Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and...

37
Oral radiology II

Transcript of Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and...

Page 1: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Oral radiology II

Page 2: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

X-Ray Machine

The X-ray machine consist of: 1) head A) tubeB) cone and accessories2) Control panel and timer3) Adjusting arm

Page 3: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

INTRAORAL X-RAY FILM

Periapical View

Bitewing View

Occlusal View

Page 4: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.
Page 5: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Periapical View

Periapical View Film packs corne in three sizes:

0 for small children (22 X 35mm)

1, which is relatively narrow and used for views of the anterior teeth (24 X40mm)

2, the standard film size used for adults (31 X 41 mm)

Page 6: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Processing X-Ray Film

Manual processing

Rapid processing chemicals

Automatic Film Processing

Page 7: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

MANUAL PROCESSING

Page 8: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Developer – water - fixer

Page 9: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Automatic Film Processing

Page 10: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

GENERAL STEPS FOR MAKINGAN EXPOSURE

Greet and seat the patient. Adjust the x-ray unit setting. position the tube head. Wash hands thoroughly. Examine the oral cavity. Position the film. position the x-ray tube. Make the exposure.

Page 11: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Factors Affecting Quality of Image

Factors affecting the image are related to:

1. Machine

2. Object

3. Film

4. Processing of film

Page 12: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Periapical X-rays

show the whole tooth -- from the crown to beyond the end of the root to where the tooth is anchored in the jaw. Each periapical X-ray shows this full tooth dimension and includes all the teeth in one portion of either the upper or lower jaw. Periapical X-rays are used to detect any abnormalities of the root structure and surrounding bone structure

Page 13: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Two intraoral projection techniques are commonly used for periapical radiography:

the paralleling technique and

the bisecting-angle technique

Page 14: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.
Page 15: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.
Page 16: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.
Page 17: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

The vertical angulations

Page 18: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Horizontal angulations

Incisors /0/ Mandibular canine /45/

Maxillary canine /60-75/

Premolars/70-80/

Molars/80-90/

Page 19: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Maxillary Incisors

A - Nasal septum

B - Inferior concha

C - Nasal fossa

D - Nasal spine

E - Incisive foramen

F – Nose

G - Median palatine suture

Page 20: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Incisive foramen

Page 21: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Nasal septum

Page 22: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Maxillary Canine

A = Floor of nasal fossa

B = Maxillary sinus

C = Lateral fossa

D = Nose

Page 23: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

a = floor of nasal fossa b = maxillary sinus

c = lateral fossa a & b form inverted Y

Page 24: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Maxillary Premolar

A = Sinus recess

B = Sinus septum

C = Zygomatic Process

D = Maxillary sinus

Page 25: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

a = Zygomatic Processb = sinus recessc = sinus septumd = maxillary sinus

Page 26: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Maxillary Molar

��A- Zygoma

B - Maxillary sinus

C - Sinus recess

D - Maxillary tuberosity

E - Coronoid process

F - Hamular Process

G - Pterygoid plate

Page 27: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

a = maxillary tuberosity* b = coronoid process

c = hamular process d = pterygoid platese = zygoma (dotted lines)f = maxillary sinus g = sinus recess

Page 28: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Mandibular Incisors

A = Mental fossa

B = Lingual foramen

C = Genial tubercles

D = Mental ridge

Page 29: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Lingual foramen. Radiolucent “hole” in center of genial tubercles. Lingual nutrient vessels pass through this foramen

Page 30: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Mandibular Canine

A = Mental ridge

B = Lingual foramen

C = Genial tubercles

D = Cortical bone

E = Mental foramen

Page 31: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Mandibular Premolar

A = Mylohyoid ridge

B = Submandibular gland fossa

C = Mandibular canal

D = Mental foramen

Page 32: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

The mental foramen (blue arrow) is adjacent to a periapical lesion associated with tooth # 21 (red arrow). There is slight external resorption on # 21

Page 33: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Mandibular Molar

A = External oblique ridge

B = Mylohyoid ridge (internal oblique)

C = Submandibular gland fossa

D = Mandibular canal

Page 34: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

a = external oblique ridge b = mylohyoid ridge

c = mandibular canal d = submandibular gland fossa

Page 35: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.

Radiation Safety & Protection

Page 36: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.
Page 37: Oral radiology II. X-Ray Machine The X-ray machine consist of: 1) head A) tube B) cone and accessories 2) Control panel and timer 3) Adjusting arm.