Residential and Light Commercial
4.0 TON
8-Zone Multi-SplitProduct Flyer 2014/2
EXPERTISE AND INNOVATION
ENERGY EFFICIENCY
INDIVIDUAL COMFORT AND CONTROL
BUILT-IN RELIABILITY
The 8-Zone Multi-Split System is the ultimate, flexible solution for
individual zone comfort. Connecting up to 8 indoor units to a
single outdoor unit reduces installation space and
costs while maximizing comfort and energy savings.
With a choice of three indoor unit types in a wide
range of capacities, the 8-Zone Multi-Split allows
mixed and matched combinations for
absolute comfort in almost any residential application.
Integrated with an inverter “variable speed”
compressor, Daikin 8-Zone Multi-Split systems deliver the
capacity required to maintain desired room conditions,
typically reducing energy consumption by 30% compared to
traditional fixed speed systems. This technology minimizes
temperature fluctuations and provides continuous cooling
and heating comfort with maximum energy savings.
All major components are engineered and
manufactured by Daikin, ensuring maximum
performance, reliability and efficiency. The
standard warranty provides a solid level of
protection on the 8-Zone Multi-Split system.
Systems installed by an authorized Daikin
Dealer who has completed Daikin’s advanced
training can take advantage of Warranty Plus
– the best warranty in the industry.
Find a Daikin Dealer near you at
www.daikinac.com.
The standard wireless controller provides individual temperature control
at the click of the button. Most Indoor units are also compatible with the
new Daikin ENVi intelligent thermostat, offering a more advanced
solution, designed with energy savings performance in mind. With the
freedom to access, program and control the system from a smart phone,
tablet, or computer, users can have peace of mind - anytime, anywhere.Note: The Daikin ENVi thermostat
is not compatible with the FFQ
Indoor Units
DESIGN FLEXIBILITY
CTXS_H, CTXS_LV, FTXS_LV
Wall Mounted Unit
Blends with any décor with it’s sleek and sophisticated design
Enhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odors
Increased energy savings with the intelligent eye function which reduces operation in unoccupied spaces
FDXS_LV, CDXS_LV
Concealed Slim Duct
Maximized floor and wall space with it’s compact and concealed design
Undisturbed comfort with low operating sound levels
Cleaner air with the removal or airborne dust particles by the standard mold proof air filter
FFQ_LV
2’ X 2’ Ceiling Cassette
Enhanced comfort with uniform airflow and temperature distribution
Draught free protection with horizontal air discharge
Simple installation with an easy-to-fit decoration panel that blends with any interior design
Easy maintenance with an easy-to-clean grille and washable long life filter
BPMKS
Branch Provider Unit
Varies the refrigerant volume to meet the cooling or heating requirements of each room connected to the system.
Facilitates zone on/off and capacity control to operate rooms individually via zone temperature controls
Simple installation with flare nut connections
REFNET joint
Reduces the amount of work involved in installation and increases the reliability of the system.
The 8-Zone Multi-Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations.
Indoor Unit AvailabilityCapacity
Indoor Type 7 MBH 9 MBH 12 MBH 15 MBH 18 MBH 24 MBH
Wall Mount
Slim Duct
2' x 2' Cassette
LEADING TECHNICAL PERFORMANCE
Outdoor Units – RMXS48LVJU
Model Name RMXS48LVJU
Nominal Capacity (Cooling / Heating) Btu/h 48,000 / 54,000
SEER / HSPFNon Ducted 18.8 / 11.3
Mixed 16.5/10.5
Ducted 14.1/9.6
EER / COPNon Ducted 10.3/3.0
Mixed 9.8/2.9
Ducted 9.3/2.7
Power Supply 208/230V - 1Ø - 60Hz
Minimum Circuit Amps A 27.0
Maximum Overcurrent Protection A 30.0
Sound Pressure - (Cooling/Heating) dB(A) 56/58
Connection Ratio (Max Capacity for BPMKS Boxes) 50 - 130%
Number of Connectable Indoor Units 2 to 8
Number of Connectable BP Units 1 to 3
Total System Piping Length ft. (m) 440 (135)
Max. Piping Length(OU to BP Box) ft. (m) 180 (55)
Max. Piping Length(IU to BP Box) ft. (m) 49 (15)
Total Piping Length (OU to BP Box) ft. (m) 180 (55)
Total Piping Length (BP to IU) ft. (m) 262 (80)
Max. Piping Height (OU to IU) ft. (m) 98 (30)
Max. Piping Height (IU to BP Box) ft. (m) 98 (30)
Max. Piping Height (BP to BP Box) ft. (m) 49 (15)
Piping Connection Kit KHRP26A22T
Operating Range – (Cooling/Heating) °F DB 23 – 115/5 - 75
Dimensions (H x W x D) in. 52-15/16 x 35-7/16 x 12-5/8
Net Weight lbs. 283.0
BP Units
Model Name BPMKS048A2U BPMKS049A3U
Power Supply Single phase 60Hz 208/230V
Power Consumption W 10 10
Running Current A 0.05 0.05
Sound Pressure - (Cooling/Heating) dB(A) 32/32 32/32
Number of Connectable Indoor Units 1 to 2 1 to 3
Min. Connection Combination 7,000 7,000
Max. Connection Combination 48,000 62,000
Piping
Connections
(O.D.)
Liquid
Outdoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3
Indoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3
Connection Type Flare Flare
Gas
Outdoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3
Indoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3
Connection Type Flare Flare
Dimensions (H x W x D) in. 7-1/16 x 11-9/16 x 13-3/4
Net Weight lbs. 18.0 20.0
Nominal Conditions:
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
Note:
Specifications are subject to change without notice.
Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted Units
Model Name CTXS07LVJU CTXS09HVJU CTXS12HVJU FTXS15LVJU FTXS18LVJU FTXS24LVJU
Airflow-Wet (H/M/L/SL) CFM 332/261/194/145 388/335/283/- 388/335/283/- 568/477/385/360 583/484/385/360 643/494/350/328
Airflow-Dry (H/M/L/SL) CFM 350/290/233/219 400/357/314/- 400/357/314/- 593/505/417/371 625/526/431/399 699/572/445/403
Sound Pressure - Cooling (H/M/L/SL) dB(A) 38/32/25/22 44/40/35/- 45/41/36/- 45/40/35/32 46/41/36/33 51/44/37/34
Sound Pressure - Heating (H/M/L/SL) dB(A) 38/33/28/25 44/39/34/- 45/40/35/- 43/38/33/30 45/40/35/32 48/42/37/34
Piping Connections
Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4
Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 5/8Condensate Drain Connection (O.D.) in. Ø 5/8 Ø 11/16 Ø 11/16 Ø 5/8 Ø 5/8 Ø 5/8
Dimensions (H x W x D) in. 11-5/8 x 31-1/2 x 8-7/16 11-7/16 x 31-5/16 x 9-3/8 13-3/8 x 41-5/8 x 9-3/4
Net Weight lbs. 20.0 20.0 20.0 31.0 31.0 31.0
Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct Units
Model Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU
External Static Pressure "W.G. 0.12 0.12 0.16 0.16 0.16
Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297
Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297
Sound Pressure - Cooling (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31
Sound Pressure - Heating (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31
Piping Connections
Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4
Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 1/2
Condensate Drain in. Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32
Dimensions (H x W x D) in. 7-7/8 x 27-9/16 x 24-7/16 7-7/8x35-7/16x24-7/16
Net Weight lbs. 47.0 47.0 60.0 60.0 60.0
Indoor Units - FFQ_LVJU 2’x2’Duct Units
Model Name FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU
Airflow Rate (H/L) CFM 318/230 353/230 424/283 530/353
Sound Pressure - Cooling (H/L) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31
Sound Pressure - Heating (H/L dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31
Piping Connections
Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4
Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2
Condensate Drain (O.D.) in. Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Ø 1-1/32
Dimensions – Unit (H x W x D) in. 11-1/4 x 22-5/8 x 22-5/8
Dimensions – Deco Panel (H x W x D) in. 2-1/4 x 27-5/8 x 27-5/8
Net Weight lbs. 38.5 38.5 38.5 38.5
0.6-Ton 0.75-Ton 1.0-Ton 1.25-Ton 1.5-Ton 2.0-Ton
Up to 2 Zones Up to 3 Zones
Up to 8 indoor units can be
connected to a single outdoor unit
A High Efficiency solution with optimum flexibility to
provide zoning for with the connection of up to 8 indoor
units utilizing long pipe lengths, ease of installation with
standardized line-sets, simplified electrical requirements
and staged installations
TIME-SAVING INSTALLATION AND EASE
Longer Refrigerant Piping
Simplified Electrical Wiring
The outdoor unit and BP units operate from separate
208/230V single-phase power supplies. Indoor units are
powered from the BP unit and wired as Daikin’s current
4 wire single split systems reducing the wiring size and
easing installation
More than 60% in physical space savings
More than 80% in total (including clearances)
space savings
Space Saving Design
Traditional Outdoor Unit
Daikin RMXS
35-7/16”
12
-5/8
”
35-1/8”
38
-11
/16”
Installation Space
Piping Requirements Allowable Length Details
Maximum
allowable
length
Between outdoor and BP units Total piping length Piping length between outdoor and BP units ≤ 180 ft (55 m) - [Example] a+b+c+d+e ≤ 180 ft
Between BP and indoor units Total piping length Piping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l ≤ 262ft
Between BP and indoor unit 1 room length Piping length between BP and indoor unit ≤ 49 ft (15 m) - [Example] f, g, h, i, j, k, l ≤ 49 ft
Allowable
height
Between outdoor and indoor
units
Difference in
height
Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)
Between outdoor and BP units Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)
Between BP and BP units Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)
Between indoor and indoor units Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)
Minimum allowable length Piping length Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft
Allowable length after the REFNET branch Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m)
[Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft
Additional refrigerant calculation
Longer refrigerant piping capabilities
offers much more flexibility in the
choice of installation positions for the
indoor units, and greatly simplifies
system layout.
PF8ZMUSE14-02R
System Operation Range
Cooling Operation 23 °FDB – 115 °FDB
Ambient Temperature
57 °FWB – 82 °FDB
Indoor Room Temperature
Heating Operation 5 °FDB – 60 °FWB
Ambient Temperature
50 °FDB – 82 °FDB
Indoor Room Temperature
Note: No low ambient option exists with this product line.
• Always use a licensed installer or contractor to install this product. Do not try to
install the product yourself. Improper installation can result in water or refrigerant
leakage, electrical shock, fire or explosion.
• Use only those parts and accessories supplied or specified by Daikin. Ask a licensed
contractor to install those parts and accessories. Use of unauthorized parts and
accessories or improper installation of parts and accessories can result in water or
refrigerant leakage, electrical shock, fire or explosion.
• Read the User’s Manual carefully before using this product. The User’s Manual
provides important safety instructions and warnings. Be sure to follow these
instructions and warnings.
For any inquiries, contact your local Daikin sales office.
WARNINGS:
Use of the AHRI Certified™ mark indicates a manufacturer's
participation in the certification program. For verification of
certification for individual products, go to www.ahridirectory.org
Daikin and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD.
Distributor or Dealer Information:
Residential and Light Commercial
4.0 TON
8-Zone Multi-SplitProduct Flyer 2013/9