Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 [email protected].
-
Upload
wyatt-bovell -
Category
Documents
-
view
219 -
download
1
Transcript of Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 [email protected].
![Page 2: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/2.jpg)
Page 2
Outline
• Why the rush to clean it up?
• The Issues
• House wiring architectures
• Component Requirements
• Testing & Troubleshooting
• Recommendations
• Suggestions for a more available service
![Page 3: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/3.jpg)
Page 3
Competition Drives the Market to New Sources of Revenue
• High speed data services (Internet) becoming viable with
availability of cable modems and xDSL technology
• Work at home (Teleworkers & Telecommuters)
• Internet access (news, research, etc.)
• Home banking
• Digital video technology maturing and viable business as shown
in widespread DBS application
• Telephony in a bundled package is attractive to consumers
• Bundled services and one-stop-shop offer lower overhead,
cheaper rates, and less confusion
![Page 4: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/4.jpg)
Page 4
Companies Planning New Digital Services
• Cable companies
• Typically coaxial and broadband RF
• Many houses wired by subcontractors or the homeowner
• Issues arise when new services are added:
• High speed data
• DTV
• Telephony
![Page 5: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/5.jpg)
Page 5
Home LANs on the Rise• Tele-workers and Tele-commuters
• Multiple computers
• Sharing of peripherals
• Printers, cable modem, fax, VCR, etc.
• File sharing
• Security could be an issue
• “Always-on” connection with cable modem
• Firewall software may be required
![Page 6: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/6.jpg)
Page 6
Home Wiring is the Weak Point• 75 - 90% of ingress is caused in the home & wreaks havoc on
reverse path
• Find in the home before connecting to the network
• One house can take down the whole node!
• Must be monitored continuously and eliminated quickly
• Home wired with poor componentry and craftsmanship
• Microreflections
• Frequency response variation & excessive loss
• Leakage & Ingress
• Replacing all home wiring is unacceptable
• Testing is required to bring it up to standards
![Page 7: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/7.jpg)
Page 7
Customer Premise Equipment (CPE)
• Passives
• Drop line, CAT5 cable, USB/Ethernet adapter
• In-house splitters, filters, & DCs
• Barrels and in-line pads
• Actives
• House amp
• NID
• Settop box
• Cable modem
![Page 8: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/8.jpg)
Page 8
Distribution System
26 23 17 4350’ 500’ 600’
![Page 9: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/9.jpg)
Page 9
New Technology, Old Wiring Habits
Tap
NID
![Page 10: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/10.jpg)
Page 10
The Home Network
NID
DirectionalCoupler
WW
![Page 11: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/11.jpg)
Page 12
Path Loss
• Forward path loss:
• Tap value
• Drop cable size, length, and frequency
• House loss and gain for passives and actives
• Reverse path loss:
• Tap value (first or last tap)
• Type of amplifier (trunk, bridger, LE, passive amp)
• Balancing scenario (port or hybrid)
• Home network architecture
• Home-run wiring
• House amp, NID, filters, A/B switches, etc.
• Splitters or DCs
![Page 12: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/12.jpg)
Page 13
NID Powering• Distribution powering
• 60 or 90 Vac
• Current draw
• Centralized powering
• Drop line powering or Siamese cables
• MOVs and power routing
• Residential powering
• Reliable source (amperage capability)
• Battery backup (8 hours?)
• How many phones will be ringing?
![Page 13: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/13.jpg)
Page 14
House Protection
• NEC article 820
• Direct buried 12 inches deep
• Protected to a height of 8 feet on buildings
• NEC article 830
• 18 inches deep or 6” in metal conduit
• Protected to a height of 8 feet on buildings
or
• Use of fault protection devices
![Page 14: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/14.jpg)
Page 15
Drop Cable Types
• Commonly known as drop line
• RG-59 (rarely used)
• RG-6
• RG-7
• Impedance 75 ohms +/- 2
• Not RG-58!
![Page 15: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/15.jpg)
Page 16
Drop Line Specifications
• No smaller than RG-6 for > 550 MHz
• RG-7 or RG-11 for spans more than 150’
• Tested from 5 MHz to 1 GHz
• Tri or Quad shield
• Bonded foil
• At least 60% braid
• Be wary of the VCR cable jumper
![Page 16: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/16.jpg)
Page 17
Drop Connectors
• 80 dB or better shielding effectiveness up to 1 GHz
• Seal connections at the connector/cable interface
• Prevents ingress/egress
• Provides protection from the weather
• Use a boot with silicon if warranted
• Compression fittings - not screw-on types
• Still have to verify the right connector for the style of
cable and proper installation
![Page 17: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/17.jpg)
Page 18
House Passives
• 110 dB EMI shielding from 5 MHz to 1 GHz
• > 15 dB input/output return loss
• > 18 dB isolation
• Should be much better than this
• Rugged housing and backplate
• Voltage blocking capacitors
• UL listed and meets ASTM specs for galvanizing
![Page 18: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/18.jpg)
Page 19
CPE Requirements• 0 dBmV for the TV
• 3 dBmV for a settop box
• May be surprised by the loss of VCRs and games
• VCR cables should be examined for quality
• Modems require +/- 15 dBmV (analog)
• NIDs
• House amps
• Don’t pad the input below a certain level
• Pad the output if necessary
![Page 19: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/19.jpg)
Page 20
Subscriber Drop Remains the Weakest Link
• Least equipped to deliver interactive digital services
• Most labor intensive part of the network
• Costliest part of the network
• Seven out of ten service calls are generated by
problems at the drop
• Even with today’s more forgiving analog signals
• What’s the failure rate gonna be with digital signals
of tomorrow and NID powering?
• If problems continue, customers will go elsewhere
![Page 20: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/20.jpg)
Page 21
Testing and Troubleshooting• Measuring all signal levels is a standard requirement
for analog CATV services
• Test for ingress prior to connecting the drop to the
tap
• Possibly go in the house and turn on noisy motors
• Vacuum cleaner, hair dryer, electric drill
• Can opener, CB, Ham, etc.
• Testing for leakage helps find wiring damage or poor
craftsmanship
• Not all leaks are ingress points and vice-versa
• Some problems are frequency selective
![Page 21: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/21.jpg)
Page 22
More Testing Ideas
• Check frequency response to ensure no band-
edge problems
• Indicates faulty components or poor
craftsmanship
• Locating faults for repair is simplified with
frequency domain reflectometry
• Process of elimination is used when test
equipment is unavailable
• Measurements will locate potential problems
• Sometimes problems don’t show up with a
simple “see if the modem works” test
![Page 22: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/22.jpg)
Page 23
TAP
Drop Cable
To modem or terminated wall plateTo TV / converter or terminated wall plate
2-wa
y sp
litter
Typical Home Wiring Evaluation• SIGNAL LEVELS / SCAN
• Verify FCC or recommended system levels from tap / drop
• SWEEP
• Characterize frequency response
• LOCATE • Pinpoint cable / component problems within
the residence
• INSTALLATION TEST
• Hard copy and proof!
• INGRESS
• LEAKAGE
• DOWNLOAD to StealthWare
![Page 23: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/23.jpg)
Page 24
Test Equipment Features• Locate (FDR) mode
• Sweep mode
• Digital Option (Quick Check or Digi-Check modes)
• 5-890 MHz Ingress Scan
• Abundant file storage capacity
• Dedicated tagged leakage signal source at
subscriber drop (no guesswork or false alarms)
• Transmit a CW carrier (+30 dBmV) from 5-800 MHz
for subscriber troubleshooting
![Page 24: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/24.jpg)
Page 25
Checking Frequency Response• Sweep is inserted at tap and/or ground block and
measured at subscriber terminal locations
• Look for standing waves
• Excessive loss
• Roll-offs
• “Suck-outs”
• Frequency response helps identify faulty or non-
standard components
• Can be used to verify loss of cable and non-
termination
![Page 25: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/25.jpg)
Page 26
?
TAP
Identify Faulty or Non-Standard Components
• Connectors & cable
• Passives (splitters, filters, etc.)
• One way subscriber amp in a two
way system?
![Page 26: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/26.jpg)
Page 27
AfterTerminating all wall plates & installing
quality passives Failure to properly terminate wall plates, or
installing poor quality signal splitting devices
Before
Effects of Impedance Mismatches
![Page 27: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/27.jpg)
Page 28
TAP
Drop Cable
2-way splitter
Connect to dropcable or ground block
for ingress test
Ingress Scanning• 5 - 890 MHz Range
• Peak hold function to catch
transient ingress signals
![Page 28: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/28.jpg)
Page 29
TDR• Injects DC pulses (reflects little energy at RF
faults)
• Nearly 100% of the source energy is reflected
by any in-line frequency selective device
• Tends to roll off rapidly at high frequencies
• < 2% of pulse energy is distributed in the RF
ranges
![Page 29: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/29.jpg)
Page 30
Frequency Domain Relectometer
• FDR is the measure of the reflections of a medium
across frequency
• Part of the energy is reflected back if the load is not a
perfect match of 75 ohms
• The reflected energy will be the same frequency as
the incident wave but 180o out of phase
• The resulting wave (incident + reflected) will appear
as standing waves on the frequency sweep
• This can be correlated to a distance vs fault display
![Page 30: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/30.jpg)
Page 31
FDR• Sweeps the system at radio frequencies
• Sensitive to RF problems, accurately identifies return
loss, and operator selectable resolution
• Fault vs. distance and Return Loss (SWR) per Event
• No need for access to the subscriber’s house
• Advantageous to know the internal architecture,
though
• Advantages of FDR vs. TDR
• Excellent event resolution - no “dead-zone”
• Higher dynamic range - farther distance
• Can measure through multiple taps, splitters, etc.
![Page 31: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/31.jpg)
Page 32
FDR (cont.)• The reflection is such that the peaks of the individual
cycles can be translated to distance to the fault
(impedance mismatch) through the this equation:
• D= 492*Vop/f
• Where D = distance to fault in feet, 492 = speed of
light / 2 in million ft/sec, Vop = velocity of propagation
of the cable, and f = the separation between 2 peaks
of the standing wave in MHz
• The peak-to-peak value of the reflection determines
the magnitude of the fault and is calculated by:
• Return Loss (dB) = 20*log(Reflected Energy)
![Page 32: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/32.jpg)
Page 33
DROP CABLEDROP CABLE
TAP
FDR Identifies Mismatches• Measures opens, shorts and structural damage
to cable or home wiring passive devices
• Highly accurate distance to fault measurement
• Worst case faults are quickly pinpointed
![Page 33: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/33.jpg)
Page 34
Fault Locating
25-FeetRG59
Vop = 0.78
35-FeetRG59
Vop = 0.78
25-FeetRG59
Vop = 0.78
50-FeetRG59
Vop = 0.78
RS-232
75 Feet2-way splitter
Event #2Splitter75 feet
Event #3Unterminated Cable100 feet
Event #4
110 feet
Event #1Ground Block
50 feet
Unterminated Cable
Must have an idea of the internal architecture to understand the readout
![Page 34: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/34.jpg)
Page 35
Digital Signal Level Measurements
• Measures (Non-bursted) Digital
Signals
• User Selectable Bandwidth for
Accurate Power Measurements
• Quick Mode Measures Signals
Based on Bandwidth Estimation
/ Normalization Technique• Mode Measures
Digital Signals via Integrated Power Technique
![Page 35: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/35.jpg)
Page 36
Frequency
+2.5 MHz-2.5 MHz
0
2
4
6
8
10
12
471
471.
547
247
2.5
473
473.
547
447
4.5
475
475.
547
647
6.5
477
477.
547
847
8.5
479
IF Meas. BW = 280 kHz
+/- 140 kHz
0
Digital carrier under test (5 MHz BW) Non measured area based on
280 kHz step size within 5 MHz total BW
Measuring the Digital “Haystack”
![Page 36: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/36.jpg)
Page 37
Level Mode Full ScanQuick Scan
Measuring Signal Levels• Use Meter’s Signal Level or Scan Modes
• Go/No-Go limits simplify signal level testing
• Digital measurement option for measuring
average power of digital signals in level mode
![Page 37: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/37.jpg)
Page 38
Installation Check
• Provides installation status check of system levels at
drop according to FCC or custom limits
• Results viewed by individual channel or global pass /
fail
• Separate analog and digital limits
![Page 38: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/38.jpg)
Page 39
• Ingress
• Impulse Noise
• Power Supply Noise
• Common Path Distortion– Defective line terminators
– Bad caps
– Bad grounds
– Feed-through connectors
Testing for Ingress• Pass/Fail limits simplify test
• Measurements above the limit indicates a problem
• This measurement can be misleading unless you
know the filter width
![Page 39: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/39.jpg)
Page 40
Noise Reduction Techniques• Proper house grounding
• Common mode coiling
• Beads and torroids
• “Ghost busters”
• Drop isolators or matching transformers
![Page 40: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/40.jpg)
Page 41
Overview• Good drop line
• Integrated messenger (IM)
• Quality shielding
• Low attenuation & dc-loop resistance
• Passives
• Good shielding
• Proper isolation
• Adequate return loss / VSWR
• Voltage blocking capacitors
• Exhaustive testing before the “bean counters”
start selling!
![Page 41: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/41.jpg)
Page 42
Tips & Suggestions
• Aware “user base” (customers)
• Sometimes too much information is dangerous
• Pin connectors for larger cables
• Quality componentry and craftsmanship
• Selective frequency placement of services
• Better Carrier-to-Ingress (C/I)
• Creative usage and placement of filters & traps
• Protect your investment and buy windowed filters
• Find the problem and fix it!
• Constant monitoring and preventive maintenance
![Page 42: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/42.jpg)
Page 43
Conclusion
• Have contingency plans for everything
• Train employees and customers
• Obtain good customer relations and loyalty
• Try to be as non-intrusive as possible
• Utilize equipment that quickly characterizes and
separates real problems from minor events
![Page 43: Page 1 Subscriber Networks Randy Francis ACTERNA (800) 622-5515 randy.francis@acterna.com.](https://reader035.fdocuments.us/reader035/viewer/2022062404/5516cdb8550346fc4e8b4851/html5/thumbnails/43.jpg)
Page 44
Comments
• All comments and suggestions are sincerely
appreciated
• Check out the ACTERNA web page
WWW.ACTERNA.COM