Over Voltage Category III Power Supplies Giacomo Mazzullo
BDM – MEAN WELL EUROPE BV
Agenda
• Lighting Types
• Lighting Waveforms
• Over Voltage Category Definition
• Testing Table
• Impulse vs Withstand
• OVC III Applications
• MW Products meeting OVC III
• Modified products to meet OVC III
• 61558 and OVC III
• OVC III and Altitude
• How to use OVC II PSU in OVC III Applications
• Conclusions
Lighting Types
Lighting Waveforms
Lighting Waveforms
Over Voltage Category Definition in Power Supplies
Over Voltage Category Definition
OVC III Equipment is downward compatible with OVC II, I
application and environment.
Over Voltage Category Definition
I. Equipment of Overvoltage Category I (OVC I) is equipment for connection to circuits in which
measures are taken to limit transient or short duration overvoltage to an appropriately low level.
• The typical application is equipment containing electronic circuits protected to this level.
II. Equipment of Overvoltage Category II (OVC II) is energy-consuming equipment to be supplied
from the fixed installation.
• The typical application is appliances, portable tools and other household similar loads.
III. Equipment of Overvoltage Category III (OVC III) is equipment in fixed installations and for cases
where the reliability and the availability of the equipment is subject to special requirements.
• The typical application is switch(es) in the fixed installation and equipment for industrial
use with permanent connection to the fixed installation.
IV. Equipment of Overvoltage Category IV (OVC IV) is for use at the origin of the installation.
• The typical application is electricity meter(s) and primary overcurrent protection
equipment.
Voltage line to neutral derived from
nominal voltage AC or DC up to and
including (V)
Rated impulse voltage (V)
Overvoltage category
I II III IV
50 330 500 800 1500
100 500 800 1500 2500
150 800 1500 2500 4000
300 1500 2500 4000 6000
600 2500 4000 6000 8000
1000 4000 6000 8000 12000
Table 1 shows only the level for basic insulation.
In case the power supply is designed to double or reinforced insulation,
the voltage should consider one level higher.
For example:
For unit operating at 300Vac• OVC II is tested @ 2500V for basic and 4000 for double (SELV)
Over Voltage Category Testing Table
OVC Impluse voltage from table is the Peak Value
Withstand voltage is RMS value
The peak of withstand voltage is √2 x VRMS = 1.414 x VRMS
Withstand voltage test is 1 min continous -> Withstand voltage test is tougher than impluse voltage test!
Impulse vs Withstand
OVC III and Altitude
Some robot controller products to meet the
IEC60204-1 standard need an additional AC transformer in series between the power grid and power supply
OVC III Applications
Name
IEC/EN50178 Electronic equipment for use in power installations
IEC 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 62103 Electronic equipment for use in power installations (replaced by IEC 62477-1)
IEC/EN62477-1 Safety requirements for power electronic converter systems and equipment - Part 1: General
OVC III is equipment in fixed installations and
for cases where the reliability and the
availability of the equipment is subject to
special requirements.
The typical application is switch(es) in the fixed installation
and equipment for industrial use
with permanent connection to the fixed installation.
OVC III Applications
• With EN61558 certificate:
• LRS-35/50/75/100/150/150F• RSP-75/100/150
• HDR-15/30/60/100• KNX-20E
• OWA series• UHP-200/350 with design refer to 61558
MW Products meeting OVC III
Only Medical(EN60601) OVC II product has chance to meet OVC III of 61558.
60950 (OVC II)
61347 (OVC II)60335 (OVC II)
Modified products to meet OVC III
Next version (third edition) of IEC 61558-1 will clearly specify the OVC
test difference among categories to improve the information provide by current release of standard.
IEC 61558-1: 2005 + AMD1: 2009
61558 and OVC III
New product for industrial
application will have it (at least design refer to)
PSU with 61558 OVC III <= 2000m<2000m then downgrade to OVC II
Although the product has reserved the enough clearance distance for 5000m
(1.48 factor larger than 2000m one), but the product also needs to be
subjected to the corresponding impulse voltage test according to IEC61558.
Impulse test of unit is done at 6KV(double insulation) for up to 2000m
>2000m there is not defined in the standard.
So move back to OVCII where the test voltage is 4KV(double insulation)
Then 5000m should be tested 4 x 1.48 = 5.92KV -> NO problem!!
OVC III and Altitude
How to use OVC II PSU in OVC III Applications
How to use OVC II PSU in OVC III Applications
• Power Supply in the market generally refer to OVC II
• If a PSU comply with EN61558 certificate (or design refer to), we can be sure it
is a OVC III unit
• OVC III PSU can be used in OVC II & I application
• MEAN WELL support its customers with PSUs designed to support OVC III
• Where to find OVC info?
• Check the spec about the OVC III or 61558
Conclusions