OWNER: THIS PLAN IS ONLINE FOR REVIEW · P P EAVE EAVE 38'-0"V.I.F. #17571 SFR TILE ROOF SLOPE 6/12...

1
HIP HIP EAVE EAVE 38'-0"V.I.F. #17571 SFR TILE ROOF SLOPE 6/12 UNISTRUT RAIL (TYP) Strings Modules in series Vmp @ STCVoc @ STC Voc @ 0 °C Isc @ 70 °C DC KW @ STC DC KW @ 0 °C AC KW Inverter 1 3 13 382 478.40 519.06 8.58 8.93 9.89 8.00 SHEET NO: PUBLISHED: SHEET NAME: DRAWN: CHECKED: SB AG ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/0139P_Shamus_Pembrooke_FL.dwg REVISIONS: 01 SCALE: NTS (PICTURE SHOWS INSTALLATION WITH SIMILAR COMPONENT SPECIFICATIONS) SAMPLE INSTALLATION PHOTO 02 SCALE: N.T.S. PARCEL - (AHJ PROPERTY APPRAISER) INSTALLATION LOCATION I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL. 03 SCALE: 3/32" = 1'-0" ROOF LAYOUT PLAN - 39 PV MODULES 04 SCALE: VARIES SOLAR RACKING - UNIRAC TILE HOOK CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWN HERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THE ARRAY MAY NOT FIT AS PROJECTED. COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF OWNER: 17571 SW 7TH ST PEMBROKE PINES FL 33029-4207 SHAMUS,ERIC & JENNIFER L THIS PLAN IS ONLINE FOR REVIEW @ WWW.GEZELMANPE.COM/PV/0142P_CARLISH_MIAMI_FL.PDF CONTACT DESIGN TEAM @ WWW.SOLARDESIGNGROUP.US ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE FBC2007 W/09 SUPP. AND NATIONAL ELECTRICAL CODE. INSTALLATION OF A SOLAR ELECTRIC SYSTEM 17571 SW 7TH ST PEMBROKE PINES FL 33029-4207 ROOF MOUNT SPEED: 140 MPH EXPOSURE: C IP CATEGORY: II UPLIFT(PSF) : PZ1-32;PZ2-55.8;PZ3-82.5, LOAD < 4PSF ASCE PRESSURE ZONES: HTTP://UNIRAC.COM/PDF/II227.PDF CODE VERIFY INSTALLATION LOCATION AHJ: BROWARD COUNTY, PARCEL ID# 5140 19 03 6280 06 SCALE: NTS ELECTRICAL ONE LINE DIAGRAM & SPECIFICATION PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES: THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN AS STATED ON THE DRAWING. ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED. THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 5/16TH INCH DIAMETER CORROSION RESISTANT STEEL. THESE HOLD-DOWNS MAY BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOP CORD OF TRUSSES OR BLOCKING OR APPROVED ALTERNATE ANCHOR. APPROVED ALTERNATIVE ANCHORS INCLUDE: LAGS INTO TOP CORD OF TRUSSES OR BLOCKING (MIN 4”X4”X9”) J-BOLTS HOOKING TRUSSES OR BLOCKING ALL THREAD ROD THRU BLOCKING PRESSURE ZONE (PZ) #2 WIDTH IS 3-FT. PV ARRAY TO BE INSTALLED PRIMARILY WITHIN PZ1. MOUNTING RAILS SHALL BE ANCHORED INTO ROOF STRUCTURAL FRAMING AT CENTER-TO-CENTER DISTANCES NOT TO EXCEED PZ1 6-FT C-C; PZ2 4-FT C-C; PZ3 2-FT C-C. THERE SHALL BE TWO PIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED ON SHEET "E" OF THIS SUBMITTAL. THE PV MODULES MAY BE ORIENTED HORIZONTALLY OR VERTICALLY AT THE CONTRACTOR'S OPTION. ALL CONTRACTOR AC & DC WIRING SHALL USE MINIMUM 10 AWG COPPER OEM WIRING AND HARNESSES, REGARDLESS OF WIRE SIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS. PV-MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO SUNLIGHT. USE COMMON-SENSE & CAUTION WITH OPAQUE MATERIAL UNTIL ALL WIRING IS COMPLETED. TWISTED (WIRE NUT) CONNECTIONS ARE NOT PERMITTED FOR DC WIRING. USE OEM PLUG CONNECTOR HARNESS BETWEEN PV MODULES. MAKE SOLID MECHANICAL CONNECTIONS TO ENSURE ELECTRICAL CONDUCTIVITY BETWEEN ALL PV MODULE ENCLOSURES AND FRAMING MEMBERS WITH NO ELECTRICALLY ISOLATED COMPONENTS, USE #10 AWG BARE COPPER WITH SCREWED CONNECTIONS FOR BONDING JUMPERS AS NEEDED. OEM APPROVED BONDING/GROUNDING DEVICES ARE AN ACCEPTABLE SUBSTITUTE WHEN INSTALLED PER OEM INSTRUCTIONS. DO NOT LEAVE LOOSE, UNSECURED WIRES/HARNESS BETWEEN PV-MODULES, TIE TO THE MOUNTING RAILS WITH UV RESISTANT ZIP TIES, APPROVED WIRE CLIPS OR WIRING TROUGH IN NEAT, PROFESSIONAL MANNER. USE APPROVED MEANS AND METHODS PER NEC CURRENT IN THE JURISDICTION (AND ANY APPLICABLE STATE/LOCAL AHJ AMENDMENTS THERETO). ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS. ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND AS THE SYSTEM “AGES”. DESIGNED PER: ASCE 7-05, 2010 NEC, FBC2007 W/09 SUPP. INSTALLER/CONTRACTOR DENNIS MEE CORONADO SOLAR 3001 CEDORA TERR SEBRING FL 33870' PH. 863-381-6083 FAX 863-385-2406 CVC 56809 05 SCALE: NTS ELECTRICAL COMPONENT SPECIFICATIONS WIND UNIRAC UNIVERSIAL MOUNT HOLD DOWN HARDWARE UNIRAC UNIVERSIAL MOUNT INSTALLATION UNIRAC UNIVERSIAL MOUNT HOLD - SAMPLE PHOTO

Transcript of OWNER: THIS PLAN IS ONLINE FOR REVIEW · P P EAVE EAVE 38'-0"V.I.F. #17571 SFR TILE ROOF SLOPE 6/12...

Page 1: OWNER: THIS PLAN IS ONLINE FOR REVIEW · P P EAVE EAVE 38'-0"V.I.F. #17571 SFR TILE ROOF SLOPE 6/12 UNISTRUT RAIL (TYP) Strings Modules in series Vmp @ STC Voc @ STCVoc @ 0 °CIsc

HIPHIP

EAVE

EAVE

38'-0"V.I.F.

#17571 SFRTILE ROOF

SLOPE 6/12

UNISTRUT RAIL (TYP)

Strings Modules in series Vmp @ STCVoc @ STC Voc @ 0 °C Isc @ 70 °C DC KW @ STC DC KW @ 0 °C AC KW

Inverter 1 3 13 382 478.40 519.06 8.58 8.93 9.89 8.00

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

KA

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E

AC

CE

SS

ED

AT

: W

WW

.GE

ZE

LMA

NP

E.C

OM

/PV

/0

13

9P

_S

ha

mu

s_P

em

bro

ok

e_

FL.

dw

g

REVISIONS:

01SCALE: NTS (PICTURE SHOWS INSTALLATION WITH SIMILAR COMPONENT SPECIFICATIONS)

SAMPLE INSTALLATION PHOTO02

SCALE: N.T.S.

PARCEL - (AHJ PROPERTY APPRAISER)

INSTALLATION LOCATION

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATICDRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

03SCALE: 3/32" = 1'-0"

ROOF LAYOUT PLAN - 39 PV MODULES

04SCALE: VARIES

SOLAR RACKING - UNIRAC TILE HOOK

CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED.

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC

C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC

C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

OWNER:

17571 SW 7TH ST PEMBROKE PINES FL 33029-4207

SHAMUS,ERIC & JENNIFER L THIS PLAN IS ONLINE FOR REVIEW @

WWW.GEZELMANPE.COM/PV/0142P_CARLISH_MIAMI_FL.PDF

CO

NT

AC

T D

ES

IGN

TE

AM

@

WW

W.S

OLA

RD

ES

IGN

GR

OU

P.U

S

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE FBC2007

W/09 SUPP. AND NATIONALELECTRICAL CODE.

INS

TA

LLA

TIO

N O

F A

SO

LAR

ELE

CT

RIC

SY

ST

EM

17

57

1 S

W 7

TH

ST

PE

MB

RO

KE

PIN

ES

FL

33

02

9-4

20

7

RO

OF

MO

UN

T

SPEED: 140 MPH

EXPOSURE: C

IP CATEGORY: II

UPLIFT(PSF) : PZ1-32;PZ2-55.8;PZ3-82.5, LOAD < 4PSF

ASCE PRESSURE ZONES:

HTTP://UNIRAC.COM/PDF/II227.PDFCO

DE

VE

RIF

Y

INSTALLATION LOCATION

AHJ: BROWARD COUNTY, PARCEL ID# 5140 19 03 6280

06SCALE: NTS

ELECTRICAL ONE LINE DIAGRAM & SPECIFICATION

PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES:

THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING

JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN AS STATED ON THEDRAWING.ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THEPLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A

DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC

INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR

MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED. THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 5/16TH INCHDIAMETER CORROSION RESISTANT STEEL. THESE HOLD-DOWNS MAY BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOPCORD OF TRUSSES OR BLOCKING OR APPROVED ALTERNATE ANCHOR. APPROVED ALTERNATIVE ANCHORS INCLUDE:

• LAGS INTO TOP CORD OF TRUSSES OR BLOCKING (MIN 4”X4”X9”)• J-BOLTS HOOKING TRUSSES OR BLOCKING• ALL THREAD ROD THRU BLOCKING

PRESSURE ZONE (PZ) #2 WIDTH IS 3-FT. PV ARRAY TO BE INSTALLED PRIMARILY WITHIN PZ1. MOUNTING RAILS SHALL BEANCHORED INTO ROOF STRUCTURAL FRAMING AT CENTER-TO-CENTER DISTANCES NOT TO EXCEED PZ1 6-FT C-C; PZ2 4-FT C-C; PZ32-FT C-C. THERE SHALL BE TWO PIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. THE PV MODULES SHALL BE INSTALLED INTHE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED ON SHEET "E" OF THISSUBMITTAL. THE PV MODULES MAY BE ORIENTED HORIZONTALLY OR VERTICALLY AT THE CONTRACTOR'S OPTION.

ALL CONTRACTOR AC & DC WIRING SHALL USE MINIMUM 10 AWG COPPER OEM WIRING AND HARNESSES, REGARDLESS OF WIRESIZE, ARE ACCEPTABLE WHEN APPLIED TO THE OEM USE INTENDED, SUCH AS PV-MODULE TO PV-MODULE CONNECTIONS.

• PV-MODULES PRODUCE ELECTRICITY WHEN EXPOSED TO SUNLIGHT. USE COMMON-SENSE & CAUTION WITH OPAQUEMATERIAL UNTIL ALL WIRING IS COMPLETED.

• TWISTED (WIRE NUT) CONNECTIONS ARE NOT PERMITTED FOR DC WIRING. USE OEM PLUG CONNECTOR HARNESS BETWEENPV MODULES.

• MAKE SOLID MECHANICAL CONNECTIONS TO ENSURE ELECTRICAL CONDUCTIVITY BETWEEN ALL PV MODULE ENCLOSURESAND FRAMING MEMBERS WITH NO ELECTRICALLY ISOLATED COMPONENTS, USE #10 AWG BARE COPPER WITH SCREWED

CONNECTIONS FOR BONDING JUMPERS AS NEEDED. OEM APPROVED BONDING/GROUNDING DEVICES ARE AN ACCEPTABLESUBSTITUTE WHEN INSTALLED PER OEM INSTRUCTIONS.

• DO NOT LEAVE LOOSE, UNSECURED WIRES/HARNESS BETWEEN PV-MODULES, TIE TO THE MOUNTING RAILS WITH UVRESISTANT ZIP TIES, APPROVED WIRE CLIPS OR WIRING TROUGH IN NEAT, PROFESSIONAL MANNER.

• USE APPROVED MEANS AND METHODS PER NEC CURRENT IN THE JURISDICTION (AND ANY APPLICABLE STATE/LOCAL AHJ

AMENDMENTS THERETO).

• ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS.

• ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OFINSTALLATION AND AS THE SYSTEM “AGES”.

DESIGNED PER: ASCE 7-05, 2010 NEC,FBC2007 W/09 SUPP.

INSTALLER/CONTRACTOR

DENNIS MEECORONADO SOLAR

3001 CEDORA TERRSEBRING FL 33870'

PH. 863-381-6083FAX 863-385-2406

CVC 56809

05SCALE: NTS

ELECTRICAL COMPONENT SPECIFICATIONS

WIN

D

UNIRAC UNIVERSIAL MOUNT HOLD DOWN HARDWARE

UNIRAC UNIVERSIAL MOUNT INSTALLATION

UNIRAC UNIVERSIAL MOUNT HOLD - SAMPLE PHOTO

Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot
Siggi
Text Box
THIS DESIGN AND ANCHORAGE TO THE STRUCTURE MEETS THE REQUIREMENTS OF THE 2007 FLORIDA BUILDING CODE CHAPTER 16 STRUCTURAL AND CHAPTER 15 FOR WATERPROOFING.
Siggi
Text Box
1
Siggi
Text Box
REVIEW COMMENT
Siggi
Text Box
8/11/11
Siggi
Cloud
REV 1
Siggi
Polygon
Siggi
Text Box
1