PIKA Technologies Inc. Digital Logger Application Sample April 2010.

15
PIKA Technologies Inc. Digital Logger Application Sample April 2010

Transcript of PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Page 1: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

PIKA Technologies Inc.Digital Logger Application Sample

April 2010

Page 2: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

What is it?

• Sample Application developed in C++ and C#• Can be used to passively record calls from Digital

T1/E1 spans• Works on HMP 2.8+ platforms (Windows, Linux) with

PIKA Digital PCIe Boards• Files can be saved in .wav or raw formats

Page 3: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Overall Architecture Description

• At start-up the main thread will create all the required instances. It will therefore create the digital board instance and its associated members.

• Each instance will communicate with the PIKA Driver (PKH_XXX) to configure and start it’s associated objects.

• The main thread will then spawn the event thread.

• The event thread is used to handle asynchronous events from the PIKA driver.

• For debugging purposes an event message logger (not to be confused with the digital logger) has been included to show events on the console and can also be injected to the PIKA Driver logs.

• The DigitalBoard instance contains 4 span instances and up to 2*30 calls. A particular call is associated to 1 channel for each of 2 spans. We should note that signalling channels are created but are not actually started.

• Each Span instance contains 1 hdlc and up to 30 channels.

Page 4: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Getting Started

• Install the PIKA Low Level HMP API on a PC ( 2.8.x or newer ) as described in the Getting Started Guide

• Remove the line jumpers on the PIKA HMP PCIe digital board.

• Install the board in the PC• Cabling - requires some specific wiring• Download, Compile, and run the Digital Logger

application

Page 5: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Sample Code - Overall Architecture

• At start-up, the sample application will statically create all of the resources needed to Passively Record on all channels and spans

• The event thread handles asynchronous events from the PIKA driver.

• For debugging purposes an event message logger (not to be confused with the digital logger) has been included to show events on the console and can also be injected to the PIKA Driver logs. There are multiple debug levels that can be controlled via a compile flag.

• A 4 span board can log 2 T1 or E1 connections

• Each Span uses an HDLC to capture ISDN messages and via the PIKA Low Level API, these messages get sent to the application for processing.

Page 6: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Overall Architecture Description

• The Hdlc instance is used to handle incoming ISDN Q.921/Q.931 messages. When a valid Q.931 message is decoded (cisdntranscoder.cpp), the channel detected shall setup a call.

• The call will then start listening to the conference between the 2 previously associated channels and output the conversation to a file. The filename will have the following format:

• Board_#_Call_#_$date$.extension

• When a ISDN Disconnect or Release message is detected, the audio file will be saved and closed.

• It is also possible to copy the audio buffers to the application. This can then be used to listen to the conversation in a live session.

Page 7: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Digital

Logger API

Application thread Diagram

Main

Application

Digital Logger

Event Thread

PIKA DriverSpawn

Thread

PKH_BOARD_XXX

PKH_SPAN_XXX

PKH_CHANNEL_XXX

Application

Event Thread

DL_Initialize

DL_SetCallAudioBufferCB

Spawn

Thread

DL_SetCallAudioBufferCB

DL_WaitOnEvent

DL_WaitOnEventSerialized

Audio function CB

DL_Start

DL_Stop

DL_Cleanup

PKH_ Wait On

Event

Page 8: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Using the Digital Logger API

There are different APIs available (for windows)

1) Compile all source into an application• DL_XXX : include digitallogger.h

2) Compile application with DLL• PKDL_XXX : include DigitalLoggingDll.h

3) Compile application in C#• Use namespace DigitalLogger in DigitalLogger.cs

Page 9: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

API call scenario

• Main Application thread• DL_Initialize(tApplicationConfiguration config) // Initialize system• DL_SetCallAudioBufferCB(Pf_callAudioBufferCB func) // Set callback if you want to listen to live audio• Create an event thread and call DL_WaitOnEvent(PK_UINT timeout, tApplicationEvent *event) • DL_Start() // Start the system

• A Call is triggered from the CO

• Application Event Thread• DL_WaitOnEvent returns EVENT_CALLSETUP, SpanId1 specifies the span origin• DL_WaitOnEvent returns EVENT_CALLCONNECT

• Digital Application Wrapper• The call will be recorded in an audio file• The Audio Buffer Call Back will the called with the audio buffer

• The Call is hung up

• Application Event Thread• DL_WaitOnEvent returns EVENT_CALLRELEASE

• Digital Application Wrapper• The recorded file is closed

• Main Application thread• DL_Stop() // Stop the system• Stop Application thread• DL_Cleanup // Cleanup the system

Page 10: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

DigitalBoard

Class Hierarchy and containment

Span

Channel

Hdlc

Call

BaseEntity

LogClient Logger (singleton)

1

4

1

1

30

2*30

System

1

n

Page 11: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Passive Logging

1

0

2

3

HDLC

HDLC

HDLC

HDLC

MediaProcessing

Passive Logging – ApplicationCall Logs

AudioFiles

ProcessISDN MessagesPKH_SPAN_HDLC_X Audio

Record

HMP Digital Board - PCIe

CO

PBX

T1/E1Span

RX- Tip/Ring

RX- Tip/Ring

TX RX

TXRX

Jumpers

Page 12: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Passive Logging Architecture

COTX

RXPBX TX

RX

RX RX

HDLC HDLCAudioAudio

M M

Conf

M

Record

File

ISDN

Events

ISDN

Events

Tip / Ring Tip / Ring

Page 13: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Passive Logging – Cabling

PBX

Telco

TX Tip

TX Ring

TX Tip

TX Ring

RX Tip

RX Ring

RX Tip

RX Ring

RX

TIP

RX

RING

TX

TIP

TX

RING

RX

TIP

RX

RING

TX

TIP

TX

RING

Span 0Span 1

Do No

Connection

Do No

Connection

PIKA Digital T1/E1 HMP Board - PCIe

Page 14: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Call/Span/Channel allocation

0 1 2 3 2

8

2

9

3

0

3

1

Span 1

0 1 2 3 2

8

2

9

3

0

3

1

Span 2

0 1 2 3 2

8

2

9

3

0

3

1

Span 3

0 1 2 3 2

8

2

9

3

0

3

1

Span 4

0

32Call Ids

1

33

2

34

3

35

28

60

29

61

30

62

31

63

Page 15: PIKA Technologies Inc. Digital Logger Application Sample April 2010.

Where can I find it?

• The Source code is located under:• http://svn.pikatech.com/customercare/trunk/samples/DigitalLogger/

• Some additional info:• http://forum.pikatechnologies.com/showthread.php?t=170

• ./docs/README.rtf