PANEL LAYOUT N.T.S. APRIL 2009...Title Scale Date Design Office Drawing No. N.T.S. APRIL 2009...
Transcript of PANEL LAYOUT N.T.S. APRIL 2009...Title Scale Date Design Office Drawing No. N.T.S. APRIL 2009...
Title
Scale Date
Drawing No.Design Office
N.T.S. APRIL 2009
SL/SPEC/46
MINI FEEDER PILLAR
PANEL LAYOUT
All Ayrshire Specification
ISOL
SUPPLYAUTHORITY
POWERSERVICE
FUSE
BACKBOARD
32A D/P
NL
NL
MCB MCBN N E
SUPPLYAUTHORITY
FUSEPOSITION TOBE MARKED
ONBACKBOARDAT FACTORY
CONE GROMMETFOR SP DOUBLE
INSULATED TAILS
65
mm
155mm
58
5m
m
3mm BRASSGLAND PLATE
WITH 3 NO 25mmCABLE ENTRYS
2 No FUSES ORMCB'S
POST TOP MOUNTED LUMINAIRES
20mm Flexible
conduit clipped
to sign rail
SIGN
BACK
Sign cables 1.5 sq mm 3 core flexible.
All conduit holes
to be painted
Base compartment
3 way cutout
TRAFFIC SIGN LIGHTING
MULTIPLE LUMINAIRE ARRANGEMENT
Sign pole & shaft diameters may vary.
Cap over brackets of the correct size should be obtained.
A base compartment must be provided.
Jack pole
Underground cable
entry slot
100 mm
GROUND
LEVEL
Title
Scale Date
Drawing No.Design Office
N.T.S.
SL/SPEC/12
APRIL 2009
min height2.1m verge2.30m footway
All Ayrshire Specification
Title
Scale Date
Drawing No.Design Office
N.T.S.
P.E.C.U. CONNECTION TO
HIGHWAY DISTRIBUTION BOARD
APRIL2009
SL/SPEC/13
L2 N L
LUMINAIREP.E.C.U.
NL2 L
P.E.C.U.
TERMINAL
BLOCK
NL
HIGHWAY DISTRIBUTION UNIT
L N
L N L NL N L N
L N
L N E
EA
RT
H
PE
CU
CO
NT
AC
TO
R
PEC CONNECTIONS
LUMINAIRE CONNECTIONS
PECLUMINAIRE
FU
SE
ISOL ISOL
L NL2
L N
20A
MCB
3 CORE 1.5mm²
FLEXIBLE CABLE
3 CORE 1.5mm²
FLEXIBLE CABLE
PECU CUT OUT
2.5 mm² 4 CORE XLPE/SWA/PVCCABLE
16 mm² 3 CORE XLPE/SWA/PVCCABLE
All Ayrshire Specification
Title
Scale Date
Drawing No.Design Office
N.T.S.
HIGHWAY DISTRIBUTION BOARD PANELSINGLE PHASE SWITCHED SCHEMATIC
SL/SPEC/23APRIL 2009
All Ayrshire Specification
M9
20A
OUTGOING MCB'S
TYPE C
TERMINAL BLOCK FORPHOTO ELECTRIC CONTROL
N
UNIT
1 2 43
63ACONTACTOR
N
COIL 230V 50Hz
6AMCBA
HEATER
6AMCBB
C
FUSE SWITCH 63A
INCOMING SUPPLY
neutral
230v 1ph 2 WIRE 50Hz
OVER-RIDE SWITCH
OPTIONAL
Title
Scale Date
Drawing No.Design Office
N.T.S.
OVER-RIDE SWITCH
HIGHWAY DISTRIBUTION UNITLAYOUT OF PANEL WITHIN ENCLOSURE
SL/SPEC/26
APRIL 2009
BRASS GLAND PLATEFOR REQUIRED NO OF
EARTH STUDS
PILLAR SHELL
CONTACTOR
FUSE
SWITCH
MCB's
MARSHALLING
AREA
PANEL
SUPPLYAUTHORITY
CABLEHEAD
Supplementary Bonding
Conductor (10mm sq)
All Ayrshire Specification
400mm MAX
50
0m
m
CIRCUITS5
0m
m
GROUND LEVEL
BASE PLATE
606mm MAX
10
10
mm
MA
X
Design Office
Title
DRAWING SYMBOLS
SHEET 1
SL/SPEC/37
Scale JULY 2001N.T.S. Date
Drawing No.
TRAFFIC SIGN COLUMN COMPLETE WITH T8 SIGN LANTERN
EXISTING LIGHTING COLUMN TO BE REMOVED
TRAFFIC SIGN COLUMN COMPLETE WITH DOUBLE ARM ANDT8 SIGN LANTERNS
BOLLARD
6m INTEGRAL STEEL LIGHTING COLUMN
4m POST TOP STEEL LIGHTING COLUMN
8m STEEL LIGHTING COLUMN COMPLETE WITH BRACKET
10m STEEL LIGHTING COLUMN COMPLETE WITH BRACKET
EXISTING LIGHTING COLUMN TO REMAIN
12m STEEL LIGHTING COLUMN COMPLETE WITH BRACKET
All Ayrshire Specification
PROPOSED 6mm STEEL WIRE ARMOUR CABLE ENCLOSED IN DUCT
PROPOSED 16mm STEEL WIRE ARMOUR CABLE ENCLOSED IN DUCT
EXISTING UNDERGROUND CABLE TO REMAIN
D.P.
PROPOSED
EXISTING OVERHEAD CABLE TO REMAIN
Design Office
Title
DRAWING SYMBOLS
SHEET 2
OVERHEAD CABLE TO BE REMOVED
OVERHEAD CABLE
CABLING
DISTRIBUTION PILLAR
DESCRIPTION
EARTH ELECTRODE
N.T.S.Scale JULY 2001
Drawing No. SL/SPEC/38
Date
O/HO/H
.. O/H
O/H
.O/H
O/H
REMAINEXISTING TO
D.P. D.P.
REMOVEEXISTING TO
All Ayrshire Specification
SPECIFICATION FOR THE
REINSTATEMENT OF
FOOTWAYS & FOOTPATHS
Title
Scale Date
Drawing No.Design Office
N.T.S. APRIL 2009
SL/SPEC/43
SA
WC
UT
ED
GE
SA
WC
UT
ED
GE
SA
WC
UT
ED
GE
SA
WC
UT
ED
GE
Su
rface
Co
urse
Bin
de
rC
ou
rse
Su
b-b
ase
Ba
ckfill
Su
rrou
nd
toD
uct
Du
ctD
uct
Du
ct
Co
ncre
teS
urfa
ceS
lab
Ba
ckfill
Ba
ckfill
Su
b-b
ase
Su
b-b
ase
Be
dd
ing
Pa
vin
gM
od
ule
s
Su
rrou
nd
toD
uct
Su
rrou
nd
toD
uct
Fle
xib
le/
Co
mp
osite
Foo
tway
Re
insta
tem
ent
Rig
idF
oo
tway
Re
insta
tem
ent
Mo
du
lar
Foo
tway
Re
insta
tem
entFo
otw
ay
Ru
nn
ing
Su
rface
Fo
otw
ay
Ru
nn
ing
Su
rface
Fo
otw
ay
Ru
nn
ing
Su
rface
450mm cover
450mm cover
Re
insta
tem
ent
Stru
ctu
reto
be
inA
ccord
ance
toA
ppendix
A7.1
of
RA
UC
(S)
20
03.
Re
insta
tem
ent
Stru
ctu
reto
be
inA
ccord
ance
toA
ppendix
A7.2
of
RA
UC
(S)
20
03.
Re
insta
tem
ent
Stru
ctu
reto
be
inA
ccord
ance
toA
ppendix
A7.3
of
RA
UC
(S)
20
03.
Ma
rker
tap
e
Ma
rker
tap
e
Ma
rker
tap
e
No
te1
-A
llve
rtica
lfa
ce
sto
be
ho
tp
itch
ed
pain
ted
or
an
appro
ved
alte
rnativ
eN
ote
2-
All
join
tsto
be
ho
tp
itch
ed
pa
inte
dor
an
appro
ved
alte
rnativ
e.
450mm cover
Tre
nch
Wid
th300m
mT
ren
ch
De
pth
625m
mT
ren
ch
Wid
th300m
mT
ren
ch
De
pth
625m
m
Tre
nch
Wid
th300m
mT
ren
ch
De
pth
625m
m
All Ayrshire Specification