Sanuvox Technologies Inc, © 2019 All rights reserved. February 2020 EN v.1 Instruction Manual Photos illustrating products are non contractual. P900-GX PORTABLE UV AIR PURIFIER Residential Model IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT. Read and follow all instructions contained in this manual before using the product. Failure to comply with these instructions may result in personal injuries or damage to the unit or system. 1. Installation and servicing of air conditioning and related equipment can be hazardous due to systems pressure and electrical components. Only trained and qualified service personnel should install, repair or service equipment. 2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel. 3. When working on the unit or system, observe precautions in the literature, tags and labels attached to the unit or system, and all other safety precautions considered as best practices in the HVAC industry. 4. When applicable, local regulation may comprise more restrictive installation and/or certification requirements. The afore mentioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense. 5. Follow all the safety instructions outlined in this document and respect all local and national codes applicable. 6. Never expose eyes or skin to ultraviolet light from any source. Therefore, before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources (there may be more than one switch to disconnect). CAUTION: Electrical shock may cause personal injuries or possibly death. 7. UV rays may destroy certain types of filters (polymer or plastic); please keep the unit or system light away from shining directly on plastic. 8. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety glasses and gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves. 9. UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions. 10. Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s). 11. Most UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS unless specified otherwise. SAVE THESE INSTRUCTIONS Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ REGISTER YOUR WARRANTY ONLINE AT www.sanuvox.com

Transcript of P900-GX - Sanuvox · 2020. 2. 12. · The P900-GX is designed to purify up to 900 square feet,...

  • Sanuvox Technologies Inc, © 2019 All rights reserved. February 2020 EN v.1

    Instruction Manual

    Phot

    os il

    lust

    ratin

    g pr

    oduc

    ts a

    re n

    on c

    ontra

    ctua

    l.

    P900-GXPORTABLE UV AIR PURIFIER

    Residential Model

    IMPORTANT SAFETY INSTRUCTIONSREAD AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

    Read and follow all instructions contained in this manual before using the product. Failure to comply with these instructions may result in personal injuries or damage to the unit or system.

    1. Installation and servicing of air conditioning and related equipment can be hazardous due to systems pressure and electrical components. Only trained and qualified service personnel should install, repair or service equipment.

    2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.

    3. When working on the unit or system, observe precautions in the literature, tags and labels attached to the unit or system, and all other safety precautions considered as best practices in the HVAC industry.

    4. When applicable, local regulation may comprise more restrictive installation and/or certification requirements. The afore mentioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.

    5. Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

    6. Never expose eyes or skin to ultraviolet light from any source. Therefore, before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources (there may be more than one switch to disconnect).

    CAUTION: Electrical shock may cause personal injuries or possibly death.

    7. UV rays may destroy certain types of filters (polymer or plastic); please keep the unit or system light away from shining directly on plastic.

    8. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety glasses and gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

    9. UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions.

    10. Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

    11. Most UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS unless specified otherwise.

    SAVE THESE INSTRUCTIONS

    Installation Date: _______________ Installed by: _________________Installer Contact Info.: _________________________________________

    REGISTER YOUR WARRANTY

    ONLINE AT www.sanuvox.com

  • 2

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    TABLE OF CONTENTS

    IMPORTANT SAFETY INSTRUCTIONS 1TABLE OF CONTENTS 2ABOUT THE PRODUCT 3COMPONENTS 3 How it Works 3SETUP & INSTALLATION 4 What you will need 4 What’s included 4 Step by Step Setup & Installation 4 Step by Step Stand Installation 5 Step by Step Handle Installation 5OPERATION 6 How to Operate your Product 6 How to Read the Control Panel Display 6 Default Settings 6 How to Switch from Default to Timer Mode 6 Step by Step Adjust Fan Speed 7MAINTENANCE 7 How to Replace Lamp(s) 7 Step by Step Lamp Replacement 7 How to Clean your Product 9 Step by Step Inlet Filter Cleaning 9STORAGE 10ULTRAVIOLETS: UVV & UVC 10ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 10TROUBLESHOOTING 10 What you will need 10 Problems & Solutions Table 10 A. Step by Step Verification of Motor Wire Connection 11WARRANTY 12CUSTOMER SERVICE 12

  • A

    B

    C

    D

    A

    3

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    ABOUT THE PRODUCT

    Congratulations on the purchase of your new Sanuvox ultraviolet air purifier. Sanuvox UV air purifiers are the most advanced air purification systems available, having been proven to destroy up to 99.999% of biological and chemical contaminants that circulate throughout your home or facility. Sanuvox systems have been tested by the EPA (Environmental Protection Agency), the National Homeland Security Research Center, medical universities and independent third party laboratories.

    The P900-GX is designed to purify up to 900 square feet, destroying chemical and biological contaminants.The unit is designed for small homes and apartments, and can be used in commercial areas.

    For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

    COMPONENTS

    How it WorksContaminated air enters the P900-GX parallel to the UV ‘J’ lamp, thus increasing contact time with the UV energy. First, the air goes through an inlet filter that captures particles. After, the UVV oxidizing section of the lamp destroys chemicals and odors, the UVC germicidal section of the lamp destroys biological contaminants. Finally, the purifed air circulates through the home.

    A. Control Panel Display B. Handle Notch (for wall-mounting) C. Lamp Access Door D. Stand

  • 4

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    SETUP & INSTALLATION

    What you will needA utility knife to unpack all components and a Phillips No.2 screwdriver.

    CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

    What’s includedThe P900-GX with its UV lamp and a basic installation kit.

    The installation kit includes: a UV caution decal, a maintenance decal, a stand and an handle with its screw (1).

    Step by Step Setup & Installation

    1. Prepare the P900-GX for installation. Remove unit from packaging. Before plugging the P900-GX, turn it face down and place on soft surface to protect top.

    STEP 1

    2. Install stand or handle. See Stand and Handle Installation instructions on page 5.

    3. Replace the P900-GX upright or on wall and plug the purifier in a wall outlet.

    You are now ready to power ON your new P900-GX and enjoy great air quality

    for you and your family.

    STEP 3

    STEP 2

  • 5

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    Step by Step Stand Installation

    Step by Step Handle Installation

    1. Loosen the two bottom screws between the two rubber feet.

    1. The handle fits into the wall/ handle notch just under the middle rubber foot. Slide the handle in and tighten the screw.

    2. Slide the stand through the two screws and tighten.

    STEP 1

    STEP 1

    STEP 2

  • A B C

    GED F

    6

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    OPERATION

    How to Operate your Product

    The P900-GX is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON and enjoy clean air in your home!

    CAUTION: The suggested operating temperature range is 10 to 50°C (50 to 122°F). Operating the P900-GX outside this range will result in decreased performance. For optimal performance, air temperature moving through the unit should be in the range of 15 to 20°C (60 to 70°F).

    How to Read the Control Panel Display

    The P900-GX control panel display will give you real time status update about its fan speed and timer settings.

    Default Settings

    When the unit is plugged, all settings are OFF: push the power button to turn on unit.Default fan speed is set to 3, which is considered the optimum performance.Default run time is set to “C” (continuous operation).The fan is always running when the lamp is on.

    CAUTION: System is designed to control the TDCEF-05019A12-H-12-BAL 12 Volt brushless DC fan motor. Operation with other types of fan may not be optimal and may void the warranty.

    You can then select the P900-GX fan speed and operating time at any time to suit your individual preferences.During operation, the LEDs and display toggle every 5 seconds between TIME and FAN setting display, showing time remaining and fan speed.

    Operation will resume at default time/speed whenever unit is turned off and on again.

    How to Switch from Default to Timer Mode

    1. While the P900-GX is powered ON, press the “Mode Button” to switch between settings. When “Timer Mode LED Indicator” flashes, your unit is on “Timer Mode” settings and the numeric digit on the “LED Display Window” corresponds to the time left before shutting down.

    2. Use the up and down arrow buttons to select run time. Run time can be set between 1 to 9 hours or to “C” (Continuous operation).3. Wait for a short period without touching any buttons for P900-GX to register new settings. Your unit will then start working with

    the timer mode activated.

    After the set time has elapsed, lamp, fan and display will turn off.

    A. Up Arrow Button B. LED Display WindowC. Power ON/OFF ButtonD. Down Arrow ButtonE. Timer Mode LED IndicatorF. Fan Speed LED IndicatorG. Mode Button

  • 7

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    How to Adjust Fan Speed

    1. While the P900-GX is powered ON, press the “Mode Button” to switch between settings. When “Fan Speed LED Indicator” flashes, numeric digits on the “LED Display Window” corresponds to the unit fan speed.

    2. Use the up and down arrow buttons to select fan speed. Variable fan speeds can be set between 1 to 9 (low-high).

    MAINTENANCE

    How to Replace Lamp(s)

    Replacing lamp on the P900-GX is quick and easy. Simply turn off the power source, remove and dispose of old lamp, replace with new Sanuvox branded UV lamp, turn power source back on. See below for detailed step by step instructions.

    CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

    Step by Step Lamp Replacement

    1. Unplug P900-GX from wall outlet. Turn face down and place on soft surface to protect top of unit.

    CAUTION: Before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources.

    2. Remove the 4 screws from the lamp access door. Then remove lamp access door.

    NOTE: There is a micro switch / cut-off switch to cut power to the P900-GX when the lamp access door is removed.

    4. Press the lamp clamp to release the old lamp, and slowly remove the old lamp.

    3. Once the lamp access door is removed hold the old lamp by the ceramic socket and remove the white plug from the old lamp.

    STEP 1

    STEP 2

    STEP 4

    STEP 3

  • 8

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    STEP 5

    STEP 6

    STEP 7

    STEP 8

    STEP 9

    5. Prepare the UV lamp for installation. Remove lamp from packaging. Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve.

    6. Press the lamp clamp and insert the new lamp. Release lamp clamp to secure lamp in place.

    7. Holding the ceramic base, attach the plug to the new lamp. The plug will fit in one direction only. It may be necessary to rotate the plug 90° to attach it.

    8. Replace the lamp access door and secure it with its 4 screws.

    9. Replace the P900-GX upright or on wall and plug the purifier in a wall outlet.

  • 9

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    How to Clean your Product

    For optimal performance, the lamp(s) and filter(s) should be kept free of dust and residue deposit. Clean when necessary with mild soap or alcohol. To clean the unit exterior, use a damp cloth with general purpose detergent. Always spot test the cleaner to make sure it does not damage the surface.

    CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

    1. Detach the two thumbscrews on the top of the filter frame with a non-magnetic 5/16" nutdriver. Then, remove the filter frame.

    3. Remove the aluminum filter and clean it.

    NOTE: The filter can be washed in a mild detergent, soap and water.

    5. Replace the plastic grill.

    2. Remove the plastic inlet grill.

    4. When filter is dry, reinstall it on the inlet posts.

    6. Replace the filter frame. Reattach the thumbscrews: place them with your finger and tighten them with the nutdriver.

    STEP 1

    STEP 3

    STEP 5

    STEP 2

    STEP 4

    STEP 6

    Step by Step Inlet Filter Cleaning

  • 10

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    ULTRAVIOLETS: UVV & UVC

    The UVC (254 nm) and UVV (185 nm) light produced by Sanuvox UV units and systems are the same two UV wavelengths produced by the Sun. The UVC wavelength attacks the micro-organisms on a molecular level deactivating and destroying the contaminants, while the UVV wavelength degrades the chemicals and odors. Unlike conventional UV lamps on the market, Sanuvox UV units and systems use a patented process designed to deliver the maximum UV dosage to the moving air-stream or surface.

    CAUTION: Never expose eyes or skin to ultraviolet light from any source.

    STORAGE

    The P900-GX does not require specific storage. It is a portable unit that works continuously when ON, or automatically when selecting proper settings (fan speed and timer).

    CAUTION: Keep away from unsupervised children. This unit is not a toy.

    ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE

    The product is rated at 120V to 240V, and 50 Hz to 60 Hz.See product label to confirm power consumption of your specific unit or system.

    NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

    Problem Possible Cause SolutionUnit doesn’t come ON. - There is no power to the electrical

    outlet.- Make sure the power outlet is working.- Make sure the unit is plugged in to 120V outlet.

    - The On/Off switch is not ON. - Push the ON button on the display.- The power cord is damaged. - Replace power cord.- The micro switch / cut-off switch is not well engaged.

    - Make sure the lamp door is well closed.

    - Make sure the lamp door pin pushes on the micro switch / cut-off switch.

    Unit comes ON, but lamp is OFF: its “glow” isn’t visible throught the oulet louver.

    - Lamp and/or ballast are defective. - Get a genuine replacement lamp and/or ballast.

    - Replace lamp and/or ballast.Unit comes ON and lamp is ON, but the motor is not turning or is making rattling noise.

    - Motor is defective. - Replace motor.- Motor wire connection is not properly connected.

    - Check motor wire connection. See Verification of Motor Wire Connection instructions on page 11 (A).

    Contact your contractor for all your needs in terms of replacement parts: power cord, control panel display, UV lamp, ballast, filter, grill, fan motor, stand, handle, etc.

    TROUBLESHOOTING

    If your product is not working properly, refer to the following.

    What you will needA Phillips No. 2 screwdriver, a non-magnetic 5/16" nutdriver and spare parts.

  • 11

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    A. Step by Step Verification of Motor Wire Connection

    1. Unplug P900-GX from wall outlet. Turn face down and place on soft surface to protect top of unit.

    CAUTION: Before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources.

    2. On the back of the P900-GX, unscrew the 8 screws along the sides (4 on the left, and 4 on the right) to open the unit.

    3. Once unscrewed, lift the cover to open the unit. Look at the top to see if the motor connection is properly connected.

    STEP 1

    STEP 2

    STEP 3

  • 12

    Instruction Manual for P900-GX

    1-888-726-8869www.sanuvox.com

    WARRANTY

    You should first read all instructions before attempting to use this product.For this warranty to be valid, keep a copy of the proof of purchase.

    UV lamp 3 yearsBallast 3 yearsElectronic components 3 years

    A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.

    SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

    Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

    B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.D. This warranty does not cover the filters, pre-filters, UV bulbs or other accessories (if included) except for material or workmanship defects.

    Call us toll-free at 1-888-726-8869 or email: [email protected] be sure to specify product name.NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

    CUSTOMER SERVICE

    TO ORDER REPLACEMENT PARTSPLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICEToll-Free Phone #: 1-888-726-8869Email: [email protected]: www.sanuvox.comPlease be sure to specify product name.

    Replacement parts for this productBST120/240GL Ballast with input of 120 to 230VLMPRGXJ65 T6 dual zone 6.5" UV ‘J’ lampMSCFTR7 Metal inlet filterMSCFTR8 Inlet grillMSCMTR8 Motor assembly

    WARNING: Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

    REGISTER YOUR WARRANTY

    ONLINE AT www.sanuvox.com