P-1210-DS-P602 Data Sheet of Hortriculture Pumps 2

download P-1210-DS-P602 Data Sheet of Hortriculture Pumps 2

of 2

Transcript of P-1210-DS-P602 Data Sheet of Hortriculture Pumps 2

  • 7/30/2019 P-1210-DS-P602 Data Sheet of Hortriculture Pumps 2

    1/2

    A

    Rev.

    HORTICULTURE SYSTEM PUMPS

    Sep. 24, 2012Issued for Review

    Prepared

    ZW IUS

    Checked ApprovedDescription Date

    Doc. No.: P1210-DS-P602 Sheet 1 of 2

    TA

    Doc. Title:

    TUWAIRQI STEEL MILLS LIMITED

    DATA SHEET OF

    HORTICULTURE SYSTEM PUMPS

    Rev. A

    DATA SHEET OF

    Date: Sep. 11, 2012

  • 7/30/2019 P-1210-DS-P602 Data Sheet of Hortriculture Pumps 2

    2/2

    Doc. Title. Prep./Chk By App. By IUS

    Rev. A Issue:

    Date Sheet

    1 As Built Data Filled By: Consultant Owner Contractor Vendor

    2

    3

    4 Pumps Qty. Motor Qty.

    5

    6 Engine Qty. Turbine Qty.

    7

    8

    9

    10 Liquid Proposal Curve N

    11 Normal Pumping Temp. (C) NPSHR (Water)

    12 Max. Pumping Temp. (C) Eff. BHP Rated (kW) 17.5 (VTC)

    13 Max. BHP rated IMP (kW)

    14 Max. Head Rated IMP (m)

    15 Viscosity @ PT. (cP) Min. Continuous (m/hr)

    16 Corr/Eros. Caused by Hyd. Power (kW) Rotation (Viewed from CPLG End)

    17 Outdoor Area: Shut off Head (m) (Max)

    18 Continuous Intermittent Random

    19

    20

    21

    22

    23 Bracket Vert. (Type)

    24

    25 barg @ C

    26 Gage

    27

    28 Between Bearings Overhung

    29

    30 Oil Mist

    31 Mfr.

    32 Pump Mfr. Driver Mfr.

    33

    34 Mfr. & Model

    35

    36

    37

    38 C.W. Pipe Plan CS SS Oth Tubing

    39

    40 Packing Cooling Injection Req'd: barg

    41 Seal Flush Piping Plan CS SS Oth Tubing

    42 External Seal Flush Fluid barg Bowl

    43 Auxiliary Seal Plan CS SS Oth Tubing Brg. Lube

    44 Aux. Seal Quench Fluid CS SS

    45

    46

    47 Volts/Phase/Cycles

    48 Lube Turbine

    49 Full Load Amps

    50 Cable Entries Temp. Rise Locked Rotor Amps

    51

    52

    53

    54

    55

    56

    57

    58

    59

    60 VTS - Vendor to Specify

    Enclosure Class I, Div.II IP-55 (Note-4)

    Sight F.I. Req'd

    Pressure Line Sham

    TEFC

    Float & Rod

    N/A

    Pump Sham

    Total m/hr

    Pipe

    Flinger

    Note

    VTC - Vendor to Confirm

    VTA - Vendor to Advise

    NOTES

    2. Suction & Discharge Line Size. Vendor to provide appropriate reducers & expanders.

    3. The rated flow of pump shall be 110% of Normal flow at the discharge head.

    4. Enclosure shall be according to Doc. No. 3822-MC-02S

    1. Vendor to confirm or advise as necessary.

    5. Pump drain sizes shall be provided by vendor

    Top T.Box

    Wit. Hydro

    Wit. NPSH

    Grease

    None

    VTA

    BRZ

    Pipe

    RPM

    Insulation Type F

    Siemens/ABB

    VTS

    DOWN

    Approx. Weight Pump & Base (kg)

    Pump thrust, kg.

    Oil

    MOTOR DRIVER (VTA)

    Power (kW)

    UP

    Float Switc

    B

    Cooling Type

    FrameVTS

    Bearings

    400V/3f/50Hz

    Mf

    Water

    Motor

    Impeller (s)

    Case SS 316

    Shop Inspection

    VERTICAL PUMPS (N/A)

    Brgs:

    Enclosed

    Flanged Threaded

    Pipe Line Sham:

    Line Sham

    Column Pipe:

    Open

    Other

    Sleeve

    Coupling

    Wear Ring

    Bearings

    Suction Strainer

    Running

    Packing: Mfr. & Type

    Total cooling water (m/hr)

    Bearings-type:

    Driver Mtd. By:

    Coupling:

    Mfr. Code

    Flood

    RF

    Safe

    Non-Wit. Hydro

    SHOP TESTS

    Non-Wit. Perf.

    Non-Wit. NPSH Req'd.

    Wit. Perf.

    60

    Mount:

    Lube: Ring Oil

    Radial

    Rated

    Thrust

    Impeller Dia. :

    Axial Rad; Volute Type:

    barg

    6" (Note-2)

    Max. Allow

    150#Discharge

    SS 316

    Hydro Test

    SGL

    MATERIALS (VTA)

    Diffuser

    1500 TDS

    Sp. Gr. at PT. 1

    Location:

    Vap. Press. at PT. (bara)

    40

    Diff. Press. (bar)

    Suct. Press.(barg)

    0.07

    Pit or Sump Depth (m)

    Min. Submergence Req'd. (m)

    6" (Note-2) 150#

    Model

    Dismant. & Insp. Amer Test

    Facing

    NPSHA (m)

    Indoor

    CONSTRUCTION

    Working:

    Location

    Hazardous

    Nozzles

    0.75

    Size (in)

    Rated

    Discharge Press. (barg

    Item Description

    Flow at PT. (m/hr)

    Serial No.

    PERFORMANCE (VTA)

    Note-3

    VTA

    4.50

    46

    Rated

    VTS

    8.0

    80 (VTC)0.00

    RPM

    Mtd ByProvided By

    -

    -

    Centrifugal -

    -

    -

    1

    0

    Item Description

    125

    Item No.

    OPERATING CONDITIONS

    Pump Mfr.

    RO Reject Water

    TA/ZW

    Issued for Review

    HORTICULTURE SYSTEM PUMPS

    Rating

    Case-mount: Centerline Foot

    Suction RF

    0

    Doc. No.:

    Provided By

    2 of 2

    Fo

    Tag No.

    Proposals

    Item No.

    PU-F66.4

    1

    VTA

    VTA

    Tuwairqi Steel Mills Limited

    DATA SHEET OF

    -0.50

    Mtd By

    Applicable To:

    Site TSML DRI Plant- Port Qasim, Karachi

    24-Sep-2012

    TUWAIRQI STEEL MILLS LIMITED

    30

    -

    Purchase

    DBL

    RO Rejected Water Supply To Green Lawns

    Vent

    P1210-DS-P602

    Total m/hr

    4.0

    Drain

    Size/No. of Rings

    AUXILIARY PIPING (AS APPLICABLE)

    Mech. Seal:

    14

    Service

    Max. Type:

    Type

    Split:

    Press:

    Connect:

    Diff. Head (m)