Oxygen sensor
Click here to load reader
Transcript of Oxygen sensor
![Page 1: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/1.jpg)
Oxygen sensor (2006-2012)
• Introduction
– Before the extinction level event in Japanese vacuum-technology-based manufacturing industries in 200X, the detection of trace amounts (e.g., 10-9, 10-12, 10-15, …) of oxygen had been gaining increasing attention.
– As the key device for in-situ monitoring trace levels of oxygen, one kind of sensor had been focused.
– Our R&D project was subsidized by the government and the company.
1
![Page 2: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/2.jpg)
Oxygen sensor (2006-2012)
• What’s new?
– Measuring procedure:
• To desorb oxygen from an n-type semiconductor surface by ultraviolet(UV) light irradiation.
• To adsorb oxygen onto the semiconductor surface
after turning the UV-light off.
• To measure electrical resistance of the n-type semiconductor surface.
2e.g., 1 sec
![Page 3: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/3.jpg)
Oxygen sensor (2006-2012)
• What’s new?
– Measuring procedure:
3
Interaction between oxygen and n-type semiconductor
Ec
Ev
NOMO(O2-)
![Page 4: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/4.jpg)
Oxygen sensor (2006-2012)
• What’s new?
– To use ultrathin film with the thickness being
– comparable
with polaron diameter:
( Large Low conc. O2 )
6 TiO6 units at PO2=10-20
5 TiO6 units at PO2=10-9
( Small High conc. O2 )
4
![Page 5: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/5.jpg)
Oxygen sensor (2006-2012)
• What’s new?
– To use ultrathin film with the thickness being comparable with polaron diameter:
5
Polaron diameter
Larger polaron diameter:Higher conductance(Lower resistance)
Smaller polaron diameter:Lower conductance(Higher resistance)
Film thickness
TiO6 unit cell
![Page 6: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/6.jpg)
Oxygen sensor (2006-2012)
• What’s new?– Hypothetical image:
Although SrTiO3 is
paraelectric,
near the surface of STO
adsorbed oxygen can (?)
induce the
ferroelectric-like
Ionic displacement.
6
O
Sr
Sr
O
O
Sr
Sr
O
Sr
Sr
O
O
O e
Ti
O
Ti
O
![Page 7: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/7.jpg)
Oxygen sensor (2006-2012)
• What’s new?
– Only paraelectric perovskites can show oxygen-concentration-sensitive electrical resistance.
7
![Page 8: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/8.jpg)
Oxygen sensor (2006-2012)
• Performance:
8
1.0E+08
1.0E+10
1.0E+12
1.0E+14
1.E-15 1.E-10 1.E-05 1.E+00
Res
ista
nce
(Ω)
Oxygen concentration ( PO2 / (PO2 + PHe) )
108
10010-15
1014
1012
1010
10-10 10-5
![Page 9: Oxygen sensor](https://reader038.fdocuments.us/reader038/viewer/2022100605/559cb8181a28abda558b45cd/html5/thumbnails/9.jpg)
Oxygen sensor (2006-2012)
9
http://toruhara.page.tl/2-.--Solid_Gas-Interface.htm