Transcript of Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl,...
![Page 1: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/1.jpg)
Physiological Physiological MetronomeMetronome
Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen
Clients: Dr. Bill Fahl, Dept. of OncologyVanessa Young, Carnegie Mellon music student
Advisor: Dr. Paul Thompson, Dept. of Biomedical Engineering
![Page 2: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/2.jpg)
BackgroundBackground
Metronomes provide time or rhythm to musicians
Currently metronome features include:
LCD display Mechanical and electronic
timing mechanisms Beats which are audible and/or
tactile Analog and digital user outputs
![Page 3: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/3.jpg)
Design MotivationDesign MotivationThe motivation for our design comes
from Vanessa Young, a music student at Carnegie Mellon
Conventional visual and audio metronomes tend to be distracting
Currently there is no adequate device on the market which functions as a metronome and uses a precise tactile pulse as the stimulus
Such a metronome would allow the user to “internalize” the beat of the music
![Page 4: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/4.jpg)
Client Requirements and Design Client Requirements and Design ConstraintsConstraints
The client requires the following for the metronome device:
Maintain the tempo in an inaudible and accurate manner
Cover a tempo range of 40 to 260 bpm (beats per minute)
Should not attach to parts of the body involved in playing the instrument (i.e. forearm or wrist)
![Page 5: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/5.jpg)
““Constant/Permanent” Constant/Permanent” Features of the DesignFeatures of the Design
The circuit (with slight modifications)
Original: http://electroschematics.com/216/electronic-metronome-circuit-schematic/
![Page 6: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/6.jpg)
““Constant/Permanent” Constant/Permanent” Features of the DesignFeatures of the Design
The case
http://www.hammondmfg.com/pdf/1593P.pdf
![Page 7: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/7.jpg)
Design Aspect: Design Aspect: What is the form of What is the form of tactile stimulus?tactile stimulus?
Options:
VibrationCompressionShockTap
![Page 8: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/8.jpg)
Option: Option: VibrationVibrationOne option for the tactile stimulus
would be a vibration, similar to that felt on a phone
Vibration would be produced by an electric motor
Pro◦ The user would likely have no trouble
feeling the vibrationCon
◦ Ability to differentiate between successive vibrations may be difficult at high tempos
![Page 9: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/9.jpg)
Option:Option: Compression CompressionAnother possible option for the stimulus would
be a band around the arm, leg, or lower back which “squeezed” the user to the selected beat
The compression would be produced by a solenoid which shortened the band for each beat
Pro◦ Comfort
Con◦ Uniform compression may be difficult to achieve◦ Complicated construction
![Page 10: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/10.jpg)
Option: Option: ShockShock
A small shock could be provided to the user to represent the beat or time of the music
There are several problems with this option including user safety, variability in shock based on user skin conditions (e.g. sweating), and user comfort
![Page 11: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/11.jpg)
Option: Option: TapTap
The tactile stimulus could be a mechanical tap
Generated from a solenoid directly in contact with the body
Pro◦ Good resolution at high tempos
Con◦ Size of solenoid
![Page 12: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/12.jpg)
Design Matrix: Design Matrix: What is the form of What is the form of tactile stimulus?tactile stimulus?
Tactile Stimulus
User Comfort (20)
Resolution of Signal (40)
Lifespan (15)Size of Tactile
Generator (25) Total (100)
Tap 15 37 11 15 78
Shock 7 27 14 20 68
Vibration 14 21 12 17 64
Compression 9 24 7 13 53
![Page 13: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/13.jpg)
Design Aspect: Design Aspect: Where to locate the Where to locate the tactile stimulus?tactile stimulus?
Options:
Upper ArmLower BackEar
![Page 14: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/14.jpg)
Option:Option: Upper Arm Upper ArmI-Pod elastic
docking band
Pros◦Ease of attachment◦User comfort
Cons◦Interference with
musical performance
◦Tactile discrimination
![Page 15: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/15.jpg)
Option:Option: Lower Back Lower Back
“Anchoring-Cap” ideaAdhesive padding ringCylindrical solenoid firmly
positioned in durable plastic cap
Pros◦ Immobilized◦ Visually concealed
Cons◦ Need to replace adhesive◦ Possibility of discomfort due
to sitting◦ Tactile discrimination a
question
“Anchoring-Cap” as a means to secure the tactile transducer to the lower back.
![Page 16: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/16.jpg)
Option:Option: Ear Attachment Ear Attachment
Ear clip, ear-formed adapter, or behind the ear designs
Pros◦ Most proximal to
audible processing center to internalize tempo
◦ Most sensory discrimination relative to arm back
Cons:◦ User specificity ◦ Stability
Tactile transducer embedded in a form-fitting material.
Tactile transducer attached behind ear lobe.
![Page 17: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/17.jpg)
Design Matrix: Design Matrix: Where to locate the Where to locate the tactile stimulus?tactile stimulus?
Location of Stimulus
User Comfort
(30)
Resolution of Signal
(40)
Ease of Attachment
(25)
Visual Appeal (5) Total (100)
Lower Back 25 30 18 4 77
Ear 22 36 17 4 79
Upper Arm 20 25 21 3 69
![Page 18: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/18.jpg)
Design Aspect: Design Aspect: How to attach the How to attach the tactile transducer?tactile transducer?
Options:
AdhesiveElasticForm-fitting
![Page 19: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/19.jpg)
Option: Option: AdhesiveAdhesive•Pros•Conforms to body shape•Secure attachment
•Cons•Adhesive will wear out•Uncomfortable to remove
![Page 20: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/20.jpg)
Option: Option: ElasticElastic•Pros•Secure attachment•Variety of options available
•Cons•May not work for all locations
![Page 21: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/21.jpg)
Option: Option: Form-FittingForm-Fitting•Pros•Conforms to body shape
•Cons•Not as secure•Possibly difficult to construct
![Page 22: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/22.jpg)
Design Matrix: Design Matrix: How to attach the How to attach the tactile transducer?tactile transducer?
Mode of Attachment Stability (30)
User Comfort (35)
Ease of Construction
(20)
Visual Appeal (15) Total (100)
Adhesive 24 23 16 12 75
Elastic 26 25 18 10 79
Form-Fitting 22 31 14 13 80
![Page 23: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/23.jpg)
Design Aspect: Design Aspect: How to design the user How to design the user interface?interface?
Options:
Knob/LCD displayButtons/LCD displayKnob/Tick Marks
![Page 24: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/24.jpg)
Option:Option: Knob/LCD Display Knob/LCD Display
commons.wikimedia.org/wiki/File:Potentiometer.jpg
detail.en.china.cn/provide/detail,1078195290.html
![Page 25: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/25.jpg)
Option:Option: Buttons/LCD Buttons/LCD DisplayDisplay
http://www.bigfoto.com/sites/galery/closeup1/digital-camera-buttons.jpg
detail.en.china.cn/provide/detail,1078195290.html
![Page 26: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/26.jpg)
Option:Option: Knob/ Tick Marks Knob/ Tick MarksPros Easiest to constructMost cost-effective optionCons Least accurate/precise
optioncommons.wikimedia.org/wiki/File:Potentiometer.jpg
http://www.telerik.com/help/wpf/images/RadialScaleTickMarks-Desc.png
![Page 27: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/27.jpg)
Design Matrix: Design Matrix: How to design the user How to design the user interface?interface?
User Input/ Output
Ease of Use (30)
Ease of Construction
(25)
Cost (15)Accuracy/ Precision
(30)
Total (100)
Knob/Tick Marks
24 24 13 22 83
Knob/LCD display
26 18 10 27 81
Buttons/LCD display
28 13 9 28 78
![Page 28: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/28.jpg)
Final Design SummaryFinal Design SummaryCase contains protruding
knob/potentiometerTick marks indicate tempo (aligned with
knob)Case outputs to tactile stimulus via an
output jackTactile stimulus attaches to user in ear-
specific manner, delivers tempo
![Page 29: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/29.jpg)
Ethical ConsiderationsEthical Considerations
Device is intended for human users Safety is a must
Long duration of use Tactile device must be safe for continuous
use
Tactile stimulus concerns
![Page 30: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/30.jpg)
Future WorkFuture WorkConstructionTesting:
◦Compare musicians using tactile metronome to visual and audio metronomes
◦Determine if resolution changes with excessive background sound
More user-friendly interfaceProgrammable temposBluetooth synchronization among
multiple users
![Page 31: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/31.jpg)
Acknowledgments Acknowledgments
We would like to thank:◦Dr. Bill Fahl, client◦Vanessa Young, client◦Dr. Paul Thompson, advisor◦Amit Nimunkar, electronics
assistance
![Page 32: Physiological Metronome Adam Pala, Ben Fleming, Cole Drifka, Jeff Theisen Clients: Dr. Bill Fahl, Dept. of Oncology Vanessa Young, Carnegie Mellon music.](https://reader035.fdocuments.us/reader035/viewer/2022062713/56649cee5503460f949bc744/html5/thumbnails/32.jpg)
Questions:Questions: