SPECIFICATION Phase Locked Loop Module 1 of 2 Written by Checked by Approved by Customer Allwin Date May 13, 2003 Part No. NCPA7-1810 Specification No. 1. Housing 1.1 Circuit Hybrid Integrated Circuit 1.2 Programming LMX-2326(National Semiconductor) 1.3 Terminal SMD Type 1.4 Case Steel Ni Plating 1.5 Dimensions See Paragraph 3. 2. Electrical Characteristics ITEM UNIT MIN TYP MAX 2- 1 VCO Supply Voltage(Vcc) Vdc 4.75 5.00 5.25 2- 2 PLL Supply Voltage(Vcp) Vdc 4.75 5.00 5.25 2- 3 Operating Frequency Range MHz 1780.00 1810.00 1840.00 2- 4 Reference Frequency(Ref) Power Level(Rep) MHz dBm -10.0 10.00 +4.0 2- 5 Channel Step Size kHz 200 2- 6 Output Power Level dBm -3.0 0.0 +3.0 2- 7 Current Consumption mA 50 2- 8 2’nd Harmonic dBc -20 2- 9 Spurious Level dBc -65 2-10 Lock Time ms 5 2-11 Phase Noise(C/N) - at offset @100Hz - at offset @1kHz - at offset @10kHz - at offset @100kHz dBc/Hz -70 -75 -100 -120 -65 -70 -95 -115 2- 12 Operating Temp. Range °C -30 +80 2- 13 Output Impedance Ω 50

description

PA7-1810

Transcript of PA7-1810

Page 1: PA7-1810

SPECIFICATIONPhase Locked Loop Module 1 of 2

Written by

Checked by

Approved by

Customer

Allwin

Date

May 13, 2003

Part No.

NCPA7-1810

Specification No.

1. Housing1.1 Circuit Hybrid Integrated Circuit

1.2 Programming LMX-2326(National Semiconductor)

1.3 Terminal SMD Type

1.4 Case Steel Ni Plating

1.5 Dimensions See Paragraph 3.

2. Electrical Characteristics

ITEM UNIT MIN TYP MAX

2- 1 VCO Supply Voltage(Vcc) Vdc 4.75 5.00 5.25

2- 2 PLL Supply Voltage(Vcp) Vdc 4.75 5.00 5.25

2- 3 Operating Frequency Range MHz 1780.00 1810.00 1840.00

2- 4 Reference Frequency(Ref)

Power Level(Rep)

MHz

dBm -10.0

10.00

+4.0

2- 5 Channel Step Size kHz 200

2- 6 Output Power Level dBm -3.0 0.0 +3.0

2- 7 Current Consumption mA 50

2- 8 2’nd Harmonic dBc -20

2- 9 Spurious Level dBc -65

2-10 Lock Time ms 5

2-11 Phase Noise(C/N)

- at offset @100Hz

- at offset @1kHz

- at offset @10kHz

- at offset @100kHz

dBc/Hz

-70

-75

-100

-120

-65

-70

-95

-115

2- 12 Operating Temp. Range °C -30 +80

2- 13 Output Impedance Ω 50

ROSWIN CO., LTD.

Page 2: PA7-1810

SPECIFICATIONPhase Locked Loop Module 2of 2

Customer Date Part No.

NCPA7-

Specification No.

3. Dimensions

4. DUT

ROSWIN CO., LTD.