Orion Telecom Networks Inc. 2005
Remote Alarm Reporting andRemote Alarm Reporting andSite Monitoring EquipmentSite Monitoring Equipment
Slide 1
Updated : January 1st, 2005
16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.
Phone: +1 (480) 816-8672Fax: +1 (480) 816-0115
E-mail: [email protected] Site: http://www.oriontelecom.com
Orion Telecom Networks Inc. 2005
Remote Alarm Remote Alarm SuiteSuite
Remote Alarm Reporting, Site Monitoring and Management Remote Alarm Reporting, Site Monitoring and Management
Equipment SuiteEquipment Suite offer three types of solutionsoffer three types of solutions
Product OverviewProduct Overview
Remote Alarm Reporting - Solution # 1Remote Alarm Reporting - Solution # 1
Remote Site Monitoring - Solution # 2Remote Site Monitoring - Solution # 2
Line Testing - Solution # 3Line Testing - Solution # 3
Slide 2
Orion Telecom Networks Inc. 2005
Used to configure, monitor, control and manage
remote sites from a central monitoring location over
• Dedicated serial data (RS232) links,
• Over the Internet (TCP/IP protocol).
Remote Alarm Reporting, Site Monitoring and Remote Alarm Reporting, Site Monitoring and
Management Equipment SuiteManagement Equipment Suite - An Overview- An Overview
Remote Alarm Remote Alarm SuiteSuite
Slide 3
Orion Telecom Networks Inc. 2005
Remote Site Alarm Input TerminalRemote Site Alarm Input Terminal
• Access, manage and control Remote Site Alarms
• Alarms Reporting.
• Manage through PC using a Window based GUI
• Can be accessed, managed and controlled from a Central Site over :
a) Serial RS232 Data Link
b) The Internet (using TCP/IP Protocol)
Central Site Alarm Recording EquipmentCentral Site Alarm Recording Equipment
• Store and (continuously) log ALL Alarms that, may appear at the Remote
Sites during any given 7 days & 24 hour time period.
• Can configure the Remote Site equipment using a Windows based GUI
Remote Alarm Remote Alarm SuiteSuite
Slide 4
Orion Telecom Networks Inc. 2005
Uses and ApplicationsUses and Applications
• SCADA applications power distribution lines, oil pipe lines,
gas pipelines and water pipe lines.
• Monitoring and Managing Remote (unmanned) Cellular Sites.
• Managing and Monitoring Remote Radio Relay (unmanned) Sites.
• Managing and Monitoring Remote DLC or RSU (unmanned)
telecom sites.
• Security and Surveillance.
Remote Alarm Remote Alarm SuiteSuite
Slide 5
Orion Telecom Networks Inc. 2005
Remote Alarm Reporting, Site Monitoring and Management Remote Alarm Reporting, Site Monitoring and Management Equipment Suite offers the following alarms and functionsEquipment Suite offers the following alarms and functions
• Remote Site Alarms
• Equipment Alarm(s) Relay Open / Relay Close (User Configurable) Up to 32 Alarm Inputs per Site / Location.
• Intruder Alarm
• Fire Alarm
• Smoke Alarm
• Flooding Alarm.
• AC Mains Power Failure Alarm, etc.
Remote Alarm Remote Alarm SuiteSuite
Slide 6
Orion Telecom Networks Inc. 2005
• Remote Site Monitoring Facility
To Monitor following parameters
• Remote Site Temperature
• AC Mains Voltage at the Remote Site
• DC Battery Voltage of the battery-bank of the power backup
equipment (12VDC and 48VDC).
• Remote Site Control Facility
Management of the power back-up battery banks
• Read voltage remotely
• Set threshold limit to shut-down / switch over to another
source - AC main or Solar
Remote Alarm Remote Alarm SuiteSuite
Slide 7
Orion Telecom Networks Inc. 2005
• Temperature Monitoring and Management facility
• “Monitor and Read” temperature of each remote sites
• Site environmental management
Remote Alarm Remote Alarm SuiteSuite
• automatically "switch-on" or "switch-off" vent fans /
heaters / air conditioners at the high / low temperature
thresholds set by the User.
• Providing a power "Re-Set” to any equipment - remotely
• Initiate and provide a Power-Set (turn-off / turn-on) to any
equipment installed at the Remote Site from a Central
Monitoring location.
Slide 8
Orion Telecom Networks Inc. 2005
• Remote line / cable pair testing - Telecom application
• Perform the line testing of the remote cable pairs
• Test the line for Open, Short, Leakage and the presence of "foreign" AC potential on the cable pairs.
• Ideal for Telco deployment at hard-to-reach unmanned Remote Sites
• Helps to isolate the faulty cable pair before making a service call
Remote Alarm Remote Alarm SuiteSuite
Slide 9
Orion Telecom Networks Inc. 2005
Remote Site Terminal: Remote Site Terminal:
• Connect up to 32 Relay Inputs
• Powered by -48 VDC input (AC main optional)
• “Relay Open” or “Relay Close” condition to generate an “Alarm” - User Configurable
• Used to monitor, control and manage remote sites from a central monitoring location over
a) Dedicated Serial data (RS232) links
b) Over the Internet (TCP/IP protocol).
Solution # 1:Solution # 1:
Slide 10
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Central Site EquipmentCentral Site Equipment
• Report and recognize upto 32 Alarm Inputs at each Remote Site
• Store and (continuously) log ALL Alarms that, may appear
at the Remote Sites during any given 7 days & 24 hour
time period.
• Configure using a Window based GUI
• Display the status of all the Active Alarm on LCD display
• Can be connected upto 8 Remote Sites
Slide 11
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Dedicated serial data (RS-232) links
(Example: using dedicated serial data (RS-232) links )
1 to 32 Relays
1 to 32 Relays
1 to 32 Relays
1 to 32 Relays 1 to 32 Relays
1 to 32 Relays
1 to 32 Relays
1 to 32 Relays
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
Dedicated Serial (Asynchronous, RS 232)
Links
VCL-MonitoringSystem
Site 1
Site 2
Site 3
Site 4
Site 5
Site 6
Site 7
Site 8
Slide 12
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Central Office
VCL-MonitoringSystem
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
HUB HUB
HUB HUB
Remote Network(s)3 through 6
Ne
two
rke
d(T
CP
/IP
Pro
toco
l)N
etw
orke
d(T
CP
/IP P
roto
col)
INTERNETINTERNET
TCP/IP Protocol Networked (Internet) Links
10 BaseT Ethernet
Remote Network / Site 1
Remote Network / Site 2 Remote Network / Site 7
Remote Network / Site 8
(Example : using TCP/IP protocol networked (Internet) Links)
Networked(TCP/IP Protocol)
32 Relay Inputs 32 Relay Inputs
32 Relay Inputs 32 Relay Inputs
Slide 13
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
VCL-Remote Device
Mixed network of dedicated serial (RS-232)Data links and network (TCP/IP) protocol links
Central Office
VCL-MonitoringSystem
Dedicated Serial
(Asynchronous, RS 232) Links
Remote Site 8
32 Relay Inputs
32 Relay Inputs32 Relay Inputs
32 Relay Inputs
Remote Site(s) 6 through 7Remote Network / Site 2
Remote Network / Site 1
VCL-Remote Device
VCL-Remote DeviceVCL-Remote
Device
HUB
HUB
INTERNETINTERNET
Remote Network(s)3 through 4
10 BaseT Ethernet
(Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links)
Remote Site 5
Slide 14
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
RJ-45 for connection withdedicated serial data (RS-232)links or networked TCP-IP links
DB-9 for connectionwith PC
Central site - Alarm Monitoring Equipment (Back View)
- 48 V5V
“Scroll” LCD Display
ACKRemoteSite #
AlarmSite #
System # (Remote #)Alarm #
Text of Alarm(Configured by the user)
Central site - Alarm Monitoring Equipment (Front View)
Alarm AcknowledgeSwitch
Slide 15
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Central Site Alarm Recording Equipment : Specifications Central Site Alarm Recording Equipment : Specifications
Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for
Serial (Point to Point) Connection : to connect upto 8 remote sites to the
central monitoring site on point to point serial data links.
Number of Remote Site (Remote Terminals)That can be Connected to central siteMonitoring Equipment 8 (Remote Terminals)
Type RS 232Tx, Rx, Gnd
Mode Asynchronous
Baud Rate 9.6 kbps - Fixed
Data Size 8bits
Parity None
Flow Control None ( Xon / Xoff )
Stop Bit 1
Slide 16
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Ethernet Specifications @ 10 BaseT Data Interface Port for Networked
(IP/Internet) Connection : to connect upto 8 remote sites to the central
monitoring site over networked (IP/Internet) links.
Number of Remote Site (Remote Terminals)That can be Connected to central siteMonitoring Equipment 8 (Remote Terminals)
Conformity IEEE 802.3.
Type 4 Wire,Twisted Pair Cabling. (Categories 3, 4 or 5).
Distance limit 100 metres (Approx. 328 feet)per Segment.
Bit Rate 10 Mbps.
Power:-48VDC (AC Input Optional)
Dimensions:2U High19-inch Shelf (19-inch rack mounting).
Slide 17
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links.
Number of Relay Inputs (User Configurable - Relay Open Relay Close Alarm Inputs)Per Remote Site Terminal 32
Connection between Remote Site Terminaland Central Site Terminal
Serial Data Interfaces 1
Type RS 232Tx, Rx, Gnd
Mode Asynchronous
Baud Rate 9.6 kbps - Fixed
Data Size 8bits
Parity None
Flow Control None ( Xon / Xoff )
Stop Bit 1.
Slide 18
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP / Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links.
Connection between remote site terminaland central site terminal
Ethernet Interfaces 1
Conformity IEEE 802.3.
Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5).
Distance limit 100 metres (Approx 328 feet) per Segment.
Bit Rate 10Mbps
Power:-48VDC (AC Input Optional)
Dimensions:1U High19-inch Shelf (19-inch rack mounting).
Slide 19
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Remote site - Alarm Input Terminal
32 Relay Inputs ("Relay Open", or
"Relay Close" condition to generate an "Alarm" -User Configurable).
DB-9 for connection withdedicated serial data (RS-232)
links
RJ-45 for connectionwith ethernet
Slide 20
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Solution # 2Solution # 2
• Remote Site Management & Monitoring can be connected to Central Site through
a) Dedicated Serial (RS232) data link
b) Internet TCP/IP Protocol
• Any number of Remote Site Monitoring equipment may be
installed and managed from Central Site.
• All Remote Site Monitoring, Management and Control function are accomplished through a PC using a Window based GUI.
Remote Site Monitoring EquipmentRemote Site Monitoring Equipment
Slide 21
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Provide the following Alarms:
• Intruder Alarm
• Fire Alarm
• Smoke Alarm
• Flooding Alarm.
• Equipment Alarm(s) Relay Open / Relay Close (User Configurable) Upto 5 Alarm Inputs per Site / Location.
Control and Manage the following functionsControl and Manage the following functions
• AC Mains Power Failure Alarm.
• And to select the “switch” to the selected back-up power source.
• “Read" and "Control" Remote Site Temperature
• Temperature monitoring and management facility
Slide 22
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
• "Read" AC Mains Voltage at the Remote Site.
• “Read" DC Battery Voltage of the battery-bank of the power back-up equipment (12VDC and 48VDC) and "Manage" "battery-banks.
• Remotely read the voltage of power and back-up battery
• Set the threshold limit to shut down or to switch over to
another battery line “remotely”
• Useful in case where there is two power back-up units for
added protection
• To initiate a Power "Re-Set" of the connected Equipment.
• To provide a power reset to any equipment - remotely
Slide 23
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Dedicated Serial (Asynchronous, RS 232)
Links
Central Office
VCL-Remote Device
1 to 32 Relays
(Example: using dedicated serial data (RS-232) links )
Dedicated serial data (RS-232) links
Site 8
Slide 24
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
VCL-Remote Device
32 Relay Inputs32 Relay Inputs
32 Relay Inputs 32 Relay Inputs
VCL-Remote Device
VCL-Remote Device
VCL-Remote Device
HUB
HUB
HUB
HUB
Ne
two
rke
d(T
CP
/IP
Pro
toco
l)N
etw
orke
d(T
CP
/IP P
roto
col)
INTERNETINTERNET
Remote Network(s)3 through 6
10 BaseT Ethernet
TCP/IP protocol networked (Internet) LinksCentral Office
Remote Network / Site 8
Remote Network / Site 7
Remote Network / Site 1
Remote Network / Site 2
(Example : using TCP/IP protocol networked (Internet) Links)
Slide 25
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
VCL-Remote Device
HUB
10 BaseT Ethernet
VCL-Remote Device
VCL-Remote Device
HUB
INTERNETINTERNET
Remote Network(s)2 through 7
COM 2COM 1Dedicated Serial
(Asynchronous, RS 232)Links
Central Office
32 Relay Inputs
32 Relay Inputs
32 Relay Inputs
Remote Site 8Remote Network / Site 1
Remote Network / Site 8
Mixed network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links
(Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links)
Slide 26
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links.
Number of relay inputs (user configurable - relay open relay close alarm inputs)Per Remote Site Terminal 32
Connection between Remote Site Terminaland Central Site Terminal
Serial Data Interfaces 1
Type RS 232Tx, Rx, Gnd
Mode Asynchronous
Baud Rate 9.6 kbps - Fixed
Data Size 8bits
Parity None
Flow Control None ( Xon / Xoff )
Stop Bit 1
Slide 27
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP/Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links.
Connection between remote site terminaland central site terminal
Ethernet Interfaces 1.
Conformity IEEE 802.3.
Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5).
Distance limit 100 metres (Approx 328 feet) per Segment.
Bit Rate 10 Mbps.
Slide 28
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Solution # 3Solution # 3
• Remote line / cable pair testing - Telecom application
• Perform the line testing of the remote cable pairs
• Test the line for Open, Short, Leakage and the presence of "foreign" AC potential on the cable pairs.
• Ideal for Telco deployment at hard-to-reach unmanned Remote Sites
• Helps to isolate the faulty cable pair before making a service call
Slide 29
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Orion’s Orion’s ProductsProducts
E1, Voice & Data Drop-Insert Multiplexer
PRI ISDN (Q.931) Multiplexers
E1 Intelligent Channel Banks
E1 / T1 DCME (Digital Circuit Multiplication Equipment) - Voice Compression Equipment
Thin Route DCME
E1 / T1 Echo Cancellers
E1 / T1 Digital Cross Connect
T1 / E1 Converters
E3, 34Mbps Multiplexer
34Mbps Optical Line Transmission Equipment (OLTE)
STM 1 / STM 4 - SDH Equipment
Remote Asset Management Systems
Slide 30
Remote Alarm Remote Alarm SuiteSuite
Orion Telecom Networks Inc. 2005
Thank you for your attentionThank you for your attention
For more details visit us at our Web Site at
http://www.oriontelecom.com
16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.
Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115E-mail: [email protected]
Slide 31
Remote Alarm Remote Alarm SuiteSuite