GRAPHIC SYMBOL FOR INSTRUMENTATION ITEMS
SYMBOL DESCRIPTION
DEVICE MOUNTED ON PANEL
BOARD OR PANEL MOUNTED DEVICE - DEVICE MOUNTED INSIDE PANEL
FIELD OR LOCALLY MOUNTED DEVICE
PROGRAMMED FUNCTION NOT NORMALLY ACCESSIBLE TO OPERATOR
PROGRAMMED FUNCTION ACCESSIBLE THROUGH OPERATOR'S INTERFACE DEVICE
PLC INPUT OR OUTPUT POINT
XOR
A
INTERLOCKING
EXCLUSIVE OR
ALTERNATOR
OR
OR
AND
AND
S
MOTOR STARTER
P
PURGE
L
COMPLEX LOGIC
COMPUTER LOGIC SYSTEM
TERMINAL OR TRANSITION POINT
FLOAT SWITCH
PARTIAL FLUME
MIXER
SEAL
OFF PAGE CONNECTOR
PROCESS MACHINERY MOTOR
VENTURI OR INSERT FLOW TUBE
IN-LINE FLOW ELEMENT (PROPELLER TYPE)
IN-LINE FLOW ELEMENT (MAGNETIC TYPE)
IN-LINE FLOW ELEMENT (ULTRA SONIC)
FLOW ORIFICE
TURBIDITY METER
ROTOMETER
PUMP
BLOWER
GENERAL USE DISCONNECTING SWITCH
TIME CLOSED CONTACT ON ENERGIZATION
TIME OPENED CONTACT ON ENERGIZATION
TIME OPENED CONTACT ON DE-ENERGIZATION
TIME CLOSED CONTACT ON DE-ENERGIZATION
FLOAT ACTUATED SWITCH - NO
FLOAT ACTUATED SWITCH - NC
PRESSURE ACTUATED SWITCH - NC
PRESSURE ACTUATED SWITCH - NO
FLOW ACTUATED SWITCH - NO
FLOW ACTUATED SWITCH - NC
TEMPERATURE SWITCH - NO
TEMPERATURE SWITCH - NC
LIMIT SWITCH (PROXIMITY TYPE) - NORMALLY OPEN
LIMIT SWITCH (PROXIMITY TYPE) - NORMALLY OPEN - HELD CLOSED
LIMIT SWITCH (PROXIMITY TYPE) - NORMALLY CLOSED - HELD OPEN
LIMIT SWITCH (PROXIMITY TYPE) - NORMALLY CLOSED
CONTROL RELAY CONTACT - NORMALLY OPEN
CONTROL RELAY CONTACT - NORMALLY CLOSED
LIGHTING ARRESTOR
ETI
ELAPSED TIME INDICATOR
SYMBOL DESCRIPTION
T
TIMING RELAY COIL
TIMING RELAY COIL (OFF DELAY)
1
T
G
INDICATING LIGHT
PUSH-TO-TEST INDICATING LIGHT
BATTERY
X1 X2
SECONDARY TRANSFORMER
VARIABLE RESISTOR
RESISTOR
MOLDED CASE CIRCUIT BREAKER
SPEED SWITCH
MOMENTARY PUSHBUTTON OPERATOR - NORMALLY CLOSED
MOMENTARY PUSHBUTTON OPERATOR - NORMALLY OPEN
SELECTOR SWITCH - NORMALLY OPEN
PUSHBUTTON OPERATOR WITH MUSHROOM HEAD
SOLENOID OR CLUTCH
THERMAL OVERLOAD
FIELD LOCATED
TERMINAL POINT
LOW VOLTAGE FUSE
FUSIBLE TERMINAL BLOCK
CIRCUIT BREAKER WITH STAB CONNECTION
CONTROL POWER TRANSFORMER
TWO COIL LATCHING RELAY
CR
L
CR
U
RECEPTACLE
SELECTOR SWITCH OPERATOR WITH FUNCTION SHOWN
HAND
OFF
AUTO
FOC
FOPP
FOC-DI(X)
FOC-DO(X)
FOC-AI(X)
FOC-AO(X)
DISCRETE INPUT TO FIBER CONVERTER (PROVIDE WITH 120VAC P/S FIBER
CONVERTER TO DISCRETE OUTPUT (PROVIDE WITH 120VAC P/S (WEED EOTEC -
2S07/2H07 WITH 120 VAC P/S) QUANTITY (X) AS NOTED ON DRAWINGS
ANALOG INPUT TO FIBER CONVERTER
FIBER CONVERTER TO ANALOG INPUT (WEED EOTEC 2T14/2R14 WITH POWER SUPPLY
AS REQUIRED) QUANTITY (X) AS NOTED ON DRAWINGS
FIBER OPTIC CONVERTER - TYPE AND STYLE AS NOTED
FIBER OPTIC PATCH PANEL CONNECTORS AND QUANTITY AS NOTED
1I
0117
PROCESSOR #1, INPUT RACK 0, SLOT (OR GROUP) 1, BIT 17
EXAMPLE OF P&ID I/O SYMBOL
NOTE: THE PLC I/O ADDRESS SHALL BE USED AS THE
WIRING TAG SCHEME FOR ALL PANEL AND FIELD
CONTROL WIRING. COORDINATE WITH ELECTRICAL
CONTRACTOR.
GRAPHIC SYMBOLS FOR VALVES
SYMBOL DESCRIPTION
PLUG VALVE
PNEUMATIC DIAPHRAGM OR POSITIONER (THROTTLING)
PNEUMATIC DIAPHRAGM OR POSITIONER (OPEN-SHUT)
STROKE OR POSITION ACTUATOR CYLINDER (THROTTLING)
STROKE OR POSITION ACTUATOR CYLINDER (OPEN-SHUT)
MOTOR OPERATED (THROTTLING)
MOTOR OPERATED (OPEN - SHUT)
SLIDE-STOP GATE
SLUICE GATE
AIR SET ASSEMBLY
BALL VALVE
GLOBE VALVE
GATE VALVE OR KNIFE GATE
CHECK VALVE
BUTTERFLY VALVE, DAMPER OR LOUVER
TWO - WAY SOLENOID VALVE OPERATOR
ELECTRONICALLY CONTROLLED CHECK VALVE
TWO - WAY SOLENOID VALVE OPERATOR - DETENTED
THREE - WAY SOLENOID VALVE OPERATOR
FOUR - WAY SOLENOID VALVE OPERATOR
MANIFOLD STYLE BLOCK I/O SOLENOID VALVE - DUAL COILS
ABBREVIATIONS
SYMBOL DESCRIPTION
R RESET
T TRIP
AS AIR SUPPLY
DO DISSOLVED OXYGEN
GS GAS SUPPLY
HS HYDRAULIC SUPPLY
NS NITROGEN SUPPLY
ORP OXYGEN REDUCTION POTENTIAL
SS STEAM SUPPLY
SP SET POINT
WS WATER SUPPLY
PV PROCESS VARIABLE
F.O. FAIL OPEN
F.C. FAIL CLOSE
SBPP SCREEN BUILDING PROCESSOR PANEL
TFBMPP TERTIARY FILTER BUILDING MAIN PROCESSOR PANEL
HVACP HEATING VENTILATION AIR CONDITIONING CONTROL PANEL - I/O
MD MAIN DISCONNECT
GAIN OR PROPORTIONAL CONTROL
INTEGRAL OR RESET CONTROL
D DERIVATIVE OR RATE CONTROL
%
V VELOCITY ALGORITHM
1-0 ON - OFF CONTROL
ã
SQUARE ROOT EXTRACTOR
ɆADD OR TOTALIZE
Δ SUBTRACT OR DIFFERENCE
> HIGHEST MEASURED VARIABLE
< LOWEST MEASURED VARIABLE
E/I , I/PCONVERT ONE TO ANOTHER
* , /MULTIPLY, DIVIDE
ÑBIAS OR REVERSING
f(x) CHARACTERIZE - (EQUATION / /D/%/ETC.)
SYMBOL DEMOLITION
INSTRUMENTATION LINE SYMBOLS
ELECTRICAL SIGNAL
AIR LINE/PNEUMATIC SIGNAL
HYDRAULIC SIGNAL
ELECTROMAGNETIC OR SONIC SIGNAL
SOFTWARE SIGNAL
CONNECTION TO PROCESS, OR MECHANICAL LINK
ETHERNET COMMUNICATION SIGNAL-UNSHIELDED TWISTED PAIR (UTP)-SPEED
AS INDICATED
ETHERNET FIBER OPTIC COMMUNICATIONS SIGNAL
PLC REMOTE I/O FIBER OPTIC COMMUNICATION SIGNAL
ETHERNET VIDEO FIBER OPTIC
I.S.A. STANDARD LETTER FUNCTIONS
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
ANALYSIS, ANALOG
BURNER, FLAME
CONDUCTIVITY, COMMAND
DENSITY, SPECIFIC GRAVITY
VOLTAGE
FLOW RATE
GAGING
HAND, MANUAL
CURRENT
POWER
TIME, TIME SCHEDULE
LEVEL, LIGHT
MOISTURE, HUMIDITY
OVERLOAD
PRESSURE, VACUUM
QUANTITY
RADIOACTIVITY
SPEED, FREQUENCY, SOLENOID
TEMPERATURE, TURBIDITY
MULTIVARIABLE
VIBRATION, VISCOSITY
WEIGHT, FORCE
POSITION
ALARM
BATCH
CONTROL (FEEDBACK TYPE)
PRIMARY ELEMENT
RATIO
GLASS
HIGH
INDICATE
SCAN
CONTROL (NO FEEDBACK)
LOW
MIDDLE, MODULATE
ORIFICE
POINT
TOTALIZE, INTEGRATE
RECORD, PRINT, RECEIVE
SWITCH
TRANSMIT, TRANSFORM
MULTIFUNCTION
VALVE, DAMPER, LOUVER
DRIVE, ACTUATE
RELAY, COMPUTE
SYMBOL FIRST LETTER SUCCEEDING LETTERS
INPUT POINT
XXX
EXISTING PANEL TERMINAL
NUMBER AND FIELD WIRING
WHICH CONTRACTOR SHALL
FIELD VERIFY
XXX
D
01 I1OO1
XXX XXX
0120101
WHICH CONTRACTOR SHALL
NUMBER AND FIELD WIRING
EXISTING PANEL TERMINAL
FIELD VERIFY
OUTPUT POINT
OUTPUT RACK 1,
SLOT 2, BIT 01
SLOT 0, BIT 01
INPUT RACK 1,
1. PRIOR TO SUBMITTING A BID FOR THE WORK DETAILED UNDER THIS CONTRACT, BIDDER SHALL VISIT THE REMOTE SITES. THE BIDDER SHALL
FULLY ACQUAINT ONESELF WITH EXISTING FIELD CONDITIONS AT EACH SITE. NO BULLETINS WILL BE WRITTEN FOR WORK DUE TO LACK OF
VERIFICATION OF EXISTING SITE CONDITIONS AND WIRING.
2. NO WIRES SHALL BE TERMINATED TO TERMINAL STRIPS, OR OTHER EQUIPMENT WITHOUT FIRST VERIFYING SIGNAL TYPE. DAMAGES
RESULTING IN LACK OF VERIFICATION SHALL BE BORNE BY THE CONTRACTOR. CONTRACTOR SHALL COORDINATE SIGNAL TYPE AND
VOLTAGE WITH I/O CARDS SHOWN.
3. WITHIN CONTROL PANELS, NAMEPLATES SHALL BE PROVIDED TO INDICATE DIFFERENT VOLTAGE LEVELS WITHIN PANELS. ALSO, A NAME
TAG (YELLOW BACKGROUND, RED LETTERING) SHALL BE LOCATED ON THE FRONT OF EVERY PANEL INDICATING THAT WHEN MAIN PANEL
DISCONNECTED 120V IS STILL PRESENT FROM FIELD DEVICES (YELLOW WIRING/ISOLATED INPUT CARDS.)
4. PHENOLIC TAGS ON FACE OF CONTROL PANELS TO HAVE WHITE BACKGROUND AND BLACK LETTERING (EXCEPT WARNING TAGS; YELLOW
BACKGROUND RED LETTERING).
5. PROVIDE SAFETY COVERS ON ALL 480V MOLDED CASE MAIN CIRCUIT BREAKERS TO INSULATE THE INCOMING CABLES AND SIDE
CONDUCTORS FROM CONTACT. (TYP. FOR ALL CONTROL PANELS.) PROVIDE BREAKER LOCKS FOR ALL PUMP CIRCUIT BREAKERS (MCP)AND
MAIN PANEL BREAKERS.
6. REFER TO WIRING DIAGRAMS FOR ADDITIONAL INFORMATION ON ISOLATED I/O. A COMMON NEUTRAL MAY BE USED FOR SEVERAL ISOLATED
INPUTS FROM THE SAME STARTER. PROVIDE NEUTRAL JUMPERS WIRES WITHIN THE PANEL AS REQUIRED.
7. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN LIGHT LINE WEIGHTS ON THE DRAWINGS ARE EXISTING ITEMS TO REMAIN.
ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN HEAVY LINE WEIGHTS ARE NEW THIS CONTRACT.
8. ITEMS SHOWN CROSSHATCHED (OR NOTED TO BE DEMOLISHED) ON THE DRAWINGS ARE EXISTING ITEMS TO BE REMOVED, FROM SITE BY
CONTRACTOR.
9. INSTALL A SINGLE CONDUCTOR INSULATED (RHW, THHN, OR XHHW) COPPER GROUND WIRE IN EACH CONDUIT, SIZE AS SHOWN ON
DRAWINGS, OR AS A MINIMUM PER THE NATIONAL ELECTRICAL CODE. THIS GROUND WIRE SHALL BE CONNECTED AT EACH END TO THE
EQUIPMENT GROUND. THIS ALSO INCLUDES INSTRUMENTATION DEVICES SUCH AS LEVEL, PRESSURE, FLOW TRANSMITTERS, LIMIT
SWITCHES, CONDUITS, NETWORK AND I/O CABLES.
10. THE FOLLOWING EXAMPLE COMPONENT IDENTIFICATION SHALL BE USED AS APPROPRIATE:
(F) FIELD MOUNTED, NOT AT STARTER OR OTHER CONTROL PANELS
(S) STARTER PANEL MOUNTED
(MCP) AT MAIN CONTROL PANEL
(1) AT CONTROL PANEL NO.1
(2) AT CONTROL PANEL NO.2
(TCP) AT TEMPERATURE CONTROL PANEL
11. REFER TO DETAIL SHEETS. CONTRACTOR SHALL FURNISH AND INSTALL HARDWARE AND APPURTENANCES (I.E. PIPE TAPS, WETWELL
BUBBLER TUBES, VALVES, COPPER TUBING, BALL VALVES, PNEUMATIC PIPING, SPOOL PIECES, ETC.) FOR FIELD DEVICES SHOWN
(FLOWMETERS, PRESSURE TRANSMITTERS, LEVEL TRANSMITTERS, ETC.). WORK SHALL BE COORDINATED WITH OTHER TRADES
(MECHANICAL INSTRUMENTATION, ETC.) CONTRACTOR SHALL BE RESPONSIBLE FOR SYSTEM COORDINATION AND INSTALLATION.
12. ETHERNET AND FIBER OPTIC TERMINATIONS SHALL BE PERFORMED BY A QUALIFIED REPRESENTATIVE OF CABLE MANUFACTURER, THE
CABLES SHALL BE TESTED. NO SPLICING SHALL BE PERMITTED OF FIBER OPTIC CABLES, BETWEEN PANELS. ALL FIBERS SHALL BE
TERMINATED AT PATCH PANELS, INCLUDING SPARES.
13. REFER TO THE CABLE MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM BEND RADIUS FOR FIBER OPTIC CABLES. INSTALL NEW PULL
BOXES (PB) AS REQUIRED FOR CONDUITS. SIZE PULLBOXES AS REQUIRED PER FIBER OPTIC CABLE MANUFACTURERS RECOMMENDATIONS.
14. CONDUIT ENTERING CONTROL PANELS AND ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE FILLED WITH DUCT SEAL, INCLUDING
OPENINGS IN BOTTOM OF PANEL.
15. CABLES (INCLUDING FIBER, ETHERNET, CONTROL WIRE, ETC.) WHERE PASSING THROUGH A PULLBOX SHALL BE LABELED AND COMPLETELY
IDENTIFIED WITH IDENTIFICATION NUMBERS AND ORIGINATION/DESTINATION. THIS ALSO INCLUDES ALL CABLE BUNDLES ENTERING
CONTROL PANELS, PULLBOXES, ETC.
16. CONTROL WIRES SHALL BE TAGGED WITH THE PLC I/O ADDRESS IN THE FIELD AND AT THE PANEL.
17. FIBEROPTIC CABLE (FO, E-FO) SHALL BE 50/125 MICRON, ALL DIELECTRIC, CORNING ALTOS SERIES, WITH WATERBLOK GEL AND SUITABLE
FOR INSTALLATION IN AN UNDERGROUND, WET CONDUIT, PROVIDE STRANDS AS SHOWN. TERMINATE ALL STRANDS. FOR THE FIBEROPTIC
CABLE SHOWN FOR ANALOG AND DISCRETE I/O DEVICES, FIBER OPTIC CABLE SHALL BE (BELDEN M9B701 OR EQUAL) 2-STRAND BREAKOUT
STYLE LOOSE BUFFER OUTDOOR RATED (900 MICRON BUFFER DIAMETER). AT FIELD ENCLOSURES, CONNECT DIRECTLY TO FOC-DI/DO/AI/AO
MODULES. PATCH PANELS NOT REQUIRED AT FIELD DEVICES.
18. THE FIELD DEVICES SHOWN ON THE P&ID'S, ELECTRICAL BACKGROUNDS, AND DETAILS SHEETS MAKEUP THE FIELD DEVICE EQUIPMENT
REQUIREMENTS. NOT ALL FIELD DEVICES REQUIRED ARE SHOWN ON THE P&ID'S.
19. UPS SELECTED TO BE COMPATIBLE WITH SOLA MCR TRANSFORMERS. (TYP.)
20. CONDUIT ENTERING CONTROL PANELS AND ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE FILLED WITH DUCT SEAL, INCLUDING
OPENINGS IN BOTTOM OF PANELS, AND EQUIPMENT.
21. REFER TO I/O DRAWING LAYOUT FOR ADDITIONAL SIGNALS NOT SHOWN ON P&ID FLOW DIAGRAMS.
EXAMPLES OF I/O
GENERAL NOTES:
MICROLOGIX
1100
IA-8 AI/
AO
AI DI
8
1762-IA8
BLUMFIELD-REESE PROCESSOR PANEL
PROPOSED WORK SHOWN IN BOLD
AQUA PROCESSOR PANEL
PROPOSED WORK SHOWN IN BOLD
I/O RACK
5/40E BCM
I/O RACK
5/40E BCM
I/O RACK
AJB
1791
16AC
BLOCK 1
RACK 5
GROUP 0
1791
NDC
BLOCK 2
RACK 5
GROUP 2
150OHM TERMINATION RESISTER
I/O RACK
5/40E
1791
16AC
BLOCK 1
RACK 5
GROUP 0
1791
NDC
BLOCK 2
RACK 5
GROUP 2
RACK
GROUP
150OHM TERMINATION RESISTER
BELDEN 9463 CABLE
BELDEN 9463 CABLE
KOCHVILLE PROCESSOR PANEL
PROPOSED WORK SHOWN IN BOLD
1. PLC HARDWARE TO BE ROCKWELL AS SHOWN.
2. RADIO TO BE GEMDS AS SHOWN.
3. REFER TO WIRING DIAGRAMS ON SHEETS I-3 THRU I-6
FOR ADDITIONAL INFORMATION.
4. PROGRAMMING OF PLC'S, OPERATION INTERFACE
COMPUTERS (OWNERS EXISTING SCADA SYSTEM),
AND RADIOS BY TETRATECH.
NOTES:
MICROLOGIX
1100
AI/
AO
INET-11
900MHZ
KMPP NEMA 4 ENCLOSURE
CAT-5E PATCH CABLES
CAT-5E PATCH CABLES
TRANSTECTOR 10/100-BASE-T
ETHERNET SURGE SUPPRESSOR
GEMDS-REMOTE
FURNISH JUMPER WITH RIGHT
ANGLE CONNECTOR AT RADIO
POLYPHASOR DSXL SERIES
1/2" SUREFLEX JUMPER
FURNISH GROUND KIT
FOR GROUNDING RF CABLE
TIMES MICROWAVE LMR-400
CABLE-25 FEET IN TOTAL LENGTH
RFS CELLWAVE 10108-2 YAGI ANTENNA
ORIENT TO KOCHVILLE PUMP
STATION ACCESS POINT
KOCHVILLE, AND MICHIGAN AVE. PRESSURE
MONITORING STATION PROCESSOR PANEL
PROPOSED WORK
BLOCK I/O MODULES
PROGRAMMING OF PLC'S,
RADIOS, OPERATOR
INTERFACE COMPUTERS
BY TETRA TECH.
GENERATOR RUNNING
GENERATOR FAULT
BLOCK 1
RACK 5
GROUP 0
120V
AC
IN 00
IN 01
IN 02
IN 03
IN 04
IN 05
IN 06
IN 07
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN 16
IN 17
BELDEN 9463 CABLES
REMOTE I/O CABLES
FROM PLC
OUT 00
OUT 01
OUT 02
OUT 03
OUT 04
OUT 05
OUT 06
OUT 07
OUT 10
OUT 11
OUT 12
OUT 13
OUT 14
OUT 15
OUT 16
OUT 17
120V AC
H
N
G
BLUE
CLR
SHLD
CONNECT TO
EXISTING UPS CIRCUIT
WITHIN PANEL
SIGNALS FROM
GENERATOR
SIGNALS FROM AUTOMATIC
TRANSFER SWITCH
SIGNALS FROM
TVSS SURGE UNIT
H N
GENERATOR OVER SPEED
GENERATOR OVER CRANK
LOW OIL PRESSURE
LOW COOLANT TEMPERATURE
SPARE
SPARE
ATS IN NORMAL POSITION
ATS IN EMERGENCY POSITION
TVSS FAULT
SPARE
SPARE
SPARE
SPARE
SPARE
GENERATOR START/STOP
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
1
2
3
4
1
2
BLOCK 2
RACK 5
GROUP 2
I2600
I2601
I2602
I2603
O2600
O2601
1791-NDC
BLOCK I/O
4-20MA
SIGNALS
FROM
GENERATOR
BLOCK NO.2
POWER
DC+ DC-
CR-20
CONNECT IN
PARALLEL WITH
START CONTACT
FROM ATS
SEE NOTE 1
1. LOCATE THE BLOCK MODULES, TERMINAL BLOCKS(COLOR CODED AS
SPECIFIED), POWER SUPPLY, PANDUIT/WIRE COVERS, AND ASSOCIATED
DEVICES ON A SUBPLATE. SIZE SUBPLATE TO FIT ONTO EXISTING DOOR
INTERIOR.
2. WITHIN THE PANEL, FURNISH BRANCH CIRCUIT WIRING AS REQUIRED TO
CONNECT POWER, I/O CABLE, AS SHOWN. SECURE WIRING WIRING
BETWEEN PANEL AND NEW DOOR SUBPLATE.
3. CONNECT INPUTS AND OUTPUT AS SHOWN.
NOTES:
GENERATOR BATTERY VOLTAGE
GENERATOR OIL PRESSURE
GENERATOR CONSTANT
TEMPERATURE
SPARE
SPARE
SPARE
H N
H N
G
TO ANALOG BLOCK
GENERATOR RUNNING
GENERATOR FAULT
BLOCK 1
RACK 5
GROUP 0
120V
AC
IN 00
IN 01
IN 02
IN 03
IN 04
IN 05
IN 06
IN 07
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN 16
IN 17
BELDEN 9463 CABLES
REMOTE I/O CABLES
FROM PLC
OUT 00
OUT 01
OUT 02
OUT 03
OUT 04
OUT 05
OUT 06
OUT 07
OUT 10
OUT 11
OUT 12
OUT 13
OUT 14
OUT 15
OUT 16
OUT 17
120V AC
H
N
G
BLUE
CLR
SHLD
CONNECT TO
EXISTING UPS
CIRCUIT
WITHIN PANEL
SIGNALS FROM
GENERATOR
SIGNALS FROM AUTOMATIC
TRANSFER SWITCH
SIGNALS FROM
TVSS SIGNAL UNIT
H N
GENERATOR OVER SPEED
GENERATOR OVER CRANK
LOW OIL PRESSURE
LOW COOLANT TEMPERATURE
SPARE
SPARE
ATS IN NORMAL POSITION
ATS IN EMERGENCY POSITION
TVSS FAULT
SPARE
SPARE
SPARE
SPARE
SPARE
GENERATOR START/STOP
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
1
2
3
4
1
2
BLOCK 2
RACK 5
GROUP 2
I2600
I2601
I2602
I2603
O2600
O2601
1791-NDC
BLOCK I/O
4-20MA
SIGNALS
FROM
GENERATOR
BLOCK NO.2
POWER
DC+ DC-
CR-20
CONNECT IN
PARALLEL WITH
START CONTACT
FROM ATS
SEE NOTE 1
1. LOCATE THE BLOCK MODULES, TERMINAL BLOCKS, POWER SUPPLY,
PANDUIT/WIRE COVERS, AND ASSOCIATED DEVICES ON A SUBPLATE.
SIZE SUBPLATE TO FIT ONTO EXISTING DOOR INTERIOR.
2. WITHIN THE PANEL, FURNISH BRANCH CIRCUIT WIRING AS REQUIRED
TO CONNECT POWER, I/O CABLE, AS SHOWN. SECURE WIRING
WIRING BETWEEN PANEL AND NEW DOOR SUBPLATE.
3. CONNECT INPUTS AND OUTPUT AS SHOWN.
4. DEMOLISH EXISTING TELEMETRY EQUIPMENT ASSOCIATED WITH
KOCHVILLE MICHIGAN AVE. PRESSURE MONITORING STATION.
5. ALTERNATE # 2-A
6. RELOCATE TO EXISTING PLC INPUTS WHERE AVAILABLE.
NOTES:
GENERATOR BATTERY
VOLTAGE
GENERATOR OIL
PRESSURE
GENERATOR COOLANT
TEMPERATURE
SPARE
SPARE
SPARE
H N
H N
G
TO ANALOG BLOCK
GENERATOR BATTERY VOLTAGE
GENERATOR OIL PRESSURE
GENERATOR COOLANT TEMPERATURE
07
06
05
04
03
02
01
00
8 POINT DISCRETE
INPUT CARD
1762-IA8
GENERATOR RUNNING
GENERATOR FAULT
GENERATOR OVERLOAD
GENERATOR OVER CRANK
GENERATOR LOW OIL PRESSURE
GENERATOR LOW COOLANT
TEMPERATURE
SPARE
SPARE
1. INSTALL THE DIGITAL INPUT CARD AS SHOWN WITHIN THE EXISTING
BOOSTER STATION PROCESSOR PANEL. WIRE ALL I/O TO TERMINATE
STRIP INCLUDING SPARES.
2. WITHIN THE EXISTING PANEL, FURNISH TERMINAL BLOCKS(COLOR
CODED AS SPECIFIED) AND WIRING.
3. CONNECT INPUTS AS SHOWN.
NOTES:
EXISTING DRAWING FROM PREVIOUS
PROJECT NO. 200-12753-09001-W-1.
PROPOSED WORK SHOWN BOLD
AND/OR BUBBLED
NO.
LINE
L1 N
L1 N
EDCO SLA SERIES SURGE PROTECTION
LOCATE IN SEPARATE
NEMA 4X ENCLOSURE
BESIDE PANEL.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ORANGE COLORED
OUTLET. LOCATE ON
SIDE OF PANEL.
ON-LINE UPS
350KVA
LIEBERT
1.0 AMP
24VDC P/S
+ -
1
2
2
1SPARE
DISCHARGE PRESSURE
0-150 PSI
ANALOG INPUT/OUTPUT
CARD (2AI/2AO)
MICROLOGIX 11OO
1763-L16AWA
C
0
1
2
3
C
4
5
6
7
8
9
IA
I1
I2
C
0
1
2
3
4
5
FURNISH CONTROLLER WITH
MEMORY MODULE. (1763-MM1)
TO UPS
3PT. LATCH
SIZE: 30"H X 30"W X 20"D MINIMUM
PAINT INSIDE: GLOSS WHITE
PAINT OUTSIDE: SHERMAN WILLIAMS PILLAR WHITE (SW-4023)
PUSHBUTTON
FOR
STATION
MAINTENANCE
MICROLOGIX
1100
2 X
4 D
UC
T
2 X
4 D
UC
T
ETHERNET
SURGE
PROTECTION
LOOP POWER - 2 WIRE
TRANSMITTER POWER
DINRAIL MOUNTED BREAKERS
THIS AREA.
FUSIBLE TERMINAL BLOCKS.
120VAC FROM EXISTING LIGHTING PANEL BOARD
1762-IF2OF2
24VDC
+ -
H1 N
SPARE
SPARE
NEW PRESSURE
TRANSMITTER
POWER ON
COOLING FAN
1. LOCATE THE NEW PRESSURE MONITORING PANEL ON THE BACK SIDE OF THE
BUILDING.
2. MOUNT PANEL ON STAINLESS STEEL STRUT SUPPORT RACK.
3. INSTALL A 20 FOOT , 2 INCH DIAMETER ALUMINUM MAST PIPE, YAGI ANTENNA, AND
25 FEET OF LMR CABLE.
4. SUPPORT PIPE TO SIDE OF PANEL AND BRICK BUILDING WITH STAINLESS STEEL
STRUT AND SUPPORT HARDWARE.
5. WEATHERPROOF THE CABLE ENDS AT THE TOP AND BOTTOM.
6. INSTALL A 10 FOOT COPPER GROUND ROD, AND BOND TO PANEL AND MAST PIPE
WITH GREEN INSULATED NO.6 AWG CONDUCTOR.
7. CORE HOLE THRU WALL FOR TWO ONE INCH CONDUITS. ONE CONDUIT FOR
120VAC POWER, AND ONE CONDUIT FOR THE SHIELDED CABLE.
8. WITHIN THE BUILDING, CONNECT TO SPARE 120VAC PANELBOARD FOR POWERING
PANEL. ASSUME 20 FEET OF IJ INCH PLASTIC CONDUIT, WITH 3#12 WIRES. LABEL
PANELBOARD DIRECTORY FOR NEW PANEL.
9. WITHIN THE BUILDING, FURNISH AND INSTALL ONE YOKOGAWA EJA SERIES
PRESSURE TRANSMITTER RANGED 0-150PSI. TRANSMITTER WETTED PARTS AND
TO BE HASTELLOY C AND MANIFOLD TO BE STAINLESS STEEL. FURNISH
MOUNTING BRACKET AS REQUIRED FOR TRANSMITTER. REMOVE EXISTING
TRANSMITTER, AND REWORK EXISTING SENSING LINE. ASSUME FOR
INSTALLATION OF 5 FEET OF İ INCH COPPER TUBING. PROVIDE BRASS BALL
SHUTOFF VALVE AT TRANSMITTER.
10.INSTALL 15 FEET OF IJ INCH PLASTIC CONDUIT WITH 2/C#18SH CABLE FROM THE
TRANSMITTER TO THE NEW PROCESSOR PANEL.
11.SEAL HOLES IN WALL WITH NON-SHRINK GROUT.
12.CONDUIT AT THIS LOCATION TO BE PVC SCHEDULE 40.