DUAL POOL 626TECHNICAL SPECIFICATION SHEETDOC. # PE-S-052
Screen Deck Type
# of Screen PanelsDeck Angle AdjustmentAdjustable While Drilling (AWD)Tensioning System (Primary Deck)
Screen Support/Panel (Primary)
Tensioning System (Scalping Deck)
Screen Support/Panel (Scalping)Screen Change Time
Pyramid (PMD)Pyramid (PMD+)Flat Scalping Deck Panels
PMDPMD+
Urethane
Desilter
Desander
Weir Feeder VE - P/N 16801-01-001 Hood P/N 16871-01
DESILTER / DESANDER (OPTIONAL) DOC # PE-S-06020 Way Cyclone with 4" Cones and Ball Valves P/N 13245-01
2 - 10" Cones P/N 12945-01-0073 - 10" Cones P/N 12945-02-007
16 Way Cyclone with 4" Cones and Ball Valves P/N 13245-0214 Way Cyclone with 4" Cones and Ball Valves P/N 13245-03
Primary Deck
Exhaust Fan and Lines NOT Included
4 Compression Pins per Panel providing approximately 2000 lbs force to hold each screen in place4 Elastomeric Screen Cushions2 Elastomeric Cross Supports2 Elastomeric Side Supports
G.A.: 16758-00 SERIES W.S.: 16876-00 SERIES
Double Deck Dual Pool Design
G FORCE: HIGH G MANUFACTURER: DERRICK CORPORATION
COUNTRY OF ORIGIN: USA SOUND: ≤ 78 dBA - 'A' WTD SOUND PRESSURE ISO 3744
SCREEN FRAME
MODEL: DERRICK DUAL POOL 626 (DP-626)
MACHINE TYPE: SHAKER, HIGH G LINEAR MOTION
w/ 1.5” High Pyramid Screen
12.0 ft² (1.1 m2)
Both SidesPanel Spring Assembly holds Urethane Screen Panels in place2 Elastomeric Stringer Protectors
Long-Life High Temperature approximately 180º F, 82º C Urethane
w/ 0.8” High Pyramid Screen
35.0 ft² (3.3 m2)29.1 ft² (2.7 m2)
Scalping Deck
VAPOR EXTRACTION (OPTIONAL) G.A. # 16760-00 SERIES
Self-Locking Hoods6" Victaulic Exhaust Fitting
Box Feeder VE - P/N 16808-01-001 Hood P/N 16770-01
Both SidesActuated Screen Compression System (ASCS)
TOTAL API NON-BLANKED SCREEN AREA
Weir Feeder P/N 16801-01Box Feeder P/N 16808-01
AVAILABLE FEEDER TYPES
AVAILABLE SCREENS
Approximately 0.5 - 1 Minute per Screen
10 Float Mount Isolators6 Primary - Air Actuated Compression, 24 Scalping
+1o to +7o
Push Button Electric Hydraulic Powered
DUAL POOL 626TECHNICAL SPECIFICATION SHEETDOC. # PE-S-052
Overall Equipment
Vibrating and AWD MotorsElectrical Circuit
Overall EquipmentMounting provisions for optional desander/desilter packages having up to twenty
Feeder
Electrical
Screen Frame
SAFETY FEATURESWarning labels advise personnel of potential hazards of moving equipment, high temperatures, and high voltage.Optional vapor extraction system to aid in removal of vapors.
Processing rates over 1500GPM, depending on mud density and screen panel type.
4” hydrocyclones - accepts up to three optional 10" desander cones.Ambidextrous design accommodates left- or right-hand installations.
PRODUCT FEATURES
Built-in scalping deck bypass standard on all feeders
Infinitely adjustable electric hydraulic AWD varies from +1° to +7°.Front-mounted AWD controls may be located remotely, if desired.
Weir feeder offers 34” weir height, Box feeder offers 45 1/2" weir height
Refer to DOC#PE-S-011
WARRANTYRefer to DOC#FI-C-003
Air-actuated screen compression offers positive locking, fast screen changing.
Press in place oil-resistant bed cushions offer complete sealing.
Urethane screen scalping deck provides efficient removal of coarse material increasing the life of primary deck screens.
Box Feeder VE 80 1/2” (2045 mm) 125" (3175 mm) 114 7/8" (2918 mm) 45 1/2" (1156 mm) 9700/4400
Up to 17% more API screen area than FLC-513.Unique concave primary screen design maximizes flow rate.Accepts Pyramid and Pyramid Plus screens for increased capacity.
STANDARDS FOR CONSTRUCTION
with Hydrocyclones
Box Feeder 80” (2032 mm) 125" (3175 mm) 114 7/8" (2918 mm) 45 1/2" (1156 mm) 9400/4264with Hydrocyclones
Weir Feeder VE 80 1/2” (2045 mm) 132 1/4" (3359 mm) 114 7/8" (2918 mm) 34" (864 mm) 9900/4491
Thermal overload protection switch.Automatic shaker shutdown if vibrating motor current overload or thermal overload occurs.
Weir Feeder VE 74 5/8” (1895 mm) 126 1/4" (3207 mm) 73 9/16" (1868 mm) 34" (864 mm) 5900/2676Weir Feeder 80” (2032 mm) 132 1/4" (3359 mm) 114 7/8" (2918 mm) 34" (864 mm) 9700/4400
with Hydrocyclones
with Hydrocyclones
Box Feeder VE 79” (2007 mm) 108" (2743 mm) 73 9/16" (1868 mm) 45 1/2" (1156 mm) 5800/2631Weir Feeder 74 5/8” (1895 mm) 126 1/4" (3207 mm) 73 9/16" (1868 mm) 34" (864 mm) 5700/2585
WEIGHTS & DIMENSIONS – EQUIPMENT (APPROXIMATE)
Box Feeder 79” (2007 mm) 108" (2743 mm) 73 9/16" (1868 mm) 45 1/2" (1156 mm) 5500/2495
DIMENSIONS (IN/MM)OPTIONS WIDTH LENGTH HEIGHT WEIR HEIGHT LBS/KG
DUAL POOL 626TECHNICAL SPECIFICATION SHEETDOC. # PE-S-052
STANDARD NEC/UL OPTIONS
OPTIONS are subject to Pricing,Scheduling & Engineering Design -
Contact Derrick Engineering
Hazardous AreaProtection Type IP 56
60Hz / 3 Phase 460/480V 575/600V 230/240V, 380/400V, 440VPower Requirement 3.8kVA 3.8kVA
50Hz / 3 Phase 380/400V 230/240V, 415V, 440VPower Requirement 3.8kVA
VolumeAir Quality
ModelQuantityPower
Lubrication
QuantityPower
OPTION #1:Standard Option Local/Onboard Control: Remote Control Panel:
Magnetic starters in an enclosurebuttons to energize the unit (ON/OFF) and raise that is supplied loose. A controland lower the screen bed angle (UP/DOWN) station on the front of the Unit.
A Junction Box will be provided atthe unit for motor connections andsupply wiring.OPTION #2:
Remote Control Panel:Same as Option #1 & the additionof an auxiliary control station(also supplied loose)OPTION #3:Remote Control Panel:A Junction Box will be provided at
the unit for motor connections andsupply wiring. A control station onthe front of the Unit.
CONTROLS
Magnetic starters in an enclosure with push
actual power.
Approximately 1HP (varies between 0.75 – 0.9 kW) 1
(See motor specification sheet for details)
22.5 HP (1.87 kW) Each
actual power. Continuous Oil Bath (See motor specification sheet for details)
AWD MOTOR
Power is approximate as several variables affect the
VIBRATING MOTORSG3X
NEMA 4, 7 & 9 // INGRESS PROTECTION (IP 55) Minimum
Power is approximate as several variables affect the
NOTE: Contact Derrick Engineering for any power configuration not listed.
COMPRESSED AIR90 PSI @ 1 CFM MinimumCompressed Air
UTILITIES
EQUIPMENT RATING
NEC/UL: CLASS I, DIV 1, GROUPS C&D
UTILIZATION VOLTAGE
DUAL POOL 626TECHNICAL SPECIFICATION SHEETDOC. # PE-S-052
AVAILABLE I.E.C. OPTIONS
OPTIONS are subject to Pricing,Scheduling & Engineering Design -
Contact Derrick Engineering
Hazardous Area ZONE 1, 2G Ex de IIB
Protection Type IP 56
60Hz / 3 Phase 460/480V 575/600V 230/240V, 380/400V, 440V, 690VPower Requirement 3.8kVA 3.8kVA
50Hz / 3 Phase 380/400V 230/240V, 415V, 440V, 690VPower Requirement 3.8kVA
VolumeAir Quality
Model SG3XQuantity 2Power 2.5 HP (1.87 kW) Each
Lubrication Continuous Oil Bath
Quantity 1Power
OPTION #1:Standard Option Local/Onboard Control: Remote Control Panel:
Magnetic starters in an enclosurebuttons to energize the unit (ON/OFF) and raise that is supplied loose. A controland lower the screen bed angle (UP/DOWN) station on the front of the Unit.
A Junction Box will be provided at
the unit for motor connections andsupply wiring.OPTION #2:Remote Control Panel:Same as Option #1 & the additionof an auxiliary control station(also supplied loose)OPTION #3:Remote Control Panel:A Junction Box will be provided atthe unit for motor connections andsupply wiring. A control station onthe front of the Unit.
EQUIPMENT RATING
UTILIZATION VOLTAGE
NOTE: Contact Derrick Engineering for any power configuration not listed.
(See motor specification sheet for details)
I.E.C.: ZONE 1, 2G Ex d IIB MinimumINGRESS PROTECTION IP 55 Minimum
UTILITIES
VIBRATING MOTOR
COMPRESSED AIR90 PSI @ 1 CFM MinimumCompressed Air
AWD MOTOR
Magnetic starters in an enclosure with push
Power is approximate as several variables affect theactual power.
(See motor specification sheet for details)
Approximately 1HP (varies between 0.75 – 0.9 kW) Power is approximate as several variables affect theactual power.
CONTROLS
DUAL POOL 626TECHNICAL SPECIFICATION SHEETDOC. # PE-S-052
AVAILABLE ATEX OPTIONS
OPTIONS are subject to Pricing,Scheduling & Engineering Design -
Contact Derrick Engineering
Hazardous Area ZONE 1, 2G Ex de IIB
Protection Type IP 56
60Hz / 3 Phase 460/480V 575/600V 230/240V, 380/400V, 440V, 690VPower Requirement 3.8kVA 3.8kVA
50Hz / 3 Phase 380/400V 230/240V, 415V, 440V, 690VPower Requirement 3.8kVA
VolumeAir Quality
Model SG3XQuantity 2Power 2.5 HP (1.87 kW) Each
Lubrication Continuous Oil Bath
Quantity 1Power
OPTION #1:Standard Option Local/Onboard Control: Remote Control Panel:
Magnetic starters in an enclosurebuttons to energize the unit (ON/OFF) and raise that is supplied loose. A controland lower the screen bed angle (UP/DOWN) station on the front of the Unit.
A Junction Box will be provided atthe unit for motor connections andsupply wiring.OPTION #2:Remote Control Panel:Same as Option #1 & the additionof an auxiliary control station(also supplied loose)OPTION #3:Remote Control Panel:A Junction Box will be provided atthe unit for motor connections andsupply wiring. A control station onthe front of the Unit.
actual power. (See motor specification sheet for details)
CONTROLS
Magnetic starters in an enclosure with push
(See motor specification sheet for details)
Power is approximate as several variables affect the
Approximately 1HP (varies between 0.75 – 0.9 kW) Power is approximate as several variables affect the
AWD MOTOR
actual power.
VIBRATING MOTOR
90 PSI @ 1 CFM Minimum
NOTE: Contact Derrick Engineering for any power configuration not listed.
COMPRESSED AIR
ATEX.: ZONE 1, 2G Ex d IIB Minimum
Compressed Air
INGRESS PROTECTION IP 55 Minimum
EQUIPMENT RATING
UTILIZATION VOLTAGE
UTILITIES