Pa-9 Power Analyzer V 1.0 1/14/2000. 2 OBJECTIVES Use The Latest Technology To Deliver Highest...

33
Pa-9 Power Analyzer V 1.0 1/14/2000

Transcript of Pa-9 Power Analyzer V 1.0 1/14/2000. 2 OBJECTIVES Use The Latest Technology To Deliver Highest...

  • Slide 1
  • Pa-9 Power Analyzer V 1.0 1/14/2000
  • Slide 2
  • 2 OBJECTIVES Use The Latest Technology To Deliver Highest Performance At Lowest Cost. One of the most powerful DSPs. Co-microprocessor. Low Cost Digital Camera Hi-Density Memory. Low Cost/High Performance Graphical Display. Delay Obsolescence. Worldwide Product.
  • Slide 3
  • 3 Result: pa-9 Power Analyzer Evolved from: 15 + Years Experience With Utilities Monitoring And Power Quality Measurement Needs Listening To Suggestions From Our 600+ Customers and Experience From Our Very Successful Products like the pa-7 Power Analyzer (1600 units installed). Our Goal: Extend To The Industrial Market Our Reputation Earned Through 15 Years of Service/Reliability To The Utility Market.
  • Slide 4
  • 4 Light Rugged polypropylene Case (12.5lbs or 5.7Kg) Lockable Hasps 5 Current Channels Optional Auxiliary AC Power Input (90-600vac/dc) 4 Voltage Channels Optional External RS232 Port Optional Modem
  • Slide 5
  • 5 KEY FEATURES Simplified Instruction Sheet Home Key Backlit Graphic Display Mouse Type Navigation System DB9 RS232 Port Real Time Display Key
  • Slide 6
  • 6 KEY FEATURES 4 V (Differential)/5 Current Channels Range: Voltage 600V AC or DC Current Based on CT Most Configurations Supported for Power Measurements Immediate Local Info on Graphical Display Powered from Phase A Voltage (90-600v AC,or 110-600v DC) FLASH PROM & Non-Volatile Data Memory 256/Cycle Sample Rate (TRMS through 63 rd Harmonic) Memory Up to 12 MB And Data Transfer Up to 115KB Sub-Cycle Event Capture to 65 Microsecond Events 3 Packages Portable, Wall Mount, Rack Mount
  • Slide 7
  • 7 KEY FEATURES 4 Simultaneous Recordings RMS (Long Term Trend) Out of Limits Log (for RMS Value) Waveform Power Flow Parameters
  • Slide 8
  • 8 RMS Recording Parameters to consider Sample Rate (Fixed at 256/cycle) Response Time (or Integration Time) User Settable To 1 cycle or longer. Cycle by Cycle Recording Possible. Storage Interval User Settable 1 To cycle 4 Hours. Save Min RMS, Max RMS, Overall RMS per Storage Interval. Technique Conserves Memory and Guarantees Capture of Lowest & Highest Signal Values per Storage Interval.
  • Slide 9
  • 9 Stored True RMS Voltage / Current Pa-9 can display: MIN, MAX, and TRMS values for all channels for entire test. (Press HOME, select Stored Data, RMS Interval) Trending graphs of any parameter right on pa-9. (ex. VA MIN trended over entire test) Ms-pa9W software Tabular Report (right) MIN, MAX, & RMS Reported at every storage interval. Data for trending graphs with scan line click and drag zooming (next)
  • Slide 10
  • 10 Notice the 5V dip (blue) when the large load turned on (red). Metrosonics pa-9 Scan Line, you can move to provide values in window
  • Slide 11
  • 11 Out-Of-Limits Log User Sets Following Limits By Channel High/Low RMS Limits (V & I) Sub-Cycle Impulse Magnitude. THD% Recorder Captures All Events Outside of User Preset Limits And Logs Them With Duration In Out-Of- Limits Log.
  • Slide 12
  • 12 Stored Data: Event / Out of Limits Data Out of Limits- While recording, continuously monitors for excedances of user defined limits for upper & lower V/I, sub- cycle (65uS), and THD. Monitors all connected channels, for analysis between load / source side. Large event memory up to 1,000 events! Exact reporting of MIN, MAX, and RMS during event timeframe. Reports events as short as 65uSeconds.
  • Slide 13
  • 13 Waveform Capture Waveforms Are Captured With Event Trigger Time Trigger Manual Trigger from Front Panel User Specifies Number of Pre-Trigger Cycles (Max 2) and Number of Post- Trigger Cycles (Max 99) To Capture.
  • Slide 14
  • 14 Waveform Display
  • Slide 15
  • 15 Ms-pa9W waveform chart triggered on loss of voltage. Metrosonics pa-9
  • Slide 16
  • 16 Applications for pa-9: Waveform Capture - Motor Inrush Waveform capture triggered on Rising Current Three phase chiller start-up inrush. Display all captured cycles on one screen. (Inrush decay envelop) Same click and drag zoom and scan line features.
  • Slide 17
  • 17 Demand Recording User Specifies Demand Interval, Fixed Or Sliding Window, Configuration (Wye, Delta etc). All Power Parameters Are Recorded (KW, KVAR, KVA, pf, dpf etc). Power Data Can Be Recorded As Fast As Every 6 Cycles (1 Cycle In Future).
  • Slide 18
  • 18 Stored Data: Demand Data (with power flow option) ms-pa9W Software allows: Printing and exporting of text data reported every storage interval Trending graphs with click and zoom capabilities Scan line reporting and vector diagrams (next)
  • Slide 19
  • 19 Demand Graph with scan line feature and vector diagram. Metrosonics pa-9
  • Slide 20
  • 20 Real Time Harmonic Analysis FFT Done Every 6 Cycles. Harmonic Analysis And Direction Of Harmonic Power Flow Presented On Display. Generally A Good Indicator Of Source of Harmonics
  • Slide 21
  • 21 Here we see we have nearly 75 Amps of Neutral Current, of which 45.9 Amps are comprised of the 3rd harmonic. (bar graph superimposed allows viewing to 63rd) Harmonic Analysis In Software
  • Slide 22
  • 22 Software 32-bit Software Package ms-pa9W Compatible with Win 95/98/NT Generates Graphs/Reports PQDIF Support Coming IEC Flicker (Coming)
  • Slide 23
  • 23 Future Software Enhancements (4Q2000) Harmonic Trending Total Demand Distortion (TDD%) Trending CBEMA Scatter Diagram Single Software Package for Multiple Models Report Generator
  • Slide 24
  • 24 Hardware: User Interface RS-232 serial communications (to 115 KBAUD) Graphical display: View real time and stored data (text and graphical) 4 MB base memory (expandable to 8 or 12MB) Large tactile keypad for easy operation even with gloves on.
  • Slide 25
  • 25 Hardware: Packaging Packaging: Rugged enclosure: High impact Smaller package (13x10x6) NEMA 4X Weatherproof Lockable hasps Protective handles on input connector side. Lightweight (15 lbs./ 6.8 Kg.) Wide temperature range (-20C to +50C)
  • Slide 26
  • 26 Hardware: Voltage Channels 4 Voltage Channels 150/600VAC + DC auto- ranging. Safety banana jack inputs Right angle prevents accidental pull out Unfused probes standard, fused probes optional. Resolution.1% full scale. Accuracy.25% rdg +.05% full scale.
  • Slide 27
  • 27 Hardware: Current Channels 5 Current Channels Resolution.1% Full Scale Accuracy.25% rdg +.05% range + probe accuracy. Current probes Cp-6000CE - 600/6000A Powered from pa-9!! 1% reading accuracy! 1000A, 100A, 20A CTs Avlbl Adapter cable mates most Metrosonics cts to pa-9 On-site CT Selection Directly From pa-9 Without Reprogramming.
  • Slide 28
  • 28 Hardware: Power Supply 90-600VAC or 110-600VDC Operation. Power From V(A channel) standard No separate regulated 120VAC power source required Optional (independent) AC power input. Optional DC power input. (+12VDC) Internal Sealed Lead Acid Battery. Outage ride through time 15 minutes. Non-Volatile Memory Data Retention. External Ground Lug.
  • Slide 29
  • 29 Summary: Unique Features No Other Single Instrument Combines The Following Features 9 Channels. Measure AC or DC Voltage. Simultaneously Record RMS/Power/Waveforms. Capture Events As Fast As 65 Microseconds. Capture 2 Pre-trigger Cycles & Many Post-trigger. 256 Sample/Cycle Rate + FFT Every Few Cycles. Trigger On Current As Well As Voltage. Measure Phase A Frequency. Display Direction of Harmonic Power Flow. Store 60 setups in the Recorder (Field Selectable). Power Off Phase A Voltage With ac OR dc Voltage. Wide Industrial Temperature Range. Portable, Wall Mount, Rack Mount Packaging.
  • Slide 30
  • 30 Key Front Panel Displays Store Up To 60 Field Selectable Setups. Select CTs In The Field View Event Log On Site
  • Slide 31
  • 31 Planned Developments Next Generation Software. Trend More Items (Harmonics, Freq.), State Compliance With Standards (CBEMA, IEEE 519, IEEE 1159). Networking for Fixed Units. Internet Connectivity. Expand Product Line. Keep Listening To Our Customers!
  • Slide 32
  • 32 Pa-9 Starter Kit Sk-pa9-01 - Starter kit includes includes: pa-9, w/ 12 MB internal memory pa-9-PF Power Flow Option ms-pa9W - 32 bit Windows software ca-pa9-11- kit of 4 (unfused) voltage cables with alligator clips and a set of neutral jumper cables ca-pa9 charging cable ca-rs232 - db9 communications cable (3) cp-6000CE 600/6000 Amp AEMC Flexible current probes (powered from pa-9) SC-PA9 soft sided carry case 1 Year Warranty
  • Slide 33
  • 33 Thank you for the opportunity of being Able to Show You The Capabilities of This Remarkable Instrument!! Have A Great Day