Pelatihan Dmi Presentation

24

description

proses pelatihan dm dan pompa grounpose

Transcript of Pelatihan Dmi Presentation

AgendaWhat is Grundfos Remote Management?

System Features

Technical Details

Popular Applications.

Benefits of Grundfos Remote Management

What is Grundfos Remote Management?Easy-to-install, low-cost monitoring and management of pumping systems.

Web access to reports and trend data for all relevant employees.

Automatic event log and service log for all pumpsin the system.

Plug n´ Play integration with Grundfos Controls – monitoring of all pumps and sensors.

Centrally hosted database and application server. Users only need an Internet PC.

Alarms on SMS and Email distributed according to built-in week schedule.

System Features

Pre-defined drivers and lay-out for Plug n’ play monitoring

- Waste water pits

- Pressure Booster Systems

- Circulator pumps

- Fire Protection Systems

- External VFD

- E Pumps (integrated VFD)

- Motor Protection

- I/O Modules

Complete overview of all your pump installations organized in a logical navigation tree supported by your own site map or system drawing.

Installation is plug ‘n play in an easy-to-use 4-step wizard. No programmers needed to setup the system.

…and you’re products are monitored.

Step 1: Enter phone number and modem id.

Step 2: Give your installation a name.

Step 3: Let the modem auto-discover your Grundfos pumps and controls.

Step 4: Select the alarms you want to receive and how you want them to be delivered. (SMS or Email).

Get a complete log of alarms and warnings in one easy to manage log.

Direct alarms to on-duty staff automatically using easy-to-configure week schedules.

Optimize pump service by keeping track of operating hours and number of starts for each pump. Access online service manuals and videos directly.

Automatic log and trend of the key performance indicators in your system to document performance and reveal potential for improvement.

Upload system documentation to one secure place and make it accessible to all relevant personnel.

Get access to live data on your mobile phone. Acknowledge alarms and verify communication on-site during installation.

How does remote management help you save money?

• Follow the Specific Energy (kWh/ m3) of your system to reveal performance degradation over time due to e.g.:

– Normal wear and tear.– Leakage in the system.– Deposits in pipes.

• Service according to actual operating data such as:

– Operating hours.

– Number of pump starts.

– Increase in current consumption.

– Increase in motor temperature.

• Cut back on-site inspections.

– Why visit sites that you know are ok?

• Automate reporting on:

– Energy consumption

– Pumped volume

– …and other pumping system KPIs

Technical Details

System Description

Public GPRS Network

Local SMS Gateways(One per country)

Central Hosting Center Web Server and database

Grundfos WAN (Internet) Secure Internet

(SSL 128 bit)

Network level

CIU271GPRS and SMS ModemMultipurpose I/O deviceIntelligent data logger

MPC

MGE

Magna

DME

SP/SQ

CUE

MP204

IO351

I/O devices- Level sensors- Flow sensor- Pressure sensor- Temperature sensors- Pumps- Door alarms- Etc.

IO112

GENIBus

Site level

One CIU271 modem will monitor a network of Grundfos products

IO devices Controls E-Pumps Magna Pumps Motor Protection(MP204)

Drives (CUE)

You can monitor ANY standard pump using MP204 or CUE

What will MP204 tell you about the pump?

Insulation resistance before start-upMotor TemperatureOverload/underloadOvervoltage/undervoltagePhase sequenceDry running

Get alarms if thresholds are crossed for:Phase missingPower factorPower consumptionHarmonic distortionRun and start capacitor (single-

phase)…and more

Monitor operational profile – number of starts and operating time

Monitor current consumption

Monitor and report on energy consumption

What will CUE tell you about the pump?

Leakage CurrentMotor / Bearing TemperatureOverload / underloadOvervoltage/undervoltageMissing Phase

Get alarms if thresholds are crossed for:Motor phase failureDry runningSensor faults External Fault SignalSensor limits

…and more

Monitor specific energy (when flow meter is attached).

Monitor Speed / frequency of the pump

Monitor and report on energy consumption

Monitor ANY switch, sensor or meter using IO modules from Grundfos

Flow meters PT 100/1000 Temp. sensors

Pressure sensors Ultra sonic level sensors

Dry contacts from alarm panels

…and all other signals (0/4-20mA, 0-10V, Pulse)

Level switches

Modem variants

CIM270 Can be mounted inside Dedicated Controls and HM Large

CIU271

GPRS data logger for GENIbus networks with Built-in general purpose IO Board:2 digital Inputs2 Configurable Inputs (Digital or 0/4-20mA/0-10V) 1 Relay output ( (230V 2A)1 Signal output (0-10 V)1 Temperature input (PT100/PT1000)

CIU270

GPRS data logger for GENIbus networks. (Cost reduced version with no built-in IO capability).

Grundfos communication optionsCost

Functionality

Grundfos Remote

Management

CIM/CIU 100 LONCIM/CIU 150 ProfibusCIM/CIU 200 Modbus RTUCIM/CIU 300 BACnet MS/TPCIM/CIU 250 GSM/GPRS/SMS

SCADA/BMS

Systems

CIU250 Basic SMS

Coming in 2010

S E P R I Z A L

Service Department PT. Grundfos Pompa Direct: (021) 4606909Mobile: 0811917562E-Mail: [email protected]

Questions?