Other Meltric Products and Services for the and...Other Meltric Products and Services for the Food &...
Transcript of Other Meltric Products and Services for the and...Other Meltric Products and Services for the Food &...
Other Meltric Products and Services for theFood & Beverage Industries
12
Multipin Plugs and Receptacles DXN Explosion Proof Connectors
Multipin products are commonlyused in power and controlapplications. They are availablewith up to 37 contacts and havea total amp capacity rangingfrom 5 to 100 amps. DS7models facilitate star-deltamotor starting.
DXN’s are rated for Class 2Division 2 environments suchas grain silos. Suitable forloads up to 60 amps, DXN’sprovide a compact, waterproofsolution for hazardous locations.
PN Connectors
PN devices are commonlyused to connect low powerresistive and inductive loadsup to 30 amps. PN’s areexcellent for portable equipmentor for applications that requiredevices with smaller dimensions.
Replacement Parts
Stainless Steel Connectors
The need to replace parts israre. However, should they berequired, parts are readilyavailable and reasonably priced.Purchasing the individual partscosts no more that buying anassembled product.
Same Day Shipping
Due to our outstanding customerservice capabilities and themodular design of our product,95% of incoming orders areshipped within 24 hours. Fora small fee, orders can beshipped the same day.
Five Year Warranty
The electrical contacts on Meltricproducts are warranted for fiveyears from date of shipment.The complete product is warrantedfor one year from the date ofshipment. Contact Meltric fora full warranty statement.
300 series stainless steelconnectors are available forapplications where extremecorrosion and physical abuseare anticipated. Some sizes ofDS, DSN, PN and MultipinSeries products are available.
Presented by Meltric and:
FOODBEV 092210 D
Connecting with
the Food and
Beverage Industries
Featuring Meltric’s
Decontactor TM Series
Switch Rated Plugs,
Receptacles and
Electrical Connectors
4640 Ironwood Drive • Franklin, WI 53132
800.433.7642 • Fax 414.817.6161
www.meltric.com
Decontactors are a combination plug, receptacle and disconnect switch in the same device. Using Meltric Decontactorsto connect motors and other electrical equipment instead of hard-wiring can dramatically reduce equipment change-outrelated downtime. Due to their switch ratings, Decontactors allow users to safely and easily make and break electricalconnections under full load, even in wet, and highly corrosive conditions. This eliminates the need for expensive interlocksand auxiliary disconnect switches. Meltric Decontactors improve safety while saving users both time and money.
Meltric DECONTACTORTM Series Plugs,Receptacles and Electrical Connectors... ...Ideally Suited for the Food & Beverage Industries
2 3
Decontactors are built to withstand the harsh environments often found in the food industry. For example, Meltric’ssilver-nickel contacts, stainless steel components, and chemical resistant housings help withstand corrosion causedby frequent washdowns with caustic cleaners. The butt-style pressure contacts ensure excellent electrical connectionseven in dusty or greasy environments. Other features, such as lockout tagout capability and optional integral pilotcontacts, help make the operation of food and beverage plants safer and more efficient.
Portable pump connection Electrical connections production Crystallizer motor connectionat a beverage plant area - produce processing plant Sugar Cane Growers Cooperative, Florida
Overhead connections along a Connecting portable and stationary Modular conveyorproduction line - dairy industry equipment - meat processing connections - pickle line
Reduce DowntimeDecontactors reduce downtime related to electrical equipment change-outs.When Decontactors are used in lieu of hard-wiring, a mechanic can change outa motor safely and efficiently. A conveyor line or a process pump can be upand running in a matter of minutes instead of a matter of hours. Productionhalts are minimized and rewiring errors are virtually eliminated.
Ensure Safety for Maintenance PersonnelDecontactor safety features include: dead front construction, enclosed arcchambers, silver-nickel butt-style pressure contacts, and short circuit make andwithstand ratings ≥ 65kA. These features ensure safety by preventing access to liveparts, by providing a superior electrical connection that does not deteriorate with wear or oxidation,and by allowing users to safely make & break connections - even during wet or overload conditions.
Provide Watertight, Durable ConnectionsDecontactors provide safe, durable electrical connections - even in washdownenvironments. Rated watertightness up to NEMA 4X is achieved as soon asthe plug mates with the receptacle (DS & DSN models). A Decontactor’scoil spring-loaded silver-nickel contacts offer superior electrical performancethat does not deteriorate with wear or oxidation, unlike competitors’ brasspin & sleeve contacts.
Simplify Code ComplianceDecontactors provide food and beverage factories with a simple and cost-effective .means of achieving code compliance. A Decontactor’s switch rating allows it toperform as the NEC required ‘line of sight’ disconnect - the need and expense of
a separate disconnect switch is eliminated. Decontactors also help facil-ities comply to NFPA 70E or CSA Z462 requirements. A Decontactor’s
dead front construction prevents worker exposure to live parts. As a result,qualified mechanics can change out a motor without needing cumbersome PPE.
Allow Easy Production Line ReconfigurationsDecontactors allow conveyor motors and other electrical equipment to be safely
. connected or disconnected with plug and play simplicity. Reconfigurations.......... of production lines are simplified when Decontactors are used to create a. modular system. Time spent performing electrical work is minimized.
Facilitate Quick Disconnection & ReconnectionDecontactors allow easy disconnection, even by operators with gloves on.
. Simply press the latch to break the load and, if desired, lightly twist the plug
. to remove it. Alternatively, the plug can remain in the receptacle to keep itconveniently out of the way. By contrast, pin and sleeve or twist type connections
. require much greater force to remove the plug and once the plug is removed. it often must be laid down on the floor, creating unnecessary clutter.
Decontactors are a combination plug, receptacle and disconnect switch in the same device. Using Meltric Decontactorsto connect motors and other electrical equipment instead of hard-wiring can dramatically reduce equipment change-outrelated downtime. Due to their switch ratings, Decontactors allow users to safely and easily make and break electricalconnections under full load, even in wet, and highly corrosive conditions. This eliminates the need for expensive interlocksand auxiliary disconnect switches. Meltric Decontactors improve safety while saving users both time and money.
Meltric DECONTACTORTM Series Plugs,Receptacles and Electrical Connectors... ...Ideally Suited for the Food & Beverage Industries
2 3
Decontactors are built to withstand the harsh environments often found in the food industry. For example, Meltric’ssilver-nickel contacts, stainless steel components, and chemical resistant housings help withstand corrosion causedby frequent washdowns with caustic cleaners. The butt-style pressure contacts ensure excellent electrical connectionseven in dusty or greasy environments. Other features, such as lockout tagout capability and optional integral pilotcontacts, help make the operation of food and beverage plants safer and more efficient.
Portable pump connection Electrical connections production Crystallizer motor connectionat a beverage plant area - produce processing plant Sugar Cane Growers Cooperative, Florida
Overhead connections along a Connecting portable and stationary Modular conveyorproduction line - dairy industry equipment - meat processing connections - pickle line
Reduce DowntimeDecontactors reduce downtime related to electrical equipment change-outs.When Decontactors are used in lieu of hard-wiring, a mechanic can change outa motor safely and efficiently. A conveyor line or a process pump can be upand running in a matter of minutes instead of a matter of hours. Productionhalts are minimized and rewiring errors are virtually eliminated.
Ensure Safety for Maintenance PersonnelDecontactor safety features include: dead front construction, enclosed arcchambers, silver-nickel butt-style pressure contacts, and short circuit make andwithstand ratings ≥ 65kA. These features ensure safety by preventing access to liveparts, by providing a superior electrical connection that does not deteriorate with wear or oxidation,and by allowing users to safely make & break connections - even during wet or overload conditions.
Provide Watertight, Durable ConnectionsDecontactors provide safe, durable electrical connections - even in washdownenvironments. Rated watertightness up to NEMA 4X is achieved as soon asthe plug mates with the receptacle (DS & DSN models). A Decontactor’scoil spring-loaded silver-nickel contacts offer superior electrical performancethat does not deteriorate with wear or oxidation, unlike competitors’ brasspin & sleeve contacts.
Simplify Code ComplianceDecontactors provide food and beverage factories with a simple and cost-effective .means of achieving code compliance. A Decontactor’s switch rating allows it toperform as the NEC required ‘line of sight’ disconnect - the need and expense of
a separate disconnect switch is eliminated. Decontactors also help facil-ities comply to NFPA 70E or CSA Z462 requirements. A Decontactor’s
dead front construction prevents worker exposure to live parts. As a result,qualified mechanics can change out a motor without needing cumbersome PPE.
Allow Easy Production Line ReconfigurationsDecontactors allow conveyor motors and other electrical equipment to be safely
. connected or disconnected with plug and play simplicity. Reconfigurations.......... of production lines are simplified when Decontactors are used to create a. modular system. Time spent performing electrical work is minimized.
Facilitate Quick Disconnection & ReconnectionDecontactors allow easy disconnection, even by operators with gloves on.
. Simply press the latch to break the load and, if desired, lightly twist the plug
. to remove it. Alternatively, the plug can remain in the receptacle to keep itconveniently out of the way. By contrast, pin and sleeve or twist type connections
. require much greater force to remove the plug and once the plug is removed. it often must be laid down on the floor, creating unnecessary clutter.
Disconnect may bedifficult to install in“line of sight” fromthe motor
MOTOR CHANGE-OUT PROCESS
1. Electrician opens disconnect switch
2. Suit up with appropriate PPE
3. Remove disconnect cover
4. Voltmeter test to verify deenergization
5. Apply lockout / tagout
6. Disconnect motor from hard-wiring
7. Mechanic removes old/ installs new motor
8. Electrician connects motor to hard-wiring
� Cord connection allowseasy “line of sight”area
� Dead front eliminatesaccess to live parts, sothere is no need forcumbersome PPE
� Ability to safely make& break under loadeliminates the needfor interlocks
� ≥65kA short circuitmake & withstand ratingensures safety duringreenergization
MOTOR CHANGE-OUT PROCESS
1. Mechanic removes plug from receptacle
2. Apply lockout / tagout as required
3. Mechanic removes old/ installs new motor
4. Mechanic inserts plug into receptacle
Meltric Makes it
Safe & Easy
� Expensive mechanicalinterlocks are requiredsince these plugs &receptacles cannotsafely make & breakunder load
� The interlock must bemounted on a fixedsurface-this may make“line of sight” locationmore difficult
MOTOR CHANGE-OUT PROCESS
1. Open interlock switch
2. Suit up with appropriate PPE
3. Remove interlock cover
4. Voltmeter test to verify deenergization
5. Remove plug
6. Apply lockout / tagout as required
7. Remove old/ install new motor
8. Insert plug into receptacle
Meltric DECONTACTORTM Series Plugs & Receptacles... ...Offering Safety and Code Compliance
4 5
Tests passed by Meltric Decontactors and by traditional pin and sleevetype plugs and receptacles (per UL 1682 and CSA 22.2 No. 182.1)
Temperature Rise (not to exceed 30°C over ambient)
50 operations @ 150% device rating and .7 - .8 power factor
Endurance - number of operations @ .75 - .8 power factor
• 20A 5,000 under load 0 off load• 30 to 60A 1,000 under load 1,000 off load• 100 to 200A 250 under load 250 off load
Additional Tests passed exclusively by DecontactorTM Series plugs andreceptacles per UL Subject 2682.
50 operations @ 6x motor FLA .4 - .5 power factor
6,000 operations @ FLA .75 - .8 power factor
Short circuit make and withstand @ ≥65kA, 600V and < .15 PF
Additional Listings include: IEC/EN 60309-1, 60947-3, AS 3123
Spring loading ensures optimal contact forceover thousands of operations. Plus, the per-formance of silver-nickel is not affected byoxidation. By contrast, the contact force ofcompetitive pin & sleeve devices decreaseswith use and the conductivity of their brasscontacts degrades significantly due to oxidation.
Rated watertightness, up to NEMA 4X, isachieved as soon as the plug mates with thereceptacle (DS & DSN). Competitive productsrequire the user to remember to carefullytighten an additional plastic ring.
The dead front design eliminates access tolive parts. They can only be accessed by thecorrect mating plug after insertion into thereceptacles. Meltric’s dead front design alsohelps avoid the need for cumbersomePersonal Protective Equipment and thusallows faster and safer motor change-outs.
Dead Front
Assures safety by preventinguser access to live parts.
Contact Tips
Silver-nickel material offersexceptional resistance tocorrosion.
Casing
Offers great resistance to impactand harsh environmental conditions.
Pushbutton Pawl
Provides quick, safe andeasy load break.
Spring-Assisted Screw Terminals
Patented design assures “Tightenand Forget” confidence.
Spring-Loaded Contacts
Ensures consistent contact forceover thousands of operations.
Lid
Provides additional protectionfrom harsh environments.
Meltric Decontactors are the world’s only UL and CSA switch rated plugs and receptacles. Not only do they meet performance test requirementsfor UL 1682/CSA C22.2 No. 182.1 (to which competitive pin and sleeve devices are listed), but Decontactors also meet the performance testrequirements in UL Subject 2682 “Switch-Rated Plugs and Receptacles.” Based on their evaluation against this standard, Decontactors are ULand CSA listed for use in motor circuit disconnect /switching applications and in branch circuit disconnect /switching applications.
Coil SpringSilver-nickelcontacts
• Allows easy NFPA 70E/CSA Z462code compliance
• Functions as a ‘line of sight’disconnect switch
• Safely makes and breaksresistive or inductive loads
�
�
�
Tested to a Higher Standard
Butt-Style Pressure Contacts Watertight Dead Front Design
DSN pictured
18”
OR
OR
MOTOR HARD-WIRED TO ABLADED DISCONNECT SWITCH
MOTOR CONNECTED WITH AMELTRIC MOTOR PLUG
MOTOR CONNECTED WITH ACOMPETITIVE PLUG & RECEPTACLE
Articles 430.101 through 430.113 regulate motor disconnection means.They require motors to have readily accessible, Line of Sight disconnectsthat are either an approved switch or a properly rated plug and receptacle.
� 430.102 A disconnecting means must be located in sight from themotor and driven equipment.
� 430.107 The disconnecting means must be readily accessible.
� 430.109 The disconnecting means must be an approved switch ora horsepower rated plug & receptacle with ratings at leastequivalent to the motor ratings.
� 430.110 The disconnecting means must have an amp rating atleast 115% of the full-load current rating of the motor.The horsepower rating of the disconnecting means mustbe determined based on the sum of all resistive currentsand the locked rotor current of the motor.
This OSHA consensus standard covers electrical safety related workpractices and procedures for employees who work on or near exposedenergized electrical conductors or circuit parts. Relevant requirements include:
Power must be proven to be off before performing work. This includes:
� The safe interruption of the load & opening of the disconnect
� Visual verification/voltage testing to ensure deenergization
The potential electrical hazard must be identified and documented.
� Flash hazard analysis must be performed
� Flash protection boundaries must be determined
Appropriate steps must be taken to protect persons working near liveparts or within the flash protection boundary.
� Personal Protective Equipment must be provided based on therelevant incident energy exposure levels (cal /cm2)
� Only properly qualified persons shall be allowed to perform work
SAFETY & CODE COMPLIANCE: Meltric vs Competition
National Electric Code NFPA 70E/CSA Z462
CODE COMPLIANCE: What the Codes Require
QualifiedWorkerw/PPE
Meltric’s DECONTACTORTM Series Plugs & Receptacles pass testing atthe 6xFLA current level required relative to locked rotor conditions.
By using Meltric’s DECONTACTORTMSeries Plugs&Receptacles to connectequipment, users can avoid ALL these requirements and procedures.
See published NFPA 70E/CSA Z462 standard for complete safety requirements.
��
�
Disconnect may bedifficult to install in“line of sight” fromthe motor
MOTOR CHANGE-OUT PROCESS
1. Electrician opens disconnect switch
2. Suit up with appropriate PPE
3. Remove disconnect cover
4. Voltmeter test to verify deenergization
5. Apply lockout / tagout
6. Disconnect motor from hard-wiring
7. Mechanic removes old/ installs new motor
8. Electrician connects motor to hard-wiring
� Cord connection allowseasy “line of sight”area
� Dead front eliminatesaccess to live parts, sothere is no need forcumbersome PPE
� Ability to safely make& break under loadeliminates the needfor interlocks
� ≥65kA short circuitmake & withstand ratingensures safety duringreenergization
MOTOR CHANGE-OUT PROCESS
1. Mechanic removes plug from receptacle
2. Apply lockout / tagout as required
3. Mechanic removes old/ installs new motor
4. Mechanic inserts plug into receptacle
Meltric Makes it
Safe & Easy
� Expensive mechanicalinterlocks are requiredsince these plugs &receptacles cannotsafely make & breakunder load
� The interlock must bemounted on a fixedsurface-this may make“line of sight” locationmore difficult
MOTOR CHANGE-OUT PROCESS
1. Open interlock switch
2. Suit up with appropriate PPE
3. Remove interlock cover
4. Voltmeter test to verify deenergization
5. Remove plug
6. Apply lockout / tagout as required
7. Remove old/ install new motor
8. Insert plug into receptacle
Meltric DECONTACTORTM Series Plugs & Receptacles... ...Offering Safety and Code Compliance
4 5
Tests passed by Meltric Decontactors and by traditional pin and sleevetype plugs and receptacles (per UL 1682 and CSA 22.2 No. 182.1)
Temperature Rise (not to exceed 30°C over ambient)
50 operations @ 150% device rating and .7 - .8 power factor
Endurance - number of operations @ .75 - .8 power factor
• 20A 5,000 under load 0 off load• 30 to 60A 1,000 under load 1,000 off load• 100 to 200A 250 under load 250 off load
Additional Tests passed exclusively by DecontactorTM Series plugs andreceptacles per UL Subject 2682.
50 operations @ 6x motor FLA .4 - .5 power factor
6,000 operations @ FLA .75 - .8 power factor
Short circuit make and withstand @ ≥65kA, 600V and < .15 PF
Additional Listings include: IEC/EN 60309-1, 60947-3, AS 3123
Spring loading ensures optimal contact forceover thousands of operations. Plus, the per-formance of silver-nickel is not affected byoxidation. By contrast, the contact force ofcompetitive pin & sleeve devices decreaseswith use and the conductivity of their brasscontacts degrades significantly due to oxidation.
Rated watertightness, up to NEMA 4X, isachieved as soon as the plug mates with thereceptacle (DS & DSN). Competitive productsrequire the user to remember to carefullytighten an additional plastic ring.
The dead front design eliminates access tolive parts. They can only be accessed by thecorrect mating plug after insertion into thereceptacles. Meltric’s dead front design alsohelps avoid the need for cumbersomePersonal Protective Equipment and thusallows faster and safer motor change-outs.
Dead Front
Assures safety by preventinguser access to live parts.
Contact Tips
Silver-nickel material offersexceptional resistance tocorrosion.
Casing
Offers great resistance to impactand harsh environmental conditions.
Pushbutton Pawl
Provides quick, safe andeasy load break.
Spring-Assisted Screw Terminals
Patented design assures “Tightenand Forget” confidence.
Spring-Loaded Contacts
Ensures consistent contact forceover thousands of operations.
Lid
Provides additional protectionfrom harsh environments.
Meltric Decontactors are the world’s only UL and CSA switch rated plugs and receptacles. Not only do they meet performance test requirementsfor UL 1682/CSA C22.2 No. 182.1 (to which competitive pin and sleeve devices are listed), but Decontactors also meet the performance testrequirements in UL Subject 2682 “Switch-Rated Plugs and Receptacles.” Based on their evaluation against this standard, Decontactors are ULand CSA listed for use in motor circuit disconnect /switching applications and in branch circuit disconnect /switching applications.
Coil SpringSilver-nickelcontacts
• Allows easy NFPA 70E/CSA Z462code compliance
• Functions as a ‘line of sight’disconnect switch
• Safely makes and breaksresistive or inductive loads
�
�
�
Tested to a Higher Standard
Butt-Style Pressure Contacts Watertight Dead Front Design
DSN pictured
18”
OR
OR
MOTOR HARD-WIRED TO ABLADED DISCONNECT SWITCH
MOTOR CONNECTED WITH AMELTRIC MOTOR PLUG
MOTOR CONNECTED WITH ACOMPETITIVE PLUG & RECEPTACLE
Articles 430.101 through 430.113 regulate motor disconnection means.They require motors to have readily accessible, Line of Sight disconnectsthat are either an approved switch or a properly rated plug and receptacle.
� 430.102 A disconnecting means must be located in sight from themotor and driven equipment.
� 430.107 The disconnecting means must be readily accessible.
� 430.109 The disconnecting means must be an approved switch ora horsepower rated plug & receptacle with ratings at leastequivalent to the motor ratings.
� 430.110 The disconnecting means must have an amp rating atleast 115% of the full-load current rating of the motor.The horsepower rating of the disconnecting means mustbe determined based on the sum of all resistive currentsand the locked rotor current of the motor.
This OSHA consensus standard covers electrical safety related workpractices and procedures for employees who work on or near exposedenergized electrical conductors or circuit parts. Relevant requirements include:
Power must be proven to be off before performing work. This includes:
� The safe interruption of the load & opening of the disconnect
� Visual verification/voltage testing to ensure deenergization
The potential electrical hazard must be identified and documented.
� Flash hazard analysis must be performed
� Flash protection boundaries must be determined
Appropriate steps must be taken to protect persons working near liveparts or within the flash protection boundary.
� Personal Protective Equipment must be provided based on therelevant incident energy exposure levels (cal /cm2)
� Only properly qualified persons shall be allowed to perform work
SAFETY & CODE COMPLIANCE: Meltric vs Competition
National Electric Code NFPA 70E/CSA Z462
CODE COMPLIANCE: What the Codes Require
QualifiedWorkerw/PPE
Meltric’s DECONTACTORTM Series Plugs & Receptacles pass testing atthe 6xFLA current level required relative to locked rotor conditions.
By using Meltric’s DECONTACTORTMSeries Plugs&Receptacles to connectequipment, users can avoid ALL these requirements and procedures.
See published NFPA 70E/CSA Z462 standard for complete safety requirements.
��
�
Conveyor Systems
Decontactors enable conveyor systems to be quickly reconfigured and also allow motors to be easily replaced.
� Enable ModularityA mechanic can safely and easily make or break live electricalconnections on conveyors. The conveyors can then be quicklyreconfigured to meet flexible production needs.
� Allow Advanced ControlAuxiliary/pilot contacts can operate secondary control circuits tosend alarm signals or turn other equipment on or off dependingon system requirements.
Pumps and Mixers
Decontactors provide safe and quick motor connections - even in wet environments.
� Ensure SafetyWorkers can safely make and break electrical connections onmotors up to 60 hp. Butt-style contact technology, enclosed arcchambers, dead front construction, and short circuit make &withstand capabilities ensure user safety.
� Maximize DurabilityDecontactors are built to withstand harsh and wet environments.The casings are shock resistant, the silver-nickel contacts are corrosionresistant, and the complete unit is watertight up to NEMA 4X (DSN).
Portable and Handheld Equipment
Decontactors allow safe and easy equipment disconnection, even by users with gloves on.
� Inhibit CorrosionSilver-nickel contact materials and stainless steel metal parts provideexceptional resistance to corrosion in caustic washdown environments.
� Simplify OperationDecontactors are safely and easily disconnected - even with gloves on.Simply press the release button (pawl) and then lightly rotate the plugfor removal.
Production Line Equipment
Decontactors facilitate the reconfiguration of production line equipment.
� Minimize Design Hassles and Installation CostsDecontactors eliminate the need for mechanical interlocks and auxiliarydisconnects, saving design and installation time.
� Reduce DowntimeA mechanic can break the power, relocate or service equipmentand reconnect power in minutes. There is no hand-wiring required,even for equipment with controls.
Equipment Control Wire Connections
Meltric Decontactors and Meltric Multipin connectors allow quick, error-free control wire connections.
� Simplify Control Wiring and MaintenanceDecontactors with optional pilot contacts are ideal for controlling auxiliaryequipment or monitoring key operational procedures. For more complexcontrol schemes, Meltric Multipin connectors are available with up to 37contacts. Both products enable quick reconfigurations of processingequipment without the need for hard-wiring or multiple plug connections.
� Promote Error-Free ConnectionsAvoid rewiring errors during equipment change-outs. Meltric connectorsprovide ‘plug and play’ simplicity, even in washdown environments.
Electrical Connections for Vehicles
Decontactors provide a convenient, durable means of connecting power to stationary vehicles.
� Withstand Rough HandlingDecontactor casings offer great resistance to impact and harshenvironments. The silver-nickel, butt-style contact configurationallows users to routinely make and break the electrical connections.
� Prevent DamagePotential for “drive away” damage to the electrical connectionis virtually eliminated with Meltric’s optional self ejecting feature.
Application Spotlights Application Spotlights
6 7
1 2 3
Decontactors with optional auxiliary/pilotcontacts can convey alarms or control auxiliary
equipment along a conveyor line.
Decontactors withstand washdown environments,providing safe, durable connections for pumps and mixers.
A Decontactors enclosed arc chambers anddead front construction ensure user safety.
Decontactors allow users to safely and routinely makeor break equipment connection - even under full load.
Meltric Stainless Steel Multipin connectorsprovide maximum durability and corrosion resistance
in critical control applications.
Decontactors with optional self-ejectingsystem prevents damage in drive away situations.
Conveyor Systems
Decontactors enable conveyor systems to be quickly reconfigured and also allow motors to be easily replaced.
� Enable ModularityA mechanic can safely and easily make or break live electricalconnections on conveyors. The conveyors can then be quicklyreconfigured to meet flexible production needs.
� Allow Advanced ControlAuxiliary/pilot contacts can operate secondary control circuits tosend alarm signals or turn other equipment on or off dependingon system requirements.
Pumps and Mixers
Decontactors provide safe and quick motor connections - even in wet environments.
� Ensure SafetyWorkers can safely make and break electrical connections onmotors up to 60 hp. Butt-style contact technology, enclosed arcchambers, dead front construction, and short circuit make &withstand capabilities ensure user safety.
� Maximize DurabilityDecontactors are built to withstand harsh and wet environments.The casings are shock resistant, the silver-nickel contacts are corrosionresistant, and the complete unit is watertight up to NEMA 4X (DSN).
Portable and Handheld Equipment
Decontactors allow safe and easy equipment disconnection, even by users with gloves on.
� Inhibit CorrosionSilver-nickel contact materials and stainless steel metal parts provideexceptional resistance to corrosion in caustic washdown environments.
� Simplify OperationDecontactors are safely and easily disconnected - even with gloves on.Simply press the release button (pawl) and then lightly rotate the plugfor removal.
Production Line Equipment
Decontactors facilitate the reconfiguration of production line equipment.
� Minimize Design Hassles and Installation CostsDecontactors eliminate the need for mechanical interlocks and auxiliarydisconnects, saving design and installation time.
� Reduce DowntimeA mechanic can break the power, relocate or service equipmentand reconnect power in minutes. There is no hand-wiring required,even for equipment with controls.
Equipment Control Wire Connections
Meltric Decontactors and Meltric Multipin connectors allow quick, error-free control wire connections.
� Simplify Control Wiring and MaintenanceDecontactors with optional pilot contacts are ideal for controlling auxiliaryequipment or monitoring key operational procedures. For more complexcontrol schemes, Meltric Multipin connectors are available with up to 37contacts. Both products enable quick reconfigurations of processingequipment without the need for hard-wiring or multiple plug connections.
� Promote Error-Free ConnectionsAvoid rewiring errors during equipment change-outs. Meltric connectorsprovide ‘plug and play’ simplicity, even in washdown environments.
Electrical Connections for Vehicles
Decontactors provide a convenient, durable means of connecting power to stationary vehicles.
� Withstand Rough HandlingDecontactor casings offer great resistance to impact and harshenvironments. The silver-nickel, butt-style contact configurationallows users to routinely make and break the electrical connections.
� Prevent DamagePotential for “drive away” damage to the electrical connectionis virtually eliminated with Meltric’s optional self ejecting feature.
Application Spotlights Application Spotlights
6 7
1 2 3
Decontactors with optional auxiliary/pilotcontacts can convey alarms or control auxiliary
equipment along a conveyor line.
Decontactors withstand washdown environments,providing safe, durable connections for pumps and mixers.
A Decontactors enclosed arc chambers anddead front construction ensure user safety.
Decontactors allow users to safely and routinely makeor break equipment connection - even under full load.
Meltric Stainless Steel Multipin connectorsprovide maximum durability and corrosion resistance
in critical control applications.
Decontactors with optional self-ejectingsystem prevents damage in drive away situations.
PROCESSING – BEVERAGE
SHIPPING/RECEIVING
Connect trucks, conveyors, refrigerated vehicles
Meltric Decontactor withoptional self-ejecting system
PROCESSING – BAKERY
STORAGE
Connect mixers, pumps, grinders, aerators, fans
Meltric Decontactors withstandard dead front construction
exempt users from NFPA 70E/CSA Z462requirements for cumbersome PPE
Meltric Decontactor - meetscode requirements for ‘lineof sight’ disconnect
Connect tumblers, pumps, pasteurizers, freezers, chillers
Meltric Decontactors functionas an “in-line” switch
STOP
STOP
GROWING PROCESSING – MEAT
CONVEYING PACKAGING MAINTENANCE PLANT WASTEWATER
Benefit from Meltric Connectors... ...Throughout Your Plant
8 9
Connect submersible mixers, pumps, aeratorsConnect hvac equipment, welders, and portable wash tanksConnect cartoners, wrappers, baggers, sealers, fillersConnect portable or stationary motor driven conveyors
Meltric Decontactorsenable easy equipment
change-outs
SubmersibleMixer
Meltric Decontactors withoptional pilot contacts forsecondary control circuits
Connection forfan motor
Decontactor inletscan be mounted
directly on portableequipment
Depositor
Conveyor
DSN SeriesDecontactor
with NEMA 4Xrating
Nylon conduit entrybox for washdown
environment
Bandsaw
Portable Power Distributionwith Decontactors
Cordsets builtto customers
specifications withDecontactors
Connect separators, saws, slicers, grinders, formers, choppersConnect ovens, mixers, pumps, extruders, depositorsConnect stackers, slingers, pumps, fans, hvac equipment
Replacementmotor prewiredat motor service
center
Non-electrical personnelcan replace motors that
are connected viaDecontactors
Motor-driving criticalprocess equipment
Portable Fanor Pump
Submersiblemixer connection
PROCESSING – DAIRY
Meltric Decontactors usesilver-nickel contacts and stainless
steel hardware for maximumcorrosion resistance
Wash tank
Connect pasteurizers, homogenizers, mixers, blenders
PROCESSING – PRODUCE
Modularpackagingequipment
Connect washers, conveyors, pumps. hvac equipment
Decontactors allowportable heating, ventilating, orair conditioning equipment tobe safely and easily connected
Portable AC unit
Minimize tangledand damaged cordsby connecting toportable equipmentwith cord mountedDecontactor receptacles
Decontactors allowworkers to safely
connect or disconnectelectrical equipment -even under overload
conditions in wetenvironments
Connection formachine power and
control wires
PROCESSING – BEVERAGE
SHIPPING/RECEIVING
Connect trucks, conveyors, refrigerated vehicles
Meltric Decontactor withoptional self-ejecting system
PROCESSING – BAKERY
STORAGE
Connect mixers, pumps, grinders, aerators, fans
Meltric Decontactors withstandard dead front construction
exempt users from NFPA 70E/CSA Z462requirements for cumbersome PPE
Meltric Decontactor - meetscode requirements for ‘lineof sight’ disconnect
Connect tumblers, pumps, pasteurizers, freezers, chillers
Meltric Decontactors functionas an “in-line” switch
STOP
STOP
GROWING PROCESSING – MEAT
CONVEYING PACKAGING MAINTENANCE PLANT WASTEWATER
Benefit from Meltric Connectors... ...Throughout Your Plant
8 9
Connect submersible mixers, pumps, aeratorsConnect hvac equipment, welders, and portable wash tanksConnect cartoners, wrappers, baggers, sealers, fillersConnect portable or stationary motor driven conveyors
Meltric Decontactorsenable easy equipment
change-outs
SubmersibleMixer
Meltric Decontactors withoptional pilot contacts forsecondary control circuits
Connection forfan motor
Decontactor inletscan be mounted
directly on portableequipment
Depositor
Conveyor
DSN SeriesDecontactor
with NEMA 4Xrating
Nylon conduit entrybox for washdown
environment
Bandsaw
Portable Power Distributionwith Decontactors
Cordsets builtto customers
specifications withDecontactors
Connect separators, saws, slicers, grinders, formers, choppersConnect ovens, mixers, pumps, extruders, depositorsConnect stackers, slingers, pumps, fans, hvac equipment
Replacementmotor prewiredat motor service
center
Non-electrical personnelcan replace motors that
are connected viaDecontactors
Motor-driving criticalprocess equipment
Portable Fanor Pump
Submersiblemixer connection
PROCESSING – DAIRY
Meltric Decontactors usesilver-nickel contacts and stainless
steel hardware for maximumcorrosion resistance
Wash tank
Connect pasteurizers, homogenizers, mixers, blenders
PROCESSING – PRODUCE
Modularpackagingequipment
Connect washers, conveyors, pumps. hvac equipment
Decontactors allowportable heating, ventilating, orair conditioning equipment tobe safely and easily connected
Portable AC unit
Minimize tangledand damaged cordsby connecting toportable equipmentwith cord mountedDecontactor receptacles
Decontactors allowworkers to safely
connect or disconnectelectrical equipment -even under overload
conditions in wetenvironments
Connection formachine power and
control wires
Use auxiliary/pilot contacts for oper-ating secondary control circuits or forelectrical interlocking with the motorstarter. These contacts make last andbreak first when the plug is engagedor disengaged. Two to six auxiliarycontacts are available on a Decontactor.
An emergency stop pawl is availableas an alternative to the standard pawl.It provides a larger button that iseasier to actuate, making it ideal inareas where quick disconnects maybe required.
Use padlock pawls or padlock plug capsfor preventing unwanted connection ordisconnection of plugs. Padlock pawlsalso allow the lid to be locked closed.Padlockable plug caps provide NEMA4X watertightness (DSN only).
Normally closed lids for femaledevices are available for applicationswhere the receptacle will be exposedto excessive moisture or debris.The lid will automatically close toa pre-latch position.
Use PH or PM handles for connectingto flexible conduit, for strain relief onsuspended connections, and forenhanced watertightness. Finger drawplates should also be considered foreasier connector closure.
Nylon conduit entry boxes are availablefor washdown applications where ametallic box is not desirable. Applicationsutilizing large wire sizes should bechecked for ‘fit’ before ordering.
PilotContacts
MushroomPawl
Horsepower Ratings
Product Technology & Specifications Common Food & Beverage Industry Options
10 11
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 30
DSN 60
1/2 hp
1 hp
2 hp
1 hp
3 hp
3 hp
2 hp
5 hp
7 1/2 hp
2 hp
5 hp
7 1/2 hp
5 hp
10 hp
20 hp
15 hp
20 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DSN DBDS
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS60 or DS100C
1/2 hp
3/4 hp
2 hp
1 1/2 hp
2 hp
3 hp
3 hp
7 1/2 hp
1 1/2 hp
3 hp
7 1/2 hp
5 hp
10 hp
20 hp
7 1/2 hp
25 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
1 1/2 hp
3 hp
7 1/2 hp
3 hp
7 1/2 hp
10 hp
7 1/2 hp
15 hp
30 hp
7 1/2 hp
15 hp
30 hp
10 hp
30 hp
60 hp
10 hp
30 hp
60 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DSN’s are the most compact and lightweightof the Decontactor Series products. Thefiberglass reinforced thermoplastic polyestercasing provides excellent resistance toshock, chemicals and UV rays.
• UL & CSA Switch Rated
• NEMA 4X, IP66+67
• Up to 4 auxiliary contacts
DS’s provide an excellent combination ofcapacity and ruggedness. DS casings aremade of fiberglass reinforced thermoplasticpolyester or zinc alloy, depending onthe model.
• UL & CSA Switch Rated
• NEMA 3R, IP54/55
• Up to 6 auxiliary contacts
DB’s are designed to handle high horsepowerinductive loads (up to 60 hp). The DB’s arcsplitting/blowing system and internal springloaded switch operator provide advancedlevels of performance and safety. Zinc alloycasings stand up to rugged handling.
• UL & CSA Switch Rated
• IP67
• Up to 4 auxiliary contacts
DSN 20-60A DS 20-200A DB 30-100A
Closed Lid Configuration
Self-Ejecting Devices
Meltric’s self-ejecting system employs a “fin” type pawl, which is activated by a tension cord attached between the pawland the power cable. Tension on the cable pulls the cord, releasing the pawl and uncoupling the device. Self-ejectingmodels connect with straight insertion to permit automatic ejection. This option is ideal for truck hook-ups, fork lifts,and refrigerated or heated food carts.
A tension cord is
attached to the
power cable and the
fin pawl of the plug.
Tension on the power
cable automatically
lifts the fin pawl via
the tension cord.
Once the pawl
is lifted, the plug
pulls away from
the receptacle.
Auxiliary/PilotContacts
Mushroom Pawl Lockable Plugs orReceptacles
Nylon Conduit EntryHandle Options
Pre-latchPosition
ConduitEntry
PH Handle OptionalCord Grip with
Wire Mesh
PM Handle
Clamp andBushing
PadlockablePawl Padlockable
Plug Cap
DSN PlugLocking devicenot included
Use auxiliary/pilot contacts for oper-ating secondary control circuits or forelectrical interlocking with the motorstarter. These contacts make last andbreak first when the plug is engagedor disengaged. Two to six auxiliarycontacts are available on a Decontactor.
An emergency stop pawl is availableas an alternative to the standard pawl.It provides a larger button that iseasier to actuate, making it ideal inareas where quick disconnects maybe required.
Use padlock pawls or padlock plug capsfor preventing unwanted connection ordisconnection of plugs. Padlock pawlsalso allow the lid to be locked closed.Padlockable plug caps provide NEMA4X watertightness (DSN only).
Normally closed lids for femaledevices are available for applicationswhere the receptacle will be exposedto excessive moisture or debris.The lid will automatically close toa pre-latch position.
Use PH or PM handles for connectingto flexible conduit, for strain relief onsuspended connections, and forenhanced watertightness. Finger drawplates should also be considered foreasier connector closure.
Nylon conduit entry boxes are availablefor washdown applications where ametallic box is not desirable. Applicationsutilizing large wire sizes should bechecked for ‘fit’ before ordering.
PilotContacts
MushroomPawl
Horsepower Ratings
Product Technology & Specifications Common Food & Beverage Industry Options
10 11
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 20
DSN 30
DSN 60
DSN 30
DSN 60
1/2 hp
1 hp
2 hp
1 hp
3 hp
3 hp
2 hp
5 hp
7 1/2 hp
2 hp
5 hp
7 1/2 hp
5 hp
10 hp
20 hp
15 hp
20 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DSN DBDS
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS 30
DS60 or DS100C
DS 20
DS60 or DS100C
1/2 hp
3/4 hp
2 hp
1 1/2 hp
2 hp
3 hp
3 hp
7 1/2 hp
1 1/2 hp
3 hp
7 1/2 hp
5 hp
10 hp
20 hp
7 1/2 hp
25 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
DB 30
DB 60
DB 100
1 1/2 hp
3 hp
7 1/2 hp
3 hp
7 1/2 hp
10 hp
7 1/2 hp
15 hp
30 hp
7 1/2 hp
15 hp
30 hp
10 hp
30 hp
60 hp
10 hp
30 hp
60 hp
120VSingle Ø
240VSingle Ø
208V3Ø
240V3Ø
480V3Ø
600V3Ø
VOLTAGE hp RATING DEVICE
DSN’s are the most compact and lightweightof the Decontactor Series products. Thefiberglass reinforced thermoplastic polyestercasing provides excellent resistance toshock, chemicals and UV rays.
• UL & CSA Switch Rated
• NEMA 4X, IP66+67
• Up to 4 auxiliary contacts
DS’s provide an excellent combination ofcapacity and ruggedness. DS casings aremade of fiberglass reinforced thermoplasticpolyester or zinc alloy, depending onthe model.
• UL & CSA Switch Rated
• NEMA 3R, IP54/55
• Up to 6 auxiliary contacts
DB’s are designed to handle high horsepowerinductive loads (up to 60 hp). The DB’s arcsplitting/blowing system and internal springloaded switch operator provide advancedlevels of performance and safety. Zinc alloycasings stand up to rugged handling.
• UL & CSA Switch Rated
• IP67
• Up to 4 auxiliary contacts
DSN 20-60A DS 20-200A DB 30-100A
Closed Lid Configuration
Self-Ejecting Devices
Meltric’s self-ejecting system employs a “fin” type pawl, which is activated by a tension cord attached between the pawland the power cable. Tension on the cable pulls the cord, releasing the pawl and uncoupling the device. Self-ejectingmodels connect with straight insertion to permit automatic ejection. This option is ideal for truck hook-ups, fork lifts,and refrigerated or heated food carts.
A tension cord is
attached to the
power cable and the
fin pawl of the plug.
Tension on the power
cable automatically
lifts the fin pawl via
the tension cord.
Once the pawl
is lifted, the plug
pulls away from
the receptacle.
Auxiliary/PilotContacts
Mushroom Pawl Lockable Plugs orReceptacles
Nylon Conduit EntryHandle Options
Pre-latchPosition
ConduitEntry
PH Handle OptionalCord Grip with
Wire Mesh
PM Handle
Clamp andBushing
PadlockablePawl Padlockable
Plug Cap
DSN PlugLocking devicenot included
Other Meltric Products and Services for theFood & Beverage Industries
12
Multipin Plugs and Receptacles DXN Hazardous Duty Connectors
Multipin products are commonlyused in power and controlapplications. They are availablewith up to 37 contacts and havea total amp capacity rangingfrom 5 to 100 amps. DS7models facilitate star-deltamotor starting.
DXN’s are rated for Class 2Division 2 environments suchas grain silos. Suitable forloads up to 60 amps, DXN’sprovide a compact, waterproofsolution for hazardous locations.
PN Connectors
PN devices are commonlyused to connect low powerresistive and inductive loadsup to 30 amps. PN’s areexcellent for portable equipmentor for applications that requiredevices with smaller dimensions.
Replacement Parts
Stainless Steel Connectors
The need to replace parts israre. However, should they berequired, parts are readilyavailable and reasonably priced.Purchasing the individual partscosts no more that buying anassembled product.
Same Day Shipping
Due to our outstanding customerservice capabilities and themodular design of our product,90% of incoming orders areshipped within 24 hours. Fora small fee, orders can beshipped the same day.
Five Year Warranty
The electrical contacts on Meltricproducts are warranted for fiveyears from date of shipment.The complete product is warrantedfor one year from the date ofshipment. Contact Meltric fora full warranty statement.
300 series stainless steelconnectors are available forapplications where extremecorrosion and physical abuseare anticipated. Some sizes ofDS, DSN, PN and MultipinSeries products are available.
Presented by Meltric and:
FOODBEV 120310 E
Connecting with
the Food and
Beverage Industries
Featuring Meltric’s
Decontactor TM Series
Switch Rated Plugs,
Receptacles and
Electrical Connectors
4640 Ironwood Drive • Franklin, WI 53132
800.433.7642 • Fax 414.817.6161
www.meltric.com