PDMS Model Color Codes _CP-00 Extract

25
1a.0 04-2012 Issued For Implementation. Rev. Date Description / Text Affected Codes Of Practices For Plant Design - Part-1: Documentation & Archiving ADMA-OPCO CP-00 Part-1 PAGE 51 SF / General / 002 Rev.0 sheet 1 of 1 4.7 Platform / Area nomenclature Guidelines: a. New platform or area which is similar to existing facilities should carry the same existing facility name by adding sequence number such as CSP, CSP-1 or NRP, NRP-1. b. New facilities with new operation concept should carry an abbreviated name agreed between project team and ESVT i.e. SARB, UL, GIF, GPF and TA …etc c. Area number for all new facilities will be assigned by Engineering Record officer. 5. AVEVA PDMS PDMS project folders, files, databases including any foreign project data, templates, reports and all relevant document/ information associated with the project shall be submitted to ADMA-OPCO. The PDMS environment shall be set-up in accordance with this document. 5.1 Project Set-up PDMS System administration of the Project set up shall be documented in detail and submitted for ADMA-OPCO approval prior to modeling. This shall include all team names, user names & passwords, administration passwords, MDB/ database names/ numbers with description, design hierarchy & naming convention with description. All UDA’s required for the project shall be documented and submitted for ADMA- OPCO approval. 5.2 Model Content The individual areas of the detailed 3D model shall be the responsibility of the respective engineering/design disciplines. Each discipline shall define and document the items that are to be modeled in PDMS in their respective areas. Any exclusion to the model content is subject to written approval by ADMA-OPCO. The following shall be modelled as a minimum. Structure: Primary and secondary and tertiary steelwork (Columns, Beams, Bracings…) Joints complete with details. Floor, grating, plating and walls including penetration & sleeves and fireproofing. Jacket appurtenances, boat landing, riser fender, J-tube, Caissons, anodes… Stairs, ladders, access/ maintenance platforms, walkways, handrails and kick plates.

description

pdms colour code

Transcript of PDMS Model Color Codes _CP-00 Extract

Page 1: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

51

SF / General / 002 Rev.0 sheet 1 of 1

4.7 Platform / Area nomenclature Guidelines:

a. New platform or area which is similar to existing facilities should carry the same

existing facility name by adding sequence number such as CSP, CSP-1 or NRP,

NRP-1.

b. New facilities with new operation concept should carry an abbreviated name

agreed between project team and ESVT i.e. SARB, UL, GIF, GPF and TA …etc

c. Area number for all new facilities will be assigned by Engineering Record officer.

5. AVEVA PDMS

PDMS project folders, files, databases including any foreign project data, templates, reports

and all relevant document/ information associated with the project shall be submitted to

ADMA-OPCO.

The PDMS environment shall be set-up in accordance with this document.

5.1 Project Set-up

PDMS System administration of the Project set up shall be documented in detail and

submitted for ADMA-OPCO approval prior to modeling.

This shall include all team names, user names & passwords, administration

passwords, MDB/ database names/ numbers with description, design hierarchy &

naming convention with description.

All UDA’s required for the project shall be documented and submitted for ADMA-

OPCO approval.

5.2 Model Content

The individual areas of the detailed 3D model shall be the responsibility of the

respective engineering/design disciplines. Each discipline shall define and document

the items that are to be modeled in PDMS in their respective areas.

Any exclusion to the model content is subject to written approval by ADMA-OPCO.

The following shall be modelled as a minimum.

• Structure: Primary and secondary and tertiary steelwork (Columns, Beams, Bracings…)

Joints complete with details.

Floor, grating, plating and walls including penetration & sleeves and

fireproofing.

Jacket appurtenances, boat landing, riser fender, J-tube, Caissons, anodes…

Stairs, ladders, access/ maintenance platforms, walkways, handrails and kick

plates.

Page 2: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

52

SF / General / 002 Rev.0 sheet 1 of 1

Structural supports and guides for equipment, piping, trays, ducts….

Equipment handling fixtures like crane, monorail, lifting hoist, pulley/ chain

block…

Installation aids i.e. lifting pad eyes/ trunnions….

• Equipment:

Process and Utility equipment (to shape) shown on P&ID/ Equipment list

including within package/ skid complete with appurtenances such as nozzles,

hand hole, manway, covers, and davits…

Major proprietary and ancillary items.

Saddles, supports and any fixing mechanism.

Door/ cover swing and access volume.

Installation/ handling volumes and aids i.e. lifting pad eyes/ lugs, slings...

Jacket/ insulation volume complete with aids like rings, cleats...

Reinforcement items, platform/ support cleats.

Reserved volume for withdrawal/ removal, operation/ maintenance/ access,

dropout zone, handling space etc…

Future equipment (Modelled in separate Zone).

• Piping:

All process, auxiliary and utility piping (including piping covered under

legend drawing), piping within package/ skid (including vendor scope).

Vessel trim, bridle complete with instrument.

Inline items, fittings, accessories, special items, valves & instruments

complete with manual/ gear/ actuated operators and space required for

operation.

Insulation, jacket as per specification.

Vent, drain, instrument tapping/ connection, utility station.

Pipe supports.

Reserved volume for operation/ maintenance, removal and handling/

retrieving tools.

Conductors/ risers.

Bolt removal envelop to ensure no captive bolts and space for torqueing/

tensioning equipment.

All future piping (Modelled in separate Zone).

• Electrical and Instrumentation:

All equipment e.g. generator, transformer, switchgear, MCC, LCS…

Accessories for valve actuators.

Cable trays/ ladders with support, J-Tube.

Page 3: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

53

SF / General / 002 Rev.0 sheet 1 of 1

Electrical/ instrument panels & cabinets complete with door swing,

maintenance/ access volume, stanchion….

Junction box, Marshalling box, Distribution box, termination box…

Lighting fixtures, power sockets, switches, Nav-aid…

Field instruments with support/ stanchion and shade.

Radio mast/ tower.

• HSE:

All equipment i.e. Firefighting, safety, Lifeboat/ raft with davit, life buoy…

Deluge/ Foam skid (with piping), deluge and sprinkler system with coverage

envelop.

Fire mains, fire hydrants/ monitors, hose reel..

Primary & secondary escape route/ volume with indicators/ signage and

muster area.

F&G detection, PA system, Telecom, CCTV, beacon, sounder…

Maintenance/ operation/ access volume, lay-down & material handling

volume, dropout zone, crane & lifting hoist movement area/ volume.

Hatches, access openings with protective barriers.

Safety shower, eyewash.

• HVAC:

All equipment e.g. Chiller, Air handling unit, Compressor unit, Window

AC…

All piping (i.e. chilled water, refrigeration) with inline items, accessories,

instruments, valves, actuators…

Ductwork with accessories, dampers, actuators, grilles..

Support for equipment, ductwork, piping.

Duct and pipe insulation.

Reserved space/ volume for maintenance, handling..

• Architectural and Civil:

Foundations for structure & support, sleepers, piles, etc ..

Building detailing doors and windows.

Page 4: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

54

SF / General / 002 Rev.0 sheet 1 of 1

5.3 Database and Naming

The project shall be split into Multiple Databases (MDB’s) based on Area for Das

Island and Platform for Offshore. Area number shall be MDB Name. e.g.:

Each discipline shall be allocated databases based on the PDMS activity.

Databases numbers shall be obtained from ADMA-OPCO. Database file number shall

be same as database number. Sequential numbers shall be used without skipping except

for temporary DB’s (which are to be deleted upon as built) which shall use end of the

range, to maintain continuity of the numbers.

Naming format of all administrative elements and databases with description to have

a suitable convention.

Details of the naming convention and coding explanations used to be submitted to

ADMA-OPCO for approval.

An example database name and description is given below for information only:

DB Name: 201+DES+PIPE+01 e.g. 201DESPIPE01

= Serial Number (Incremental for same DB name)

= Discipline Code

= Database Type Code

= Area number / MDB name

DB Description: Piping Design DB for ZWSC - Riser Platform

Database Type Code

Data Base Type Code Data Base Type Code

Design (DESI) DES Dictionary (DICT) DIC

Draft (PADD) DRA ISODRAFT (ISOD) ISO

Catalogue (CATA) CAT Schematic (SCHE) SCH

Properties (PROP) PRO Engineering (ENGI) ENG

MDB Name MDB Description

08.3 Das - Zakum Separator Area

201 ZWSC - Riser Platform

Page 5: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

55

SF / General / 002 Rev.0 sheet 1 of 1

Discipline Code

Discipline Description Codes

Structure (offshore topside)* Structural Discipline STRU

Structure (offshore Jacket)* Structural Discipline JCKT

Civil Civil CIVL

Architecture Architecture ARCH

Support Support SUPP

Equipment Mechanical Discipline EQUI

Piping Mechanical Discipline PIPE

Instrumentation Instrumentation Discipline INST

Electrical Electrical Discipline ELEC

HVAC HVAC HVAC

Safety HSE discipline HSE

General General Purpose GEN

Catalogue PDMS Administration Discipline CATA

* Discipline code STRU & JCKT for offshore and STRU for onshore shall be used.

5.4 Catalogues and Specifications Naming

All items shall be named in accordance with the catalogues component naming convention as

supplied with PDMS. There shall be project specific catalogue databases for components

and/or data items that are created for the project.

Catalogues and Specifications (e.g. Piping, Structural, etc.) shall be developed to ADMA-

OPCO standards and any deviations are to be noted and submitted to ADMA-OPCO for

approval.

5.5 PDMS Design Hierarchy

PDMS Design Sites and Zones shall be named (as illustrated below) in a manner such that

they can be easily identified and organised against plant area and discipline. Sites and Zones

shall have their description and purpose attributes set to reflect their intended use. Naming

format with description shall be submitted for ADMA-OPCO approval.

Page 6: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

56

SF / General / 002 Rev.0 sheet 1 of 1

• Site Naming

Sites shall be created and named in line with the respective DB for all disciplines with

the Datum Point and Purpose set for it. Site naming shall be in the following format:

Site Name: =XXXPIPE

Where PIPE =Discipline Code

XXX =Area number/ MDB name

e.g.: Site name for Piping in area 201 (ZWSC Riser Platform) shall be /201PIPE.

• Zone Naming

Zone naming will vary as per the discipline need. All zones created shall be named

appropriately and to follow the explained convention. For offshore Zone naming is

generally deck based and for Onshore it is based on type.

• Pipe Zone Naming

All pipes shall be modelled in proper zone which is based on process service code. The

zone name shall be as follows:

/201PIPE/NNNN e.g. /201PIPE/CO

Process Service Code

Site Name (Area Number/ MDB name +

Discipline Code) e.g.: Pipe having service code “CO” shall be created in zone /201PIPE/CO.

Detailed hierarchy as follows:

Site > /201PIPE

Zone> /201PIPE/CO

Zone> /201PIPE/LO

Zone> /201PIPE/PW > /CO-16”-AC0NA0-1234AD

> /CO-18”-AC0NA0-2345AD

> /CO-20”-AC0NA0-3456AD

• Equipment Zone Naming

All mechanical equipment (with proper origin) shall be modelled under equipment zone.

For offshore zones shall be deck based. Where equipment crosses into multiple decks it

shall be modelled under deck on which it rests. The zone naming shall be as follows:

For Onshore

08.3EQUI/NNNN e.g. /08.3EQUI/Static

Equipment type: Static/ Rotating

Site Name (Area Number/ MDB name +

Discipline Code)

Page 7: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

57

SF / General / 002 Rev.0 sheet 1 of 1

For Offshore

201EQUI/NNNN e.g. /201EQUI/Deck name

Deck name (where necessary)

Site Name (Area Number/ MDB name +

Discipline Code)

Future equipment shall be created in separate zone as follows:

/201EQUI/FUTURE e.g. /201EQUI/FUTURE

Site Name (Area Number/ MDB name + Discipline Code)

Detailed hierarchy as follows:

/201EQUI/DECK NAME For modelling Mechanical equipment.

/201EQUI/PACKAGE: For modelling Mechanical package unit.

Detailed Hierarchy as follows:

Site > /201EQUI

Zone> /201EQUI/MAINDECK

Zone> /201EQUI/PACKAGE

/EQUI> /201-C-1234

NOZZ> /201-C-1234/N1 /EQUI> /201-P-1234

NOZZ> /201-C-1234/N2 /EQUI> /201-T-1234

SUBE> /201-C-1234/Platform-Clips /EQUI> /201-V-1234

SUBE> /201-C-1234/Ladder-Clips

SUBE> /201-C-1234/Supp-Clips

SUBE> /201-C-1234/Earthing-Boss

SUBE> /201-C-1234/Name-Plate

SUBE> /201-C-1234/Fixed-Saddle

SUBE> /201-C-1234/Sliding-Saddle

SUBE> /201-C-1234/Davit-XXX (Each davit to be SUBE and named appropriately)

SUBE> /201-C-1234/Boot

SUBE> /201-C-1234/Rein-Pad

SUBE> /201-C-1234/Insulation

SUBE> /201-C-1234/Access-Way/ Platform

SUBE> /201-C-1234/Reserved-Volume

SUBE> /201-C-1234/Reserved-Volume: Area /volume required/ reserved for operation and

maintenance of the equipment.

• Nozzle Naming

Nozzle names shall be equipment tag/nozzle number. e.g. /201-C-1234/N1

Page 8: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

58

SF / General / 002 Rev.0 sheet 1 of 1

• Civil/Structure Zones:

Zone naming for Civil/ Structure for Offshore shall be deck based and as follows:

For Onshore Zone naming, sub division shown under deck shall be used (e.g.:

STRUCTURE, LAD-STAIR, HANDRAIL …).

/201STRU/HELI DECK

/201STRU/VALVE ACCESS DECK

/201STRU/MAIN DECK

/201STRU/CELLAR DECK

Detailed Hierarchy as follows:

Site > /201STRU Deck Code shall be used at /STRU> level and below

Zone> /201STRU/MAIN DECK /STRU>MDK/STRUCTURE For modelling main

structure.

/STRU>MDK/LAD-STAIR For modelling ladder &

staircase.

/STRU>MDK/HANDRAIL For modelling handrail.

/STRU>MDK/GRATING For modelling grating

/flooring.

/STRU>MDK/SUPPORT For modelling all

supports.

/FRMW>MDK/COLUMN

/FRMW>MDK/BEAM

/FRMW>MDK/BRACING

Access/ Maintenance platforms shall be created at /STRU> level and named appropriately.

All sections (SCTN) under framework shall be properly tagged.

Items like stiffeners shall be clubbed together and created under sub-framework and tagged

appropriately (as per the structure they belong to).

Deck Codes:

Deck/ Area Level Code Deck/ Area Level Code

Heli Deck HED Mezzanine Deck MZD

Above Weather Deck AWD Valve Access Deck VAD

Weather Deck WED Sub Cellar Deck SCD

Solar Panel Deck SPD Sump Deck SDK

Main Deck MDK Jacket Walkway and Boat Landing BLL

Cellar Deck CDK

Page 9: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

59

SF / General / 002 Rev.0 sheet 1 of 1

Similar convention shall be followed for Jacket.

• Electrical Zones

Zone naming for Electrical shall be as follows:

/201ELEC/CABLE_TRAY-HI: For modelling Electrical high voltage cable tray.

/201ELEC/CABLE_TRAY-LO: For modelling Electrical low voltage cable tray.

/201ELEC/EQUI-Deck Name: For modelling Electrical equipment (Transformer,

Panels, DB, Bus duct etc.) based on deck for

offshore and one zone for onshore.

/201ELEC/SMALL-POWER-EQUIP: For modelling Electrical lighting fixture & poles

etc.

/201ELEC/EHT-SYSTEM: For modelling Electrical heat tracing equipment.

Detailed Hierarchy as follows:

Site > /201ELEC

Zone> /201ELEC/CABLE_TRAY-HI

Zone> /201ELEC/CABLE_TRAY-LO

Zone> /201ELEC/EQUI-Deck Name /PIPE> CABLE_TRAY-HI-150

/PIPE> CABLE_TRAY-HI-200

/PIPE> CABLE_TRAY-HI-300

/PIPE> CABLE_TRAY-HI-400

/STRU> DBs

/STRU> RTU

/STRU> PANELS

/STRU> TRANSFORMER

/STRU> SWITCH-GEAR

All equipment shall be created with proper origin.

• Instrument Zones

Zone naming for Instrument shall be as follows:

/201INST/F&G: For modelling fire and gas detector.

/201INST/EQUI: For modelling instrument equipment.

/201INST/TEL-EQUIP: For modelling telecom equipment, CCTV, PA system.

/201INST/MANIFOLD: For modelling instrument air manifold.

/201INST/CABLE-TRAY: For modelling instrument cable tray.

/201INST/V-BOTTLE: For modelling Volume bottle.

Detailed Hierarchy as follows:

Site > /201INST

Zone> /201INST/CABLE-TRAY

Page 10: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

60

SF / General / 002 Rev.0 sheet 1 of 1

Zone> /201INST/EQUI

Zone> /201INST/CABLE-TRAY

Zone> /201INST/EQUI

/PIPE> CABLE_TRAY-150

/PIPE> CABLE_TRAY-200

/PIPE> CABLE_TRAY-300

/STRU> JBOX

/STRU> MBOX

/STRU> LOC-PANEL

/STRU> ANA-PANEL

/STRU> STANCHIONS

All equipment shall be created with proper origin.

• Safety Zones

Zone naming for HSE shall be as follows:

/201HSE/EQUI: For modelling firefighting & safety equipment.

/201HSE/ESCAPE-ROUTE: For modelling escape routes.

/201HSE/LAYDOWN: For modelling laydown area.

/201HSE/ACCESS: For modelling access and maintenance volume.

Detailed Hierarchy as follows:

Site > /201HSE

Zone> /201HSE/EQUI

/EQUI> Lifeboat-001(assigned tag shall be used)

/EQUI> Lifebouy-001

All equipment shall be created with proper origin.

• Support Zones:

/201SUPP/PIPE

/201SUPP/ELEC

/201SUPP/INST

/201SUPP/HVAC

Detailed Hierarchy as follows:

Site > /201SUPP

Zone> /201SUPP/PIPE /STRU>MDK/SUPP

/STRU>VAD/SUPP

/STRU>CDK/SUPP

Deck Code shall be used at /STRU> level and below for offshore.

Page 11: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

61

SF / General / 002 Rev.0 sheet 1 of 1

• Equipment Origin:

All equipment shall have a logical origin which can aid in its placement. Following are

examples of origin for some equipment.

Page 12: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

62

SF / General / 002 Rev.0 sheet 1 of 1

ISO VIEW

CENTRELINE & FLANGE FACE

OF LOWER RIGHT HAND NOZZLE

CL

PLAN

ELEVATION

CENTRELINE & FLANGE FACE

OF INLET NOZZLE

PLAN

PLAN

ELEVATION

CENTRELINE OF EQUIPMENT & BOTTOM TAN LINE

PLATE EXCHANGER

T/L

VERTICAL VESSEL/ COLUMN/ CYCLONE

ELEVATION

TAN LINE NEAR FIXED SUPPORT

CENTRELINE OF EQUIPMENT &

PLAN

CL

CONDENSERS

FIN-FAN COOLERS &HORIZONTAL VESSEL

F.S

S.S

T/L

SHELL & TUBE EXCHANGER

ELEVATION

& CENTRELINE OF TUBE INLET

CENTRELINE OF TUBE BUNDLE

ELEVATION

INLET/ OUTLET NOZZLES

CENTRELINE OF EXCHANGER &

REBOILER

Page 13: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

63

SF / General / 002 Rev.0 sheet 1 of 1

& DISCHARGE NOZZLE

CENTRELINE OF PUMP

ELEVATION

PLAN

CL

EQUIPMENT & DRIVER

& FAN, HORZ. ROTARY

HORIZONTAL PUMP, BLOWER

DIS

CH

.

ELEVATION

& DISCHARGE NOZZLE

CENTRELINE OF PUMP

VERTICAL PUMP

OF SUCTION FLANGE

CENTRELINE & FACE

ISO VIEW

PLAN

DISPLACEMENT PUMP

POSITIVE

ISO VIEW

PLAN

SKID/PACKAGE

SOUTH WEST CORNER

BOTTOM OF BASE AT

ELEVATION

& TUBE INLET

CENTRELINE OF EQUIPMENT

EXCHANGER

PRINTED CIRCUIT

OF BASE AT SOUTH OR WEST END

CENTRELINE OF EQUIPMENT & BOTTOM

ELEVATION

PLAN

COMPRESSOR PACKAGE

EL

Page 14: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

64

SF / General / 002 Rev.0 sheet 1 of 1

SOUTH WEST CORNER

BOTTOM OF BASE AT

ISO VIEW

PLAN

TANK OR VESSEL

RECTANGULAR STORAGE

ISO VIEW

CENTRELINE OF PUMP

& DISCHARGE NOZZLE

MOTOR

PUMP

VERTICAL SUBMERGED

PUMP

LIFEBOAT & DAVIT

& INLET NOZZLE

CENTRELINE OF EQUIPMENT

ISO VIEW

PLAN

FILTER/ STRAINER

FACE OF FLANGE

CENTRELINE AT FACE OF

ISO VIEW

PLAN

PIG LAUNCHER

& RECEIVER

ISO VIEW

BASE OF PEDESTAL

CRANE

ISO VIEW

SUPPORTS & TOP OF STEEL

MID WAY BETWEEN

BOTTOM OF BASE PLATE

CENTRELINE &

STORAGE TANK

For E&I Cabinets/ Panels - Centre bottom of back side/ panel.

Page 15: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

65

SF / General / 002 Rev.0 sheet 1 of 1

5.6 Tagged Items

All tagged items shall be named as per their Tag ID as given on P&IDs, plot-plans,

datasheets, lists, etc. and as per specified tagging philosophy. Any deviations shall be

documented and submitted to ADMA-OPCO for approval. This applies to but is not limited

to:

a. Equipment

b. Nozzles

c. Pipes

d. In-line piping items, i.e. Orifice Plates, Instruments, Valves, Filters, etc.

e. Steelwork i.e. columns, beams, stair, ladder, access platform etc.

f. Electrical & Instrument Cable Tray, Equipment, i.e. Junction Boxes, Control Panels,

etc.

g. Supports

5.7 Pipe Supports

AVEVA Multi-Discipline Supports (MDS) software shall be used for the 3D design of all

Pipe work supports in PDMS.

The catalogue, specification, design and drawing databases for VPD-MDS that are used on

the project complete with any modifications shall be submitted to ADMA-OPCO as part of

the project deliverable.

Support numbering shall comply with ADMA-OPCO numbering procedure.

E.g. 201-PS-00001

= Sequence Number

= Pipe Support

= Area number/ MDB name

PS = Pipe Support

TS = Cable Tray Support

SPS = Special Support

5.8 Colours

Colours specified in the following table which is basic identification colour (first band

colour) specified in ADMA-OPCO painting manual MNL-01 shall be used for PDMS model,

draft and review model.

Page 16: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

66

SF / General / 002 Rev.0 sheet 1 of 1

1.0 - STRUCTURE

SL.

No

.

3D Model Item ADMA Basic Colour

PDMS

Colour

Name

PDMS

DRAFT

Colour

Auto

Cad

Colour

PDMS

Review

Colour

1.1 STRUCTURE - JACKET BLACK 15 0

1.2 STRUCTURE - DECK

IVORY 185 255,255,

240

1.3 STEEL GRATING BLACK 15 8

1.4 GRP - GRATING

YELLOW 31 2

1.6 PLATING

LIGHT

GREY 1 9

2.0 – MECHANICAL

2.1 EQUIPMENT - NEW CYAN 56 4

2.3 EQUIPMENT (FUTURE)

PIPING (FUTURE) STEEL BLUE 67 165

2.3 HANDLING EQUIPMENT,

WAYS/VOLUMES DARKSLATE 46 117

Page 17: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

67

SF / General / 002 Rev.0 sheet 1 of 1

3.0 – ELECTRICAL

SL.

No. 3D Model Item ADMA Basic Colour

PDMS

Colour

Name

PDMS

DRAFT

Colour

Auto

Cad

Colour

PDMS

Review

Colour

3.1 ELECTRICAL HIGH

VOLTAGE CABLE TRAYS RED 11 1

3.2 LOW VOLTAGE CABLE

TRAY MAGENTA 71 6

3.3 ELECTRICAL EQUIPMENT

(CONTROL PANELS) LIGHT

GREY 1 9

4.0 – INSTRUMENTATION

4.1 INSTRUMENTATION TRAY

/ LADDER ORANGE 140 30

4.2 INSTRUMENT EQUIPMENT

(CONTROL PANELS) LIGHT

GREY 1 9

5.0 – HSE

5.1 SAFETY PATH

AND

YELLOW WITH BLACK DIRECTIONAL

ARROWS AT 5 METER INTERVALS & AT

CHANGE OF DIRECTION.

5.2 FIRST AID EQUIPMENT

DARKSLATE 167 127

5.3 SAFETY NET SUPPORTS

RED 11 1

5.4 FIRE FIGHTING FACILITIES

RED 11 1

Page 18: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

68

SF / General / 002 Rev.0 sheet 1 of 1

6.0 – PIPING

SL.

No. 3D Model Item ADMA Basic Colour

PDMS

Colour

Name

PDMS

DRAFT

Colour

Auto

Cad

Colour

PDMS

Review

Colour

6.1 CRUDE OIL (LIVE) BROWN 9 26

6.2 CRUDE OIL (STABILIZED) BROWN 9 26

6.3 CRUDE OIL (EXPORT) BROWN 9 26

6.4 SEPARATED OIL BROWN 9 26

6.5 RECOVERED OIL BROWN 9 26

6.6 SOUR GAS (WET) SALMON 322 21

6.7 SOUR GAS (DRY) SALMON 322 21

6.8 SWEET GAS (WET)

< 100 PPM H2S SALMON 322 21

6.9 SWEET GAS (DRY)

< 100 PPM H2S SALMON 322 21

6.10 FLARE GAS SALMON 322 21

6.11 CONDENSATE SALMON 322 21

6.12 GAS CONDENSATE SALMON 322 21

6.13 FUEL GAS SALMON 322 21

6.14 RELIEF VENT

SPRING

GREEN 127 110

6.15 PROPANE SALMON 322 21

6.16 PILOT GAS TO FLARE SALMON 322 21

6.17 REBOILER VENT GAS SALMON 322 21

6.18 GAS TO ATMOSPHERE SALMON 322 21

6.19 HALON STEEL BLUE 160 142

6.20 INERGEN STEEL BLUE 160 142

6.21 VACUUM STEEL BLUE 160 142

6.22 NITROGEN STEEL BLUE 160 142

6.23 OXYGEN STEEL BLUE 160 142

6.24 INSTRUMENT AIR STEEL BLUE 160 142

6.25 INDUSTRIAL AIR STEEL BLUE 160 142

6.26 CHLORINE GAS STEEL BLUE 160 142

6.27 CARBON DIOXIDE STEEL BLUE 160 142

6.28 FIRE WATER RED 11 1

6.29 FOAM (FIRE FIGHTING) RED 11 1

Page 19: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

69

SF / General / 002 Rev.0 sheet 1 of 1

SL.

No. 3D Model Item ADMA Basic Colour

PDMS

Colour Name

PDMS

DRAFT

Colour

Auto

Cad

Colour

PDMS

Review

Colour

6.30 ACID MAUVE 12 204

6.31 CAUSTIC SODA MAUVE 12 204

6.32 STEAM

LIGHT GREY 1 9

6.33 STEM CONDENSATE

LIGHT GREY 1 9

6.34 BUNKER FUEL BLACK 15 0

6.35 AVIATION FUEL BLACK 15 0

6.36 FURNACE FUEL BLACK 15 0

6.37 KEROSINE BLACK 15 0

6.38 GASOLINE BLACK 15 0

6.39 DEISEL OIL BLACK 15 0

6.40 LUBE OIL BLACK 15 0

6.41 HYDRAULIC OIL BLACK 15 0

6.42 SEA WATER

FOREST GREEN 101 84

6.43 HOT WATER

FOREST GREEN 101 84

6.44 SOUR WATER

FOREST GREEN 101 84

6.45 COOLING WATER

FOREST GREEN 101 84

6.46 UTILITY WATER

FOREST GREEN 101 84

6.47 POTABLE WATER

FOREST GREEN 101 84

6.48 BALLAST WATER

FOREST GREEN 101 84

6.49 INJECTION SEA WATER

FOREST GREEN 101 84

6.50 BOILER FEED WATER

FOREST GREEN 101 84

6.51 EFFLUENT WATER

FOREST GREEN 101 84

6.52 DEOXYGENATED SEA

WATER FOREST GREEN 101 84

Page 20: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

70

SF / General / 002 Rev.0 sheet 1 of 1

5.9 Draft Drawings Rules, Libraries, etc

All 2D Drawing Production Administration elements, e.g. Rules, Libraries,

Templates, etc. shall be named and documented accordingly and submitted to

ADMA-OPCO for approval.

5.10 Draft Drawing Databases Structure

Drawing databases shall be created in a structured manner to reflect the design areas

and disciplines, consideration given to maximize drawing production.

Drawings and Sheets shall be named/ numbered in accordance with ADMA-OPCO

document/ drawing numbering procedure.

All dimensioning & annotation shall be done in draft and shall be intelligent. The

extent of annotation and quality of the drawing shall be as specified in CP-00 Part-3.

Modifying/ editing drawings outside PDMS shall not be accepted. Zone based layers shall be created and all items within the zone shall be placed in the

same layer. The 2D drawing representation within PDMS shall adhere to ADMA-OPCO

standards and be subject to ADMA-OPCO approval.

All drawings shall be fully updated to reflect the as-built 3D plant model upon

completion of the project and prior to hand over.

DWG and DXF format copy of all 2D project drawings produced within PDMS to be

provided to ADMA-OPCO.

• Draft Naming Convention Drawing Type Code

Drawing Type Drawing Type Code Section Discipline*

Plot Plan DWG L

General Arrangement Drawings GAD M

Section & Elevation Drawings DWG M

Miscellaneous Drawings MIS

* Refer section discipline above

Page 21: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

71

SF / General / 002 Rev.0 sheet 1 of 1

• Department Naming

Department Name = Discipline Code + Area Code + Platform Deck Code*

Example:-

• Registry Naming

Registry Name = Discipline Code + Area Code + Platform Deck Code* + Drawing Type Code

Example:-

Discipline

Code

Area

Code

Platform Deck

Code*

Drawing

Type Code Registry Name

PIPE XXX MDK (Main

Deck) GAD

/PIPEXXX-MDK-

GAD

* Platform Deck Code applicable to offshore only. For onshore use Elevations/ platform levels

where required.

• Sheet Naming

Example:-

Project

Code

Area

Code

Section /

Discipline Type

Drawing

Number

ADXXX XXX M 20010

5.11 Draft Text and Colours

• Text font, sizes & colour

The text font (with width factor 0.85), size and colour specified in the table below shall be

used for all engineering drawings and shall be in uppercase only. Exception to this shall be

ADMA Border template where provided fonts and colours shall be retained. Prior approval

shall be obtained for any deviation.

Discipline Code Area Code Platform Deck Code* Department Name

PIPE XXX MDK (Main Deck) /PIPEXXX-MDK

Page 22: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

72

SF / General / 002 Rev.0 sheet 1 of 1

Drawing Item

Drawing Size

A0 A1 A2 A3 A4

General

Text

Text Height 3 mm 3 / 2.5 mm 2.5 mm 2 mm 2 mm

Text Font Romans Romans Romans Romans Romans

Text Colour White White White White White

Headings

Text Height 5 mm 5 mm 4 mm 3.5 mm 3.5 mm

Text Font Romand Romand Romand Romand Romand

Text Colour White White White White White

Dimension Line Red Red Red Red Red

Projection Line Red Red Red Red Red

Leader Line Red Red Red Red Red

LABEL frame Red Red Red Red Red

Note line White White White White White

• Drawing items colour coding and line thickness

Drawing Type Drawing item

Pipes Structure Equipment Cable tray Other discipline

Piping Drawing

Refer colour

table Grey

Refer colour

table Grey Grey

Thick lines

Thin line Thin line Thin line Thin line

Equipment Drawing Grey Grey

Refer colour

table Grey Grey

Thin line Thin line Thick line Thin line Thin line

Structural Drawing Grey Magenta Grey Grey Grey

Thin line Thick line Thin line Thin line Thin line

Cable Tray Layout Grey Grey Grey Refer colour

table Grey

5.12 Piping Isometric Production and Control

Only complete lines with acceptable clash and data consistency to be submitted for isometric

generation.

Isometric option file(s) shall be created per MDB (Platform/ Plant/ Area) and shall be

configured to reflect ADMA-OPCO standards.

All process information/ parameters, test, heat treatment & painting requirement,

insulation/tracing type & thickness, support location/ type with tag, reference to piping GA &

P&ID, stress analysis requirement/ reference and detailing where required shall be provided

in isometric along with BOM.

Isometric drawing number shall reflect tag given in the design hierarchy which is the line tag

as specified in `CP-00 Part-2 process and utility line tagging format’.

Page 23: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

73

SF / General / 002 Rev.0 sheet 1 of 1

As-Built Isometrics in DXF and PDF format to be delivered to ADMA-OPCO

Please Note: Annotation/ editing of Isometrics outside of PDMS is not permitted unless

approved in advance by ADMA-OPCO.

5.13 Reports

All reports and PDMS report templates generated for and used on the project shall be

submitted to ADMA-OPCO. Reports shall be in MS Excel format.

5.14 Data Consistency Checking (Reports)

A final report showing all Pipes to be free of inconsistent data shall be delivered upon project

completion.

A final report showing all Structural items logically connected shall be delivered upon

project completion.

5.15 Clash Checking (Reports)

A final report showing clash free design and approved clashes shall be delivered upon project

completion.

5.16 Database Integrity (Dice Checking Report)

A final report showing all databases clean of errors shall be delivered upon completion of the

project.

5.17 Miscellaneous

All PDMS database sessions shall be merged prior to submission.

5.18 Project Data

ADMA-OPCO may at any time request complete PDMS Project Data and/ or access to

PDMS Project Data during Project execution.

5.19 Project Review

For periodic/ milestone and as-built review of the 3D PDMS model, latest colour review

model with status file of the 3D PDMS model shall be provided.

Review model (RVM & RVS) shall be made available to ADMA prior to periodic/ milestone

reviews.

Colours specified in the table shall be used for review model.

Page 24: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

74

SF / General / 002 Rev.0 sheet 1 of 1

5.20 Aveva P&ID

The As-built AVEVA P&ID drawings along with all related database and project files shall

be submitted to ADMA-OPCO upon project completion

P&ID representation shall be in accordance with ADMA-OPCO standards.

Symbols created for the project shall have a suitable naming convention and shall be

submitted to ADMA for approval.

Information detailing layer, line type, text font/ height, colour etc... for P&ID and PFD shall

be submitted to ADMA for approval.

5.21 Milestone Requirements

At project milestones the following shall be delivered to ADMA-OPCO;

a. P&IDs with .MON files

b. P&ID Reports generated reports

5.22 Project Completion

Upon project completion the following shall be delivered to ADMA-OPCO;

a. Project Set up & configuration

b. Project Symbols

c. Drawing Border Templates

d. P&IDs with .MON files

e. P&ID Reports MS Access database

f. P&ID Reports generated reports

g. Documented list of settings made to configure the VPE P&ID project.

6. END OF PROJECT DELIVERABLES:

At the end of the project, ADMA-OPCO’s, Engineering Services Team shall receive the

following deliverables from the Contractor/Consultant through ADMA-OPCO’s Project

Team Leader:-

6.1 One complete set of following Documents and Dossiers:

a. Main index of project completion dossiers/drawings (Deliverable List)

b. Engineering dossier consisting of all Specification, Calculation, Analysis, Data

sheets in its Native format

c. Certification Dossier

Page 25: PDMS Model Color Codes _CP-00 Extract

1a.0 04-2012 Issued For Implementation.

Rev. Date Description / Text Affected

Codes Of Practices For Plant Design - Part-1: Documentation & Archiving

ADMA-OPCO CP-00 Part-1 PAGE

75

SF / General / 002 Rev.0 sheet 1 of 1

6.2 As-Built drawing folder in native files as applicable

6.3 Drawing List

6.4 Process:

a. PFD’s

b. P & ID’s

6.5 Mechanical

a. Plot Plans

b. Piping General Arrangement

c. Vendor/ package GA’s (separate drawing for each package)

d. Sections & Details

e. Piping Isometric with BOM

f. Equipment Drawings (separate drawing for each equipment)

g. Line List

h. Valve List

i. Equipment List

j. MTO

k. Equipment and Valve Data Sheet (separate data sheet for each equipment and actuated/

safety valve).

6.6 Pipelines Drawing:

a. Profile & Alignment Sheets

b. Riser Details

6.7 Civil/Structural Drawing:

a. Site Layout, Plot Plan

b. General Arrangement

c. Architectural Drawings

d. Reinforced Concrete Detail