Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

23
Page 1 Unrestricted Internal Use Unrestricted Internal Use PoC LLI Sales Training January 15, 2010

Transcript of Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 1: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 1Unrestricted Internal Use

Unrestricted Internal Use

PoC LLI Sales TrainingJanuary 15, 2010

Page 2: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 2Unrestricted Internal Use

Agenda

Training Objectives

Why LLI? Target Customers / Market

Value Proposition

The Carestream Long Length Imaging System &

Components

Key Selling Points

Catalogue Numbers / Pricing

Availability

Page 3: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 3Unrestricted Internal Use

Training Objectives

Understand the target customers and market

Understand the CSH LLI solution, the benefit to the customer, and the LLI

options

Ability to successfully sell the solution

Page 4: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 4Unrestricted Internal Use

Why LLI? Target Customers / Market

Long Length Imaging (LLI) exams include scoliosis and

other leg-length exams that require a larger area to be

imaged than can fit on a typical 14” x 17” screen

Target: Facilities that would perform long length exams

include hospitals, general imaging centers, orthopedic

clinics, and chiropractic offices

Page 5: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 5Unrestricted Internal Use

Target Customers

Target: Customers looking for solutions enabling imaging of full spines, lower

extremities with patients in an erect or supine position and a solution that can be

used in multiple places:

On the radiology table in the x-ray roomIn the x-ray room with patients in an upright position with cassette against a wallBed side exams where the cassette would be pushed under the patientIn the operating room

Page 6: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 6Unrestricted Internal Use

Target Customers

Target: Customers wanting to transition

more of their radiography operations

for digital for:

Improved workflow

Eliminating film and storage

expense

Having easy access and

distribution of images

Target Decision Makers: Radiology

administrators / Office managers

Target Influencers: Radiologists,

Orthopedic surgeons, Radiology

technologists

Page 7: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 7Unrestricted Internal Use

Value Proposition

Enjoy the benefits of digital capture and processing of long length exams with

the easy to use Carestream Long Length Imaging System and your PoC 360

system

Page 8: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 8Unrestricted Internal Use

The Carestream Long Length Imaging System

The Carestream Long Length Imaging System will be an option for new Kodak

PoC 360 Systems and the Carestream Vita CR (currently in development)

The LLI System will also be available as an upgrade option to the installed base

of PoC 360 Systems

The LLI System will work on CRs in the tabletop configuration only– it will not

work on readers on Z-Carts

Accessory options include a portable caddy with grid, wall stand holder with grid

and beam attenuation filters

Always present this option as part of the PoC 360 sale

for customers performing long length exams

Page 9: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 9Unrestricted Internal Use

The Carestream Long Length Imaging

System uses a single Carestream GP

flexible screen and double-ended 14” x 33”

cassette

Weight 10.8lbs / 4.9kg

Size 14” x 33” / 35 x 84cm

Source to Image Distance (SID)

40-72” / 102-183cm

LLI System Components – Screen & Cassette

Page 10: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 10Unrestricted Internal Use

LLI System Components – Screen & Cassette Cont.

The tech is able to use the solution in full daylight conditions- no need to use in

subdued light or darkroom to load or process the cassette

After exposure, the tech will first insert the cassette end labeled #1 in the PoC

360; When the scanning is complete the tech will then insert the end labeled #2

to scan the opposite end of the screen.

The software will automatically stitch and display the resulting image for review

Page 11: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 11Unrestricted Internal Use

LLI System Components - Software

Software Version 3.0 SP5 is required + LLI Stitching Software License

(CAT no. 8135006 or 8201212 – Page 14)

The user would select the Full Spine / Full Leg exams from the

Organs/Sub-Organs Buttons

Page 12: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 12Unrestricted Internal Use

LLI System Components – Software Cont.As part of the Kodak QC Software, a stitching algorithm is used to automatically

combine the 2 scanned images into a single image for display– this is the same

algorithm used for the Kodak DirectView LLI products

There is no need to manually align, order or rotate images in

preparation for stitching– the software does it automatically

Distribute the stitched image to softcopy workstations or

hardcopy laser imagers just like any other scanned image

Note: Printing true size will not fit a regular paper size

Page 13: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 13Unrestricted Internal Use

LLI System Components – Support Bracket

The LLI system will use a support bracket attached to the reader to support the

long cassette while it is inserted in the scanner

This stabilizing mechanism prevents plate movement and cassette distortion over

time

The support bracket slides out of the way when a long length cassette is not in use

Page 14: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 14Unrestricted Internal Use

LLI System Components – Portable Caddy with Grid

The portable caddy with grid allows for imaging of supine long length exams or

could be hung on the wall for upright exams

Easily move from location to location

Grid cannot be removed

Note: Can NOT be used interchangeably with the DirectView Portable Caddy, as

cassettes are different sizes

Weight 17lbs / 7.7 kg

Size 17”W x 1.2”D x 40.2”L / 43 x 3 x 102 cm

Grid Ratio8:1 with 103 LPI

Page 15: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 15Unrestricted Internal Use

LLI System Components – Vertical Cassette Holder with GridConveniently holds LLI cassette for upright long length exams

Has a range of ½” from the floor to 74” and can be adjusted in 1” increments to

accommodate the patient height and body part to be imaged

Can use close to the floor to image the ankle for leg-length exams – eliminates the

need of the patient climbing a step

Grid cannot be removed

Note: Can NOT be used interchangeably with the DirectView Vertical Cassette

Holder, as cassettes are different size

Grid Ratio8:1 with 103 LPI (Same as portable caddy)

Page 16: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 16Unrestricted Internal Use

LLI System Components – Beam Attenuating Filters

Required for optimum image quality

Beam Attenuation Filters help ensure uniform exposure by compensating for varying

degrees of body thickness; This creates a more uniform density and look throughout

the stitched image

CSH provides these as an option for customers who do not currently own filters

The attenuating filters are made of a lead-plastic material that is 30% lead by weight.

Since lead is an efficient absorber of x-ray the filters attenuate the x-ray beam

Page 17: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 17Unrestricted Internal Use

LLI System Components – Beam Attenuating Filters Cont.

The filters are magnetically held in

place by a filter holder (Cat# 1686526)

that easily attaches to the collimator

accessory tray

2 filters are available:Lateral thoracic spine

CAT# 8515157

AP/PA

CAT# 1955046

Page 18: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 18Unrestricted Internal Use

Beam Attenuating Filters – Patient Positioning

AP/PA Beam Attenuation Filter CAT# 1955046

Beam Attenuation Filter Holder CAT# 1686526

Lateral Beam Attenuation Filter CAT# 8515157

Page 19: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 19Unrestricted Internal Use

Workflow

Double click the Acrobat icon below to view a detailed LLI procedure for Vita

Adobe Acrobat Document

Page 20: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 20Unrestricted Internal Use

Key Selling Points

The Carestream Long Length Imaging System allows customers to move their

scoliosis and leg-length exams to digital for improved workflow, easy access to

images and easy storage

The portable caddy with grid allows users to perform bedside supine exams for

broader use; Gridded exams provide higher image quality to the radiologist; The

caddy with wheels makes it easy for the tech to move from room to room

The vertical holder with grid allows easy positioning of the patient for upright

exams; The user can quickly place the cassette for the exam needed– extends

from the ½” off the floor to 74”

Page 21: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 21Unrestricted Internal Use

Key Selling Points – Cont.

The Carestream automatic stitching software uses a proven algorithm for fast

and accurate stitching; No tech interaction is required

LLI cassettes are lighter than their analog alternatives (approx 2.5lbs) making it

easier for the tech to move around

The beam attenuation filters and holder provide a uniform image from top to

bottom making it easier for the radiologist to make their diagnosis

Page 22: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 22Unrestricted Internal Use

Availability

Availability of the Carestream Long Length Imaging System and Components is

Q1 2010

Page 23: Page 1 Unrestricted Internal Use PoC LLI Sales Training January 15, 2010.

Page 23Unrestricted Internal Use