1 Aqua Control, Inc. 6A Wolfer Industrial Drive Spring Valley, IL 61362 Ph: 815.664.6400 800.377.0019 Fax: 815.664.4901 www.aquacontrol.com OWNER’S MANUAL Evolution Series Fountain 1/2 hp, 120V/60 Hz

Transcript of OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp,...

Page 1: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

1

Aqua Control, Inc.6A Wolfer Industrial DriveSpring Valley, IL 61362Ph: 815.664.6400 800.377.0019Fax: 815.664.4901www.aquacontrol.com

OWNER’S MANUAL

Evolution Series Fountain1/2 hp, 120V/60 Hz

Page 2: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

2

MOUNTING FASTENERS

MOUNTING BRACKETS

JUNCTION BOX(PLUGS INTO CONTROLSUPPLIED WITH FOUNTAIN)

LIGHTS

EV6-L-100 (INCLUDES 100 FOOT POWER CORD) EV6-L-175 (INCLUDES 175 FOOT POWER CORD)

NOZZLE

ARUM #EV6-N-0.50-ARUCLUSTER ARCH #EV6-N-0.50-CLAFLEUR DE LIS #EV6-N-0.50-FLESPIDER & ARCH #EV6-N-0.50-SARTIARA #EV6-N-0.50-TIA

FLOW STRAIGHTENER

MOUNTING FASTENERS

LIGHTING KIT NOZZLE KIT

OPTIONAL ACCESSORIES

SAFETY INSTRUCTIONS• The fountain must be connected to an individual branch circuit wired per the National Electrical Code (NEC) and

protected by the required time-delay fuses or circuit breaker. A two-wire, w/ground single phase 120V/60Hz 20 Amp circuit is required.

• The fountain is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the fountain safely. Young children should be supervised to ensure that they do not play with the fountain.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

• Before connecting the fountain check that the voltage indicated on the type plate corresponds to the mains voltage in your home.

• Under NO circumstances should anyone enter the water with the electrical equipment plugged in and/or in operation.

• NEVER run the unit out of water. It will damage the seals and create a dangerous situation for the operator.

• NEVER lift or drag the fountain by the power or light cord.

• The fountain suction screen should be inspected for clogging on a monthly basis. If matted weeds, leaves and plastic bags are present, remove them with a bristle brush. Failure to keep the suction screen clear of blockages will cause low water flow and cause the fountain motor to fail. This type of failure is NOT covered under the Aqua Control, Inc. warranty.

• In freezing conditions, the fountain must be removed from the water body and stored in an area above 32°F.

GENERAL INFORMATIONIf a manufacturing defect is encountered within two years, please contact your Aqua Control, Inc. distributor. If the distributor directs you to return the product, please carefully package the product in its original box and send with shipping and insurance pre-paid to the distributor. Upon receipt of the returned product, the distributor will inspect the item and determine the validity of the claim. If the provision of this warranty covers the item, the item will be repaired or replaced by Aqua Control, Inc. at no charge.

This limited warranty does not apply if the Evolution Series fountain is subject to negligence, abnormal use or operation, accident, improper operation, improper voltage or current, or damage by circumstances beyond Aqua Control’s means, including but not limited to fire, flood, freezing, or other external environmental forces. The limited warranty does not cover unauthorized alterations or repairs.

Aqua Control, Inc. or its distributors are not liable for electrician’s fees incurred for troubleshooting electrical issues.

WARNING - Risk of electric shock - This pump is supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

Page 3: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

3

STEP#4

STEP#5

ALIGN NOTCH IN FOUNTAIN WITH SLOTIN FLOAT AND INSERTFOUNTAIN

PLUG FOUNTAIN INTOCONTROL, PLUG CONTROLINTO 15 OR 20 AMP115 VOLT RECEPTACLESTEP#2

MEASURE AND CUTMOORING ROPESTIE TO FLOAT TIE MOORING LINES

TO ANCHORS

KEEPDRY

KEEP DRY

STEP#3PULL FOUNTAIN TO DESIRED LOCATIONIN POND. DRIVE IN MOORING STAKES.KEEP MOTOR AND LIGHTING CORDPLUGS DRY

MOORING ROPE

MOORING ROPEMOTOR CORD

TO CONTROL

SUBMERSIBLEMOTOR CORD

MOORINGANCHOR

STEP#1

THIS FACE TOWARDSFOUNTAIN

MOORINGANCHOR

QUICK STARTUP INSTRUCTIONS

Page 4: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

4

STEP#2

STEP#1

TRIPPER PINSSEE STEP#3

PLUG IN LIGHTS(OPTIONAL SOLD SEPERATELY)

PLUG CONTROLINTO STANDARDHOUSEHOLDOUTLET

PLUG IN FOUNTAIN

STEP#6

ONGREENFOUNTAIN

CONTROL

TESTING GROUNDFAULT INTERUPT(GFCI)

PUSH TOTEST

PUSH TORESET

STEP#4

OFFRED

SET CORRECTTIME-OF-DAY

STEP#7

STEP#3

STEP#5TURN ON CONTROL

SET ON/OFF TIMES(SEE TRIPPER PINS ABOVE)

Evolution Series Fountain1/2 HP, 115V, 60 Hz

FOUNTAIN CONTROL-TIMER PROGRAMMING

Page 5: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

5

OPTIONAL LIGHT PACKAGE INSTALLATION

SCRUBB WITHPLASTIC BRISTLE

BRUSH TO REMOVEDEBRIS.

SUCTIONSCREEN

PLUGGED SUCTION SCREEN

IF YOUR SUCTION SCREENBECOMES PLUGGED BY POND WEEDSOR OTHER DEBRIS.

UPPERBRACKETSLOT

LIGHTBRACKET

PLACE BRACKETIN SLOT

ROTATE BRACKET

SNAP BRACKETINTO LOWER FLOAT SLOT

OPTIONAL NOZZLE INSTALLATION

THROAT

REINFORCINGRING

NOZZLE

SCREWSINSERT SCREWS INNOZZLE FLANGEAND THREAD INTOTHROAT

FLANGE

INSERT FLOW STRAIGHTENERIN THROATREINFORCINGRING SIDE UP

FLOW STRAIGHTENER

SUBMERSIBLEJUNCTION

BOX

PLUG INTO FOUNTAINCONTROL

WASHERS

BRACKETNUT

MOUNT LIGHTSON BRACKETS

MAINTENANCE AND ACCESSORY INSTALLATION

CAUTION!! BEFORE YOU BEGIN, DISCONNECT FROM POWER (UNPLUG FROM CONTROL)

Page 6: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

6

REPLACEMENT PARTS LIST

9

13

14

1I

16

1G1H

15

10

12

11B11A

17A

17B

17C

1J

* OPTIONAL COMPONENTS NOT INCLUDED WITH UNIT.

2A

1B

3

1D

4

5

1F

8

1C

1E

1A

6A 6B

7A 7B

POND FOUNTAIN1/2 HP, 115V, 60HzEFFECTIVE 12/02/08

ITEM # PART # DESCRIPTION QTY

1 EV-H-KIT HARDWARE KIT (INCLUDES ITEMS 1A THRU 1J) 11A * EV-H-MSP-0.75 1/4-15 X 3/4 PAN HEAD HI-LOW SCREW 41B EV-H-HN-8 8MM HEX NUT 41C EV-H-LW-8 8MM LOCK WASHER 41D EV-H-HHB-2.50 1/4-20 X 2 1/2 HEX HEAD CAP SCREW 11E 80WL-0.25 1/4 LOCK WASHER 11F EV-H-MSP-0.75 1/4-20 X 3/4 PAN HEAD MACHINE SCREW 21G * EV-H-FW-5 5MM FLAT WASHER 81H * EV-H-LW-5 5MM LOCK WASHER 81I * EV-H-HN-5 5MM HEX NUT 81J * EV-H-MSF-4X16 4MM X 16 FLAT HEAD MACHINE SCREW 3

2 * NOZZLE KIT (INCLUDES NOZZLE, FLOW STRAIGHTENER & FASTENERS)2A * EV6-N-0.50-ARU 1/2HP ARUM NOZZLE KIT -2A * EV6-N-0.50-CLA 1/2HP CLUSTER ARCH NOZZLE KIT -2A * EV6-N-0.50-FLE 1/2HP FLEUR DI LIS NOZZLE KIT -2A * EV6-N-0.50-SAR 1/2HP SPIDER & ARCH NOZZLE KIT -2A * EV6-N-0.50-TIA 1/2HP TIARA NOZZLE KIT -3 EV-R-THROAT EVOLUTION THROAT 14 EV-H-FW-PROP PROPELLER WASHER 15 EV6-R-P-0.50 1/2HP PROPELLER 1

6 REPLACEMENT MOTOR OPTIONS6A EV6-A-M-0.50-100 1/2HP MOTOR WITH 100’ OF CORD AND MOLDED PLUG 16B EV6-A-M-0.50-175 1/2HP MOTOR WITH 175’ OF CORD AND MOLDED PLUG 1

7 MOTOR CORD OPTIONS (INCLUDES MOTOR LEADS, PINS, SPLICE KIT & MOLDED PLUG) MOTOR READY

7A EV6-R-MC-100 100’ MOTOR CORD 17B EV6-R-MC-175 175’ MOTOR CORD 1

8 EV-R-SCREEN EVOLUTION SUCTION SCREEN 19 EV-R-FLOAT EVOLUTION FLOAT 110 EV6-R-CB CONTROL BOX WITH 6’ CORD & MOLDED PLUG 1

11 LIGHTING CORD OPTIONS (INCLUDES SPLICE KIT & MOLDED PLUG)11A * EV6-R-LC-100 100’ LIGHT CORD 111B * EV6-R-LC-175 175’ LIGHT CORD 112 * EV-R-LJB LIGHT JUNCTION BOX WITH 6’ CORD & SPLICE KIT 113 EV-R-ROPE 100’ BLACK MOORING ROPE 114 EV-R-ANCHOR EVOLUTION MOORING STAKES 215 * EV-R-LGT-FIX LIGHT FIXTURE 115V WITH 6’ CORD & SPLICE KIT 416 * EV-R-LGT-BKT EVOLUTION LIGHT BRACKET 417 LIGHT FIXTURE COMPONENTS

17A * EV-R-LENS EVOLUTION CLEAR LENS FOR LIGHT 417B * EV-R-GASKET EVOLUTION LIGHT GASKET 417C * EV6-R-BLB-BLU BLUE LED LAMP 417C * EV6-R-BLB-WHC COOL WHITE LED LAMP 417C * EV6-R-BLB-WHW WARM WHITE LED LAMP 417C * EV6-R-BLB-YEL YELLOW LED LAMP 417C * EV6-R-BLB-GRE GREEN LED LAMP 417C * EV6-R-BLB-RED RED LED LAMP 4

Page 7: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

7

Trouble Check Possible solutionsFountain doesn’t work Not plugged in

GFCI circuit breaker tripped

Faulty motor or propeller jammed

Cord must be plugged into a 3-wire outlet that is protected by a Ground Fault Circuit Interrupter, or control box supplied with fountain.

Reset circuit breaker. If circuit breaker trips repeatedly, your electrical system may have a defect. Turn off circuit breaker and call an electrician to correct the problem.

Motor too hot and overload protection shut motor off. Let motor cool down.

Disconnect power, check and clear any debris in throat of fountain.

Fountain spray pattern smaller than before

Fountain intake clogged

Nozzle clogged

Disconnect power, check suction screen for debris

Disconnect power, remove nozzle cap, check for debris.

Fountain starts then stops GFCI circuit breaker tripping

Faulty motor or propeller jammed

Reset GFCI. If GFCI continues to trip repeatedly, your electrical system may have a defect. Turn off circuit breaker and call an electrician to correct the problem.

Motor too hot and overload protection shut motor off. Let motor cool down.

Disconnect power, check and clear any debris in throat of fountain.

EVOLUTION SERIES FOUNTAINTROUBLESHOOTING GUIDE

Page 8: OWNER’S MANUAL - ThePondOutlet.com€¦ · owner’s manual evolution series fountain 1/2 hp, 120v/60 hz. 2 mounting fasteners mounting brackets ... 4 ev-h-fw-prop propeller washer

8

AQUA CONTROL Evolution Series Fountain

Limited Warranty Aqua Control, Inc. warrants to the original purchaser (end user) of any Evolution Series Fountain manufactured by Aqua Control, Inc. that any part thereof which proves to be defective in materials or workmanship, as determined by the factory within two years from the purchase date, will be repaired or replaced at no charge with a new or remanufactured part, and returned freight prepaid. The end user shall assume all the responsibility and expense for removal, packaging, and freight to ship to Aqua Control to determine the warranty claim and for all reinstallation expenses.

The warranty is void in cases where damage results from: improper installation, operation with no flow, continued operation with only partial flow, continued operation with obstructions that result in pump cavitation (noisy operation), improper electrical connection, improper voltage, alteration, lightning, careless handling, misuse, abuse, freezing, disassembly of motor, or failure to follow main-tenance or operating instructions. Modification or repair by an unauthorized repair facility will void the warranty.

In no case will Aqua Control or its distributors accept responsibility for any costs incurred by the user during installation, removal, inspection, evaluation, repair, parts replacement, or for return freight. Nor will any liability be accepted for loss of use, loss of profits, loss of goodwill, for conse-quential damage, or for personal injuries to the purchaser or any person.

In the event of problems believed to be covered under warranty, it will be necessary to notify the distributor who will try to help resolve the problem and who may contact the factory for additional assistance. If it is concluded that there may be a defect which may be covered under warranty, it will be necessary to get a Return Material Authorization (RMA) from the distributor before shipment. Freight collect shipments will not be accepted by the factory on warranties or repairs.

The product or part(s) must be returned freight prepaid, to the factory, as directed, and in its original packaging or in a container which will prevent damage. Parts returned under warranty and damaged during shipping will not be covered under warranty for the shipping damage.

If the factory evaluation of the returned goods concludes that the failure is due to defects in materials or workmanship, the part or parts in question will be replaced under warranty with new parts, remanufactured parts, or will be repaired; at the factory’s option. The warranty period for all parts supplied under warranty will terminate at the end of the original product’s warranty. All warranty shipments from the factory will be shipped freight prepaid.

Warranty registration is HIGHLY recommended.

No implied warranties of any kind are made by Aqua Control, Inc. for its products, and no other warranties, whether expressed or implied, including implied warranties of merchantability and fitness for a particular purpose, shall apply. Should an Aqua Control product prove to be defective in materi-als or workmanship, the retail purchaser’s sole remedy shall be repair or replacement of the product as expressly provided above.

Aqua Control, Inc.6A Wolfer Industrial Dr. Spring Valley, IL 61362