Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

download Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

of 13

Transcript of Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    1/13

    Confidential Philips Lighting, Oct 21, 2011

    Philips Lighting

    Feb 1st , 2012

    Plug & play retrofit lamps

    to save energy

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    2/13

    Confidential Philips Lighting, Oct 21, 2011

    Plug & play retrofit lamps to save energy19% of world electricity is used for lighting

    40% of lighting is made with fluorescent lamps

    New lighting technologies allow to save much

    Up to 50% from new fluorescent lamps

    Up to 90% from new LED lamps

    And more with Lighting Controls

    All from

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    3/13

    Confidential Philips Lighting, Oct 21, 2011

    Same lighting level as standard TLD Super 80 color technology Easy & safe to install RoHS compliance Reliable lifetime of20,000hrs

    Benefits

    A plug & play retrofit batten that saves

    energy!

    What is it?

    One to one replacement for existing

    T8 Standard lamps on

    electromagnetic gear Recommended for use in industry,

    commercial areas, car park, subway.

    Key applications

    T5 RetroSave 28WA plug & play retrofit batten that saves up to 35% of energy

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    4/13

    Confidential Philips Lighting, Oct 21, 2011

    T5 RetroSave 28WA plug & play retrofit batten that saves 35% of energy

    Saves up to 50% of energy with

    Reflector types (allows skip lamp) uniform light distribution @ 120deg

    Extra Benefit

    Extra safety with SPL025 starter Insulator for full security at installation,

    end of life, replacement. Avoid misuse

    Extra Benefit

    Fits presence sensors with20000switches cycles for 20000 hours

    lifetime withwarm start which protects

    electrodes

    Extra Benefit

    Warm Start

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    5/13

    Confidential Philips Lighting, Oct 21, 20115

    T5 RetroSave 28W Warm Start spec comparisonTLD 36W Stdon EM gears

    T5 RetroSave 28WWarm Start

    T5 RetroSave ReflectorWarm Start

    Lamp lumen rated 2500lm 2600lm 2600lm

    System Power 44W 28W 28W

    Lamp lifetime:

    50% failure pt 13,000hrs 20,000hrs 20,000hrs

    10% failure pt 8000hrs 10,000hrs 10,000hrs

    Lumen maintenance:%

    @ 2000hrs 90 94 94

    @ 5000hrs 83 91 91

    @ 10000hrs 89 89

    Hg 8mg 3mg 3mg

    Ignition time 80

    Illuminance (lux) @ 1m 228 265 628

    Illuminance (lux) @ 2m 69 77 182

    Switching cycle 8000 20000 20000

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    6/13

    Confidential Philips Lighting, Oct 21, 20116

    to reduce our demand forenergy.

    For others, its a way to a more sustainable future

    For some people, this means a reliable and better lifestyle

    For some people, this means money in the pocket

    Using Energy Efficient Lighting Solution

    - is a simple and easy way

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    7/13Confidential Philips Lighting, Oct 21, 20117

    example of savings scenario with T5 RetroSave

    The 35% lower energy consumption can brings the saving of :

    Description UnitTLD Standard

    36WT5 RetroSave

    28W

    Product power W 36 27

    Power loss on

    electromagnetic ballast W 8 1System power W 44 28Operating

    hours/year(12h/day). h 4380 4380Total energy consumption/Year Kwh 193 123

    Energy saving per

    yearKWh 70

    market study tells that

    120M Fluorescent tubesare installed in South Africa

    If we replace

    only 1%we save84 TWh

    (84 Million MWh)

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    8/13Confidential Philips Lighting, Oct 21, 2011

    8

    Other energy saving opportunities

    Power Saver Set30% energy saving with a simple switch!

    MasterLED LampsLeds to retrofit all halogen and incandescent lamps

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    9/13

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    10/13Confidential Philips Lighting, Oct 21, 2011

    T-LEDLeds to replace fluorescent tubes

    Key benefits:

    A simple lamp-for-lamp replacement which: Decrease energy cost as consume less &100% light is useful Decrease cost for maintenance as longer life, very low failure rate Get a green image to leverage on market thanks to LED technology Fits perfect for hard conditions as cold, vibrations Easy fit with full EM type as adapts to all EM circuits to get PF0.9

    3 sizes, 3 types

    on EM & Mains

    40000hrs

    65%energy savings

    possible

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    11/13Confidential Philips Lighting, Oct 21, 2011

    MasterLED LampsLeds to retrofit all halogen and incandescent lamps

    Key benefits:

    A simple lamp-for-lamp replacement which: Decrease energy cost as consume less Decrease cost for maintenance as longer life, very low failure rate One MasterLED lamp to replace all energy spoiling old lamps Get a green image to leverage on market thanks to LED technology

    90%energy savings

    possible

  • 7/29/2019 Philips_T5_Retrosave_and_otherRetrofit_Lamps_to_save_Energy_Eskom_Feb.pdf

    12/13Confidential Philips Lighting, Oct 21, 2011

    12

    A world of Energy Saving

    opportunitieswith retrofit lamps