PANEL OVERHANG, TYP. INTERIOR INSTALLATION · interior installation note: 300c panel ends must butt...
Transcript of PANEL OVERHANG, TYP. INTERIOR INSTALLATION · interior installation note: 300c panel ends must butt...
2'-0" MAX
PANEL OVERHANG, TYP.
1" WALL ANGLESEE DETAIL A1.5
PANEL BUTT JOINTSEE DETAIL A1.4
1'-0" MAX CARRIER OVERHANG, TYP.
SUSPENSION REQUIREMENTSSEE DETAIL A1.2
1" WALL ANGLESEE DETAIL A1.5
300C PANEL LENGTH
3'-0" MIN - 19'-8" MAX
TYPICAL SYSTEM SECTIONSEE DETAIL 'A' THIS SHEET
12 GA HANGER WIRE,BY OTHERS, NOT BYHUNTER DOUGLASSEE DETAIL A1.2
300C PANEL WIDTH
11-13/16" NOM.
300C SYSTEM PROFILE1113
16" NOM.
300C PANELSEE DETAIL A1.1
FLOATING TRIMSEE DETAIL A1.6TRIM NOT SHOWNFOR CLARITY
33 16
" NO
M.
300C PANEL
300C CARRIER
SEE DETAILS A1.7THROUGH A1.10FOR FIXTURE OPENINGRECOMMENDATIONS
INTERIOR INSTALLATION
DETAIL 'A'
300C CARRIER SPLICESEE DETAIL A1.3
4'-0" MAX HANGER WIRE SPACING, TYP.
4'-0" MAX CARRIER SPACING, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
OVERALL ISOMETRIC VIEW
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.0
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
FACTORY PANEL SIDE VIEW
13 16
"PA
NEL
HEI
GHT
33 16
" NO
M.
SYST
EM H
EIGH
T
300C CARRIER
3'-0" MINIMUM PANEL LENGTH19'-8" MAXIMUM PANEL LENGTH**
*VERTICAL SUPPORT OMITTED FOR CLARITY**PANEL LENGTHS VARIABLE IN 1/8" INCREMENTS, TOLERANCE ±1/8"
112532" (11.811")
PANEL WIDTH ONLY
PERFORATION #160 ATFACTORY PANEL END
NON-PERFORATEDFACTORY PANEL END
FACTORY PANEL ENDS
13 16
"PA
NEL
HEI
GHT
*SUSPENSION OMITTED FOR CLARITY
300C PANEL MATERIAL THICKNESS
.028" ALUMINUM
300C PANEL FINISHES
PAINTED & POWDER COATED
LUXACOTE
DECORATED WOOD FINISH (POWDER COATED)
WOOD VENEER
AVAILABLE PANEL PERFORATION
PERFORATION #160PERF AREA 23% OPEN
HOLE DIAMETER 0.060"
PERFORATIONDIRECTION
112532" (11.811")
PANEL WIDTH
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
PANEL SPECIFICATIONS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.1
SCALE: NOT TO SCALE
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
SIDE VIEW OF 300C CARRIER WITH PANEL
SIDE VIEW OF 300C CARRIER
END VIEW OF 300C CARRIER WITH PANEL
END VIEW OF 300C CARRIER
300C CARRIER
MATERIAL: .040" ALUMINUM
FINISH: MATTE BLACK
PART LENGTH: 16'-0"
NOTE: 300C CARRIERS ARE DIRECTIONAL, CHECKORIENTATION PRIOR TO INSTALLATION4'-0" MAX
HANGER WIRE SPACING, TYP.
1'-0" MAX
CARRIER OVERHANG, TYP.
300C PANEL
12 GA HANGER WIRE,BY OTHERS, NOT BYHUNTER DOUGLAS
2'-0" MAX PANEL OVERHANG, TYP.
4'-0" MAX CARRIER SPACING, TYP.300C CARRIER
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the property
of CertainTeed Ceilings
Corporation. It may not
be copied or multiplied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
SUSPENSION SPECIFICATIONS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.2
SCALE: NOT TO SCALE
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
12 GA HANGER WIRE, NOTBY HUNTER DOUGLAS
SECTION 'A' - 'A'
CARRIER SPLICE
SNAP SPLICE TABS INTO 300CCARRIER
12" MAXIMUM ATCARRIER SPLICE
12" MAXIMUM ATCARRIER SPLICE
300C PANEL300C CARRIER 12"MAXIMUM AT
CARRIER SPLICE
12"MAXIMUM AT
CARRIER SPLICE
33 16
" NO
M.
12 GA HANGER WIRE, NOTBY HUNTER DOUGLAS
IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUMOF 16'-0", USE A LUXALON CARRIER SPLICE, TO CONNECTTWO FACTORY CARRIER ENDS.
THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THECARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THEMODULE IS CONTINUED AUTOMATICALLY.
'A'
'A'
INTERIOR INSTALLATION
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
CARRIER SPLICE
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.3
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
300C PANEL
24" MAXIMUM PANEL OVERHANG
12 GA HANGER WIREBY OTHERS, TYP.
300C CARRIER
4'-0" MAX CARRIER SPACING, TYP.
24" MAXIMUM PANEL OVERHANG
ISOMETRIC VIEW OF FACTORY PANEL ENDS AT JOINT*CARRIERS NOT SHOWN FOR CLARITY
INTERIOR INSTALLATION
NOTE: 300C PANEL ENDS MUST BUTT AT FACTORY PANEL ENDS ANDPANELS CANNOT BE SPLICED. PANEL ENDS CAN ONLY BE FIELD CUTAT PERIMETERS WHERE TRIMS ARE USED FOR TERMINATIONS.PANEL SPLICES ARE NOT REQUIRED NOR AVAILABLE.
DO NOT FASTEN PANEL ENDS TOGETHER. DOINGSO WILL CAUSE DEFORMATION IN PANEL FACE.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
PANEL BUTT JOINT
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.4
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
FIELD CUT 300CPANEL SIDESFOR WIDTH
FIELD CUT 300C PANEL ENDSFOR LENGTH
1" WALL ANGLE
FACTORY PANELENDS
SECTION VIEW AT 1" WALL ANGLE & 300C PANEL SIDE
1" WALL ANGLE
12'-0" PART LENGTH
1"
1"
USE WALL ANGLE TO SECURE CUT PANELSIDE. TYPICALLY NOT REQUIRED ATFIELD CUT PANEL ENDS.
1"
FACTORY PANELENDS
USE WALL ANGLE ASHOLD DOWN CLIP
FIELD CUT 300C PANEL SIDE
SUSPENSION NOT SHOWN FOR CLARITY
DIRECT FASTEN 1" WALLANGLE TO STRUCTURE
FIELD MITER TRIMS AT CORNERS
1"
*VERTICAL SUPPORT OMITTED FOR CLARITYINTERIOR INSTALLATION
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
WALL ANGLE TRIM
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.5
SCALE: NOT TO SCALE
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
10'-0" PART LENGTH
1"
3-3/
16"
2-1/4"
FIELD CUT 300C PANEL SIDESFOR WIDTH
FULL 300C PANELS
1" WALL ANGLE TO SECURE FIELD CUT PANELSIDE. TYPICALLY NOT REQUIRED AT FIELDCUT PANEL ENDS & FULL PANEL EDGES.
FIELD CUT 300CPANEL ENDS
FASTENERS TO SECURE300C J-TRIM TO CARRIERBY OTHERS, TYP.
300C J-TRIM FORFLOATING CONDITION
DOUBLE-SIDEDADHESIVE TOSECURE TRIM ANGLE
300C CARRIER
FIELD CUTPANEL SIDE USE TRIM ANGLE AS
HOLD DOWN
33 16
"
214"
1"
2-1/4"
1"FIELD CUTPANEL END
3-3/
16"
12 GA HANGER WIRE,NOTCH TRIM ASNECESSARY, TYP.
FIELD MITER TRIMSAT CORNERS
INTERIOR INSTALLATION
'A'
'B'
SECTION 'A'SCALE: 6" = 1'-0"
SECTION 'B'SCALE: 6" = 1'-0"
*VERTICAL SUPPORT OMITTED FOR CLARITY
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
FLOATING TRIM
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.6
SCALE: NOT TO SCALE
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
300C PANEL FIELD CUT FORFIXTURE OPENING
RECOMMENDED 8" MAX WIDTHFOR FIELD CUT OPENING
CENTERED IN PANEL
8" MAX WIDTH CENTERED
IN PANEL RECOMMENDED
MAX LENGTH VARIES BASED
ON PANEL LENGTH
2" MIN FROM
PANEL END, TYP.
INTERRUPT CARRIER AT FIXTURELOCATION, TYP.
MAX
VAR
IES
BASE
DO
N P
ANEL
LEN
GTH
2" M
IN F
ROM
PAN
EL E
ND,
TYP
.
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS
FIELD CUT 300C PANEL
INTERRUPT CARRIER AT FIXTURE
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FIELD CUT 300C PANEL
FIXTURE TO BE INDEPENDENTLYSUPPORTED BY OTHERS 300C CARRIER BEYOND
'A' 'A'
'B'
'B'
SECTION 'A' - 'A' SECTION 'B' - 'B'
NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIMFOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS
4'-6" MAX CARRIER SPACING
ALLOWABLE AT FIXTURES, TYP.
ROUND OPENINGS FORCAN LIGHTS, SPEAKERS,SPRINKLERS, ETC.
4'-6
" MAX
CAR
RIER
SPAC
ING
ALLO
WAB
LEAT
FIX
TURE
S, T
YP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the property
of CertainTeed Ceilings
Corporation. It may not
be copied or multiplied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
FIELD CUT PANEL FOR FIXTURE OPENINGS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.7
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
VARIES TO ACCOMMODATE FIXTURE WIDTH
11.811" MAX WIDTH TO REMAIN ON MODULE
MAX LENGTH VARIES BASED
ON PANEL LENGTH
FACTORY 300C PANELS
INTERRUPT CARRIER AT FIXTURELOCATION, TYP.
'A' 'A'
'B'
'B'11.811" MAX WIDTH
TO REMAIN ON MODULE
MAX
VAR
IES
BASE
DO
N P
ANEL
LEN
GTH
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS
FIELD CUT 300C PANEL
INTERRUPT CARRIER AT FIXTURE
FULL 300C PANEL
FIXTURE TO BE INDEPENDENTLYSUPPORTED BY OTHERS 300C CARRIER BEYOND
SECTION 'A' - 'A'
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FULL 300C PANEL
SECTION 'B' - 'B'
NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
INTERRUPTED PANEL FOR FIXTURE OPENINGS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.8
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
FIXTURE CUT IN 300C PANEL FACE
MAX WIDTH VARIES BASED
ON PANEL LENGTH
MAX LENGTH VARIES
2" MIN FROM
PANEL SIDE, TYP.
'A'
'B'
'B'
'A'
FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERSCONTINUOUS 300CCARRIER BEYOND
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FIELD CUT 300C PANEL
SECTION 'A' - 'A'
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FIELD CUT 300C PANEL
300C CARRIER
FIXTURE TO BE INDEPENDENTLYSUPPORTED BY OTHERS
SECTION 'B' - 'B'
MAX WIDTH VARIES2" MIN FROM
PANEL SIDE, TYP.
4'-6
" MAX
CAR
RIER
SPA
CIN
GAL
LOW
ABLE
AT
FIXT
URE
S, T
YP.
MAX
WID
TH V
ARIE
S BA
SED
ON
PAN
EL L
ENGT
H
NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIMFOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS
4'-6" MAX CARRIER SPACING
ALLOWABLE AT FIXTURES, TYP.
4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
FIELD CUT PANEL FOR FIXTURE OPENINGS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.9
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
MAX LENGTH VARIES BASED
ON 11.811" INCREMENTS
(PANEL WIDTH)
MAX WIDTH VARIES
FACTORY FULL 300C PANELS
'A' 'A'
MAX WIDTH VARIES BASEDON 11.811" INCREMENTS
(PANEL WIDTH) OPE
NIN
G W
IDTH
VAR
IES
SECTION 'A' - 'A'
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FULL 300C PANEL
SECTION 'B' - 'B'
FIXTURE WITH TRIM FLANGE REQUIRED, BYOTHERS, NOT BY HUNTER DOUGLAS
FULL 300C PANEL
FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERSCONTINUOUS 300CCARRIER BEYOND
'B'
'B'
NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS
PANEL LENGTHS FACTORYFABRICATED TO MAINTAINPANEL SEAM MODULE
4'-6
" MAX
CAR
RIER
SPA
CIN
GAL
LOW
ABLE
AT
FIXT
URE
S, T
YP.
4'-6" MAX CARRIER SPACING
ALLOWABLE AT FIXTURES, TYP.
300C CARRIER
FIXTURE TO BE INDEPENDENTLYSUPPORTED BY OTHERS
4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
INTERRUPTED PANEL FOR FIXTURE OPENINGS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.10
SCALE: 3" = 1'-0"
DRAWN BY: HD ENGINEERING
DATE: 1/28/19
N
S
SPLAYED 12 GA HANGERWIRE, BY OTHERS, TYP.
300C PANEL
COMPRESSION STRUT
E
300C CARRIER
INTERIOR INSTALLATION
W
45°
45°
45°
45°
LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND INACCORDANCE WITH LOCAL CODE REQUIREMENTS.
(4) #12 GAUGE WIRES SPLAYED 90° FROM EACH OTHER AT ANGLE NOT EXCEEDING 45°FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TOAND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACEDNOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN6 FEET FROM EACH WALL.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800.366.4327
F 770.806.0214
CTSpecialtyCeilings.com
All r ights reserved. This
drawing is the proper ty
of CertainTeed Ceilings
Corporation. It may not
be copied or mult ipl ied,
n e i t h e r w h o l l y n o r
par t l y . I t may not be
submitted f or perusal to
t h i r d p a r t i e s .
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .028" ALUMINUM 300C PANEL | .040" ALUMINUM 300C CARRIER
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | WOOD
VENEER | LUXACOTE
PERFORATION: NON-PERFORATED | #160
SEISMIC SPECIFICATIONS
PROJECT: 300C PRODUCT SPECIFICATIONS
DRAWING NUMBER: 300C-A1.11
SCALE: NOT TO SCALE
DRAWN BY: HD ENGINEERING