PARALLEL PROCESSING UPS E33A - Sanyo · B i-d rec to nal v Ba ttery Filter Device Inv er Batte ry...

8
E33A PARALLEL PROCESSING UPS

Transcript of PARALLEL PROCESSING UPS E33A - Sanyo · B i-d rec to nal v Ba ttery Filter Device Inv er Batte ry...

E33APARALLEL PROCESSING UPS

2

min

min min min min

minmin

StandardStandard

Battery backup time

Extended battery

Internal Battery

Double conversion UPS

1,768,926kWh 1,621,945kWh(kWh)

5 8

PARALLEL PROCESSING UPS

100kVA(90kW)

200kVA(180kW)

300kVA(270kW)

AC380, 400, 415, 420V3 phase 3 wires / 3 phase 4 wires

Output

AC380, 400, 415, 420V3 phase 3 wires / 3 phase 4 wires

100kVA(90kW)

Output capacity

200kVA(180kW)

Input

AC380, 400, 415, 420V3 phase 3 wires / 3 phase 4 wires

Output

AC380, 400, 415, 420V3 phase 3 wires / 3 phase 4 wires

■ Power consumption comparison for one year

Input Output capacity

Supportingnetwork

Supportingnetwork

High efficiency1■ Achieves 98 % efficiency. Running costs can be drastically reduced.

■ Contribute on protecting the environment.

Parallel operation

Parallel redundant operation

Low energy, high quality, high reliability parallel processing type UPS

E33A

Conversion efficiency

Supplies power in sine wave and completely without interruption of output even when there is a power outage, such as black out instantaneous power break or voltage dip.When a surge generates by injection of a static capacitor, etc., the power feeding is switched to temporally mode which supplies power from the inverter.This power supply is not from battery, so stress is not placed on the battery.

High quality2

■ No interruption of output power

Facility equipment・Data center equipment・Factory equipment・Power plant, etc.0

500,000

1,000,000

1,500,000

2,000,000

*When power is supplied based on rated power.*Includes power consumption of facility equipment and

air conditioning system used for UPS cooling.

98%

Commercialpower

Waveform during power outage Waveform during surge addition

Commercial powerOperational status

Normal NormalCommercial and inverter parallel

operation

Commercial and inverter parallel

operation

NormalCommercial and inverter parallel

operation

Inverter power supply

(battery power supply)

Power outage

Input voltage

Output voltage

Commercial powerOperational status

Input voltage

Output voltage

During surge addition

Inverter power supply

(capacitor power supply)

Difference in yearly power consumption

146,981kWh

Completelywithout

interruption ofoutput power.

Removes surge and

noise.

3

UPS

Battery

AC switch

Commercial power

Cancel harmonic

Output currentCurrents that include harmonics generated from equipment and

devices

Compensation currentReverse current for harmonic current

Input currentThe commercial power

side is a sine wave with no harmonic components

Facility equipment・Data center equipment・Factory equipment・Power plant, etc.

During parallel redundant operation

When it is completely individual control system

UPS No.1

UPS No.2

UPS No.3

When it is common control system

Control unit

UPS No.1

Commercialpower

UPS No.2

UPS No.3

Facility equipment・Data center equipment・Factory equipment・Power plant, etc.

Commercialpower

Facility equipment・Data center equipment・Factory equipment・Power plant, etc. Control unit

Control unit

Control unit

High reliability3

E33A is the industry's first parallel processing UPS, that can perform parallel redundant operation. In addition, it is a completely individual control system by setting control units to each UPS for parallel operation. The parallel redundant operation with the independent control units makes it highly reliable.

■ Parallel redundant operation

A bi-directional inverter makes the UPS input current into a sine wave. It removes harmonic current from commercial power supply and other equipment. At the same time, power factor is improved and becomes approximately 1.0.

■ Active filter function

■ Automatic battery operation test

Designed with a high overload capacity of 800% (0.5 seconds) and can withstand rush currents of transformer, etc.

Designed for factory equipment4

The UPS runs periodic battery operation tests on its own to maintain the battery in a reliable operating condition in the event of an actual power outage. During testing, power is supplied from the commercial power supply ensuring that power supply can be maintained even if the battery is worn out.

Periodic check

Periodic check

Start of operation check

The battery test is performed while power is supplied from the commercial power supply. When the battery is worn out, a battery replacement alarm sounds. The automatic battery operation test cycle can be changed.

Commercial power AC switch

Commercial power AC switch

Bi-directional inverter

Battery

Filter

Device

Inverter Battery

Filter

Device

Inverter

Battery power supply checkNormal operation

4

■ Networks

 ・LAN interface card *A card that connects to LAN (100Base-T).

 ・UPS management software (SANUPS SOFTWARE)

Specifications

Options

ー 100kVA 200kVA

100kVA 200kVA 300kVA

Expanding the capacity with unit extensionsThe capacity can be expanded by adding a 100kVA unit when required. Up to 300kVA of expansion is possible.*Consider the I/O power cabinet that match the maximum capacity of the expected UPS, from the beginning of the installation.

Parallel operation Output capacity

Parallel redundant operation Output capacity (N+1 units)

UPS unit I/O power cabinet

UPS unit I/O power cabinet

UPS unit

Parallel processing type

The conventional On-line UPS is a double conversion UPS, however this product, SANUPS E33A, using parallel processing type always operates a utility power source and the inverter in parallel redundant at normal mode. It supplies superior quality power to information communications devices and so on.Since this operation, power feeding of SANUPS E33A is highly efficient and reliable.

Item                   Model E33A104 E33A204 E33A304 E33AR104 E33AR204 RemarksSystem Parallel operation Parallel redundant operation

Rated output capacityApparent power 100 kVA 200 kVA 300 kVA 100 kVA 200 kVAEffective power 90 kW 180 kW 270 kW 90 kW 180 kW

Operation system Parallel processing type

AC input

Number of phases / wires 3 phase 3 wires / 3 phase 4 wiresRated voltage 415 V (380, 400, 420 V)Rate frequency 50 / 60HzRequired capacity 120 kVA 240 kVA 360 kVA 120 kVA 240 kVADistorted current compensation

Compensation capacity Within rated capacityCompensation order 2 to 20 order harmonicCompensation rate 75% In case of 3 phase 3 wires

Input power factor 0.97 or higher At rated operations

AC output

Number of phases / wires Same as AC inputRated voltage 415 V (380, 400, 420 V) Same as AC input

Voltage precisionAt commercial parallel operation

Within +10% and -8%

At battery operation Within ± 2%Rate frequency 50 / 60 Hz Same as AC input

Rated frequency precision

At commercial parallel operation

Within ± 5%

At battery operation Within ± 0.5%

Load power factorRating 0.9 (lagging)Variation range 1.0 to 0.7 (lagging)

Voltage wave form distortion factor

At linear load 2% or lessAt battery operationAt rectifier load 5% or less

Instantaneous voltage variation

Variation rate Within ± 5% At battery operation

Overload capacityAt commercial parallel operation

200% (30 seconds), 800% (0.5 seconds)

At battery operation 150% (1 minute), 125% (10 minutes)Switching to battery operation Without momentary power break

Efficiency (commercial parallel operation)

98% or higher Single UPS unit characteristics, load power factor 1.0

Acoustic noise 70 dB 73 dB 76 dB 73 dB 76 dB 1 m from front, height 1 m

Environment

Installation IndoorAmbient temperature 0 °C to 40 °CRelative humidity 20% to 90% (no condensation)Altitude 1000 m or below

* Contact us about the changes on voltage precision and frequency precision.

5

■ Individual battery

Combination UPS unit Backup time Ventilation rate Remarks

E33A104 5 minutes 2.6m3/min10 minutes 4.1m3/min

E33A204 5 minutes 2.6m3/min × 2 sets10 minutes 4.1m3/min

E33A304 5 minutes 2.6m3/min × 3 sets10 minutes 4.1m3/min

E33AR104 5 minutes 2.6m3/min × 2 sets10 minutes 4.1m3/min

E33AR204 5 minutes 2.6m3/min × 3 sets10 minutes 4.1m3/min

Items E33A104 E33A204 E33A304 E33AR104 E33AR204Input capacity 120kVA 240kVA 360kVA 120kVA 240kVAHeating value 2.5kW 5.0kW 7.5kW 3.4kW 5.9kWCooling flow rate 12.8m3/min 25.6m3min 38.4m3/min 17.2m3/min 30.0m3/min

■ UPS unit

Dimension (mm)

W D H700 800 1900

*The backup time for 25˚C ambient temperature and the initial value.*Contact us about the 30, 60, 120, 180 minute backup times and the 0.9 load power factor.

■ Battery cabinet individual battery (for a 0.8 load power factor)

Combination UPS unit

Backup time Dimension (mm)

W D HE33A104 5 minutes 700

800 1900

10 minutes 1100E33A204 5 minutes 700x2

10 minutes 1100x2E33A304 5 minutes 700x3

10 minutes 1100x3E33AR104 5 minutes 700x2

10 minutes 1100x2E33AR204 5 minutes 700x3

10 minutes 1100x3

■ I/O Power cabinet

Combination UPS unit

Dimension (mm)

W D HIndividual battery Common battery (built-in DC branching circuit)Standard type External maintenance bypass type Standard type External maintenance bypass type

E33A104 - (500) - -

800 1900E33A204 800 800 1300 1300E33A304 1000 1000 1500 1500E33AR104 800 800 1300 1300E33AR204 1000 1000 1500 1500

Ventilation rate

Heating value and cooling flow rate

External dimensions

■ Common battery

Combination UPS unit Backup time Ventilation rate Remarks

E33A104 5 minutes 2.6m3/min10 minutes 4.1m3/min

E33A204 5 minutes 5.4m3min10 minutes 8.2m3/min

E33A304 5 minutes 8.0m3/min8 minutes 10.8m3/min

E33AR104 5 minutes 5.4m3/min10 minutes 8.2m3/min

E33AR204 5 minutes 8.0m3/min10 minutes 10.8m3/min

*The calculated values for this chart are 0.9 load power factor, 40˚C room temperature and 30˚C outside air temperature. The heating value and cooling flow rate are the values of the rated output after the battery completes charging.

■ Battery cabinet common battery (for a 0.8 load power factor)

Combination UPS unit

Backup time Dimension (mm)

W D HE33A104 5 minutes 700

800 1900

10 minutes 1100E33A204 5 minutes 1400

10 minutes 2200E33A304 5 minutes 2200

8 minutes 2700E33AR104 5 minutes 700

10 minutes 1100E33AR204 5 minutes 1400

10 minutes 2200

5019

00

700 800

UPS unit

Battery cabinet

I/O power cabinet(Parallel redundant operation)

I/O power cabinet(Parallel operation)

50H

W D

50H

W D

50H

W D

6

■ Parallel Operation (200kVA) / Parallel Redundant Operation (100kVA)

■ Parallel Operation (300kVA) / Parallel Redundant Operation (200kVA)

*For parallel operation if the output is 200kVA or less, the UPS unit can be separated into a single unit.

Without external maintenance bypass

*Contact us about the 2-system input, the output branching, and other system configurations.

Each UPS unit shares a battery (common battery)

With external maintenance bypass

Without external maintenance bypass

With external maintenance bypass

Each UPS unit is connected to a separate battery (individual battery)

Each UPS unit shares a battery (common battery) Each UPS unit is connected to a separate battery (individual battery)

■ Single Operation

UPS unit

Battery

Switch

Switch

Switch

Switch

Circuit breaker

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch

Switch

Switch

Switch

Circuit breaker

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Battery

Battery

Battery

Switch

Switch

SwitchCircuit breaker

Circuit breaker

Circuit breaker

Switch

UPS unit

I/O power board

UPS unit

Switch

Switch

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch Switch

Switch

UPS unit

Switch

Switch

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch Switch

Switch

UPS unit

Circuit breaker

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

UPS unit

Battery

Battery

Switch Switch

Battery

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

UPS unit

Battery

Battery

Switch Switch

Battery

Circuit breaker

Battery

Switch Switch

Circuit breaker

UPS unit

I/O power board

System Configuration Diagram

Circuit breaker

Circuit breaker Circuit

breaker

Circuit breaker

Circuit breaker

Without external maintenance bypass

With external maintenance bypass

7

■ Parallel Operation (200kVA) / Parallel Redundant Operation (100kVA)

■ Parallel Operation (300kVA) / Parallel Redundant Operation (200kVA)

*For parallel operation if the output is 200kVA or less, the UPS unit can be separated into a single unit.

Without external maintenance bypass

*Contact us about the 2-system input, the output branching, and other system configurations.

Each UPS unit shares a battery (common battery)

With external maintenance bypass

Without external maintenance bypass

With external maintenance bypass

Each UPS unit is connected to a separate battery (individual battery)

Each UPS unit shares a battery (common battery) Each UPS unit is connected to a separate battery (individual battery)

■ Single Operation

UPS unit

Battery

Switch

Switch

Switch

Switch

Circuit breaker

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch

Switch

Switch

Switch

Circuit breaker

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Battery

Battery

Battery

Switch

Switch

SwitchCircuit breaker

Circuit breaker

Circuit breaker

Switch

UPS unit

I/O power board

UPS unit

Switch

Switch

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch Switch

Switch

UPS unit

Switch

Switch

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

Battery

Switch Switch

Switch

UPS unit

Circuit breaker

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

UPS unit

Battery

Battery

Switch Switch

Battery

Switch

Switch

Switch

Switch

UPS unit

I/O power board

UPS unit

UPS unit

Battery

Battery

Switch Switch

Battery

Circuit breaker

Battery

Switch Switch

Circuit breaker

UPS unit

I/O power board

System Configuration Diagram

Circuit breaker

Circuit breaker Circuit

breaker

Circuit breaker

Circuit breaker

Without external maintenance bypass

With external maintenance bypass

●Before starting installation, assembling and use, read the “Operation Manual” carefully and use the product correctly in your applications.●When you are going to use this product in the following application, the  special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. (a) Medical equipment and other equipment that are related directly to   human life. (b) Train or elevator that can give injury to human body.  (c) Socially and publicly important computer systems.

 (d) And other equipment that are related to safety of human life and that   can affect severe effects on maintenance of public functions.●For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. ●Never modify this product or give additional processing to this product.●For the installation andmaintenance work, please consult with our company or with specialized company.

※For any inquiry or consultation, please contact our sales representative.

Notes when investigating use of this product in your applications

CATALOG No. P0947B003 ’14.10.IT

The names of companies and/or their products specified in this catalogue are the trade names, and/or trademarks and/or registered trademarks of such respective companies.*Remarks : Specifications Are SubjectTo Change Without Notice.

http://www.sanyodenki.com

TEL: +81 3 5927 1020

TEL: +49 6196 76113 0

TEL: +82 2 773 5623

TEL: +86 21 6235 1107

TEL: +1 310 783 5400

TEL: +33 1 48 63 26 61

TEL: +886 2 2511 3938

TEL: +852 2312 6250

TEL: +65 6223 1071

468 Amapola Avenue Torrance, CA 90501, U.S.A.

3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan

P.A. Paris Nord Ⅱ, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France

Frankfurter Strasse 92, 65760 Eschborn, Germany

988 Toa Payoh North, #04-05/06/07/08, Singapore 319002

Room 2106-2109, Bldg A, Far East International Plaza, No.319, Xianxia Road, Shanghai, 200051, China

TEL: +86 10 6522 2160Room1222, Tower B, Beijing COFCO Plaza, No.8 Jianguomennei Dajie, Dong Cheng District, Beijing 100005 China

N-711, 7F, Chia Hsin 2nd Bldg., No.96, Sec.2, Zhongshan N. Rd., Taipei 10449, Taiwan (R.O.C.)

Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Road, TST East, Kowloon, Hong Kong

9F, Sunhwa B/D 89, Seosomun-ro, Jung-gu, Seoul, 100-731, Korea

TEL: +86 755 3337 38682F 02-11, Shenzhen International Chamber of Commerce Tower, No.168 Fuhua 3 Road, Futian District, Shenzhen, 518048 China

TEL: +66 2261 8670388 Exchange Tower, 25th Floor, Unit 2501-1, Sukhumvit Road, Klongtoey, Klongtoey, Bangkok 10110 Thailand

Beijing Branch

TEL: +86 22 2320 1186Room AB 16th Floor TEDA Building, No. 256 Jie Fang Nan Road, Hexi District, Tianjin 300042 ChinaTianjin Representative Office

TEL: +86 28 8661 6901Room2105B, Block A, Times Plaza, 2 Zongfu Road, Jinjiang District, Chengdu, 610016 ChinaChengdu Representative Office

TEL: + 62 21 252 3202Summitmas II 4th Floor, Jl. Jend. Sudirman Kav.61-62, Jakarta 12190, IndonesiaIndonesia Representative Office

TEL: +82 51 796 5151 8F, CJ Korea Express Bldg., 119, Daegyo-ro, Jung-gu, Busan, 600-016, KoreaBusan Branch