    CAST LABORATORIES PTE LTD

    53 TAMPINES INDUSTRIAL AVENUE 5 SINGAPORE 528636

    Business Reg No

    CONCRETE CUBE TEST REPORT

    THE PINES HOTEL @ STEVENS ROAD

    EVAN LIM & CO PTE LTD

    Project:

    Grade of Concrete:

    198100052N

    DATE: 21/04/2015

    TEST METHOD: Density

    Tel: 6260 6190 Fax: 6260 4257

    Website: www.castlab.com.sg

    SS78 Part A16:1987

    CUBE DETAILS AS FURNISHED BY COMPANY: JOB NO: E07/93/65

    Cement/Admixture (If Any):

    Supplier:

    PBFC

    Compressive Strength

      - (- )

    Structural Element Cast: PC-78

    PAGE: 1 OF 1

    SS78 Part A14:1987 (by calculation volume method)

    40

    SAMPLE MARK

    GIVEN

    SLUMP

    (mm)

    DIMENSION

    (mm)

    DENSITY

    AS RECEIVED

    (Kg/m3)

    MAX

    LOAD

    (kN)

    COMP

    STRENGTH

    (N/mm2)REMARKS

    PC-022-1 125 150x150x150 2400 865.8 38.5

    PC-022-2 125 150x150x150 2390 827.2 37.0

    DATE RECEIVED: DATE CAST: DATE TEST: AGE AT TEST: DAY(S)11/04/2015 18/04/2015 715/04/2015

    CAST Laboratories Pte LtdThis Report is issued under the following conditions:

    WITNESSED BY:

    1. This is a Test Report and not a CAST Laboratories Certificate of Quality. It

    only applies to the sample of the specific product given at the time of its

    testing.

    2. CAST Laboratories testing does not constitute a recommendation for or

    endorsement of, the product or material tested.

    3. The report shall not be reproduced in part or full unless approval in writing

    has been given by CAST Laboratories.

    4. CAST Laboratories agrees to use reasonable diligence in the manner of

    performing the test but no warranties are given and none shall be implied

    directly or indirectly relating to CAST Laboratories services, test results or

    facilities. In no event shall CAST Laboratories be liable for collateral, special or

    consequential damage.

    *Measured dimension (> ±1% of nominal)

    C.C.

    TESTED BY:ORIGINAL Raj

    HAMIDON BIN MOSTAFFAR

    ENGINEER

    The results reported herein have been performed in accordance with the laboratory's terms of accreditation under the Singapore Accreditation Council - Singapore Laboratory Accreditation Scheme/ 

    The report shall not be reproduced wholly or in parts unless approval in writing has been given by CAST Laboratories Pte Ltd.