User Manual PD_OperaMa_ENI-4_en.doc Article number: 17130107-001 Edition: 10.2004 PacDrive TM ENI-4 Server

Transcript of PD_OperaMa_ENI-4_en0410.pdf

Page 1: PD_OperaMa_ENI-4_en0410.pdf

User Manual

PD_OperaMa_ENI-4_en.doc Article number: 17130107-001 Edition: 10.2004

PacDriveTM ENI-4 Server

Page 2: PD_OperaMa_ENI-4_en0410.pdf

Impressum

Page 2 User Manual ELAU AG

PD_O

pera

Ma_

EN

I-4_e

n.do

c

IMPRINT

© All rights reserved to ELAU AG, also in case of patent rightapplications.

No part of this documentation and the related software and firmwaremay be reproduced, rewritten, stored on a retrieval system, transmittedor translated into any other language without the express written consentof ELAU AG.

Any possible measure was taken to ensure that this productdocumentation is complete and correct. However, since hardware andsoftware are continuously improved, ELAU makes no representations orwarranties with respect to the contents of this documentation.

Trademarks:

PacDrive is a registered trademark of ELAU AG.

All other trademarks mentioned in this documentation are the exclusiveproperty of their manufacturers.

ELAU AG ELAU Inc.Dillberg 12 165 E. Commerce DriveD-97828 Marktheidenfeld Schaumburg, IL 60173

Phone: +49 (0) 93 91 / 606 - 0 Phone: 847 490 4270Fax: +49 (0) 93 91 / 606 - 300 Fax: 847 490 4206

eMail: [email protected] [email protected]: http://www.elau.de http://www.elau.com

Page 3: PD_OperaMa_ENI-4_en0410.pdf

Contents

ELAU AG User Manual Page 3

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Contents1 General 51.1 Overview .....................................................................................................................51.1.1 Supported Database Systems....................................................................................51.1.2 Communication with the ENI-4 Server .......................................................................51.1.3 ENI-4 in Combination with EPAS-4 ............................................................................51.1.4 Installation and Start ...................................................................................................61.2 System Requirements .................................................................................................61.2.1 Software (operating system):......................................................................................61.2.2 Hardware....................................................................................................................6

2 Installation 72.1 Installing the Version Management Tool......................................................................72.1.1 Microsoft Visual Source Safe 6.0 (VSS 6.0)...............................................................82.1.2 PVCS Version Manager 7.5.1 ....................................................................................82.2 Installing the ENI-4 Server ........................................................................................102.2.1 Preparing the Installation..........................................................................................102.2.2 Installation ................................................................................................................102.2.3 Linking the Version Management to ENI-4...............................................................132.2.4 Completing the Installation .......................................................................................162.3 Administration and Configuration of the ENI-4 Server ..............................................182.3.1 ENI Control ...............................................................................................................182.3.2 ENI Admin ................................................................................................................19

3 Connecting an EPAS-4 Project 21

4 Licensing 234.1 General .....................................................................................................................234.2 Installing the License.................................................................................................234.2.1 Licensing Procedure via Telephone..........................................................................234.2.2 Licensing Procedure via E-Mail ................................................................................264.3 Hardware Changes in the Computer of the ENI-4 Server .........................................304.4 The ENI-4 Server Is Installed on a New Computer ...................................................30

5 Working with ENI-4 315.1 FAQ (Frequently Asked Questions)...........................................................................315.1.1 Driver Selection for Visual Source Safe 6.0 not Possible.........................................315.1.2 Error Message during Driver Selection ....................................................................315.2 Notes on the Version Management Tools..................................................................315.2.1 PVCS Version Manager 7.5.1 ..................................................................................31

6 Appendix 336.1 ENI Control................................................................................................................336.1.1 Starting ENI Control..................................................................................................336.1.2 Starting ENI Admin ...................................................................................................356.2 Contact Addresses ....................................................................................................37

Page 4: PD_OperaMa_ENI-4_en0410.pdf

Contents

Page 4 User Manual ELAU AG

PD_O

pera

Ma_

EN

I-4_e

n.do

c

6.3 Further Literature ......................................................................................................386.4 Product Training ........................................................................................................406.5 Index .........................................................................................................................41

Page 5: PD_OperaMa_ENI-4_en0410.pdf

1.1 Overview

ELAU AG User Manual Page 5

PD_O

pera

Ma_

EN

I-4_e

n.do

c

1 General

This document gives an overview of the functionality of ENI-4. At thesame time, it includes an instruction for the installation and initialconfiguration of the ENI-4 server with regard to the connection of anEPAS-4 project to a database. The programs ENI Admin and ENI Control,which are needed for the administration of the ENI-4 Server, are installedat the same time. The tool ENI Explorer can be installed by means of theuser-defined installation.

1.1 Overview

ENI-4 is the ENgineering Interface of the EPAS-4 programming system. Itconsists of a server and a client part. The ENI-4 server runs as aseparate service. Typical clients are one or several EPAS-4programming systems and tools accessing the same sources managedin a common data storage system. The use of ENI-4 offers someessential advantages. For the work with EPAS-4, it permits a versionmanagement for EPAS-4 projects, multi-user operation and access tothe project database by external programs.

1.1.1 Supported Database Systems

The server concept enables working with access to a common databaseinstalled on a remote computer. By default, the ENI-4 Server currentlysupports a local file system and the database systems ‘Microsoft VisualSourceSafe’, ‘MKS Source Integrity’ and ‘PVCS Version Manager’.

1.1.2 Communication with the ENI-4 Server

The connection between client and ENI-4 Server requires TCP/IP.Therefore TCP/IP must be installed both on the client and on the server.

1.1.3 ENI-4 in Combination with EPAS-4

The use of ENI-4 in the EPAS-4 programming system is optional. Forfurther information on this project option, please see User ManualEPAS-4.

ELAU AG recommends not to use ENI for versions older than EPAS-4V16.

Page 6: PD_OperaMa_ENI-4_en0410.pdf

General

Page 6 User Manual ELAU AG

PD_O

pera

Ma_

EN

I-4_e

n.do

c

1.1.4 Installation and Start

The ENI-4 Server is installed by means of a separate setup (see chapter 2Installation). After the installation and after restarting the computer, theavailability of the ENI-4 Server is indicated by an icon in the Windows taskbar and the ENI-4 Server is started automatically as a service.As long asthe ENI-4 server is running, the icon is highlighted.

1.2 System Requirements

1.2.1 Software (operating system): Windows NT 4.0 (SP6) with Internet Explorer 4.01 or higher

Windows 2000

Windows XP Professional

NOTE

If you are using ENI-4 for version management, additionally observe thesystem requirements of the version management software!

1.2.2 Hardware

At least the requirements for the flawless operation of the installedoperating system must be fulfilled.

Page 7: PD_OperaMa_ENI-4_en0410.pdf

2.1 Installing the Version Management Tool

ELAU AG User Manual Page 7

PD_O

pera

Ma_

EN

I-4_e

n.do

c

2 Installation

By all means, you should observe the following order when installing theENI-4 server.

Installing the Version Management Tool (see chapter 2.1)

Installing the ENI-4 Server (see chapter 2.2)

Administration and Configuration of the ENI-4 Server (see chapter 2.3)

NOTE

The following points must absolutely be observed during the installation:

Observe system requirements!

To install and manage the ENI-4 Server, the user must haveadministrator rights.

By all means observe the order of installation!

If you want to use the ENI-4 without Version Management Tool, youcan skip the chapter “Installing the Version Management Tool”.

Ideally, the Version Management Tool is located on the same serveras the ENI-4 Server.

2.1 Installing the Version Management Tool

Currently drivers are available to use ENI-4 with the version managementtools Microsoft Visual Source Safe, MKS Source Integrity and PVCSVersion Manager. For installation, please also observe the installationinstructions for the respective tool. This chapter gives a short descriptionof the configuration of the version management tool for ENI-4 for MicrosoftVisual Source Safe 6.0 and PVCS Version Manager 7.5.1.

NOTE

Ideally, the version management tool should be installed on the samecomputer as the ENI-4 server!

In version V00.01.01. SP2, you have to install the SourceSafe databasein the same folder as the SourceSafe installation (e.g. the defaultdatabase of SourceSafe).

After installing the version management tool, restart the PC.

Page 8: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 8 User Manual ELAU AG

PD_O

pera

Ma_

EN

I-4_e

n.do

c

2.1.1 Microsoft Visual Source Safe 6.0 (VSS 6.0)

Install VSS 6.0 as described in the enclosed installation instruction. Asthe type of installation, choose “independent application”. Activate theoption “Use new VSS DB format”.

How to create a new database with VSS 6.0: Start "Visual Source Safe 6.0 Admin"

Menu “Tools” -> “Create database …”

In the window “Create new VSS database” -> enter directory andactivate option “New 6.0 database format”.(The directory should be located on the ENI-4 server.)

Confirm with “OK”.

2.1.2 PVCS Version Manager 7.5.1

Install the PVCS Version Manager 7.5.1 as described in the enclosedinstallation instruction.

NOTE

Ideally, the version management tool should be installed on the samecomputer as the ENI-4 server!

As the setup type of the installation, select the option “Local”.During the installation, a variety of features is offered.

Activate the features PVCS Version Manager and PVCS VMCommand-Line.

How to create a new database with PVCS Version Manager (PVCSVM):

NOTE

You can also use an existing database for ENI-4. Please also observethe notes on driver configuration during the ENI-4 installation.

Call up "Admin"->"Create Project Database...".Fill in the two dialog fields (see Fig. 2-1 and Fig. 2-2).

Page 9: PD_OperaMa_ENI-4_en0410.pdf

2.1 Installing the Version Management Tool

ELAU AG User Manual Page 9

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Fig. 2-1: Settings Create Project Database - Tab General

Fig. 2-2: Settings Create Project Database - Tab Advanced

When using access control database security, create an unrestricteduser eni with password eni.

Create an account for each user that is to have access to thedatabase.

NOTE

To update the PVCS GUI surface automatically, “Access ControlDatabase” must be set. The login dialog must be activated in the menu"Configure->General->Security->Login Sources" and it must be at thetop of the list.

Create a new temporary directory: e.g. c:\temp

Page 10: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 10 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

2.2 Installing the ENI-4 Server

2.2.1 Preparing the Installation

If you are using the ENI-4 Server with the database “Local file system”,create a new directory on the computer of the ENI-4 Server. After theinstallation, future objects will be saved there.

If you are using the ENI-4 Server with a version management tool, theinstallation of the version management tool must have been completedcorrectly before you install the ENI-4 server.

NOTE

With the help of the ENI-4, you can use the possibilities of a versionmanagement tool for your EPAS-4 projects. However, this does notrelieve you from the task of implementing a mechanism for data safety.For this reason, you should save your database in regular intervals.

2.2.2 Installation

How to install the ENI-4 server: Insert ENI-4 Server installation CD.

Select the language to be used for the installation.

Fig. 2-3: Language selection

Follow the instructions of the installation routine.You have to agree to the license agreement of ELAU AG and enteryour name and/or the name of your company. The CD-key can befound on the label on the CD case.

Activate the option “Install this application for: Anyone who uses thiscomputer (all users)”!

Page 11: PD_OperaMa_ENI-4_en0410.pdf

2.2 Installing the ENI-4 Server

ELAU AG User Manual Page 11

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Fig. 2-4: Customer Information

Then enter the target path to which you wish to install the ENI-4 Server.

Fig. 2-5: Choose Destination Location

As setup type, select “Typical”.Now the installation procedure is started and the status is shown inthe following dialog:

Page 12: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 12 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Fig. 2-6: Setup Status

After successful installation, the following dialog field appears:

Fig. 2-7: Installation completed

If there were any problems during the installation, please restart thesetup. By all means observe the order of installation.

Page 13: PD_OperaMa_ENI-4_en0410.pdf

2.2 Installing the ENI-4 Server

ELAU AG User Manual Page 13

PD_O

pera

Ma_

EN

I-4_e

n.do

c

2.2.3 Linking the Version Management to ENI-4

After the installation of the ENI-4 Server, the version management tool hasto be configured in the ENI. Start the tool "ENI Control" via the Start menu"Programs->ELAU->Engineering Interface ENI-4 V1->ENI Control" or byright-clicking with the mouse on the ENI symbol of active programs in thetask bar.

NOTEFirst the dialog ‘Enter Administrator Password’ appears. If you areinstalling the ENI Admin module for the first time, there is no password.Enter no password in the field "Please enter the administratorpassword", confirm the dialog with “OK”. You can enter an administratorpassword later on in the tool ENI Admin. If you installed the ENI Adminmodule before, you have to enter the valid administrator password.

Fig. 2-8:Administrator password

This opens the dialog window “ENI Control” with the category‘Database’, where the user can set the driver for the desired databaseas described below.

Fig. 2-9: Driver selection

Page 14: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 14 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Now select the driver you need for your database. Depending on yourselection, continue the installation in the corresponding section. Makethe settings required for the chosen driver.

You can find all installed drivers in the selection box next to 'SelectDatabase Driver'. If the desired driver is not included in the list, click onthe first button next to the list and select the corresponding driver file onthe computer. The following driver files are currently available:

"File System Driver" (ENIDrvFileSystem.edd, local file system)

"MKS Source Integrity" (ENIDrvMKS.edd)

"SourceSafe 6.0" (ENIDrvSourceSafe6.edd)

"PVCS Version Manager 7.5.1" (ENIDrvPVCS.edd)

As the root folder, enter the directory you created during yourpreparation.

To set the path, you can use the browse dialog, which is opened bydouble-clicking on the input field.

Do not change the ENI user name. ENI should be entered here.

Enter the project path you created during your preparation. This pathmust include the file *.pi!

To set the path, you can use the browse dialog, which is opened bydouble-clicking on the input field.

In the field “Temporary folder” you can enter a folder for savingtemporary files.

Under Host, enter the name of the database computer.

Under Port, enter the port of the database computer. (Default: 7001 – if nochanges were made during the installation of the database).

Under ENI user, enter a specific user account used by the ENI-4 Serverfor internal tasks. This account must have been created in the usermanagement of the database. In the field “ENI password”, enter thepassword for the above user account.

Location of 'srcsafe.ini':Enter the project path you created during your preparation. The directorywith this project path must include the file "srcsafe.ini"!To set the path, you can use the browse dialog, which is opened bydouble-clicking on the input field.

Root project:If you created a root project when creating the project with VSS 6.0,enter it in the field “Root project”.

Temporary folder:The field “Temporary folder” has no relevance when using the versionmanagement tool.

ENI user, ENI password:Do not change the default settings for “ENI User” and “ENI password”,unless you previously created a separate account for the ENI-4 in

File System Driver

MKS Source Integrity

Source Safe 6.0

Page 15: PD_OperaMa_ENI-4_en0410.pdf

2.2 Installing the ENI-4 Server

ELAU AG User Manual Page 15

PD_O

pera

Ma_

EN

I-4_e

n.do

c

SourceSafe Admin or you deleted the default user Guest in SourceSafeAdmin.

Location of 'ss.exe':Enter the path to the file ss.exe.

Example:If you installed Visual SourceSafe in the directory"c:\Program Files\Microsoft Visual Studio\VSS",you have to enter the following path:"c:\Program Files\Microsoft Visual Studio\VSS\win32".

Projects File:Several databases of PVCS Version Manager can be addressed via theENI-4. For this purpose, the databases need to be made known to the ENI-4. This requires the file Projects.ini. All databases and the correspondingarchives to be addressed via the ENI-4 must be entered in this file. If a newdatabase is created, the file needs to be adjusted. A sample file can befound in the ENI-4 program folder(Default: C:\Program Files\ELAU\ENI-4 V1\Projects.ini).It must be a plain text file with the following structure:

[Projects]xxx=yyydefault=yyy[Archives]xxx=yyy\archivesdefault=yyy\archives

The entries [Projects] with the keyword "default" and [Archives] with thekeyword "default" are important. They must always exist. The existingdatabases are entered in the [Projects] section, while the archives of therespective databases from the [Projects] section are entered in the[Archives] section (usually this means adding “\archives” to the projectname). In addition to the keyword “default”, you always have to enter thedatabase directory of the default database and the archive directory ofthe matching database after the “=” sign. You can enter any number ofdatabases. Please note that the placeholder xxx represents the name ofthe database in the ENI-4 and yyy always represents the folder of thecorresponding database.

Example:[Projects]Datenbank_01=d:\Datenbank_02Datenbank_02=d:\Datenbank_03default=d:\Datenbank_01[Archives]Datenbank_01=d:\Datenbank_02\archivesDatenbank_02=d:\Datenbank_03\archivesdefault=d:\Datenbank_01\archives

All databases (in this example, Datenbank_02 and Datenbank_03) inherittheir properties from the default database. For this reason, all databasesmust use the same configuration file and the same access control databaseof the default database (in this example, in folderd:\Datenbank_01\archives). You can save the projects to any place you like.

PVCS Version Manager

Page 16: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 16 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Temporary folder:Enter the temporary folder you created when creating the new projectdatabase PVCS VM (in this example, C:\temp).

ENI-4 user, ENI-4 password:As soon as the option "Access control database security" is activated inPVCS VM, you have to enter a user and password that is valid in PVCSVM. A user “eni” was created during the installation of PVCS VersionManager. For this reason, enter the user “eni” with password “eni”.

PVCS Dll Path:Enter the path to the file vmwfdtk.dll. Example: If you installed PVCS VMin the directoryc:\Program Files\vm, you have to enter the following path:"c:\Program Files\pvcs\vm\common\bin\win32" (If you selected thedefault path during the installation of PVCS VM, you do not need tomake any settings here).

PVCS Configuration File:Enter the path of the configuration file (*.cfg). By default, it is located inthe subdirectory “archives” of the project directory you created whencreating the new project database PVCS VM (in this example,"d:\PVCS_ENI-4_Project_Folder\archives"). This directory includes a filewith the extension *.cfg. Please select this file in the file selection box. Allother databases have to use the same configuration file. For this reason,you should always select "Use an existing Configuration File" and "Usean existing Access Control Database" in the tab "Advanced" whencreating new projects.

Update PVCS GUI?:Enables an automatic update of the PVCS surface. Please note that it takesmore time to create and delete objects, rather than to deactivate the option.

NOTE

To update the PVCS GUI surface automatically, an “Access ControlDatabase” must be set. The login dialog must be activated in the menu"Configure->General->Security->Login Sources" and it must be at thetop of the list.

When using the PVCS Version Manager, also observe the notes inChapter "Completing the Installation"!

2.2.4 Completing the Installation

When you start up your system, the ENI-4 Server should now startautomatically and be ready to use. In this case, the ‘Current Status’Running is shown in ENI Admin and the ENI-4 icon in the task bar ishighlighted.

After a successful installation and every time the computer is started, theENI-4 Server service is started automatically, the ENI-4 icon in the taskbar is highlighted.

Page 17: PD_OperaMa_ENI-4_en0410.pdf

2.2 Installing the ENI-4 Server

ELAU AG User Manual Page 17

PD_O

pera

Ma_

EN

I-4_e

n.do

c

NOTE If PVCS Version Manager is used as a version management tool, a

special account must be created for the service ENI-4 Server.

How to create a special account for the ENI-4 Server: Create a separate account in the user management of the operating

system on the ENI-4 server.(Give the account administrator rights; the password must notchange or expire).“Start->System management->User accounts”

Then restart the tool “ENI Control”.

Open the “Service” category.

Stop the service with the button “Stop Service”.

Click on the button "Advanced Control".

The following dialog will appear:

Fig. 2-10: Advanced control

Deactivate the option "Local System Account" and activate theoption "Specified Account". Then enter the user and password of theaccount you set up according to the above description(In this example, an account “eni” was set up – please note theWindows conventions, e.g. “\”).

Exit the dialog with OK.

Start the service with the button "Start Service"

NOTE

The ENI-4 server is now fully functional for 30 days. After expiry ofthose 30 days, the ENI-4 Server can only be used locally. Therefore youshould contact ELAU AG immediately after the installation in order toobtain a permanent license for the ENI-4 Server. Please note Chapter4.0.

After the installation is completed, restart the PC.

Page 18: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 18 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

2.3 Administration and Configuration of the ENI-4 Server

NOTE

The installation and administration of the ENI-4 Server with the toolsENI Admin and ENI Control require administrator rights.

The software also includes the installation of the programs ENI Controland ENI Admin for the administration and handling of the ENI-4. If youopt for a user-defined installation (select “Tools”!) you can additionallyselect the tool ENI Explorer. However, this program is not serviced andmaintained by ELAU AG. Should you have any questions on handlingENI-4 Explorer, please check the online help.

NOTE

ENI Control and ENI Admin must be started separately, but cannot runat the same time. After the installation, these programs can be found inthe Start menu of the ENI-4 Server. They are also available via themenu that opens when you right-click on the ENI icon in the task bar.

2.3.1 ENI Control

With ENI Control, you can make basic server settings that cannot bechanged during operation, e.g. database connection, communicationsettings etc. Moreover, the ENI-4 Server can be started and terminatedwith ENI Control.

Further information is available in the online help.

Page 19: PD_OperaMa_ENI-4_en0410.pdf

2.3 Administration and Configuration of the ENI-4 Server

ELAU AG User Manual Page 19

PD_O

pera

Ma_

EN

I-4_e

n.do

c

2.3.2 ENI Admin

With ENI Admin, you can configure users, groups and access rights andexecute license management functions even during operation.

User administration can be organized with the tool ENI Admin.

NOTE

In connection with ENI Admin, please observe the following notes:

If Visual Source Safe 6.0 is used as a version management tool,there are restrictions in the individual selection of user name andpassword. Each may consist of a maximum of 6 characters.

The tool ENI Admin can only be started if the ENI-4 Server isrunning.

During a first installation, no password has been assigned; simplyenter no password when you start ENI Admin and confirm the dialogwith OK.

To establish a data connection via ENI-4 to the database, it is sufficientto be validly registered as a user in the database. However, an additional(previous) user definition in the ENI-Server may be sensible if e.g.detailed access rights are to be defined.

For the definition of users in the ENI-4, please note:To be able to use a user account created in ENI Admin, a correspondingaccount (with identical name and password) must exist in the database.

Each user account should be assigned to a group. For this purpose,select the desired group, click on ‘Edit’ and add the desired useraccounts to the group.

Further information is available in the online help.

For Visual SourceSafe, for example, use Visual SourceSafe Admin foruser administration. Make sure that the right database is opened in theversion management tool.

Page 20: PD_OperaMa_ENI-4_en0410.pdf

Installation

Page 20 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Page 21: PD_OperaMa_ENI-4_en0410.pdf

2.3 Administration and Configuration of the ENI-4 Server

ELAU AG User Manual Page 21

PD_O

pera

Ma_

EN

I-4_e

n.do

c

3 Connecting an EPAS-4 Project

The following example describes how objects of an EPAS-4 project arecreated via the ENI-4 server in the database defined there.

Start the EPAS-4 programming system and open any project.

Select the command ‘Project’ ‘Options’ ‘Project Source Control’

Activate the option ‘Use Source Control (ENI-4)’

Click on ‘Configure ENI-4…’

In the category ‘Project objects’, configure the ENI-4 connection asfollows:

Set TCP/IP address:Computer on which the ENI-4 Server is installed, e.g. "10.201.17.122"

Set port:Number of the port on which the ENI-4 Server is listening.Default: 80.

Enter project name:Name or path of the project as it should appear in the database inthe path entered under Root for Database connection in ENI Admin(e.g. "project1\projektobjekte" -> appears in Visual SourceSafeunder $/project1/projektobjekte if “$/” was defined as Root).

All other settings remain unchanged.

Click on ‘Next’:For this introductory example, make the same entries in thecategories ‘Shared objects’ and ‘Compile user files’ as in ‘Projectobjects’

Quit optional dialogs with OK:You are asked to log into the ENI-4 Server: Enter name andpassword of a valid user account

At this point the project is connected to the database, but the functionblocks as such are only saved “locally”. To transmit them to thedatabase, proceed as follows:

Select the command ‘Project’ ‘Data Base Link’ ‘Multiple Define’

In the Object properties dialog, select the database option ‘Project’

A file tree is opened.

In the file tree, select all function blocks you wish to save in thedatabase.

Confirm with OK

Now the selected function blocks you configured in the optional dialog‘Project objects’ are linked to the database. For these function blocks, alltypical database functions are now available in the context menu.

Page 22: PD_OperaMa_ENI-4_en0410.pdf

Connecting an EPAS-4 Project

Page 22 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Page 23: PD_OperaMa_ENI-4_en0410.pdf

4.1 General

ELAU AG User Manual Page 23

PD_O

pera

Ma_

EN

I-4_e

n.do

c

4 Licensing

4.1 General

In the installation procedure, select the driver you need for your versionmanagement tool and/or file system. Then you can test the ENI-4 Serverfor 30 days free of charge.

NOTE

The license expires automatically after 30 days. After that, you can usethe ENI-4 Server only from the local host. For this reason, it isabsolutely necessary to extend your license in good time before the 30-day demo mode expires. We recommend that you contact ELAU AG assoon as you have completed the installation.

4.2 Installing the License

4.2.1 Licensing Procedure via Telephone

Open the dialog "License Management":

NOTE

Instructions on how to start the tools can be found in the appendix.

ENI Control via button "License Management ..." ENI Admin via button "License Mngmt."

↓ ↓

Step 1

Page 24: PD_OperaMa_ENI-4_en0410.pdf

Licensing

Page 24 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

NOTE

This dialog shows the actual licensing information. If no licensingprocedure has been executed, the value for "Max. user count:" is"three", the value for "Expires" is "in 29 days".

Start the license wizard:

In the dialog “License Management” (which you started via ENI Control orENI Admin) start the license wizard by clicking on the button “Request”.

Create "Module ID", "feature changes" and "Request Key"

↓(If the server is licensed for the first time, you need to select the moduleENI-4 Server in another window).

↓NOTE Allow remote access -> "Desired value" must be "Yes" Max. user count

- Current value: Old value before new licensing- Desired value: New value must be identical with the ELAU order

(equivalent to the number of workplace licenses ordered).

Step 2

Step 3

Page 25: PD_OperaMa_ENI-4_en0410.pdf

4.2 Installing the License

ELAU AG User Manual Page 25

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Select “Activate via phone”!

NOTEIn this dialog you are now required to contact ELAU AG to give us theModule ID, feature changes and Request Key. All data are casesensitive!!!

↓Based on the data provided by you, ELAU AG then generates a "LicenseKey". Enter this “License Key” in the last dialog of the license wizard.

Click on the button “Finish” to check the license key and take it over intothe system. If there is an error message, click on the button “Back” toreturn to the dialog showing "Module ID", "feature changes" and"Request Key". Compare the date shown there to the ELAU data.

Page 26: PD_OperaMa_ENI-4_en0410.pdf

Licensing

Page 26 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

After you close the dialog, the “License Management” box shows thenew values.

Click on “Close” to close this dialog.

↓Then you need to stop and restart the ENI-4 Server. This is indicated bya message box:

In the window ENI Control, click on “Stop Service”, then on “StartService”. The changes will be taken over.

4.2.2 Licensing Procedure via E-Mail

Call up the dialog "License Management"

NOTE

Instructions on how to start the tools can be found in the appendix.

ENI Control via button "License Management ..." ENI Admin via button "License Mngmt."

↓ ↓

NOTE

This dialog shows the actual licensing information. If no licensingprocedure has been executed, the value for "Max. user count:" is"three", the value for "Expires" is "in 29 days".

Step 1

Page 27: PD_OperaMa_ENI-4_en0410.pdf

4.2 Installing the License

ELAU AG User Manual Page 27

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Start the license wizard

In the dialog “License Management” (which you started via ENI Control orENI Admin) start the license wizard by clicking on the button “Request”.

Create "Module ID", "feature changes" and "Request Key".

↓(If the server is licensed for the first time, you need to select the moduleENI-4 Server in another window)

↓NOTE Allow remote access -> "Desired value" must be "Yes"

Max. user count - Current value: Old value before new licensing

- Desired value: New value must be identical with the ELAU order(equivalent to the number of workplace licenses ordered).

Step 2

Step 3

Page 28: PD_OperaMa_ENI-4_en0410.pdf

Licensing

Page 28 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Select “Activate via mail”!

NOTE

To activate a license via e-mail, you need a properly installed e-mailclient.

↓Complete the fields in the following dialog.

↓The button “Finish” closes the wizard and creates an e-mail message.

Page 29: PD_OperaMa_ENI-4_en0410.pdf

4.2 Installing the License

ELAU AG User Manual Page 29

PD_O

pera

Ma_

EN

I-4_e

n.do

c

The message is sent to [email protected] . After the message wassent successfully, the license wizard is closed. You will soon receive areply from ELAU AG by e-mail or telephone.

↓Once you received the message with the license key from ELAU, openthe “License Management” dialog again.

Click on “Install” to upload the license key saved in the file (*.3sl).

↓In the following box, select the file.

.

Once you clicked on the file and selected it with “Open”, the new licensekey is read in.

↓After you close the window, the new values are shown in the “LicenseManagement” box (you may have to close the “License Management”box and reopen it so that the license information matches the expectedresult).

Page 30: PD_OperaMa_ENI-4_en0410.pdf

Licensing

Page 30 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Click on “Close” to close this dialog.

↓Then stop the ENI-4 Server and restart it. This is indicated by a messagebox:

In the window ENI Control, click on “Stop Service”, then on “StartService”. The changes will be taken over.

4.3 Hardware Changes in the Computer of the ENI-4Server

The licensing of the ENI-4 Server includes the hardware of the PC onwhich the ENI-4 Server is installed. If the ENI-4 Server is installed onanother system, you need to request a new license from ELAU AG. Youmay also have to request a new license if certain hardware componentsin the PC are changed.

The following algorithm is used to detect the unambiguous system IDwhen installing the ENI-4 Server license: If there are one or severalnetwork cards, the MAC address of the primary network card is used. Ifthere is no network card, the serial number of the system hard disk isused.

This results in the following cases that require new licensing:

The primary network card is removed or replaced by a new one.

There was no network card in the PC. Now a network card isinstalled.

There is no network card: The system hard disk is replaced or theboot directory is moved to another disk.

In all three cases, you need to request a new license from ELAU AG.

4.4 The ENI-4 Server Is Installed on a New Computer

You need to execute a new licensing procedure. Please start thelicensing procedure via telephone or e-mail.

Page 31: PD_OperaMa_ENI-4_en0410.pdf

5.1 FAQ (Frequently Asked Questions)

ELAU AG User Manual Page 31

PD_O

pera

Ma_

EN

I-4_e

n.do

c

5 Working with ENI-4

5.1 FAQ (Frequently Asked Questions)

5.1.1 Driver Selection for Visual Source Safe 6.0 not Possible

After the installation of the ENI-4 Server, the driver for Visual SourceSafe 6.0 is not available in the tool ENI Config.

Install Visual SourceSafe 6.0. Then restart the tool ENI Config, switch tothe category “Database” and click on the “Browse Driver” button next tothe selection menu “Select Database Driver” to select the driver. Thedriver is located in the directory “Drives” in the ENI-4 program directory.

5.1.2 Error Message during Driver Selection

You receive the error message "An error occurred during initializing thedriver 'E:\Programme\ELAU\ENI-4 V1\Drivers\ENIDrvSourceSafe6.edd".

Possible cause of the error:The driver for the version management tool Visual SourceSafe 6.0cannot be selected in the tool ENI Config until SourceSafe 6.0 has beenproperly installed.

Fig. 5-1: Message

5.2 Notes on the Version Management Tools

5.2.1 PVCS Version Manager 7.5.1

If a label is generated, only the name of the label is saved in the versionmanagement tool. The label cannot be inscribed with a comment ordetermined by a user.

Labeling

Page 32: PD_OperaMa_ENI-4_en0410.pdf

Working with ENI-4

Page 32 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Page 33: PD_OperaMa_ENI-4_en0410.pdf

6.1 ENI Control

ELAU AG User Manual Page 33

PD_O

pera

Ma_

EN

I-4_e

n.do

c

6 Appendix

6.1 ENI Control

6.1.1 Starting ENI Control

NOTE

You can start the tool ENI Control even if the ENI-4 has not beenstarted.

How to start the tool ENI Control: Right or left click on the ENI symbol in the task bar.

Alternatively, open ENI Control via the Windows Start menu:

When you start the tool, you have to enter an administratorpassword.

Page 34: PD_OperaMa_ENI-4_en0410.pdf

Appendix

Page 34 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

NOTE

The tool is delivered without administrator password. In this case youcan simply confirm the dialog with OK without entering a password. Ifdesired, you can enter a password of your own; this will be used asadministrator password.

Then the main mask of the tool ENI Config is started.

Page 35: PD_OperaMa_ENI-4_en0410.pdf

6.1 ENI Control

ELAU AG User Manual Page 35

PD_O

pera

Ma_

EN

I-4_e

n.do

c

6.1.2 Starting ENI Admin

NOTE

The tool ENI Admin can only be started if the ENI-4 has been startedand is active. This can be seen from the colored ENI symbol in the taskbar (if the ENI-4 has not been started, the symbol is gray).

How to start the tool ENI Admin: Left or right click on the ENI symbol in the task bar

Alternatively, open ENI Admin via the Windows Start menu:

When you start the tool, you have to enter an administrator password.

NOTE

The tool is delivered without administrator password. In this case youcan simply confirm the dialog with OK without entering a password. Ifdesired, you can enter a password of your own; this will be used asadministrator password.

Page 36: PD_OperaMa_ENI-4_en0410.pdf

Appendix

Page 36 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

Then the main mask of the tool ENI Admin is started.

Page 37: PD_OperaMa_ENI-4_en0410.pdf

6.2 Contact Addresses

ELAU AG User Manual Page 37

PD_O

pera

Ma_

EN

I-4_e

n.do

c

6.2 Contact Addresses

For Repair

Please send components to be repaired or checked, along with the errorreport, to this address:

ELAU AGAbt. Kundendienst house address:Postfach 1255 Dillberg 1297821 Marktheidenfeld 97828 MarktheidenfeldTelephone: +49 (0) 93 91 / 606 - 142Fax: +49 (0) 93 91 / 606 – 340

Service teamShould you need to talk to a member of our service team or needservice at your site, please contact:

ELAU AGDillberg 1297828 MarktheidenfeldTel.: +49 (0) 93 91 / 606 - 0Fax: +49 (0) 93 91 / 606 - 300e-mail: [email protected]: www.elau.de

ELAU, Inc.ELAU Inc.165 E. Commerce DriveSchaumburg, IL 60173Phone: +1 847 490 4270Fax: +1 847 490 [email protected]://www.elau.com

ELAU SYSTEMS ITALIA S.r.l.Via Tosarelli 300I-40050 Villanova di Castenaso (BO)Tel.: +39 051 / 7818 70Fax: +39 051 / 7818 69e-mail: [email protected]: www.elau.it

NOTE

Further contact addresses are available on the ELAU homepage(www.elau.de).

Page 38: PD_OperaMa_ENI-4_en0410.pdf

Appendix

Page 38 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

6.3 Further Literaturee

The following manuals and instructions on the PacDrive™ system areavailable from ELAU:

Project ManualArt.No. 17 13 00 58 – 00x (DE, EN, FR)

Programming ManualArt.No. 17 13 00 61 – 00x (DE, EN)

Operating Manual PacDrive MC-4Art.No. 17 13 00 62 – 00x (DE, EN, IT, FR)

Operating Manual CAN L2Art.No. 17 13 00 66 – 00x (DE, EN)

Operating Manual PROFIBUS-DPArt.No. 17 13 00 67 – 00x (DE, EN)

Operating Manual SM-MotorArt.No. 17 13 00 68 – 00x (DE, EN, IT, FR)

Operating Manual EPAS-4Art.No. 17 13 00 70 – 00x (DE, EN)

Operating Manual MAx-4 PacDrive ControllerArt.No. 17 13 00 71 – 00x (DE, EN, IT, FR)

Operating Manual OPC-ServerArt.No. 17 13 00 73 – 00x (DE, EN)

Operating Manual Device NetArt.No. 17 13 00 76 – 00x (DE, EN)

Operating Manual HMI LibrariesArt.No. 17 13 00 77 – 00x (DE, EN)

Operating Manual INC-4 Incremental Encoder Module Art.No. 17 13 00 78 – 00x (DE, EN)

Operating Manual CANopenArt.No. 17 13 00 79 – 00x (DE, EN)

Operating Manual Motion Toolkit ECAM-4Art.No. 17 13 00 80 – 00x (DE, EN)

Operating Manual PN-4 PacNet ModuleArt.No. 17 13 00 81 – 00x (DE, EN)

Operating Manual SR-MotorArt.No. 17 13 00 82 – 00x (DE, EN)

1. Art. Nr. –000 DEutsch –001 ENglish –002 ITalian –003 FRench

Page 39: PD_OperaMa_ENI-4_en0410.pdf

6.3 Further Literature

ELAU AG User Manual Page 39

PD_O

pera

Ma_

EN

I-4_e

n.do

c

Operating Manual Bus Terminal BT-4/DIO1

Art.No. 17 13 00 83 – 00x (DE, EN)

Operating Manual TTS

Art.No. 17 13 00 88 – 00x (DE, EN*)

User Manual Automatic Controller Optimization

Art.No. 17 13 00 89 – 00x (DE, EN)

User Manual PacDrive SCL

Art.No. 17 13 00 93 – 00x (DE, EN)

User Manual PacDrive PS-4 und PacDrive PD-8

Art.No. 17 13 00 94 – 00x (DE, EN)

User Manual Evaluation Kit

Art.No. 17 13 00 95 – 00x (DE)

User Manual PacDrive Controller P600

Art.No. 17 13 00 96 – 00x (DE, EN, FR)

User Manual PacDrive Controller C200

Art.No. 17 13 00 97 – 00x (DE, EN, FR)

User Manual PacDrive Controller C400

Art.No. 17 13 00 98 – 00x (DE, EN, FR)

User Manual PacDrive Controller C600

Art.No. 17 13 00 99 – 00x (DE, EN, FR)

User Manual PacDrive ENI-4 Server

Art.No. 17 13 01 07 – 00x (DE, EN)

* = in preparation

Page 40: PD_OperaMa_ENI-4_en0410.pdf

Appendix

Page 40 User Manual ELAU AG

PD

_Ope

raM

a_E

NI-4

_en.

doc

6.4 Product Training

We offer a variety of training courses on our products.

Our seminar leaders, who have several years’ experience, will enableyou to make the best possible use of the vast possibilities of thePacDrive™ system.

NOTE

Please check the ELAU homepage (www.elau.de) for furtherinformation and our seminar program.

Page 41: PD_OperaMa_ENI-4_en0410.pdf

6.5 Index

ELAU AG User Manual Page 41

PD_O

pera

Ma_

EN

I-4_e

n.do

c

6.5 Index

AAdministrator Password 13

Ccontact addresses 37

EENI Admin 19ENI Control 18ENI password 14ENI user 14ENI-4 Server

install 10ENI-4 user, ENI-4 password 16

FFAQ 31File System Driver 14

IIMPRINT 2Installation 7

Llicense 23License Management 26Location of ss.exe 15

MMKS Source Integrity 14

NNew Data Base

PVCS create 8VSS 6.0 create 8

PProjects File 15PVCS 15PVCS Configuration File 16PVCS Dll Path 16

Rrepair 37Root project 14

Sservice team 37Source Safe 6.0 14srcsafe.ini 14system requirements 6

TTemporary folder 14, 16

UUpdate PVCS GUI 16

VVersion Management Tool 7