P9/10 SD Data Sheet P9/10 HV AC Series - ProMation … · 2015-12-04 · Use your smart phone...

4
50°F 10°C 75°F 24°C 100°F 38°C 125°F 52°C 150°F 65°C 25% 50% 75% 100% On/Off/Jog Proportional Ambient Temperature Duty cycle is defined as the ratio of total time vs. run time, and is a function of environmental conditions including ambient temperature, supply voltage and control signal stability Duty Cycle rating on all proportional control actuators is managed (75% maximum). Duty cycle graph 238703 C US ® SD15_P213_HV Ver N_100915 Page 1 of 4 P9/10 HV Series Electric actuators designed for load requirements ranging from 17500”lbs up to 22000”lbs. Each actuator comes standard with two auxiliary switches (Form C), an internal low power heater, a NEMA 4X environmental rating, and in 120vac and 230vac supply voltages. The P9/10 mechanical connections are ISO5211 compliant. The P9/10 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. Models can also be ordered with internal proportional control cards that accept a wide range of control signals and generate multiple feedback signals for field use. Data Sheet P9/10 HV AC Series On/Off/Jog/Proportional ISO5211 F16 R75 Also available in 3 phase supply. Separate spec sheets are available for these configurations. See www.promationei.com for more information or call ProMation Engineering. Note: Not all combinations are possible. Please consult factory. On/Off Proportional P 17500”lbs / 2000Nm 22000”lbs / 2500Nm Non-Spring Return 120 230 9 10 N NEMA 4X 4 120VAC+10% 230VAC+10% P 9 - 120 P N 4 Product Family Control Options Special Designations Voltage Options RO Relay Open (2 pos) RC Relay Close (2 pos) TS Torque Switch Actuator Specifications P9 P10 Torque “lb/Nm 17500”lbs/2000Nm 22000”lbs/2500Nm Supply Voltage 120vac 230vac 120vac 230vac Max Inrush Current 5.8A 3.8A 6.5A 4.0A Running Current 3.3A 2.1A 4.0A 2.3A Motor Split Phase Capacitor Runtime (90°@60Hz) 58 sec 58 sec Runtime (90 O @50Hz) 70 sec 70 sec Duty Cycle 25%, Proportional: Managed (75% maximum) Motor Starts 1200 per hour Weight 145lbs/66kg Mechanical Connections ISO5211 F16 Rnd 75mm Electrical Entry (2) 3/4” NPT Electrical Terminations 12-16ga Environmental Rating NEMA 4/4X Manual Override 15.6” Handwheel Control On/Off-Jog, Proportional Actuator Case material Aluminum Alloy, Powder coated Motor Protection 230°F/110°C Thermal F* Class *Totally Enclosed Non-Ventilated Motors Ambient Temperature Operating Range -22°F to +125°F -30°C to +52°C

Transcript of P9/10 SD Data Sheet P9/10 HV AC Series - ProMation … · 2015-12-04 · Use your smart phone...

Duty Cycle Graph

CSA Certified Duty Cycle Graph Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Ambient Temperature Ambient Temperature

CSA Certified Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Proportional

Ambient Temperature

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Proportional

Ambient Temperature

CSA Certified Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

On/Off/Jog / Proportional On/Off/Jog / Proportional

Ambient Temperature

50°F10°C

75°F24°C

100°F38°C

125°F52°C

25%

50%

75%

100%

Ambient Temperature

• Duty cycle is defi ned as the ratio of total time vs. run time, and is a function of environmental conditions including ambient temperature, supply voltage and control signal stability

• Duty Cycle rating on all proportional control actuators is managed (75% maximum).

Duty cycle graph

238703C US

®

SD

15_P213_H

V Ver N

_100915

Page 1 of 4 P9/10 HV Series

Electric actuators designed for load requirements ranging from 17500”lbs up to 22000”lbs. Each actuator comes standard with two auxiliary switches (Form C), an internal low power heater, a NEMA 4X environmental rating, and in 120vac and 230vac supply voltages. The P9/10 mechanical connections are ISO5211 compliant. The P9/10 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. Models can also be ordered with internal proportional control cards that accept a wide range of control signals and generate multiple feedback signals for field use.

Data Sheet

P9/10 HV AC SeriesOn/Off/Jog/Proportional

ISO5211 F16 R75

Also available in 3 phase supply. Separate spec sheets are available for these configurations.See www.promationei.com for more information or call ProMation Engineering.

Note: Not all combinations are possible. Please consult factory.

On/Off

ProportionalP

17500”lbs / 2000Nm

22000”lbs / 2500Nm

Non-SpringReturn

120

230

9

10

NNEMA

4X

4

120VAC+10%

230VAC+10%

P 9 - 120 P N 4Product Family Control Options Special DesignationsVoltage Options

RO Relay Open (2 pos)

RC Relay Close (2 pos)

TS Torque Switch

P9/10 SD

Actuator Specifi cations P9 P10Torque “lb/Nm 17500”lbs/2000Nm 22000”lbs/2500NmSupply Voltage 120vac 230vac 120vac 230vacMax Inrush Current 5.8A 3.8A 6.5A 4.0ARunning Current 3.3A 2.1A 4.0A 2.3AMotor Split Phase CapacitorRuntime (90°@60Hz) 58 sec 58 secRuntime (90O@50Hz) 70 sec 70 secDuty Cycle 25%, Proportional: Managed (75% maximum)Motor Starts 1200 per hourWeight 145lbs/66kgMechanical Connections ISO5211 F16 Rnd 75mmElectrical Entry (2) 3/4” NPTElectrical Terminations 12-16gaEnvironmental Rating NEMA 4/4XManual Override 15.6” HandwheelControl On/Off-Jog, ProportionalActuator Case material Aluminum Alloy, Powder coated

Motor Protection 230°F/110°C Thermal F* Class*Totally Enclosed Non-Ventilated Motors

Ambient Temperature Operating Range

-22°F to +125°F-30°C to +52°C

P Series Exploded View

Easily distinguishable yellow/red position

indicator

Worm Drive

Heavy Duty Drive Motor

Easily accessible switch &

cam stacks

Modular ControlCards

Clutchless OverrideHandwheel

Aluminum Casting4X Protection

Mechanical Stop Screws (2)

Epicyclic Gearing

Aluminum Casting4X Protection

NEMA 4Cover Seal

(Typical)

Application Notes:1. These actuators are to be mounted ONLY between a horizontal and upright position.2. When installing conduit, use proper techniques for entry into the actuator. Use drip loops to prevent

conduit condensate from entering the actuator. 3. Both NPT conduit ports MUST use proper equipment to protect the NEMA 4X integrity of the housing. 4. The anti-condensate heater is to be used in ALL applications. 5. Do not install or store the actuator outdoors or in humid environments without power to the heater.6. Use proper wire size to prevent actuator failure (see wire sizing chart). 7. Mechanical travel stops exist to prevent over-rotation for manual override only. They are not intended

to stop motor driven rotation.8. Do not parallel wire multiple actuators together without utilizing isolation relays! If this is your

intention, please contact ProMation Engineering for a multiple actuator parallel wiring diagram.

Switch Logic Map and Switch/Cam Arrangement

Term

inal

ID#

12

11

10

9

8

7

-5° 0°CW CCW

85°5° 90° 95°

SW3 CCW AUX(Factory Set - Adj)

SW4 CW AUX(Factory Set - Adj)}

}Closed Common

Open Common

}Used by Controller

Open

Not Closed

Closed

Not Open

Switch sequencing data is provided in the table below to show the change-of-state points during the rotation of the actuator from OPEN to CLOSED and back again. The red bar indicates when that terminal makes with it’s respective common.

SW1 and SW2 are set at the factory and should NOT be changed. The INCLUDED auxiliary switches SW3 & SW4 are for terminals 7 thru 12 and those setpoints may be modifi ed if need be. When so optioned, SW5 & SW6 auxiliary switches are initially set to function the same as auxiliary switches SW3 & SW4.

On/Off Switch/Cam arrangement shown

SD

15_P

213_

HV

Ver

N_1

0091

5

Page 2 of 4 P9/10 HV Series

P9/10 Series Dimensional DataP9/10 Series Views

(Typical)

1

1

2

2

A A

B B

Drawn By

Finish

Promation Engineering Inc.16138 Flight Path Drive

Brooksville, Fl 34604Phone: 352-544-8436Fax: 352-544-8439

This Document is the property of ProMation Engineering,Inc. Distribution of this document without the written

consent of the owner is Strictly forbidden. Failure to comply will incur a liability for Damages.

Checked By4/8/2015

P9~P12 Dim Data Rev.

F

NO SCALE Sheet Number: 1

Material

ProMation Engineering, Inc.KHL

KHL

2/10/2014

P9_12 F16 R75 DimData.idw

Created:

Last Checked:

Part No.

Dwg. Name

Dimensional Data for P9~P12 Actuators (w/ or w/o -TS)

Engineering Change NoticeChange Date Description Name

02.10.2014 New Document KHL

04.15.2014 Added tolerance on drive coupling data KHL

04.23.2014 Lengthened handwheel, edited drawing to include TS text KHL

07.14.2014 Corrected tolerance on 75mm Drive Coupling KHL

10.07.2014 Pushed output diameter dimension to three decimal places, added keyway dimension KHL

04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL

REVA

B

C

D

E

F

Dimensional Tolerances (Unless Otherwise Noted):X.X ± .3 [X.XX ± .01]

X.XX ± .13 [X.XXX ± .005]ALL TOLERANCE FEATURES IN mm

458 mm18.0 in 285 mm

11.2 in

402 mm15.8 in

262 mm10.3 in

398 mm15.7 in

220 mm8.7 in

552 mm21.7 in

Add 254mm

[10"] to allowfor coverremoval

165 mm6.5 inBHC

(4) M20x2.5

30mm1.2"

F16 ISO Flange75.00 mm

2.953 in

218 mm8.6 in

184 mm7.2 in

(2) 3/4" NPTEMT Entry

Drive Coupling Fabrication Data

12.00 mm.472 in

10.00 mm.394 in

75.00 - .13.00+ mm

2.953 - 0.0050.000+ in

100.00 mm3.937 inDepth

31.50 mm1.240 in KEY

12.00 mm.472 inKeyway

On/Off/Jog Control• Field Control Device may be relay contact,

Switch or Triac type. • Pilot device 10A MAX. Auxiliary switches are

rated 10A @ 250vac MAX. • Terminals 7-12 are dry type Form C. • Terminals accept 12-16ga solid/stranded wire.

Control Signal Inputs(selectable using program menu):0-10vdc, 1-5vdc, 2-10vdc, 4-20mA

Factory set with common isolated from ground. Ground reference is possible.

Signal Input Impedance Sensitivity

0-10vdc 140k ohms 50mV

1-5vdc 250k ohms 20mV

2-10vdc 140k ohms 40mV

4-20mA 250 ohms 80µA

Feedback Signal Output(Can be different than input):0-10vdc, 1-5vdc, 2-10vdc, 4-20mA

Max Load: 250 ohms

extensive data logging that provides full proportional control for all industrial applications. ModBus communications are also an option on this controller.

Full Proportional Control Featuring:

• Autocalibration• Programmable• High resolution• Alarm Outputs• Data logging• Simple User Interface• Field Selection Friendly• Thermal Management

Auxi l iary Signal Output(programmable):A larm Contacts a l low for signaling of 5 different fault conditions. 2 Position ControlContacts and capability for 2 position (only) override of the actuator.

Proportional Control

The Premium controller offers a full array of features - such as various control and feedback signals, alphanumeric readout, several fault indicators for operational diagnostics,

ProMation Premium Controller:

SAMPLE DIAGRAMRefer to the proper IOM for your actuator for the correct wiring diagram or visit www.promationei.com.

Wire sizing data is provided in the Wire Sizing Chart to assist in the selection of the proper wire size for ProMation P Series actuators using various wire sizes over distance. Please make sure to reference the correct voltage and do not exceed the indicated length of the wire run for each model.S

D15_P

213_HV

Ver N_100915

Page 3 of 4 P9/10 HV Series

P9~13 120N4

NOT OPEN*

OPEN COM*

OPEN*

NOT CLOSED*

CLOSED COM*

CLOSED*

RUN OPEN

OPEN PILOT*

RUN CLOSED

CLOSED PILOT*

NEUTRAL

HOT

12

11

10

9

8

7

120VACLINE IN

* CONNECTIONSOPTIONAL

FIELDCONTROL

DEVICE

GND Screw

M

SW3

SW4

THERMALSWITCH

AUXILIARYSWITCH

(STANDARD)

ALL SWITCHESSHOWN WITHACTUATOR IN

FULL OPENPOSITION

AUXILIARYSWITCH

(STANDARD)

GND

Direct MountHeater

E1E2

Actuator ships in fully closed position!

410-50100TL25-1800

120VAC DRIVE

MOTOR

Capacitor

6

5

4

3

2

1

J1

HEATER

SW1

SW2

J2

E1E2

J3

1

12

43

Items within dotted line located inside actuator housing

430-10100 Switch Card

AW

D-8

50

-54

10

1

Wiring Diagrams for P9/10 Series

P9/10 SD WD

Wire Sizing ChartMAX distance between Actuator

and Supply (feet)

Actuator/Voltage

P9120VAC

P9230VAC

P10120VAC

P10230VAC

5.8A 3.8A 6.5A 4.0A

16 - 655 - 62214 362 1058 323 100512 553 1618 494 153710 940 2751 839 26148 1404 4106 1252 3901

WireGage

Amps

Use your smart phone barcode scanner app here.

16138 Flight Path Drive Brooksville, FL 34604

Phone (352) 544-8436 Fax (352) 544-8439email: [email protected]

ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. Visit us at www.promationei.com or use the QR code below to link to the site.

PL SeriesLinear Drive

Up to 4400lbs down/up force and up to 100mm

(4”) stem travelFor globe valves, gate valves and linear travel devices. With override handwheel. Available with On/Off/Jog or Proportional

control for 24vac, 24vdc, 120vac & 230vac supplies.

P SeriesNon-Spring Return

55”lbs through 40,000”lbs.Quarter-Turn,

with Manual OverrideAvailable with On/Off/Jog or

Proportional control. For 12vac/dc, 24vac/dc, 120vac, 230vac, 230v/3 phase, 380v/3 phase &

460v/3phase supplies.

PA~PD Series Spring Return

445”lbs through 2300”lbs.Quarter-Turn, both with and w/o

manual override handwheel. Spring either CW or CCW.

Available with On/Off control for 24vac/dc and On/Off or

Proportional control for 120vac & 230vac supplies. Stepdown

for 3phase available.

PBU Battery Back-Up Systems

Provides powersuffi cient to drive P Series actuators

to fi eld-selectable fail-safe positions. For P Series & PL

Series actuators in On/Off and Proportional control modes.Available for 24/120/230vac

actuators. 120vac/230 vac supply.

ProMation Product Line

• Premium Proportional Controller Option. Converts 2 position to proportional control.

• Extended Duty Motor - 75% Duty Cycle.• Single Wire Control Relay (Internal) Units operate

NORMALLY CLOSED - ENERGIZE TO OPEN.• Single Wire Control Relay (Internal) Units operate

NORMALLY OPEN- ENERGIZE TO CLOSED.

• Mechanical Torque Switch Assembly. P2~P13 except P2/3 120/230PN4-AC series.

• IP68 Protection, tested to 0.7kgf/cm2 for 72 hours. P2~P8 only.• 0-45-90 degree rotation option. • 0-90-180 degree rotation option. P2~P8 only.• 0-180 degree rotation option. No Mid-point position is offered.

(On/Off only). P2~P8 only.• 1k ohm position feedback potentiometer.• 5k ohm position feedback potentiometer.• 10k ohm position feedback potentiometer.• 4-20mA feedback generator for On/Off/Jog actuators.• Auxiliary Switch set. Provides 3rd and 4th auxiliary switches

(Form C x 2).• Adjustable Timer, Dual Set Point Timer (Duration and

Frequency) (Contact factory for application assistance).

• Proportional Control Signal override capability (OPEN OR CLOSED). P2~P13 Series only.

• Integral Thermostat for Heater Control - turns on at 32°F, turns off at 50°F.

• Cold weather auxiliary heater option. Thermostatically controlled, On 32°F, Off at 50°F, auto reset, hermetically sealed, 120/230vac On/Off/Jog type actuators. 175W Internal Heater, 2A power consumption.

• Timer function which slows actuator rotation (cycle time) using an internally mounted octal timer. (Contact factory for application assistance). P2 - P13 series only.

• Chain wheel override for applications where an actuator is mounted some distance from the fl oor. (Use with LCS).

• Local Control Stations (LCS) ProMation LCSs are designed to be remotely located or directly mounted to the actuator. Proportional actuators will have different options than On/Off. Available in steel, stainless, or fi berglass enclosures.(See catalog for additional Local Control Selections).

• 3 Phase models with or without Motor Control Center.

• Optional SCADA and Modbus compatability.

• Epoxy coating for increased environmental protection.

• Nylon coating for increased environmental protection.

• Stainless Steel enclosure. P1~P6 Only.

AVAILABLE OPTIONS (Factory Installed)

SD

15_P

213_

HV

Ver

N_1

0091

5

Page 4 of 4 P9/10 HV Series