OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
Transcript of OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
1/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
www.huawei.com
Internal
OptiX Metro 200 Hardware
Description
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
2/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 1
References
OptiX Metro 200 User Manual
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
3/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2
Upon completion this course, you will be able to:
Know the network application of OptiX Metro 200.
Understand the hardware structure and features
of OptiX Metro 200.
Understand the functions of normally used units.
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
4/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3
Chapter 1 Network Application
Chapter 2 Hardware Structure
Chapter 3 Units Introduction
Chapter 4 Main Features of OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
5/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4
Network Application
Network Application
STM-1 Ring
STM-4 Ring
STM-1 Ring
BSC BSC
BSC
MSC
E1
E1
E1
E1
E1
E1
BTS
BTS BTS BTSBTS
BTS BTS
BTS
E1
E1 E1
E1
OptiX T2000
Metro200
Metro200
155622H(Metro1000)EccEcc
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
6/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5
Network Application
The following network topologies are supported by Metro 200
Networking
Link Topology
Ring Topology
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
7/24HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6
Chapter 1 Network Application
Chapter 2 Hardware Structure
Chapter 3 Unit Introduction
Chapter 4 Main Feature of OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
8/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7
Hardware Structure
System Structure
Line
unit
Order
wire
unit
Timing
unit
Main
contr
ol unit
Tributary
unit
VC-4 VC-4
VC-4 VC-4
155Mbit/s 2.048Mbit/s
NMsystem
Asynchronous
transparentdata
2.048Mbit/s155Mbit/s
VC-4 cross-
connect matrix
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
9/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8
Hardware Structure
1. Grounding
Terminal
2. Indicators 3. Optical Interface 4. Reset Switch 5. Clock Input/Output
Interface
6. Boolean Value
Interface
7. ESD Wrist Strap
Jack
8. -48V Power Unit 9. Power Switch 10. Indicators for the
Optical Interfaces
11. NM Interface 12. Transparent Data
Interface (F2)
13. E1 Electrical
Interface
Interfaces
OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
10/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9
Chapter 1 Network Application
Chapter 2 Hardware Structure
Chapter 3 Units Introduction
Chapter 4 Main Features of OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
11/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10
Units Introduction
Receive and transmit 8E1(75/120) signals.
Provide automatic protection switching.
Provide inloop and outloop.
Process the VC-12 path overhead (POH) and monitor the path
of each service.
Tributary unit
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
12/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11
Units Introduction
Provide one or two S-1.1 STM-1 optical interfaces.
Detect and report various alarm signals and
performance events on the line. Process high order overhead
Form networks such as chain and ring when working
with cross-connect unit.
Provide inloop and outloop for prompt fault location..
Provide Automatic Laser Shutdown (ALS) function.
Line unit
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
13/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12
Units Introduction
Perform cross connection to the line and line signals, line
and tributary signals, and tributary and tributary signals.
Add/drop the tributary E1 signal and groom VC-4 signalsfreely.
Support network topologies such as point-to-point, chain and
ring.
Support configuring Network Element (NE) into Terminal
Multiplexer (TM) or Add/Drop Multiplexer (ADM).
Cross-connect unit
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
14/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13
Units Introduction
Extract/insert, switch and broadcast the overhead bytes, support
point-to-point, point-to-multipoint equipment interconnection.
Transform, process and save the performance data and hardware
alarm events received by the line unit, tributary unit, timing unit,orderwire unit, etc..
Facilitate the SDH NM system in managing NE boards.
Pass the control and management information to upstream or
downstream NEs.
Provide DCC for communication with remote NEs.
Monitor, maintain and manage the equipment in real time.
Access asynchronous serial data.
Main control & Orderwire unit
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
15/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14
Units Introduction
Provide synchronization clock for the system line unit and
tributary unit.
Lock the line and tributary timing source for system
synchronization.
Provide the system with five timing sources.
In maser/slave synchronization mode, the clock of NE node
generally has the following three working modes:
Locked mode
Holdover mode
Free-run mode
Timing unit
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
16/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15
Chapter 1 Network Application
Chapter 2 Hardware Structure
Chapter 3 Units Introduction
Chapter 4 Main Features of OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
17/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16
Main Features of OptiX Metro 200
OptiX Metro 200 provides service access capabilities listed as
follow:
Access Capability
Service Type Maximum Access Capability
STM-1 2
E1 service 8
64kbit/s service 1
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
18/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Main Features of OptiX Metro 200
OptiX Metro 200 support two different management mode:
OptiX iManager T2000
OptiX iManager T2000 performs operation, administration andmaintenance (OAM) over the OptiX Metro 200, realizing service
configuration and allocation, and ensuring reliable running of the
network.
Web-LCT
In the terminal computer with an Explorer of Release 5.0 or above,
input the IP address, you can configure services or query alarms of
the OptiX Metro 200, as well as other NMS operations.
Management Mode
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
19/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18
Main Features of OptiX Metro 200
Network Protection
Path Protection
Two-fiber unidirectional path protection ring
Two-fiber bidirectional path protection ring
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
20/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19
Main Features of OptiX Metro 200
-48V DC:
It provides two DC power supply ports, backing up each other.
Monitor the input voltage and generate alarms for over-voltage or
under-voltage.
220V AC:
Two internal power modules back up each other.
Provide alarms upon power module failure.
Power Supply Protection
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
21/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
Main Features of OptiX Metro 200
Services will be automatically configured once the NE is powered on;
Single optical interface:
configure the 1 ~ 8 tributary E1 services to the 1 ~ 8 STM-1
timeslots, bidirectional;
Dual optical interfaces:
configure the 1 ~ 8 tributary E1 services to the 1 ~ 8 STM-1
timeslots, unidirectional PP protected.
Service auto-configuration
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
22/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21
Main Features of OptiX Metro 200
On the wall;
In the 19-inch cabinet;
In the 300mm-deep ETS cabinet;
In the 600mm-deep ETS cabinet.
Installation
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
23/24
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22
Summary
Network Application
Hardware Structure
Units Introduction
Main Features of OptiX Metro 200
-
7/31/2019 OTA101103 OptiX Metro 200 Hardware Description ISSUE1.10
24/24
www.huawei.com
Thank You