Physics cases for tracking

11
Physics cases for tracking Calculations made by Lisbon and Sevilla. Similations by D. Rodriguez (Huelva)

description

Physics cases for tracking. Calculations made by Lisbon and Sevilla. Similations by D. Rodriguez (Huelva). 19 C at the Low Energy Branch (LEB). Settings 1: 48 Ca energy: 400 MeV/u. Graphite target:  = 3 g/cm 2 Degrader 1: Al with  = 20.9 g/cm 2 . - PowerPoint PPT Presentation

Transcript of Physics cases for tracking

  • Physics cases for trackingCalculations made by Lisbon and Sevilla. Similations by D. Rodriguez (Huelva)

  • 19C at the Low Energy Branch (LEB)Settings 1:48Ca energy: 400 MeV/u.Graphite target: = 3 g/cm2Degrader 1: Al with = 20.9 g/cm2.Degrader 2: Al with = 10.5 g/cm2.Without contaminants.Settings 2:48Ca energy: 400 MeV/u.Graphite target: = 3 g/cm2Degrader 1: Al with = 20.9 g/cm2.Same yield of 20N and 19C.Calculations courtesy of David Boutin

  • The Low Energy Branch (LEB) 19C estimatesSettings 1

  • Beam parameters and tracking system 19C11Be = 38 MeV/u = 8.4 MeV/uEFWHM = 3 MeV/uTrack1DSSSD (20 m)SeD?Track2DSSSD (20 m)SeD?2 m30 cm208Pb (for 19C)1 mg/cm2Diameter: 10 cm x (19C)= 344 mm mrady (19C)= 376 mm mrad x (11Be)= 344 mm mrad y (11Be)= 376 mm mradC8H8 (for 11Be)1 mg/cm2Diameter: 10 cm

  • E1 E2 E/ E3 E Detection set-ups:- E1 : DSSSD Si-40m.- E2 : DSSD 200 m. E/ E3 : Single PAD 1.5 mm. E : CsI 6 cm. Pulse shape analysis. Time of flight.Detector setupTarget30401) d = 17 cm Angular resolution: 2. Pixel: 3x3 mm2. 19C @ 160 MeV19C18C2) d = 34.4 cm Angular resolution: 2 Pixel: 6x6 mm23) d = 68.8 cm. Angular resolution: 2 Pixel: 1.2x1.2 cm2dBeam010Be10

  • 19C Elastic scattering + break-up (no tracking)50 100 150 200 250 50 100 150 200 250 18C19C18C19C18CEtotal /MeVEtotal /MeVE /MeVE /MeVE = E1+ E2 Detector resolution 2% (Si)50 100 150 200 250 Etotal /MeV19C18CE /MeV1)2)3)

  • 50 100 150 200 250 19C Elastic scattering + break-up (tracking)19C18CEtotal /MeVE /MeV1)50 100 150 200 250 Etotal /MeV2)3) 50 100 150 200 250 Etotal /MeVE /MeVt = 1 ns 18C19C19C18C3)3)High time resolutionneeded SeD

  • 11Be Elastic scattering + break-up 10Be 50 150 250 350 450 E = E1+ E2 + E3 Detector resolution 2% (Si)Detector resolution 10% (CsI)3) No trackingEtotal /MeVE /MeV11Be10Be3) Tracking

    t = 60 ps 11Be10Be 50 150 250 350 450 Etotal /MeVE /MeV 50 150 250 350 450 Etotal /MeV3) Tracking+ pixel

  • Low energy vs high energy

  • Tracking requirements for low energy beams (5-20 MeV/u)Angular resolution: 0.5-1Timing: 0.7-0.3 ns

  • Transverse momentum resolutionpT = m v q