_1 01ADDR=001
GALIL_1 01ADDR=____
MAIN MENUSOFT PATCH
![Page 7: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/7.jpg)
page
6
To store the required values, press . once. The following will appear on the display:
. Press to confirm or to abort modification procedure without
carrying out any changes. If you’ve pressed the following will appear: showingthat storage is being carried out.Carry out the entire procedure for every fixture available.To check which fixture is allocated to the keys numbered 1 to 16, access the UNIT MASK function by
pressing . When the message appears, press and then
or use Data Entry to scroll through until the following message appears: . Then
press : the following appears on the display . Now just hold the requiredkey from 1 to 16 down for approximately 3 seconds. One possible result could be as follows:
, showing that the selected fixture is the first Galileo II connected to the Pilot.
UNIT MASKGALIL_2 01
UNIT MASK_________
PROGRAM 01UNIT MASK
MAIN MENUEDIT PROGR
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
3. MANUAL operation
The Pilot 1600 can be operated manually in two ways: with single fixtures or groups of fixtures.Manual operation with one of more fixture can be carried out while records or programs are running.
When the Pilot is running a program or record, press to access manual mode. If no fixtures
have been set for manual control, the following message will flash on the display: and the LED indicating the program or record running during manual operation will remain lit, e.g.
.
NO UNIT
![Page 8: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/8.jpg)
page
7
EN appendiceI D F E
To set the fixture(s) to be controlled manually, press , and hold it down, then select the
required fixture(s) by pressing the keys numbered from to if you wish to controlseveral fixtures manually at the same time.
When is released, the following message appears: . Press to
confirm data storage, or key to abort modification procedure without carrying out any
changes. If you pressed the following will appear: showing that thestorage is being carried out.Supposing that you’ve enabled two Galileo I for manual control, when you access Manual mode, the
following appears: showing that the first of the fixtures stored is a Galileo I (nnnis the value of that function at that moment).
Using the cursor arrows it is possible to gain access to the fixture’s functions (the and
keys in the bottom row), select the fixtures enabled for manual operation (the and keys
in the top row) or gain access to the values of the function shown on the display (the and
keys or Data Entry).
To control all the fixtures enabled for manual control simultaneously, press the and
keys in the top row at the same time. The following will appear: .
To exit manual mode, press again.The group of fixtures under manual control can be reset at any time, as the manual section is run inde-pendently from the others.
GALIL_1 ALIRIS =nnn
GALIL_1 01IRIS =nnn
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
![Page 9: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/9.jpg)
page
8
4. Using the PROGRAM modePilot 1600 can control 16 programs each comprising a maximum of 16 scenes. Each program is pre-pared using 16 fixtures previously configured in the Soft Patch, which can be chosen from the 64 inthe Pilot’s built-in library.
Using the keyboard, select the program : the display will show the number of the program
being run and the current scene: . To pass to the program editing phase, press
on the EDIT keyboard: the display will now show . Press : the
display will show the program being edited ; scrolling with the and
keys or with DATA ENTRY, choose one of the two options: Unit Mask or Edit Scene.
Select Unit Mask first and confirm by pressing : the Program LED will flash and the
following will appear on the display . The LEDs relative to the fixtures enabled in
that program will light up (e.g. ). To add fixtures to the program or remove them, press the
keys to : the enabled fixtures are indicated by lit LEDs, and by pressing and holdingdown one of them for approximately 3 seconds, the type of fixture allocated to that key will be dis-
played, e.g. showing that key No.1 is allocated to a Galileo I fixture. When setting
is finished, press : the following will appear: . Press to confirm
or per abbandonare la sessione di modifica senza eseguire variazioni. Sto abort modificationprocedure without carrying out any changes. If you press ENTER, the following will appear:
showing that storage procedure is being carried out.
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
UNIT MASKGALIL_1 01
UNIT MASK_________
program
PROGRAM 01EDIT SCENE
MAIN MENUEDIT PROGR
PROGR=01SCENE=01
![Page 10: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/10.jpg)
page
9
EN appendiceI D F E
Now proceed with the , function, selected with and or DATA
ENTRY and accessed by pressing . The LED above the Program key will flash and the one
above Scene will light up , and the LED indicating the scene being edited will also belit. If you’ve enabled two Galileo I fixtures for use with this program during the UNIT MASK stage, the
following will appear on the display: showing that the fixture is a Galileo I (nnn isthe value of that function at that point).
Using the cursor arrows it is possible to gain access to the fixture’s functions ( and in
the bottom row), to the fixtures enabled for use ( and in the top row) or the values of
the function shown on the display ( and or Data Entry).
If the fixtures have to carry out the same controls simultaneously, press the and keys
in the top row at the same time. The following will appear: . When two or moreunits have to be controlled simultaneously, all functions must have the same values (e.g. IRIS=255). If
they don’t, the following appears: . Once the scene has been set, pass to the nextone by pressing the relative key or using the COPY function (see relative chapter). When all the neces-
sary scenes have been set, press to store them and the following will appear:
. Press to confirm, or to abort modification procedure withoutcarrying out any changes. If you press ENTER the storage is being carried out.The length of the Program (i.e. the number of scenes it contains) is automatically found by the Pilot1600, which sets the cyclic repetition accordingly: this can be modified by the operator using theSPEED and RATE sliders.Speed is the speed with which the scanner mirrors moves (Pan and Tilt), and Rate is the rate at whichthe unit passes from scene to scene in a program: both can be changed at any time while the programis running.With Speed and Rate at maximum, scenes are changed in sync with the music.
SAVE? Y/NENT/ESC
GALIL_1 ALIRIS =???
GALIL_1 ALIRIS =nnn
GALIL_1 01IRIS =nnn
program
PROGRAM 01EDIT SCENE
![Page 11: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/11.jpg)
page
10
5. Using the Record modePilot 1600 can control 16 records each comprising sequences of programs, including the Speed andRate settings, up to a maximum of 100 steps.
To pass Record editing from the Program mode, press on the EDIT keyboard followed by the
number (using the to keys) of the Program to be edited, then : the follow-
ing will appear: . Scrolling with and or DATA ENTRY, choose
then press the following will appear: . This showsthat the current Step is (ST) 00, made up of Program (PG) 01 with Speed (SP) 00 and Rate (RT) 99.
On the Pilot, the Program LED is lit and the Record LED flashes: .
To change the Program of any given step, press the keys from to , and to changeSpeed and Rate use the relative sliders.When Speed and Rate are set at maximum (99), the scenes automatically change in sync with the
music. The following appears on the display: .
Use and or DATA ENTRY to move from one Record step to another (numbered from 00to 99).
When setting is finished, if you press the following message will appear:
. Press to confirm, or to abort modification procedure without
carrying out any changes. If you press ENTER the following will appear: showingthat the storage is being carried out.
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
ST00 PG01MUSIC SYNC
program
ST00 PG01SP00 RT99
MAIN MENUEDIT REC
MAIN MENUEDIT PROGR
![Page 12: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/12.jpg)
page
11
EN appendiceI D F E
6. COPY functionTo facilitate programming for operators, a data copy function has been included with three differentareas of application: copying programs, scenes and records. The copy function can be aborted without
any changes being made by pressing . To copy a program, you must be in the PROGRAM
function, then press followed by a key from to according to the programto be copied and then the key of the program it’s to be copied to. If you’re copying program 01 to pro-
gram 02, the following will appear on the display: . Press to confirm
and the following will appear: .
To copy a scene, you must be in the SCENE function, then press , followed by a key from
to according to the scene to be copied, then the key of the scene it’s to be copiedto. If you are copying scene 01 to scene 02, the following will appear on the display:
. Press to confirm, and the following will appear: .
To copy a record, you must be in the RECORD function, then press , followed a key from
to according to the record to be copied and then the key of the record it’s to becopied to. If you’re copying record 01 to record 02, the following will appear on the display:
. Press to confirm, and the following will appear .It is possible to disable Copy function in order to not modify the program relized.To enable/disable Copy, see chapter 7.9 (Advanced functions), page 18.
ONE MOMENTUPDATING
COPYR01 TO R02
ONE MOMENTUPDATING
COPYS01 TO S02
ONE MOMENTUPDATING
COPYP01 TO P02
![Page 13: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/13.jpg)
page
12
7. Advanced functionsBy means of these controls, access is gained to important Pilot 1600 functions which allow operatorsto create and control fixture libraries, save settings in a protected memory area and transfer them fromone Pilot to another.
7.1 SetupAccess to this is from the Main Menu, scrolling with and or with DATA ENTRY until the
following appears on the display: . Press to which the reply will be:
. The password for Setup access is 1996, keyed in using the numerical keypad:
then .
7.2 Edit UNLBLThis function allows to allocate a name to one of the fixtures in the library (15 of the 64 are taken up bySGM products).
When you’re in Setup, the following appears on the display: . Press toaccess the name allocation (UNit LaBeL) section.
Using the cursor arrows , access is gained to the library position (
and in the top row), while and in the bottom row operate as cursors and
and or DATA ENTRY change the letters of the name. When setting is finished, press
the following appears on the display: . Press to confirm or
to abort modification procedure without carrying out any changes. If you press ENTER the
following will appear: showing that storage is being carried out.
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
SETUP MENUEDIT UNLBL
SETUPCOD = ____
MAIN MENUSETUP
![Page 14: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/14.jpg)
page
13
EN appendiceI D F E
7.3 Edit EFLBLThis function allows to allocate a name to the effects which fixtures stored in one of the positions ofthe fixture library have.Effect is taken to mean all the functions available on a controllable fixture. For example a scanner suchas a Galileo has Iris, Color, Gobos, Pan and Tilt. Other types of scanners might have more gobo wheelsor color wheels, but some of the above controls are “standard”, so when a name has to be given to afunction, it’s not necessary to define the term (e.g. Pan) every time, and 37 positions available for cus-tom settings are able to ensure a considerable number of updates.
In Setup, the display shows . Press or use DATA ENTRY until the follow-
ing appears on the display then press : access has been gained to thesection for giving names to the effects (EFfect LaBeL).
Using the cursor arrows access is gained to the library position ( and in the top row),
then use and in the bottom row as cursors and the and or DATA
ENTRY to scroll the letters for the new name. When setting is finished, press the following
appears on the display: . Press to confirm or o abort modifica-tion procedure without carrying out any changes. If you press ENTER, the following will appear:
showing that storage is being carried out.
7.4 CFG UnitThis function allows fixtures to be controlled with the Pilot 1600 to be configured.For each fixture, it’s possible to decide how many and which control channels are used and also to givethe fixture a name from the UNLBL library and give its functions names from the EFLBL library.
In Setup, the display shows . Press or use DATA ENTRY until the follow-
ing appears on the display then press .
The following will appear on the display .With and keys in the toprow or DATA ENTRY, the list of 64 configurable fixtures can be scrolled.
CFG UNITGALIL_1
SETUP MENUCFG UNIT
SETUP MENUEDIT UNLBL
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
SETUP MENUEDIT EFLBL
SETUP MENUEDIT UNLBL
![Page 15: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/15.jpg)
page
14
Once the fixture to be configured has been chosen, press the following will appear on the dis-
play: . Using and or DATA ENTRY, choose the number of channels
necessary for controlling the fixture in question, then press . , will appear
on the display, showing that effect No.1 for that fixture is the Iris control. Using and inthe bottom row, scroll through the list of effects to be set.
Use and in the top row to access the setting of the type of change for the effect chosen
(e.g. 01 - Iris), slow (SOFT) or instant effect (HARD), using and keys or DATA ENTRY
to scroll the list of options available: .
By pressing in the top row, access is gained to the definition of 16-bit resolution, which givehigh precision scanner mirror movement, but is useless for functions with instantaneous Cross
(changeover). Using and or DATA ENTRY to scroll the list of options available, the fol-
lowing is reached: .
Using in the top row again, access is gained to the definition of the channel relative to that
effect (e.g. Iris = ch1). Use and or DATA ENTRY to scroll the values available:
. This allows the Pilot to use any fixture configuration, as the functions can besent to the physical channel of the fixture to be controlled, e.g. allocating function 6 to channel 2.If 16-bit resolution has been chosen, a second channel is necessary, normally added to the end of the
effects list. This control will also appear on the display as: . Access to this menu isnot possible with 8-bit resolution.
Pressing in the top row sets the value or position the effects have to assume when fixtures are
in Standby. Use and or DATA ENTRY to scroll through the values available:
. The values available are from 0 to 255, but the UND parameter is also available,which indicates that in the event of the fixture being in Standby, none of the effect’s values arechanged.
GALIL_1STD_BY=UND
GALIL_1CL=8
GALIL_1CH=01
GALIL_1RSL=8 BIT
GALIL_1CROSS=SOFT
GALIL_1E01=IRIS
GALIL_1N_EFF=07
![Page 16: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/16.jpg)
page
15
EN appendiceI D F E
Proceed in the same manner with all the new fixture’s effects, then press until the following
message appears: . Press to confirm or to abort modificationprocedure without carrying out any changes. If you press ENTER, the following will appear:
showing that storage is being carried out.
7.5 CFG ResVALThis function allows operators to choose which channel controls the Remote Reset function whichsome fixtures have.
In Setup, the display shows . Press or use DATA ENTRY until the follow-
ing appears then press .
Then use and or DATA ENTRY to select the necessary value, which appears on the dis-play:
- nnn is the necessary value. If ??? appears on the display for some fixtures, thismeans that the function is not enabled.
If any changes have been made, when : is pressed, the following will appear:
. Press to confirm or to abort modification procedure without
carrying out any changes. If you press ENTER the following will appear: showingthat storage is being carried out.
7.6 CFG LMPVALThis function allows operators to decide which channel controls the remote switching on of the lampby means of a command on a special DMX channel which some fixtures have.
In Setup, the following appears: . Press or use DATA ENTRY until the fol-
SETUP MENUEDIT UNLBL
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
GALIL_1RES_VL=nnn
SETUP MENUCFG RESVAL
SETUP MENUEDIT UNLBL
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
![Page 17: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/17.jpg)
page
16
lowing appears then press .
Then use and or DATA ENTRY to select the necessary value, which appears on the dis-
play: - nnn is the necessary value. If ??? appears on the display for some fix-tures, this means that the function is not enabled.
If any changes have been made, when is pressed, the following will appear:
. Press to confirm or to abort modification procedure without
carrying out any changes. If you pressed ENTER the following will appear: show-ing that storage is being carried out.
7.7 Store & Load fileThis function enables Pilot 1600 configuration data to be stored in a Flash EPROM area of the con-troller’s memory. Work data is normally stored in another part of the memory.It is therefore advisable to save the data every time changes are made to the configuration or to theSoft Patch to avoid loosing the work done.
In Setup, the following appears . Press or use DATA ENTRY until the fol-
lowing appears then press . The following will appear:
showing that storage is being carried out.
The Load function allows to recover Pilot 1600 configuration data from the Flash EPROM memory.This is extremely useful when the controller’s used in various situations and it’s necessary to return tothe ideal conditions previously saved in the memory.
In Setup, the following appears . Press or use DATA ENTRY until the fol-
SETUP MENUEDIT UNLBL
ONE MOMENTUPDATING
SETUP MENUSTORE FILE
SETUP MENUEDIT UNLBL
ONE MOMENTUPDATING
SAVE? Y/NENT/ESC
GALIL_1RES_VL=nnn
SETUP MENUCFG LMPVAL
![Page 18: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/18.jpg)
page
17
EN appendiceI D F E
lowing appears then press .
The following will appear: : pressing confirms file loading, aborts the operation.
7.8 Backup & RestoreThis function allows the data stored in the unit’s memory to be transferred to another Pilot 1600.Instead of manually repeating all the configuration work, anybody with a unit with new fixtures storedin it can make use of this useful facility.Just connect the two Pilot 1600 units using the DMX connectors, then enable the BACKUP function onthe one which has to transmit the data and the RESTORE function on the one which has to receive it.
ATTENTION: enabling the Restore function without connecting to another Pilot 1600which transfers the data cause the complete cancellation of the Pilot which has to be pro-grammed!
In Setup, the following appears . Press or use DATA ENTRY until the fol-
lowing appears , then press . The following will appear:
. Pressing confirms data transfer and aborts the operation.
During transfer, the following appears on the display: , and at the end of the oper-
ation .
In Setup, the display of the unit which has to receive the data shows : press
or use DATA ENTRY until the following appears , then press . The
following will appear: . Pressing confirms data transfer and
CONFIRM?ENT/ESC
SETUP MENURESTORE
SETUP MENUEDIT UNLBL
TRANSFEREND
TRANSFERON
TR ? (Y/N)ENT/ESC
SETUP MENUBACKUP
SETUP MENUEDIT UNLBL
SURE ??ENT/ESC
SETUP MENULOAD FILE
![Page 19: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/19.jpg)
page
18
aborts the operation.Before enabling reception, the “virgin” Pilot cancels its memory. The following appears on the display:
. Press to cancel:
appears on the display, then
. Pressing enables data recep-tion. If the operation is carried out perfectly
will appear: if not showing that the operation must be repeated.
7.9 Menu & Copy enable/disableThis function blocks access to the programming MENU and the COPY function, making it impossiblefor any unwanted changes to be made to PROGRAMS and RECORDS.
To enable this protection, press the following keys and hold them down for 8 seconds:
+ + . The display shows . At this point, if the MENU key is pressed,
this message appears on the display: , and if COPY is pressed,
appears. Pressing + + and holding them down again for 8seconds restores normal operating conditions, and the following appears on the display:
.
MENU COPYENABLE
sceneCOPY KEYIS DISABLE
MENU KEYIS DISABLE
MENU COPYDISABLE
scene
TRANSFERERROR
TRANSFERGOOD
READY TORECEIVE
ERASEFLASH
ER ? (Y/N)ENT/ESC
ATTENTION: while STORE procedure isat operators’ discretion, LOAD is auto-matic (it may also be carried out manu-ally). Every time the Pilot 1600 isswitched on, the control softwarereloads the contents of the unit’s flashmemory into the work memory.REMEMBER TO SAVE THE DATA WHEN YOU FINISH
PROGRAMMING!
![Page 20: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/20.jpg)
page
19
EN appendiceI D F E
7.10 Patch resetThis function allow fixtures’ addresses to be reset at parameters which are considered “ideal”, reset-ting al the start address in groups of 25, starting with unit 1. As already said, this space of 25 channelsallows fixtures being controlled to be easily changed without having to worry about moving adjacentunits whose control channels might overlap those of a new unit, causing faulty operation.
When SETUP is accessed, the display shows , press or use DATA ENTRY
until the following appears on the display: , then press . The following
appears on the display: . At this point, press to confirm the “reset”, or
to abort the procedure.
SURE ??ENT/ESC
SETUP MENUPATCH RST
SETUP MENUEDIT UNLBL
![Page 21: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/21.jpg)
page
20
8. Remote fixture controls
8.1 Remote reset
For access to the remote functions of those fixtures which have this control, just press , and
hold it down for about 3 seconds: then use and keys until .
appears on the display. Then just press the key relative to the fixture or unit to be reset, e.g. . Ifthe relative LED lights up, this shows that the reset has been carried out; if not the unit chosen cannotbe reset remotely.
8.1 Remote lamp On/Off
For access to the remote functions of those fixtures which have this function, just press and
hold it down for about 3 seconds: then use and until appears on
the display. Then press the key relative to the fixture or unit to be reset, e.g. . If the relativeLED lights up or goes off, this shows that the reset has been carried out; if not, the unit chosen doesn’thave this facility.
LAMPON
RESETUNIT
![Page 22: Pilot 1600 Manual-En](https://reader036.fdocuments.us/reader036/viewer/2022081719/557211d2497959fc0b8f8b26/html5/thumbnails/22.jpg)
cod.
M00
1145
Via Pio La Torre, 1 • 61010 TAVULLIA (PS) • ITALY •Tel. +39 0721476477 • Fax +39 0721476170
www.sgm.it • [email protected]