Optimizing yOur wOrkflOw

8
WORKLIST DICOM WORKLIST SERVER OPTIMIZING YOUR WORKFLOW VERSION 2.0

Transcript of Optimizing yOur wOrkflOw

Page 1: Optimizing yOur wOrkflOw

WORKLISTdIcOm WORKLIST SeRveR

OptimizingyOur

wOrkflOw

veRS

ION

2.0

Page 2: Optimizing yOur wOrkflOw

2

DICOM worklists are indispensable in a radiological environment, as they accelerate the modality workflow and ensure that typing errors are avoided. Through their use, consis-tent data is maintained throughout all medical imaging systems.

iQ-WORKLIST can interface with virtu-ally any radiology, practice or hospi-tal information system, read schedul-ing data, and create DICOM worklists for imaging modalities.

COnSiStEnt DAtA thrOughOut riS AnD pACS

In addition, it can read HL7 order re-quests (ORM/OMG), patient update/merge messages (ADT), and also ac-cepts BDT/GDT or structured text files as a data source.

iQ-WORKLIST can be easily installed and configured due to the included configuration presets. It is reliable and easy to maintain. For special circum-stances, iQ-WORKLIST offers PACS administrators a powerful mapping tool for data conversion between various standards.

iQ-wOrkliSt

iQ-WORKLIST is a powerful DICOM worklist server and a must-have in every imaging center.

Three versions are available to meet all of your connection needs:

iQ-WORKLISTfor a maximum of 2 modalities

iQ-WORKLIST PROfor a maximum of 10 modalities

iQ-WORKLIST PRemIUmfor an unlimited number of modalitiesAlso includes an ADT module for pa-tient reconciliation support.

Page 3: Optimizing yOur wOrkflOw

3

iQ-wOrkliSt

FULLY AUTOmATed WORKFLOW

iQ-WORKLIST can read procedure information from connected modali-ties, such as radiation dose, billing data, study status, series, or image data, and provide it to the feeding information system like HIS, RIS or EMR. This is possible through MPPS (Modali-ty Performed Procedure Steps) which enables iQ-WORKLIST to accept mes-sages for creating, modifying, and returning MPPS information.

SUPeRIOR PeRFORmANce

iQ-WORKLIST 2.0 uses an SQL data-base which increases its perfor-mance and results in more efficient data processing. It can be em-ployed flexibly in both small imaging centers and big hospitals. Because it processes incoming messages and simultaneous worklist queries using multi-threads, iQ-WORKLIST can also be used centrally for large multi-site projects.

cOmPATIBILITY

Many information systems lack an HL7 interface. By using iQ-WORKLIST, virtually any information system can be connected using freely configu-rable text files. In addition, iQ-WORKLIST provides Unicode support (UTF-8) and thus speaks all major world languages. Lo-cal character sets can be automati-cally converted to Unicode.

▪ Patient’s Name, Patient ID, Patients Birth Date, Patient’s Sex, Patient’s Weight, Patient State (NEW!)

▪ Pregnancy Status (NEW!) ▪ Medical Alerts (NEW!) ▪ Additional Patient History ▪ Allergies ▪ Special Needs (NEW!)

▪ Admission ID (NEW!) ▪ Current Patient Location (NEW!)

▪ Accession Number ▪ Requesting Physician ▪ Referring Physician’s Name (NEW!) ▪ Requesting Service (NEW!) ▪ Requested Procedure ID, Requested Procedure Description ▪ Study Instance UID ▪ Requested Procedure Priority ▪ Patient Transport Arrangements (NEW!) ▪ Scheduled Station AE Title ▪ Scheduled Procedure Step Start Date and Start Time ▪ Modality ▪ Scheduled Performing Physician’s Name ▪ Scheduled Procedure Step Description ▪ Scheduled Station Name ▪ Scheduled Procedure Step Location ▪ Scheduled Protocol Codes (NEW!) ▪ Scheduled Procedure Step ID (NEW!)

PATIeNT

vISIT

STUdY

iQ-WORKLIST supports the following C-FIND Query and Retrieve tags. (A complete list can be found in the iQ-WORKLIST 2.0 DICOM Conformance Statement):

Page 4: Optimizing yOur wOrkflOw

4

1 2

3

4

5

2A

2c

6A

6B

2B

6c

Patient RIS, HIS, EMR iQ-WORKLIST Server

Imaging modality

1 The patient is registered to a RIS, HIS, PMS, or any other medical in-formation system (MIS).

2 The MIS sends scheduling data to the iQ-WORKLIST server.

a) as an HL7 order b) as a GDT order

c)asatextfile

iQ-wOrkliSt BASiC/prO wOrkflOw

3 iQ-WORKLIST collects the sched-uling information in a local da-tabase and provides a DICOM worklist to any imaging modality.

4 The imaging modalities query the worklist manually or automati-cally to get accurate patient and scheduling information.

5 The imaging modalities query the worklist manually or automatically and send status information back to iQ-WORKLIST.

6 iQ-WORKLIST forwards the status information to the medical infor-mation system:

a) answering the HL7 order request b) answering the GDT order request c)inresponsetothetextfile

HL7 order

Status

GDT order

Status

Status

Text file order Status

Imaging modality

Page 5: Optimizing yOur wOrkflOw

5

7 9

8

iQ-wOrkliSt prEmium wOrkflOw in ADDitiOn tO iQ-wOrkliSt BASiC/prO wOrkflOw

7 The MIS sends an ADT message to iQ-WORKLIST, e.g. in case the pa-tient information is unknown dur-ing initial imaging.

RIS, HIS, EMRiQ-WORKLIST

ServerImaging modality

iQ-WEBX

ADT

8 iQ-WEBX queries iQ-WORKLIST in order to reconcile patient demo-graphics after the identity of the patient is known or has changed.

thE SOlutiOn CAn BE SO SimplE

9 The imaging modalities query the worklist manually or auto-matically to get accurate pa-tient and scheduling information.

Page 6: Optimizing yOur wOrkflOw

6

▪ Runs as an NT service in the background ▪ Includes several logging levels and files for documentation and easy error

tracking (NEW!) ▪ Fully automated workflow through MPPS (Modality Performed Procedure

Steps) (NEW!) ▪ SQL database for enhanced performance and scalability (NEW!) ▪ Higher compatibility through Unicode support for virtually all languages, a cus-

tomizable text parser, and an extended list of supported worklist search key-words (NEW!)

▪ Application and event acknowledgment support (NEW!) ▪ Message syntax dictionary (NEW!)

▪ Reads HL7 order messages (ORM, OMG); (Refer to HL7 Conformance State-ment for detailed information) (NEW!)

▪ Reads BDT/GDT data ▪ Reads study data from structured text files ▪ Processes multiple sources (HL7/BDT/Text) concurrently ▪ Compatible to HL7 2.x ▪ Maps files using regular expressions to adapt BDT/GDT/Text file dialects ▪ Maps HL7 files using message fields ▪ HL7 network and file message listener ▪ Customizable actions based on incoming messages (NEW!) ▪ Support of multiple orders in a single order message (NEW!)

▪ Serves up to two devices (DICOM WORKLIST SCU nodes) ▪ DICOM worklists based on scheduling data ▪ Creates unique Study Instance UIDs for the querying modalities ▪ Accession numbers can be created based on time stamps or incremented IDs ▪ Compatible with any DICOM worklist client ▪ Supports any modality queries, e.g. by patient name, patient ID, birth date, mo-

dality, scheduled station AE title, scheduled procedure start time and date

iQ-wOrkliSt fEAturES

GeNeRAL

INPUT

dIcOm

Page 7: Optimizing yOur wOrkflOw

7

iQ-wOrkliSt prO fEAturES in ADDitiOn tO iQ-wOrkliSt fEAturES

dIcOm ▪ Serves up to 10 devices (DICOM WORKLIST SCU nodes)

iQ-wOrkliSt prEmium fEAturES in ADDitiOn tO iQ-wOrkliSt prO

dIcOm

INPUT

▪ Serves an unlimited number of devices (DICOM WORKLIST SCU nodes)

▪ Reads HL7 ADT messages for DICOM modality worklist-based patient data reconciliation

Page 8: Optimizing yOur wOrkflOw

IMAGE INFORMATION SYSTEMS LTD.3RD FLOOR | 207 REGENT STREET | LONDON W1B 3HH | UNITED KINGDOM

TEL. UK: +44 20 3289 1500 | TEL. GER: +49 381 496 5820 | TEL. US: +1 704 323 6663 FAX GER: +49 381 496 582 99

WWW.IMAGE-SYSTEMS.BIZ | [email protected]

Pict

ure

pro

of: P

ictu

res

by

ww

w.F

oto

lia.d

e ▪

ww

w.is

tock

pho

to.c

om

▪ w

ww

.shu

tte

rsto

ck.c

om

© 2

016

IMA

GE

Info

rmat

ion

Syst

ems L

td. –

Med

ical

Imag

ing

with

iQ! –

iQ-W

ORK

LIST

2.0

PUB

INT

EN 0

04R

SYSTEM REQUIREMENTS

iQ-SYSTEM PACS The full featured, reliable and affordable PACSiQ-RIS The smooth radiology information system MED-TAB™ Superior portable image analysis

OUR PRODUCTS FOR YOUR IMAGING NEEDS

HARDWARE & SOFTWARE REQUIREMENTSMINIMUM RECOMMENDED

OS: Windows XP Professional with SP3 (only as an upgrade for currently running iQ-WORKLIST 1.x versions)Windows 7 with SP 1, Windows 8, 8.1, 10, Professional or higher (32/64 bit)Windows Server 2008 R2, 2012, 2012 R2, Standard (64 bit)

Windows Server 2008 R2 Enterprise with SP 1 (64 bit) Windows Server 2012 R2 Standard (64 bit)

CPU: Single Core, 2 GHz Dual or Multi Core, 1.8 GHz or higher

RAM: 1024 MB RAM 2048 MB RAM or higher

HDD: 20 GB free hard disc space 120 GB free hard disc space

Network: 100 Mbit/s 1 Gbit/s