PFCR 140 / 120 / 80 / 60 Power Factor Control Relays Features

2
Power Factor Controller Microprocessor based intelligent auto switching control Automatic C/K and rated step adjustment Automatic CT polarity correction Display of power factor, current & total harmonic distortion of current Programmable sensitivity Last step can be used as alarm / fan output Under / over voltage alarm, under / over compensate alarm & high harmonic distortion alarm Supply voltage Operating Limits Consumption Frequency : 346~415 V AC : -15% to +10% : 10 VA max : 50 Hz Rated current, In Operating Limits Rated Frequency : 5 A : 0.05A - 6.5A : 50 Hz Power Factor setting C / K setting Switching sensitivity Reconnection time for Same step THD Threshold Switching Program Rated step coefficient : 0.8 inductive -0.8 capacitive : 0.03 - 1.20 / Automatic : 5 - 600 s / step : 5 - 240 s : 0.20 - 3.00 (20% - 300%) / OFF : Automatic / Automatic Rotate / 4-quadrant / Manual : 0 / 1 / 2 / 3 / 4 / 6 / 8 / 12 / 16 (Automtaic if C/K set of Auto) Mounting Dimension (hxwxd) Approximate weight : Panel mounting : 144mm x 144mm x 91mm : 1 kg Numbers of outputs Contact arrangement Rated capacity Max current for the common terminals 6 / 8 / 12 / 14 : NO contacts type : 5A, 250 V AC (Cos =1) : 12 A continuous Features Technical Data Ratings Auxiliary Power Supply Current Input Relay Output Control Range Mechanical PFCR 6 / 8 / 12 / 14 Steps HPL - PFCR 6 / 8 / 12 / 14 Steps ACCREDITED ISO-9001:2008 ISO-14001:2004

Transcript of PFCR 140 / 120 / 80 / 60 Power Factor Control Relays Features

Page 1: PFCR 140 / 120 / 80 / 60 Power Factor Control Relays Features

Power Factor C

ontroller

Microprocessor based intelligent auto switching control

Automatic C/K and rated step adjustment

Automatic CT polarity correction

Display of power factor, current & total harmonic distortion of current

Programmable sensitivity

Last step can be used as alarm / fan output

Under / over voltage alarm, under / over compensate alarm & high harmonic distortion alarm

Supply voltage

Operating Limits

Consumption

Frequency

: 346~415 V AC

: -15% to +10%

: 10 VA max

: 50 Hz

Rated current, In

Operating Limits

Rated Frequency

: 5 A

: 0.05A - 6.5A

: 50 Hz

Power Factor setting

C / K setting

Switching sensitivity

Reconnection time forSame step

THD Threshold

Switching Program

Rated step coefficient

: 0.8 inductive -0.8 capacitive

: 0.03 - 1.20 / Automatic

: 5 - 600 s / step

: 5 - 240 s

: 0.20 - 3.00 (20% - 300%) / OFF

: Automatic / Automatic Rotate / 4-quadrant / Manual

: 0 / 1 / 2 / 3 / 4 / 6 / 8 / 12 / 16

(Automtaic if C/K set of Auto)

Mounting

Dimension (hxwxd)

Approximate weight

: Panel mounting

: 144mm x 144mm x 91mm

: 1 kg

Numbers of outputs

Contact arrangement

Rated capacity

Max current for the

common terminals

6 / 8 / 12 / 14

: NO contacts type

: 5A, 250 V AC (Cos =1)

: 12 A continuous

Features

Technical Data

Ratings Auxiliary Power Supply

Current Input

Relay Output

Control Range

Mechanical

PFCR 6 / 8 / 12 / 14 Steps

HPL - PFC

R 6 / 8

/ 12

/ 14

Steps

ACCREDITED

ISO-9001:2008ISO-14001:2004

PFCR 140 / 120 / 80 / 60Power Factor Control Relays

Page 2: PFCR 140 / 120 / 80 / 60 Power Factor Control Relays Features

HPL - PFC

R 6 / 8

/ 12

/ 14

Steps

Pow

er F

acto

r Con

trol

ler

HPL - PFCR 6 / 8 / 12 / 14 Steps

PFC06041550

PFC08041550

PFC12041550

PFC14041550

6 Steps, 415 V AC, 50 Hz power supply

8 Steps, 415 V AC, 50 Hz power supply

12 Steps, 415 V AC, 50 Hz power supply

14 Steps, 415 V AC, 50 Hz power supply

Typical Application Diagram Case Dimensions

Ordering Information

Item Code Panel Cutout

Side

Front

Description

91 mm

77 mm

136 mm

136

mm

PF

CR

140

HP

L/P

FC

R/0

91

3

VOLTAGE346~415V

0141-4108426 0891-6461730

022-61830810

PFCR 140 / 120 / 80 / 60Power Factor Control Relays