Access Control PAC Overview - Stanley Security …stanleypac.com/Products/Resource...

2
Access Control | 512 Two-Door Controller Series Overview The PAC 512 and the PAC 512IP control all aspects of two secure doors, with up to two card readers installed as entry and exit readers on each door. This includes support for a door strike to lock and unlock the door and a door contact to detect the doors position. Each door also has a programmable auxiliary input that may be used for alarm system integration, and an auxiliary output that enables a buzzer or strobe when security is breached or a door is left open. A tamper input enables the monitoring of a enclosure door, and an override input that will release both doors. In the event of communication loss, the PAC 512 allows all local functionality to continue until the server connection is restored. With unprecedented scalability and flexibility, a Stanley PAC access control system can consist of just PAC 512-series access controllers, or PAC 512s managed by an Access and Alarm Server (PAC 500). When operating in conjunction with a PAC 500, the PAC 512 serves as part of an integrated solution that can include both input (PAC 520) and output (PAC 530) controllers, elevator control and sophisticated anti-passback capabilities providing a scalable solution for even the largest applications. The Readykey Controller Retrofit Kit enables the conversion of existing K2100/K2200 controllers installed since 1990, to the new PAC 512 series. Utilizing the existing enclosure and power supply, the kit replaces the legacy controller with new PAC512s. The kit preserves all the existing infrastructure investment and maximizes the value of existing equipment by maintaining the power supply, cabling, readers and without re-enrolling cardholders. Key Features Controls up to two doors Each door supports up to two K2000 Series/K3000-Series/Oneprox TM readers for entry and exit or one Wiegand reader Up to 20,000 onboard cardholder database and 16,000 event buffer 75,000 dynamic cardholder management support in conjunction PAC 500 20 system holidays with 20 start and stop dates and times 200 time profiles with up to 4,000 weekly periods 5,000 access groups, each with 2 time profiles and 2 area lists One Form-C 3-Amp lock relay lock control per door One programmable supervised or non-supervised Form-C 5-Amp auxillary relay per door * One programmable supervised or non-supervised ancillary input per door * Dedicated case tamper and door override to open all doors Request to exit programmable supervised or non-supervised input per door Door contact programmable supervised or non-supervised input per door 5V and 12V reader data PAC 512IP includes a built-in RJ-45 100Mbps Ethernet connection Local anti-passback Area anti-passback and area usage in conjunction with PAC 500 Mantrap capability in conjunction with PAC 500 One-Touch TM installation test mode. This installer test facility enables the functionality of each controller and its associated circuits to be tested locally at the door, by simply pressing a single button without the need for a PC or programming AC and battery status are monitored and reported Non-volatile memory storage Rechargeable lithium battery monitoring and status reporting Lock sharing across door channels Individual extended door access times (ADA compliance) Downloadable firmware updates DIN-Rail mounting for ease of installation (removable) * Can be independantly controlled in conjunction with PAC 500 Access & Alarm Server 7S-512IPB

Transcript of Access Control PAC Overview - Stanley Security …stanleypac.com/Products/Resource...

Page 1: Access Control PAC Overview - Stanley Security …stanleypac.com/Products/Resource Library/Controllers/PAC 512 Two...READYKEY ™ COMPATIBLE Visit us at... AND OPTIONS 7S-512 Access

Access Control | 512 Two-Door Controller Series

Overview

The PAC 512 and the PAC 512IP control all aspects of two secure doors, with up to two card readers installed as entry and exit readers on each door. This includessupport for a door strike to lock and unlock the door and a door contact to detect the doors position. Each door also has a programmable auxiliary input that may beused for alarm system integration, and an auxiliary output that enables a buzzer or strobe when security is breached or a door is left open. A tamper input enables themonitoring of a enclosure door, and an override input that will release both doors. In the event of communication loss, the PAC 512 allows all local functionality tocontinue until the server connection is restored.

With unprecedented scalability and flexibility, a Stanley PAC access control system can consist of just PAC 512-series access controllers, or PAC 512s managed by anAccess and Alarm Server (PAC 500). When operating in conjunction with a PAC 500, the PAC 512 serves as part of an integrated solution that can include both input(PAC 520) and output (PAC 530) controllers, elevator control and sophisticated anti-passback capabilities providing a scalable solution for even the largest applications.

The Readykey™ Controller Retrofit Kit enables the conversion of existing K2100/K2200 controllers installed since 1990, to the new PAC 512 series.Utilizing the existing enclosure and power supply, the kit replaces the legacy controller with new PAC512s. The kit preserves all the existing infrastructure investmentand maximizes the value of existing equipment by maintaining the power supply, cabling, readers and without re-enrolling cardholders.

Key Features

Controls up to two doors

Each door supports up to two K2000 Series/K3000-Series/Oneprox TM readers for entry and exit or one Wiegand reader

Up to 20,000 onboard cardholder database and 16,000 event buffer

75,000 dynamic cardholder management support in conjunction PAC 500

20 system holidays with 20 start and stop dates and times

200 time profiles with up to 4,000 weekly periods

5,000 access groups, each with 2 time profiles and 2 area lists

One Form-C 3-Amp lock relay lock control per door

One programmable supervised or non-supervised Form-C 5-Amp auxillary relay per door*

One programmable supervised or non-supervised ancillary input per door*

Dedicated case tamper and door override to open all doors

Request to exit programmable supervised or non-supervised input per door

Door contact programmable supervised or non-supervised input per door

5V and 12V reader data

PAC 512IP includes a built-in RJ-45 100Mbps Ethernet connection

Local anti-passback

Area anti-passback and area usage in conjunction with PAC 500

Mantrap capability in conjunction with PAC 500

One-TouchTM installation test mode. This installer test facility enables the functionalityof each controller and its associated circuits to be tested locally at the door, by simplypressing a single button without the need for a PC or programming

AC and battery status are monitored and reported

Non-volatile memory storage

Rechargeable lithium battery monitoring and status reporting

Lock sharing across door channels

Individual extended door access times (ADA compliance)

Downloadable firmware updates

DIN-Rail mounting for ease of installation (removable)

*Can be independantly controlled in conjunction with PAC 500 Access & Alarm Server

7S-512IPB

Page 2: Access Control PAC Overview - Stanley Security …stanleypac.com/Products/Resource Library/Controllers/PAC 512 Two...READYKEY ™ COMPATIBLE Visit us at... AND OPTIONS 7S-512 Access

Visit us at...www.stanleypac.com

READYKEY™

COMPATIBLE

Visit us at...© 2018 Stanley Security Solutions, Inc. All Rights Reserved. All trademarks are the property of their respective owners.512 2018/1

CONTROLLER AND OPTIONS

7S-512 Stanley PAC 512 - Two Door Access Controller (DIN-Rail Mount)7S-512B STANLEY PAC 512 - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock ,

prewired with a single output 3A power supply/charger,12 or 24VDC selectable.

7S-512IP Stanley PAC 512IP - Two Door Access Controller (DIN-Rail Mount)7S-512IPB Stanley PAC 512IP - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock ,

prewired with a single output 3A power supply/charger,12 or 24VDC selectable.

7S-2KRETRO Readykey K2100/K2200 Controller Retrofit Kit

7S-PSU3 Stanley 3A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)7S-PSU7 Stanley 7A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)

SPECIFICATIONS

Primary Power The PAC 512 is for use in low voltage, power limited, class 2 circuits onlyInput Power: 10.5VDC to 28VDC — PAC 512IP 220mA maximum, PAC 512 220mA maximum

Event Memory and Clock Backup 3V Rechargeable Lithium Cell (Monitored and status reported) - 6 months memory retention when not poweredCommunication Ports

Ethernet (PAC 512IP only): 10/100Base-T Ethernet high-speed RJ-45 portDial-Up (PAC 512 only): RS-232Downstream Ports: RS-485, 32 local devices maximum

InputsTamper and Door Override: Programmable as supervised or unsupervised circuits, dedicatedPower Fail Monitors (MSTAT): Unsupervised, dedicated

Door Configuration Each door supports up to two K2000 Series/K3000-Series/Oneprox TM readers for entry and exit or one Wiegand reader Inputs Per Door

Door Contact, REX & Auxiliary Input: Each programmable as normally open,or normally closed, supervised or unsupervised circuitsOutputs Per Door

Relay outputs: One Form-C 3 A at 30VDC relay for lock control with thermal fuse and one programmable Form-C 5 A at 30VDC auxiliary relayReader Power Follows input voltage. Limited to 200 mA @ 12 VDCReader Port Compatibility PAC, Wiegand Data 1/Data 0 and Magstripe Clock/DataStatus LEDs RS-232, RS-485, Door 1, Door 2, LAN Status and System StatusWiring Requirements RS-485: CAT5 or CAT 6 up to 3000ft or 22AWG cable up to 500ft total cable.

Reader Wire: 22AWG Unshielded and Stranded, up to 800 ftMechanical

DIN-Rail Unit Dimensions: H: 7.3" W: 5.1" D: 5.1"DIN-Rail Unit Weight: 14oz. nominalEnclosure Dimensions: H: 13" W: 13" D: 3.5"

EnvironmentalTemperature: Operating: 14F to 130°F Storage: 9F to 176F Humidity: 0 to 90% RHNC

Approvals: UL 294-listed, CE-marked and ROHS compliantWarranty 5-Year Limited Warranty

REQUEST-TO-EXIT

+-12 OR 24V BATTERY INPUT

INPUT: 10.5VDC TO 28VDCDOOR LOCK

DOOR CONTACT

DOOR LOCK

DOOR CONTACT

EXIT (OUT) READEROR REX BUTTON

AUXILLARY OUTPUT(1 PER DOOR CHANNEL)

AUXILLARY INPUT(1 PER DOOR CHANNEL)

ENTRY (IN) READERENTRY READER

DOOR ONE DOOR TWO

UPSTREAM COMMUNICATIONS:RS-232 (PAC 512), TCP/IP (PAC 512IP)

or RS-485 (PAC 500)

DOWNSTREAM COMMUNICATIONS:TOTAL OF 24 CONTROLLERS

DOOR OVERRIDE

INPUTCASETAMPERINPUT

GROUND

PSU

-+ LOCK POWER OUTPUT

STANLEY PAC 512IP

1 2 3

* 0 #

7 8 9

4 5 6

ENTRYEXIT ENTRY EXIT

PAC

512

IP M

k. II