OUTDOOR HEAT PUMPS - Way Mill Pools heat pumps are manufactured to suit a large variety of...

4
For efficient swimming pool heating Fully automatic Quiet in operation Requires very little regular maintenance No fumes Kind to the environment Economical to run FEATURES R OUTDOOR HEAT PUMPS

Transcript of OUTDOOR HEAT PUMPS - Way Mill Pools heat pumps are manufactured to suit a large variety of...

For efficient swimming pool heating

n Fully automatic

n Quiet in operation

n Requires very little regular maintenance

n No fumes

n Kind to the environment

n Economical to run

F E A T U R E S

R

OUTDOORHEAT PUMPS

OUTDOOR HEAT PUMPS

Outdoor Heat PumpsThe diagram above illustrates the way in which a heat

pump transfers and upgrades heat form the outside air to

the pool water. The heat pump technology offers an

extremely efficient method of pool water heating which

does not rely upon the sunshine, just air!

Calorex heat pumps are manufactured to suit a large variety

of applications. The ‘Ambient’ range will heat the pool

water throughout a typical UK summer season, operating

when the outside temperature is above 7 degrees centigrade.

Models 631-1531 incorporate an internal by-pass facility.

The ‘10X’ range, with a more comprehensive design, offers

an extended season usage. This model continues to operate

even when the outside air temperature is as low as zero

degrees centigrade. The ‘10X’ range also incorporates an

internal by-pass system which allows for a range of pool

water flow rates.

The ‘Y’ range is similar to the ‘10X’ model, but will still

operate when the outside temperature drops to -15 degrees

centigrade thus offering 12 months usage. This range

provides efficient All-year heating for both indoor and

outdoor pools.

QualityCalorex units are built to last and have been supplied to the

swimming pool industry for decades. Thousands of Calorex

units have been successfully operating in some thirty

countries. The choice of materials for the components is

aimed at a long reliable life. The cabinets are steel, first

galvanised and then plastic coated to provide resilient

protection against external elements. Pool water heat

exchangers are of high quality to ensure maximum

resistance to pool chemical corrosion. Models 631-1531

include a titanim heat exchanger with a five year warranty.

Each unit is thoroughly tested and inspected and must meet

a precise performance standard before leaving the factory!

The Calorex factory and products are approved to several

internationally accepted standards of quality and safety. All

Calorex equipment is fully guaranteed and dispatched

complete with comprehensive instructions.

Free Heat From The Air

5:1 4.5:1 4:1 3.5:1

Total heat to pool divided by energy consumed = Co-efficient of Performance (COP)

Free HeatFromThe Air

Free units of heat

Paid units of heat

total units ofheat to pool(COP)

HEATING SEQUENCE

OUTSIDE AIR

FAN EVAPORATOR (Heat Collector)

EXPANSION VALVE

COMPRESSOR

CONDENSER(Heat transferred to pool water)

HEATED POOL WATER

WATER FROM POOL

FILTER PUMP

POOL

SCHEMATIC ILLUSTRATION

Wid

th

Dep

th

Hei

ght

Electrical Data

65 1902.9-6.820 50-15021.8 5.2

AW510ALX Model 510X Single PH 20

68 56950

69

56

AW320AM 4.6

10.3

10.3

13.8

13.8

17.5

17.5

24

37

0.9

2.0

2.0

2.7

2.7

3.5

3.5

4.5

9.1

13.4

7

12

7

16

8

21

10

11

25

33

10 16

20

10

25

13

30

15

18

35

4.6

1.1

1.1

1.0

1.0

2.0

2.0

2.0

4.5

3.9

55

49

49

50

50

52

52

55

69

79

126

126

134

134

144

144

158

393

Model 320 Single PH

Model 631 Single PH

Model 631 Three PH

Model 831 Single PH

Model 831 Three PH

Model 1231 Single PH

Model 1231 Three PH

Model 1531 Three PH

Model 3020 Three PH

Model 7020 Three PH

AW631AM

AW631BM

AW831AM

AW831BM

AW1231AM

AW1231BM

AW1531B

AW3020B

AW7020B

8.0

8.0

11.2

11.2

12.8

12.8

16.8

16.8

2.0

2.0

2.5

2.5

2.8

2.8

4.0

3.8

13

5

11

6

15

7

21

9

13

10

20

10

25

10

30

15

50-150

50-150

50-150

50-150

50-150

50-150

50-150

50-150

130

92-138

92-138

92-138

92-138

128-192

128-192

128-192

66

2.0-3.0

2.0-3.0

2.2-4.5

2.2-4.5

3.0-7.8

3.0-7.8

2.9-6.8

2.9-6.8

55

55

55

55

55

55

60

60

9817151227

567

567

792

792

792

792

1227

1227

615

615

715

715

715

715

715

715

647

647

895

895

895

895

981

981

69

118

118

120

120

182

182

Model 510X Three PH

Model 710X Single PH

Model 710X Three PH

Model 910X Single PH

Model 910X Three PH

Model 1210X Single PH

Model 1210X Three PH

Model 1510X Three PH

AW510BLX

AW710ALX

AW710BLX

AW910ALX

AW910BLX

AW1210ALXS

AW1210BLX

AW1510BLX

PRO

DU

CTCO

DE

Hea

tto

Pool

(kW

)

Pow

erCo

nsum

ed(k

W)

Supp

lyCa

paci

ty(A

mp)

Supp

lyFu

se(A

mp)

Dimensions (mm)

1212

817

1075

1075

1075

1075

1075

1075

1180

1700

1950

605

485

485

485

485

485

485

485

1090

1340

640

1255

1255

1255

1255

1355

1355

1355

1212

Pool

Wat

erFl

owRa

te(l/

m)

Pres

sure

Dro

p(m

head

)*

Noi

seLe

vel@

3m(d

BA

)

Unp

acke

dW

eigh

t(kg

)

Hea

tPum

pTy

pe

UK

Seas

on

AM

BIE

NT

AIR

DEF

ROST

SUM

MER

POO

LH

EATI

NG

BY-

PASS

DEF

ROST

EXTE

ND

EDSU

MM

ERPO

OL

HEA

TIN

G

68 5843.950 13056 13.4

AW710ALY Model 710Y Single PH 20 12111.2

11.2

12.8

12.8

16.8

16.8

21.8

37

2.5

2.5

2.8

2.8

4.0

4.0

5.2

9.1

11

6

15

7

21

9

13

25

33

10

25

10

35

15

20

35

50-150

50-150

50-150

50-150

50-150

50-150

122750-150

66

2.2-4.5

2.2-4.5

3.0-7.8

3.0-7.8

2.9-6.8

2.9-6.8

2.9-6.8

4.5

55

55

55

55

60

60

65

69

121213401950

792

792

792

792

1227

1227

1700

715

715

715

715

715

715

715

1090

895

895

895

895

981

981

981

1212

121

125

125

187

187

194

399

Model 710Y Three PH

Model 910Y Single PH

Model 910Y Three PH

Model 1210Y Single PH

Model 1210Y Three PH

Model 1510Y Three PH

Model 3020Y Three PH

Model 7020Y Three PH

AW710BLY

AW910ALY

AW910BLY

AW1210ALYS

AW1210BLY

AW1510BLY

AW3020BY

AW7020BY

REVE

RSE

CYCL

ED

EFRO

ST

ALL

YEA

RRO

UN

DPO

OL

HEA

TIN

G

PRODUCT DESCRIPTION

Calorex Air To Water Heat Pumps

A low cost swimming pool heater that

uses the latest heat pump technology to

extract free heat from the outside air.

SPECIFICATIONS

Notes: The minimum operating temperatures for the above are: 7OC Ambient air for ambient air defrost models0OC Ambient air for by-pass defrost type (10X) models-15OC Ambient air for reverse cycle defrost (Y) models

Heat to pool capacities shown relate to a 20OCair temperature

All models and are refrigerant charged with R407C.

* Minimum and maximum pressure drops indicated for ‘10X’ and ‘Y’ range units.

If you should require further technical information please do not hesitate to contact us.

NATIONALACCREDITATION

OF CERTIFICATIONBODIES

CERTIFICATE REGISTRATION NUMBER 7660

ISO 9002REGISTERED COMPANY

01.06.07

10 20 30 40 50 60 70 80 90 100

24

25

26

27

28

29

30

31

32

33

74

76

78

80

82

84

86

88

90

92

100 200 300 400 500 600 700 800 900 1000 1100

Model320

Model631

Model831

Model1231

Model1531

(3 phase only)

Pool Surface Area ft2

Pool Surface Area m2

Wat

erte

mpe

ratu

reO

C

Wat

erte

mpe

ratu

reO

F

eg 42m2 pool @ 28oC requires a model 831

Graph A

May

-Sep

tem

berS

easo

n(a

ppro

x22

-24

wee

ks)

Sum

mer

Seas

on

Apr

il-O

ctob

erSe

ason

(app

rox

30-3

2w

eeks

)Su

mm

erPl

usSe

ason

Mar

ch-N

ovem

berS

easo

n(a

ppro

x38

-40

wee

ks)

Exte

nded

Sum

mer

Seas

on

10 20 30 40 50 60 70 80 90 100

24

25

26

27

28

29

30

31

32

33

74

76

78

80

82

84

86

88

90

92

100 200 300 400 500 600 700 800 900 1000 1100

Model 510X

Model 710X

Model 910X

Model 1210X

Model 1510X

Pool Surface Area ft2

Pool Surface Area m2

Wat

erte

mpe

ratu

reO

C

Wat

erte

mpe

ratu

reO

F

(3 phase only)

eg 450ft2 pool @ 84oF requires a model 1210X

Graph B

10 20 30 40 50 60 70 80 90 100

24

25

26

27

28

29

30

31

32

33

74

76

78

80

82

84

86

88

90

92

100 200 300 400 500 600 700 800 900 1000 1100

Model 510X

Model 710X

Model 910X

Model 1210X

Model 1510X

Pool Surface Area ft2

Pool Surface Area m2

Wat

erte

mpe

ratu

reO

C

Wat

erte

mpe

ratu

reO

F

(3 phase only)

eg 40m2 pool @ 82oF requires a model 1210X

Graph C

Note: The sizing graphs shown

on this page assume the

following UK conditions:

• Te entire pool is constructed

in-ground.

• Ground water level

is below pool construction.

• Floating heat retention

cover is used 20 hrs

per day.

• Average depth of water

@1.3 metres.

For sizing of equipment outside of

these design parameters please

consult the H & V design team.

Conversion Factor