Other systems – what needs to be done? Repair and reinstallation of other systems
description
Transcript of Other systems – what needs to be done? Repair and reinstallation of other systems
![Page 1: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/1.jpg)
Other systems – what needs to be done?
Repair and reinstallation of other systems
M.Solfaroli/B.Bellesia
Repair of 34Chamonix 2009
Acknowledgments: O.Aberle – F.Bertinelli – J.C.Billy - O.Capatina - J.Casas - L.Ceccone - S.Claudet J.Coupard - K.Dahlerup - R.Denz - K.Foraz - J.J.Gras - V.Parma - A.Perin – M.Poyer R.Shmidt - H.Thiesen – A.Vergara
![Page 2: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/2.jpg)
2Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
S34 activities
General activities
Repair of 34
![Page 3: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/3.jpg)
The new QDS system
3Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
See Reiner’s presentatio
n (sessi
on 04)
![Page 4: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/4.jpg)
The new valves
4Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Courtesy M. Kappinen, M. Duret
See Vittorio
’s presentatio
n (sessi
on 04)
![Page 5: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/5.jpg)
Jacks consolidation
5Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
See Ofelia’s p
resentation (s
ession 04)
![Page 6: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/6.jpg)
Stand Alone Magnets
6Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Improvement of level sensors in the stand alone magnet to increase the
reliability by installation of a flexible capillary with a bigger diameter and
without low pointSee Serge’s p
resentation (s
ession 01)
![Page 7: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/7.jpg)
DFBs
7Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Install electrical protections in
front of current leads
Improve the configuration of the safety valves discharge outlet
Install mechanical
protection for DFBM & DFBA
links
Install additional pressure
switches for the dry air system
See Katy+Julie
’s presentatio
n (sessi
on 05)
![Page 8: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/8.jpg)
Consolidation TL inox cages
Collimators
8Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Completion phase 1Full phase 1 system would be
installed for 2009, removing limits for b*, luminosity, cleaning
efficiency, protection and risks for collimator lifetime (early series
production)
Consolidation ring horizontal inox cages
Consolidation ring skew/vertical inox cages
See Katy+Julie
’s presentatio
n (sessi
on 05)
![Page 9: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/9.jpg)
9Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Incident related activities
Maintenance and Repairs
Repair of 34
S34 activities
![Page 10: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/10.jpg)
Racks re-installation
10Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
![Page 11: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/11.jpg)
PC 60A - problems
11Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
3 converters have required repairs:
• RCBH30.R3B2 (dead capacitor due to cold?)• RCBH24.R3B2 (Overvoltage through current lead voltage taps)• RCBV24.R3B1(Overvoltage through current lead voltage taps)
4 converters showed traces of oxidation (Cell 28).
Their DC connectors on DC cable side have to be changed
The other 87 converters have been fully re-tested and are operational
![Page 12: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/12.jpg)
PC 60A – re-commissioning
12Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Crates re-installation and re-connection when
magnets installation is finished
Re-testing:
PCC – PNO.a1 – PNO.d1
This activity is included in the powering test
![Page 13: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/13.jpg)
CRYO inst - problems
13Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
All systems have been tested
Only one card was blown out, most likely because of
a small piece of MLI creating an internal short
circuit
![Page 14: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/14.jpg)
CRYO inst - re-commissioning
14Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Visual inspection while interconnecting
Check of the signal cabling
Coherency tests
Crates re-installation and re-connection when
magnets installation is finished
![Page 15: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/15.jpg)
QPS racks - problems
15Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Quench Heater Power Supply
• Only QHPS in the D-area have been removed• Some of them have been analyzed and many have seen a
dielectric breakdown at the level of the input diode bridge for charging of the capacitor• No clear explanation (due to condensation inside?)• They can be easily repaired• Removal of the others depending on the situation
Quench Detector
• All of them have been removed• All at right of D-area have been
cleaned• Analysis to be done in all the others
![Page 16: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/16.jpg)
QPS racks - re-commissioning
16Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
IST
Heater Charging and Firing
This activity is considered as part of the powering test
Crates re-installation and re-connection when
magnets installation is finished
![Page 17: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/17.jpg)
Vacuum racks - problems
17Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
No problem was found
Electronics re-tested and operational
![Page 18: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/18.jpg)
Vacuum racks - re-commissioning
18Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Crates re-installation and re-connection when
magnets installation is finished
![Page 19: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/19.jpg)
Beam Instrumentation
19Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Beam Loss Monitor
Re-testing the whole sector (with radioactive
source)
Beam Position Monitor
Tests to be done during the interconnection
phase
BGI - BCT - BTV
• Already commissioned• Routine inspection
![Page 20: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/20.jpg)
20Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
PC - Short Circuit 24h runPower Converter
PO requested a check of the converters of the A34 to check whether they have been damaged by overcharge
(as for some 60A)
P3 P4
ARCPC
connected:• 3 x 13kA• 8 x 6kA• 25 x 600A
PC connected:
• 22 x 600ANo PC directly
connected
PC connected:
• 94 x 60A• 16 x
120A
DSLC
![Page 21: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/21.jpg)
21Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
PC - Short Circuit 24h run
PC (13kA – 6kA – 600A – 120A)
• Set-up of the short circuits at the level of the cables
• 24 hours heat run• Short circuit removal
(Short Circuit test in the UJ33 was performed at operational current
profile – sensitive area)
![Page 22: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/22.jpg)
22Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
S34 activities
Repair of 34
Incident related activities
Maintenance and Repairs
![Page 23: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/23.jpg)
Beam Instrumentation
23Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
BSRT (Synchrotron Light Telescope)
• Control cable being pulled• Upgrade of the alignment control engine of the
optic system• Change and regulation of the optic bench
• Not mandatory for operating the machine at 5TeV
• Feasibility on the LHC planning to be checked
RU.L4 removal (?)
Broken internal resistance
(manufacturing problem)
![Page 24: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/24.jpg)
The DSLC – problem
24Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
RQT12.R3B1
RQTL8.R3B1
RQTL9.R3B1
RQTL10.R3B1
RQTL11.R3B1
RSS.A34B1
ROD.A34B1
ROF.A34B1
RQTL7.R3B1
RQTL7.R3B2
RQS.A34B2
RQTL8.R3B2
RQT12.R3B2
RQT13.R3B2
RQTL9.R3B2
RQTL10.R3B2
RQTL11.R3B2
RSS.A34B2
ROD.A34B2
ROF.A34B2
RQS.R3B1
RQT13.R3B1
Cable layoutLayer 1 (inner) Wires 1-10:Layer 2: 11-26: Layer 3 (outer layer) 27-48:
5-6
3-4
7-8
9-10
11-12
13-14
15-16
17-18
19-20
21-22
23-24
25-26
27-28
29-30
31-32
33-34
35-36
37-38
39-40
41-42
45-46
43-44
DSLC input
Courtesy of A.Perin
![Page 25: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/25.jpg)
The DSLC
25Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34Courtesy of A.Perin
![Page 26: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/26.jpg)
The DSLC – problem
26Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34Courtesy of A.Perin
![Page 27: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/27.jpg)
The DSLC – solution
27Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Compression and fixing of the flexible part of the DSLC link in
order to avoid displacement which is responsible for the heat load
![Page 28: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/28.jpg)
Re-cabling of RQT4.R3 -RQT5.R3
28Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
The commissioning of the two magnets showed the impossibility to keep the nominal current in the circuits due to the increase of T of DC cables and magnets. This effect produces a significant variation of the resistance of the circuits with
the consequence that the PC is not longer able to provide the nominal
current
Engineering Change Order EDMS n.938480
![Page 29: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/29.jpg)
Re-cabling of RQT4.R3 -RQT5.R3
29Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
The solution proposed is to pull additional DC cables from
the PC to the magnets in order to reduce the resistance
of the circuits and limit the DC cables temperature
The present modification is not mandatory for the 5TeV LHC operation
![Page 30: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/30.jpg)
Re-commissioning of RQT4 – RQT5
30Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
Electrical Quality Assurance
to verifies the integrity of the circuits
Polarity Check
to verify the correct DC cabling
24h heat run
to validate the electrical circuits(ventilation and equipments have
been already validated in the previous campaign)
![Page 31: Other systems – what needs to be done? Repair and reinstallation of other systems](https://reader035.fdocuments.us/reader035/viewer/2022062323/568161cf550346895dd1c0df/html5/thumbnails/31.jpg)
Resume
31Chamonix 03/02/09 M.Solfaroli/B.Bellesia - Repair of 34
• GENERAL ACTIVITIES (Katy and Julie will better come back to this on Session 05)
• SECTOR 34• Racks (QPS, VAC, PC, CRYO) re-installation and re-
commissioning• BI commissioning
• BSRT regulation and optic bench change (not mandatory)
• RU.L4 replacement (?)• PC short circuit 24h heat run• DSLC
• Ongoing• RQT4 – RQT5
• Re-cabling - Ongoing• Re-commissioning