Opportunity to Participate
description
Transcript of Opportunity to Participate
![Page 1: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/1.jpg)
Opportunity to Participate
• EEG study of auditory attention – takes about 2 hours
• Sign up on sheet or email [email protected]
• Two extra points added to your final grade!
![Page 2: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/2.jpg)
Functional Imaging• blood flow overshoots
baseline after a brain region is activated
• More oxygenated blood in that region increases MR signal from that region (other regions de-phase faster)
![Page 3: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/3.jpg)
Functional Imaging
• It is important to recognize that fMRI “sees” changes in the ratio of oxygenated to deoxygenated blood - nothing more– BOLD: Blood Oxygenation Level Dependant
contrast
• How do we create those pretty pictures?
![Page 4: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/4.jpg)
Functional Imaging• It is important to recognize that fMRI “sees”
changes in the ratio of oxygenated to deoxygenated blood - nothing more– BOLD: Blood Oxygenation Level Dependant contrast
• How do we create those pretty pictures?
• We ask the question “When the subject engages in this cognitive task, where does blood oxygenation change significantly?” “where does it change randomly?”
![Page 5: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/5.jpg)
Experimental Design in fMRI
• Experimental Design is crucial in using fMRI
• Simplest design is called “Blocked”– alternates between active and “rest” conditions
Active Rest Active Rest
60 sec 60 sec 60 sec 60 sec
![Page 6: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/6.jpg)
Experimental Design in fMRI
• Experimental Design is crucial in using fMRI
• Simplest design is called “Blocked”– alternates between active and “rest” conditions
Active Rest Active Rest
60 sec 60 sec 60 sec 60 sec
![Page 7: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/7.jpg)
Experimental Design in fMRI
• A voxel in tissue insensitive to the task demands shows random signal change
Active Rest Active Rest
60 sec 60 sec 60 sec 60 sec
Sig
nal
![Page 8: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/8.jpg)
Experimental Design in fMRI
• A voxel in tissue that responds to the task shows signal change that matches the timecourse of the stimulus
Active Rest Active Rest
60 sec 60 sec 60 sec 60 sec
Sig
nal
![Page 9: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/9.jpg)
Experimental Design in fMRI
• A real example of fMRI design done well:– alternate moving, blank and stationary
visual input
Moving Blank Stationary Blank
40 sec 40 sec 40 sec 40 sec
![Page 10: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/10.jpg)
Experimental Design in fMRI
• Voxels in Primary cortex tracked all stimuli
![Page 11: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/11.jpg)
Experimental Design in fMRI
• Voxels in area MT tracked only the onset of motion
![Page 12: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/12.jpg)
Experimental Design in fMRI
• Voxels in area MT tracked only the onset of motion
• How did they know to look in area MT?
![Page 13: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/13.jpg)
PET: another way to measure blood Oxygenation
• Positron Emission Tomography (PET)• Injects a radioisotope of oxygen• PET scanner detects the concentration of this isotope as it
decays
![Page 14: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/14.jpg)
PET: another way to measure blood Oxygenation
• Although oxygenation is measured differently, the logic of PET and fMRI are similar: compare active and “rest” conditions
![Page 15: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/15.jpg)
Advantages of fMRI
• All techniques have certain advantages
• A good scientist leverages these advantages
![Page 16: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/16.jpg)
Advantages of fMRI
• Advantages of MRI:1. Most hospitals have MRI scanners that
can be used for fMRI (PET is rare)2. Better spatial resolution in fMRI than PET3. Structural MRI is usually needed anyway4. No radioactivity in MRI5. Better temporal resolution in MRI
![Page 17: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/17.jpg)
Advantages of PET
• Advantages of PET:1. Quiet2. A number of different molecules can be
labeled and imaged in the body
![Page 18: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/18.jpg)
Limitations of fMRI
• All techniques have constraints and limitations
• A good scientist is careful to interpret data within those constraints
![Page 19: Opportunity to Participate](https://reader035.fdocuments.us/reader035/viewer/2022062218/56815ed3550346895dcd666e/html5/thumbnails/19.jpg)
Limitations of fMRI
• Limitations of MRI and PET:1. BOLD signal change does not necessarily
mean a region was specifically engaged in a cognitive operation
2. Poor temporal resolution - depends on slow changes in blood flow
3. expensive