PIEZORESISTIVE PRESSURE TRANSMITTERS S 23 S / 25 S · 2018-09-14 · PIEZORESISTIVE PRESSURE...

2
PIEZORESISTIVE PRESSURE TRANSMITTERS ABSOLUTE AND GAUGE PRESSURE SERIES 23 S / 25 S This transmitter is well suited for use in industrial applications that require good accuracy and high stability. It is designed especially for safety critical applications where media compatibi- lity is paramount. The Series 23S / 25S features a fully welded pressure port construction, no internal O-Rings or seals are used up to 600 bar. The wetted materials are a 316L stainless steel housing and a brazed diaphragm. · Series 23 S Male pressure port G1/4” Accuracy 0,25 %FS (best straight line), optional 0,1 %FS · Series 25 S G1/2” pressure port with flush diaphragm Accuracy 0,25 %FS (best straight line), optional 0,1 %FS A Comprehensive Range Absolute, barometric, gauge (positive and negative pressures). 16 nominal pressure ranges. Current or voltage output. Flexibility A modular concept is used, with fast and economical production achieved by using off-the-shelf Series 7 S and 9 S capsules and Series 6 S sensors. Numerous options and variations are available to meet customers’ specific requirements: Pressure ranges, pressure ports, signal outputs, electrical connectors, etc. Quality Each transmitter is subjected to severe test- and calibration procedures. Transmitters are manu- factured and tested according to ISO 9001:2000. Series 23 S Series 25 S ø 18,6 HEX 22 ø 21 12 2 10 ca. 47 G 1/4" Series 23 S (600 bar) Eolastic ® -seal (Viton) G 1/4" ø 0,6 HEX 24 Binder ø 18,6 12 2 8 max. 55 25 ø 26 ø 21 1 Series 23 S (> 600 bar) Eolastic ® -seal (Viton) Series 25 S (50 bar) G 1/2" ø 17 5 10 max. 55 HEX 27 16,7 ø 21 USIT-Ring (Nitril) PA-25 TAB (100 bar) G 1/2" ø 18 ø 15 ø 26,8 ø 22 2 14 3 10 max. 35 9,5 HEX 27 Binder Eolastic ® -seal (Viton) Villar, 22 · 2º 2ª - 08041 Barcelona - t: 934 508 777 - e: [email protected] - www.catsensors.com

Transcript of PIEZORESISTIVE PRESSURE TRANSMITTERS S 23 S / 25 S · 2018-09-14 · PIEZORESISTIVE PRESSURE...

Page 1: PIEZORESISTIVE PRESSURE TRANSMITTERS S 23 S / 25 S · 2018-09-14 · PIEZORESISTIVE PRESSURE TRANSMITTERS ABSOLUTE AND GAUGE PRESSURE SERIES 23 S / 25 S This transmitter is well suited

PIEZORESISTIVE PRESSURE TRANSMITTERS ABSOLUTE AND GAUGE PRESSURE

SERIES 23 S / 25 S

This transmitter is well suited for use in industrial applications that require good accuracy and high stability. It is designed especially for safety critical applications where media compatibi-lity is paramount. The Series 23S / 25S features a fully welded pressure port construction, no internal O-Rings or seals are used up to 600 bar. The wetted materials are a 316L stainless steel housing and a brazed diaphragm.

· Series 23 S Male pressure port G1/4” Accuracy 0,25 %FS (best straight line), optional 0,1 %FS

· Series 25 S G1/2” pressure port with flush diaphragm Accuracy 0,25 %FS (best straight line), optional 0,1 %FS

A Comprehensive Range

Absolute, barometric, gauge (positive and negative pressures). 16 nominal pressure ranges. Current or voltage output.

Flexibility

A modular concept is used, with fast and economical production achieved by using off-the-shelf Series 7 S and 9 S capsules and Series 6 S sensors. Numerous options and variations are available to meet customers’ specific requirements: Pressure ranges, pressure ports, signal outputs, electrical connectors, etc.

Quality

Each transmitter is subjected to severe test- and calibration procedures. Transmitters are manu-factured and tested according to ISO 9001:2000.

Series 23 S

Series 25 S

ø 18,6

HEX 22

ø 21

122

10ca

. 47

G 1/4"

Series 23 S (≤600 bar)

Eolastic®-seal(Viton)

G 1/4"ø 0,6

HEX 24

Binder

ø 18,6122

8m

ax. 5

525 ø 26

ø 21

1

Series 23 S (> 600 bar)

Eolastic®-seal(Viton)

Series 25 S (≤50 bar)

G 1/2"ø 17

5

10 m

ax. 5

5 HEX 27

16,7

ø 21

USIT-Ring (Nitril)

PA-25 TAB (≥ 100 bar)

G 1/2"ø 18ø 15

ø 26,8

ø 22

214

310

max

. 35

9,5

HEX 27

Binder

Eolastic®-seal(Viton)

Villar, 22 · 2º 2ª - 08041 Barcelona - t: 934 508 777 - e: [email protected] - www.catsensors.com

Page 2: PIEZORESISTIVE PRESSURE TRANSMITTERS S 23 S / 25 S · 2018-09-14 · PIEZORESISTIVE PRESSURE TRANSMITTERS ABSOLUTE AND GAUGE PRESSURE SERIES 23 S / 25 S This transmitter is well suited

KELLERSpecifications

Pressure Ranges (FS) in Bar

PR-23 S / PR-25 S G1/2” -1 -0,5 -0,2 0,2 0,5 1 2 5 10 20 PAA-23 S / PAA-25 S G1/2” 0,5 1 2 5 10 20 PA-23 S 1 2 5 10 20 50 100 200 400 600 1000PA-25 S / PA-25 TAB G1/2” 1 2 5 10 20 50 100 200 400

Overpressure -1 -1 -1 2,5 2,5 3 4 10 20 40 100 200 300 600 900 1200PAA: Absolute. Zero at vacuum PA: Sealed Gauge. Zero at 1000 mbar abs PR: Vented Gauge. Zero at atmospheric pressure

Linearity(1) + Hysteresis + Repeatability ± 0,25 %FS ± 0,5 %FS (Range ≤ 1 bar) (1) best straight lineStorage-/Operating Temperature -40…100 °CCompensated Temperature Range -10…80 °CTemperature Coefficients of Zero, in %FS/°C of Sensitivity, in %/°C · Range > 1 bar 0,005 typ. 0,01 max. 0,02 max. · Range 1 bar 0,010 typ. 0,02 max. 0,02 max. · Range 0,5 bar 0,015 typ. 0,03 max. 0,02 max. · Range 0,2 bar 0,025 typ. 0,05 max. 0,02 max.Stability · Range > 2 bar 0,1 %FS typ. 0,2 %FS max. · Range ≤ 2 bar 2 mbar typ. 4 mbar max.

Signal Output / Type 4...20 mA / 2-Wire 0…5 V / 3-Wire* 0...10 V / 3-Wire*Supply 8...28 VDC 8…28 VDC 13...28 VDCLoad Resistance (Ω) (U-10 V) / 0,02 A > 5 k > 5 kFrequency Response 5 kHz 1 kHz 1 kHzPower Consumption max. 5 mA max. 5 mA Electrical Connector Plug DIN 43650Dead Volume Change < 0,1 mm3

Material in Media Contact Stainless steel 316L (DIN 1.4435), hard solderProtection Class IP65Weight Series 23 S: ≈ 105 g Series 25 S: ≈ 115 gInsulation > 100 MΩ@500 VEndurance > 10 million cycles, 0…100 %FS at 25 °COil Filling Silicone fluid

Options Pressure Port On request. Electrical Output Cable, other plug connections.Pressure Ranges On request.Oil Filling Fluorocarbon oil (O2-compatible), olive-oil, low temperature oil.

Also available in Ex-version; see separate data sheet 23(S)Ei / 25(S)Ei / 26 Ei.

⊕ 50 mV

5V/10V

1%FS FS

Signal bei Null für 0…5 V (0…10 V) Transmitter* Signal at zero for 0…5 V (0…10 V) transmitters

2-Wire 3-Wire DIN 43650, CableTransmitter Transmitter Binder-Plug

- GND 1 white

OUT/GND +OUT 2 red

+Vcc +Vcc 3 black

3-Wire0…5 V / 0…10 V

2-Wire4…20 mA

blac

k

whi

te red

blac

k

red

Load

SIGNAL

+

-

GND GND+ +13…28 V 8…28 V

ELECTRICAL CONNECTIONS T R A N S M I T T E R

S U P P L Y

KELLER AG für Druckmesstechnik St. Gallerstrasse 119 CH-8404 Winterthur Tel. +41 (0)52 - 235 25 25 Fax +41 (0)52 - 235 25 00KELLER Ges. für Druckmesstechnik mbH Schwarzwaldstrasse 17 D-79798 Jestetten Tel. +49 (0)7745 - 9214 - 0 Fax +49 (0)7745 - 9214 - 60

Companies approved to ISO 9001:2000 www.keller-druck.com

Subject to alterations 04/07